Elta Select Zoo Fan SDF Series User manual

t: 01384 275800
f: 01384 275810
visit: eltaselect.com
Zoo Fan SDF
Installation and Maintenance Instructions
THESE INSTRUCTIONS MUST BE READ FULLY BEFORE COMMENCING INSTALLATION.
SDF Inst Issue A: 28-08-13
CONTENTS
PAGE NO.
Electrical Data 2
Dimensional Data 2
Installation Instructions 3
General 3
Installation 3
Start Up 5
Fan Maintenance 5
Guarantee 5
Wiring Diagrams 6

EC
SDF Inst Issue A: 28-08-13
Tel: 01384 275800 Fax: 01384 275810 Email: [email protected] Visit: eltaselect.com Twitter: @eltaselect & @eltafans 2
Elta Fans Limited has a policy of continuous product development and improvement and therefore reserves the right to supply products which may differ from those illustrated and described in this publication.
Confirmation of dimensions and data will be supplied on request.
ZOO Fan SDF AC
Electrical Data
Code Supply FLC
Amps
Input
kW
Speed
r/min
Wiring
Diagram No.
SDF250/4-1AC 230V/1Ph/50Hz 0.24 0.048 1370 152-177
SDF300/4-1AC 230V/1Ph/50Hz 0.41 0.095 1230 152-177
EC
Dimensional Data
Code A B C D E F Weight
KG
SDF250 359 300 352 445 545 375 6.8
SDF300 452 367 421 533 656 460 10.5
Code Supply FLC
Amps
Input
kW
Speed
r/min
Wiring
Diagram No.
SDF250/4-1EC 200-277V/1Ph/50-60Hz 0.77 0.113 2568 152-00036
SDF300/4-1EC 200-277V/1Ph/50-60Hz 1.01 0.150 1640 152-00036

SDF Inst Issue A: 28-08-13
Tel: 01384 275800 Fax: 01384 275810 Email: [email protected] Visit: eltaselect.com Twitter: @eltaselect & @eltafans 3
Elta Fans Limited has a policy of continuous product development and improvement and therefore reserves the right to supply products which may differ from those illustrated and described in this publication.
Confirmation of dimensions and data will be supplied on request.
Heritage SGE AC EC
1.0 GENERAL
1.1 It is important these Installation and Maintenance Instructions are fully adhered to.
1.2 Full details of the unit supplied are shown on the product nameplate. If in doubt about any detail contact Elta Fans Ltd or its agents for
clarification.
1.3 All electrical installation must be carried out by suitably qualified and competent personnel in accordance with all current statutory
requirements.
1.4 These instructions cover only the Elta Fans Ltd product and do not include the supply or installation of any safety equipment that may be
required e.g. adequate guarding or protection from rotating parts and proper electrical isolation.
1.5 Any declarations made by Elta Fans Ltd about product installation and safety, are dependant on the fan equipment being used within
installations which themselves meet the requirements of the relevant Standards and Directives of your region.
1.6 The fan is designed for use in an ambient temperature of -20°C up to a maximum of +70°C (refer to the relevant table) and up to 95%
relative humidity. The fan is not suitable for corrosive or explosive atmospheres.
1.7 The installer should provide easy access to the fan to facilitate future maintenance.
1.8 The installer should ensure the fan is adequately supported.
1.9 This product is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision or instruction concerning use of the product by a person
responsible for their safety.
Children should be supervised to ensure that they do not play with the product.
1.10 At end-of-life, the unit must be disposed of in an environmentally friendly manner by suitably qualified and competent personnel in
accordance with the requirements of applicable Standards and Directive
2.0 INSTALLATION
DANGER: Rotating equipment. Death, severe injury and property damage may result. ZOO Fans are intended to be hung out-of-
reach of people. The bottom of the fan must be no less than 3.05m from any area capable of receiving pedestrian traffic.
WARNING – The fan must be isolated from the power supply during installation and maintenance. The fan must be earthed in
accordance with the local regulations.
2.1 Upon receipt, the fan equipment should be visually inspected to check for any damage. Ensure that the impeller is free to rotate.
2.2 If there are any queries concerning the fan equipment, Elta Fans Ltd should be contacted prior to the installation.
2.3 The fan must be securely mounted in the desired position to suit the application.
(Refer to Gripple Fastening Method).
2.4 Check the details on the motor rating plate to ensure that the correct power supply (voltage, frequency and phase) is available. An
incorrect power supply will lead to permanent damage to the fan motor.
2.5 Refer to the appropriate wiring diagram. Ensure that all earth connections are made.
2.6 Means for electrical disconnection must be incorporated in the wiring installation in accordance with the relevant wiring and electrical
regulations.
2.7 Precaution must be taken to locate the exhaust discharge terminal so as to avoid the backflow of gases into the room from the open flue
of gas or other fuel burning appliances.
3.0 GRIPPLE FASTENING METHOD
Using the 3m Cable with M8 Stud End Fixing, attach the Gripple to the handle of the fan.
NOTE: Gripple Installation Guidelines are included with your Gripple hardware and should be consulted for guidelines on how to install, adjust,
and care for your Gripple attachment hardware.
3.1.1 Screw regular M8 Nut to the top of the M8 Stud Fixing
3.1.2 Place M8 Flat Washer on the thread
3.1.3 Insert M8 Stud Fixing (with installed nut and flat washer) through the center hole in the handle
3.1.4 Place M8 Flat Washer and M8 Nylock Nut on thread sticking through the handle
3.1.5 Securely tighten M8 Nylock Nut
Installation Instructions

Tel: 01384 275800 Fax: 01384 275810 Email: [email protected] Visit: eltaselect.com Twitter: @eltaselect & @eltafans 4
Elta Fans Limited has a policy of continuous product development and improvement and therefore reserves the right to supply products which may differ from those illustrated and described in this publication.
Confirmation of dimensions and data will be supplied on request.
ZOO Fan SDF AC EC
SDF Inst Issue A: 28-08-13
Installation Instructions
3.2 Fasten Stabalisation Tether Gripple
Using the 4m Cable with Eyelet Fixing, attach the Gripple to the handle of the fan.
TIP: Leave the Gripple wire wound in a circle, as it is shipped, until you are ready to install the Stabilization Tether to the Truss, I-Beam, or
support structure
3.2.1 Insert proper M6 Hex Head bolt through the Eyelet of Gripple:
3.2.1a Use M6 x 50 Hex Head bolt for SDF250
3.2.1b Use M6 x 60 Hex Head bolt for SDF300
3.2.2 Insert M6 Hex Head bolt through the hole located at 45° on either side of the handle
3.2.3 Securely tighten M6 Nylock Nut
To secure the Main Hanging Gripple and Stabilization Tether to the Truss, I-Beam, or support beam.
WARNING: The Stabilization Tether MUST be installed properly to ensure safe operation of your ZOO Fan.
3.2.4 Place Gripple on the wire
3.2.5 Loop wire over Truss, I-beam, or support beam (Tether at a 45 ° angle)
3.2.6 Push end of wire into Gripple
3.2.7 Adjust wire so there is no slack

Tel: 01384 275800 Fax: 01384 275810 Email: [email protected] Visit: eltaselect.com Twitter: @eltaselect & @eltafans 5
Elta Fans Limited has a policy of continuous product development and improvement and therefore reserves the right to supply products which may differ from those illustrated and described in this publication.
Confirmation of dimensions and data will be supplied on request.
ZOO Fan SDF AC EC
SDF Inst Issue A: 28-08-13
Installation Instructions
4.0 START-UP
4.1 Before power is supplied to the unit, check that the wiring is correct as per the fan connection diagram.
4.2 At initial start-up, check that impeller rotation and airflow direction is correct.
4.3 Check that the motor amperage draw does not exceed the nameplate rating.
5.0 FAN MAINTENANCE
5.1 Inspection of the fan at least once every 12 months is recommended to ensure that the motor, fan blades, and supporting guards, are
clean. Any build up of dust and deposits on the blades or guards should be removed using a non-abrasive cleaner.
5.2 All fastenings should be checked for tightness. In addition, all rotating items should be checked.
5.3 Bearings are of the ‘sealed for life’ type and will not need a detailed inspection
WARNING – This fan is fitted with an auto-reset thermal contact which switches the fan off in the event of a fault condition.
Once the motor cools down the fan may start unexpectedly.
Only a suitably qualified and competent person may carry out maintenance after the electrical supply has been isolated.
GUARANTEE
Elta Fans Ltd will, free of charge, within a period of 1 year from the date of dispatch from their works, repair or at its option replace
any goods which are proved to have defects as a result of defective materials or workmanship. The goods MUST be returned to Elta
Fans Ltd carriage paid for examination.

SDF Inst Issue A: 28-08-13
BLUE
BROWN
BROWN
BLACK
BLUE OR GREY
GREEN/YELLOW
FAN
FAN C/W TRANSFORMER SPEED CONTROL (149-TC1_)
EL N U2 U1 AUX
N
LE
220-240V 1PH 50Hz
SUPPLY
CONTROLLER TERMINAL BOX
TO MOTOR
EL31
BLUE
BROWN
BROWN
BLACK
BLUE OR GREY
GREEN/YELLOW
FAN
FAN C/W ELECTRONIC SPEED CONTROL (149-EL31)
N/
U2
L/
U1
TO MOTOR
N/
U2
L/
U1
CONTROLLER TERMINAL BOX
220-240V 1PH 50Hz
SUPPLY
EL N
NLENL AUX
BROWN
BLACK
BLUE OR GREY
GREEN/YELLOW
PENL
230V 1PH 50Hz SUPPLY
TO MOTOR
FAN ONLY
5N LGND6 4
N L E
220-240V 1PH 50Hz
SUPPLY
CONTROLLER TERMINAL BOX
TO MOTOR
EL21
BLUE
BROWN
BROWN
BLACK
BLUE OR GREY
GREEN/YELLOW
FAN
FAN C/W ELECTRONIC SPEED CONTROL (EL21)
N/
U2
L/
U1
N/
U2
L/
U1
ALL WIRING AND CONTROL EQUIPMENT MUST COMPLY TO THE
LATEST IEE REGULATIONS, IN PARTICULAR PART 552-01-02/03
11/07/2013
MK-152-177 Issue: Saved Date:
B
Tel: 01384 275800 Fax: 01384 275810 Email: [email protected] Visit: eltaselect.com Twitter: @eltaselect & @eltafans 6
Elta Fans Limited has a policy of continuous product development and improvement and therefore reserves the right to supply products which may differ from those illustrated and described in this publication.
Confirmation of dimensions and data will be supplied on request.
ZOO Fan SDF
Wiring Diagrams
152-177
AC

SDF Inst Issue A: 28-08-13
BLUE
RED
WHITE
YELLOW
BROWN
BLUE
GREEN/YELLOW
TO MOTOR
200-277V 1PH 50/60Hz
SUPPLY
FAN ONLY
FAN
NL E1 A1 GND 10V
L N
FAN C/W POTENTIOMETER SPEED CONTROL (149-POT-10)
NL E1 A1 GND 10V
1 2 7 6 5
L N
RED
BLUE
WHITE
YELLOW
BROWN
BLUE
GREEN/YELLOW
149-POT-10
TO MOTOR
200-277V 1PH 50/60Hz
SUPPLY
FAN
ALL WIRING AND CONTROL EQUIPMENT MUST COMPLY TO THE
LATEST IEE REGULATIONS, IN PARTICULAR PART 552-01-02/03
11/07/2013
MK-152-00036 Issue: Saved Date:C
Tel: 01384 275800 Fax: 01384 275810 Email: [email protected] Visit: eltaselect.com Twitter: @eltaselect & @eltafans 7
Elta Fans Limited has a policy of continuous product development and improvement and therefore reserves the right to supply products which may differ from those illustrated and described in this publication.
Confirmation of dimensions and data will be supplied on request.
ZOO Fan SDF EC
152-00036

EC Declaration of Conformity
Designation of Equipment:
Raptor, Compact, Powerplus, Revolution, Miniflow, Multiflow,
Viper, Jetflow, Jetstream, Hideaway, Singleflow, Quietflow,
Twinflow, Powerduct, Qube, Slim-Qube, Skyflow, Heritage,
Biflow, Zoo Fan, Ceiling Fan, SmokeVent, Pedestal, Window/
Wall, Ezifit
Type:
SPA, SDA, SCP, SCPA, SCD, SCPP, SPP, SLC, SAMF, SMB,
SMC, SMT, SCC, HIT, SJS, SH, SSD, SQS, SQSDCV,STD,
SQT, SQTDCV, SPD, SQU, SQU-HT, SSQU, SSR, SSF,
SSMF, SMF, SSDR, SSDRDCV, STDR, STDRDCV, SGE, SCH,
SCHT, SSFV, SSRV, SSC, SB, SDF, HCF, HPFA, HWFA, SRC,
SAX, SRE, SEIE, SEWE
Low Voltage Directive2006/95/EC
Electromagnetic Compatibility (EMC) Directive 2004/108/EC
Energy-Related Products (ErP) Directive 2009/125/EC
Herewith declare that the air movement equipment below, on
the basis of its design and construction as partly completed
machines brought onto the market is in compliance within rele-
vant health and safety requirements of the EC Directives stated
above. In the event that alterations are made to the machinery
without prior consent with the manufacturer, this declaration
becomes invalid.
EC Declaration of Incorporation
In accordance with the Machinery Directive 2006/42/EC
Designation of Equipment:
Raptor, Compact, Powerplus, Revolution, Miniflow, Multiflow,
Viper, Jetflow, Jetstream, Hideaway, Singleflow, Quietflow,
Twinflow, Powerduct, Qube, Slim-Qube, Skyflow, Heritage,
Biflow, Zoo Fan, Ceiling Fan, SmokeVent, Window/Wall, Ezifit
Type:
SPA, SDA, SCP, SCPA, SCD, SCPP, SPP, SLC, SAMF, SMB,
SMC, SMT, SCC, HIT, SJS, SH, SSD, SQS, SQSDCV,STD,
SQT, SQTDCV, SPD, SQU, SQU-HT, SSQU, SSR, SSF,
SSMF, SMF, SSDR, SSDRDCV, STDR, STDRDCV, SGE, SCH,
SCHT, SSFV, SSRV, SSC, SB, SDF, HCF, SEIE, SEWE
The design of the partly completed machines listed below
complies with the Essential Health and Safety Requirements
(EHSRs) of ANNEX I, sections 1.1.2, 1.1.5, 1.4.1, 1.5.1 in EC
Machinery Directive 2006/42/EC
The partly completed machines comply with the requirements
of :- Low Voltage Directive 2006/95/EC, Electromagnetic
Compatibility (EMC) Directive 2004/108/EC, Energy-Related
Products (ErP) Directive 2009/125/EC
The machinery is incomplete and must not be put into service
until such time as the machinery which is partly complete is to
be incorporated and has been assessed and declared in con-
formity with the provisions of the Machinery Directive 2006/42/
EC.
We undertake to transmit, upon reasoned request by appro-
priate national authorities, relevant information on the partly
completed machinery identified above.
Manufacturer:
Elta Fans Limited
17 Barnes Wallis Road
Segensworth East Industrial Estate
Fareham, Hampshire
PO15 5ST, UK
Date / Signature of Manufacturer: Date: 20th May 2013
Name / Position of Signatory: Mr. Robert Rees Q.A.Manager Elta fans Ltd,
EC DECLARATION OF
CONFORMITY/INCORPORATION
Herewith we declare that the air movement equipment below, on the basis of its design and construction in the form brought onto
the market is in accordance within the relevant health and safety requirements of the EC Directive for
use of machinery.
Issuer: Bob Rees Issue A Date: 20th May 2013

A member of
HEVAC ASSOCIATION
BS EN ISO 9001:2008
FM 556465
GROUP LIMITED
A member of
www.eltafans.com
BUILDING SERVICES
Tel: +44 (0) 1384 275800
Fax: +44 (0) 1384 275810
e-mail: [email protected]
46 Third Avenue
Pensnett Trading Estate
Kingswinford, West Midlands
DY6 7US, United Kingdom
APPLIED TECHNOLOGY
Tel: +44 (0) 1489 566500
Fax: +44 (0) 1489 566555
e-mail: [email protected]
17 Barnes Wallis Road
Segensworth East Industrial Estate
Fareham, Hampshire
PO15 5ST, United Kingdom
EXPORT
Tel: +44 (0) 1489 566500
Fax: +44 (0) 1489 566555
e-mail: [email protected]
17 Barnes Wallis Road
Segnesworth East Industrial Estate
Fareham, Hampshire
PO15 5ST, United Kingdom
This manual suits for next models
4
Table of contents
Other Elta Select Fan manuals
Popular Fan manuals by other brands

Ebmpapst
Ebmpapst W1G200-EC95-17 operating instructions

System air
System air AW 315E4 operating instructions

Ebmpapst
Ebmpapst R1G190-AB27-02 operating instructions

Bigassfans
Bigassfans Haiku 60 installation guide

Ebmpapst
Ebmpapst R2E220-RA44-10 operating instructions

System air
System air EX 140A Operation and maintenance instructions

DesignHouse
DesignHouse 154070 Owner's instruction manual

Super Vac
Super Vac V20-GB user guide

Casa Fan
Casa Fan ECO GAMMA 103 Mounting and operating manual

Ebmpapst
Ebmpapst A3G710-AO81-01 Operating instruction

Ebmpapst
Ebmpapst R3G250-PR02-J1 operating instructions

Ebmpapst
Ebmpapst S4E350-AA06-24 operating instructions