Thermometer Hygrometer Clock Manual
Monitor Front: Monitor Back:
1
2
3
4
5
6
7
8 A B C D E9 10
1. Alarm clock icons
2. Time display
3. Snooze icon
4. Calendar
5. Weekday
6. Indoor humidity
7. Indoor temperature
8. Integrated hang hole
9. Battery compartment 3xAA (batteries not included)
10. Holder
A. MODE button
B. UP button
C. DOWN button
D. C/F button
E. SNOOZE button
Main Feature
a. LCD screen size: 194mm x 110mm
b. Time form 12HR/24HR
c. Time, date and week display (week display in 7 languages )
d. Alarm function
e. Snooze function (1 ~ 60 minutes can been setting)
f. Temperature detection range: -9.9 ~ +50°C (14.1 ~ 122.0°F) resolution is 0.1°C/°F detection
period is 20s
g. Humidity detection range: 20%RH ~ 95%RH
h. Buttons: MODE, UP, DOWN, C/F, SNOOZE
LCD Display
Key Function List
function
operation
Normal
mode
Setting
mode
MODE UP DOWN C/F SNOOZE
press
press
hold
hold
switch time
interface and
alarm interface
into setting
mode
confirm setting
mode / into
next setting
open /
close alarm
increase
on step
increase by
8 steps/s
---
--- ---
---
---
---
---
switch
°C/°F
switch
°C/°F
decrease
one step
decrease by
8 steps/s
into snooze
function
into snooze
function
Power Up and Reset
a. When the clock insert the battery, LCD display for 3 seconds, while issuing three BI, then
converted to the standard display mode, while showing the environment where the temperature
and humidity.
b. Power up default display:
Default time: 0:00, 24HR
Default date: M01/D01 (year:2015, date form: M/D)
Default week: THU (language: ENG )
Default temperature unit: °C
Operation
1. Normal Mode
a. Press “MODE (A)” to switch time mode and alarm mode.
b. Press and hold “MODE (A)” to the time setting mode and alarm setting mode.
c. In the normal mode, press “UP (B)” to open or close the AL.
d. In the normal mode, press “C/F (D)” or “DOWN (C)” to switch °C/°F.
e. Press “UP (B)” and “DOWN (C)” to setting the desired value, press and hold “UP (B)” or
“DOWN (C)” for 2s to setting the value by 8teps/s speed, press “MODE (A)” to confirm the
setting value.
f. Press "SNOOZE (E)" to enter snooze mode when the alarm sounds.
2 Time Setting Mode
a. In the normal time mode, press “MODE (A)” for 2s into time setting,and the setting item will be
flashing.
b. In the time setting mode, press the “MODE (A)” key to confirm the setting result and switch to the
next setting item, the setting item is as follows: Time form→hour→minute→date form→year→
mouth→date→week language→exit.
c. Press the “MODE (A)” button for 2s to changing the time showing from 12 hours to 24 hours.
d. In the setting mode, press “UP (B)” and “DOWN (C)” to setting the desired value, press and hold
“UP (B)” or “DOWN (C)” for 2s to setting the value by 8teps/s speed. Press “MODE (A)” to confirm
the setting value.
e. When the value is changed by pressing the “UP (B)” or “DOWN (C)” key while setting the minute
item, the number of seconds is automatically cleared to 00 when the value of the minute is changed.
f. When the date item is set, the display of the week changes depending on the setting value of
the date.
g. The maximum time that time can be set is: January 1, 2000 ~ December 31, 2099.
h. Week language a total of seven countries, the order of setting: ENG →GER →FRE →SPA →ITA
→ DUT →DAN, the week show as shown in the table below:
i. No keys operation within 20 seconds will discard the item being set and exit the setup state.
3 Alarm Setting
a. In normal mode, short press “MODE (A)” key to switch between time display interface and alarm time
display interface. In the alarm time interface, no key operation for 20 seconds, automatically return
to the time display interface.
b. In the alarm time display interface, press and hold the “MODE (A)” button for more than 2 seconds to
enter the alarm time setting mode.
c. In the alarm time setting mode, press the “MODE (A)” key to confirm the setting item and switch to the
next setting item, the setting items are as follows: hour→minute→snooze duration→exit.
d. In the setting mode, press the “UP (B)” or “DOWN (C)” button to adjust the value and item of the
setting, press 1 time, to increase or decrease the value, press and hold for more than 2 seconds,
set the value forward continuous value or continuous impairment, to adjust the value every 1/8 second.
e. No keys operation within 20 seconds will discard the item being set and exit the setup state.
f. Snooze time can be set to 1 ~ 60 and OFF, the default setting is in minutes, when set to OFF, no
snooze function. (Default is set to 5 minutes), in this setting interface, the symbol "ZZ" and the value
of the minute bar are displayed.
g. power up the default alarm is off, the alarm time defaults to 6:00 am, set the alarm time
automatically open alarm.
h. Press the “UP (B)” key in the standard mode to turn the alarm on and off.
4. Alarm and Snooze Instructions
a. Press the “UP (B)” key to turn on or off the alarm function. When turned on, the alarm symbol " " is
displayed, indicating that the alarm function is in the open mode.
b. When the alarm is in the on state (alarm symbol " " display), the time travel time to set the alarm
time, the host beep alarm alarm, the time is 2 minutes, while the alarm symbol " " flashing display.
c. When the alarm process, other than "SNOOZE (E)" button press any key or do not do any operation
after the alarm 2 minutes to the end, do not enter the snooze mode, and so go to the next alarm
time and then into the alarm.
d. On the alarm process, press the "SNOOZE (E)" button once to suspend the alarm, enter the snooze
mode, snooze time according to set the time, the alarm symbol “ "and snooze symbol" " flashing
show, once again into the alarm when snooze is time to timing, If you press the "SNOOZE (E)" key
again and then enter the snooze mode again, you can cycle snooze.
e. If the snooze set to OFF, press any button to terminate the alarm, it can only into alarm again
until the time travel the alarm time on the next time.
f. Snooze mode, press any button other than "SNOOZE (E)" to exit snooze mode, the alarm
symbol " " does not flash, snooze symbol " "is not displayed.
g. The longest time for 2 minutes, the sound of the sound format is divided into four paragraphs
0-9 seconds: BI per second
10-19 seconds: BI BI per second, two times,
20-29 seconds: BI BI BI per second three times,
30 seconds to start BI BI BI BI four times per second, until the end of the alarm.
5. Temperature and Humidity Detection Instructions
a. Temperature range: -9.9°C to + 50°C (+ 14.1°F to + 122°F) with a resolution of 0.1 °C/°F.
b. The detection temperature is below -9.9°C (+14.1°F), which is shown as LL.L°C /°F, above +50°C
( +122°F)and is shown as HH.H °C/°F
c. Humidity detection range: 20% RH ~ 95% RH, display resolution: 1% RH
d. The detected humidity is less than 20% RH, showing 19% RH, above 95% RH, showing 96% RH.
e. The temperature detection period is 20 seconds.

Popular Clock manuals by other brands

Meinberg GPS164xHS operating instructions

Meinberg

Meinberg GPS164xHS operating instructions

La Crosse Technology 513-1419-WA user manual

La Crosse Technology

La Crosse Technology 513-1419-WA user manual

La Crosse Technology WS-8120U Quick setup guide

La Crosse Technology

La Crosse Technology WS-8120U Quick setup guide

Oregon Scientific RA383P user manual

Oregon Scientific

Oregon Scientific RA383P user manual

La Crosse Technology 404-3942 quick start guide

La Crosse Technology

La Crosse Technology 404-3942 quick start guide

Velleman WC35 user manual

Velleman

Velleman WC35 user manual

LIBERTY Health Supply TrueDio Extra Large Button Talking Clock instructions

LIBERTY Health Supply

LIBERTY Health Supply TrueDio Extra Large Button Talking Clock instructions

Rosendahl Nanosyncs user manual

Rosendahl

Rosendahl Nanosyncs user manual

Nextime WT2300 instruction manual

Nextime

Nextime WT2300 instruction manual

Pyramid 41357G instructions

Pyramid

Pyramid 41357G instructions

Braun 3855 use instructions

Braun

Braun 3855 use instructions

Ambient Weather GL152-C2 user manual

Ambient Weather

Ambient Weather GL152-C2 user manual

Daewoo DCD-200 User instructions

Daewoo

Daewoo DCD-200 User instructions

Arbiter Systems 1200B Operation manual

Arbiter Systems

Arbiter Systems 1200B Operation manual

Eurotops 45124 manual

Eurotops

Eurotops 45124 manual

Pyramid TimeTrax Clock datasheet

Pyramid

Pyramid TimeTrax Clock datasheet

Bodet Profil 730 OP quick start guide

Bodet

Bodet Profil 730 OP quick start guide

LSI LSI-6015 manual

LSI

LSI LSI-6015 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.