manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Emay
  6. •
  7. Monitor
  8. •
  9. Emay SleepO2 User manual

Emay SleepO2 User manual

SleepO2
Sleep Oxygen Monitor
User Manual
Thisproductisintendedonlyforgeneralwellnessuse.Itisnotamedical
device and should not be used to diagnose or treat any medical
condition.
1. Introduction
1.1 Warnings and Cautions
DO NOT squeeze the sensor part or apply excessive force
on it.
Do not use this device during MRI examination.
Never submerge the device in water or other liquids. Do not
clean the device with acetone or other volatile solutions.
Do not place this device in pressure vessels or gas
sterilization device.
Consult your doctor immediately if you experience
symptoms that could indicate acute disease.
Do not self-diagnose or self-medicate on the basis of this
device without consulting your doctor. In particular, do not
start taking any new medication or change the type and/or
dosage of any existing medication without prior approval.
Use only cables, sensors and other accessories specified in
this manual.
Prolonged continuous monitoring may increase the risk of
undesirable changes in skin characteristics, such as irritation,
reddening, blistering or burns.
1.2 Unpacking
Main Unit × 1
Charging Cable × 1
User Manual × 1
1.3 Overview
Wear the device during sleep. It protects you
from oxygen shortage by Smart Vibration.
Oxygen drop Smart Vibration Oxygen recover
Next morning, you can get the sleep results and
O2 Score in App to help you track.
You can customize Smart Vibration in App to
help you sleep better.
2 Using the Monitor
2.1 Download App
App name: Check O2
iOS: App Store
Android: Google Play
2.2 Charging
Charge the battery before using.
Connect the device to USB of computer or USB
charging adapter.
After fully charged, the device will power off
automatically.
2.3 POWER ON/OFF
POWER ON:
Press the button on the side for 1 second to turn on
the device.
POWER OFF:
Recommended way: device turns off automatically
in 2 minutes if no measurement, no operation,
without App connection.
Manually: press the button for about 2 seconds to
turn off.
2.4 Typical steps
START. Charge the battery.
Wear the device, press the
button to power on. Go to sleep.
STOP. Next morning, takeoff the
device, the recording will be over
after the countdown.
DATA SYNC. After the
countdown, run App to sync
data. Check results in App.
2.5 Start monitoring
1) Wear the device on the
forefinger. If it is too tight,
try another finger.
2) Turn on the device. After a
few seconds, the device will begin to monitor.
(If the working time is less than 1 minute, the
data will not be saved)
Note:
•Please avoid excessive motion for the sensed finger during
recording and avoid any strongambientlight condition.
2.6 Stop monitoring & sync data
Take off the device, the countdown
will begin.
(If the working time is less than 1 minute, there will
be no countdown)
During the countdown, if you wear the device again,
the record will be resumed.
After the countdown, the data will be ready for
sync.
Sync data:
1) After the countdown, run App to sync data;
2) Or next time after you turn on the device, run
App to sync.
Note: The device can store maximum 4 records.
The oldest record will be overwritten when the 5th
record is coming in. Please sync data to your phone
in time.
TM
2.7 Display
Time, Remaining battery capacity
SPO2
Blood oxygen saturation
Heart rate
Wear the device
O2 Score, SpO2drop times
During measurement, press the button, you can
switch different displays.
2.8 Bluetooth Connection
The device Bluetooth will be enabled automatically
only when the screen lights up.
To establish a Bluetooth connection,
1) Ensure the device screen is on to keep the
device Bluetooth enabled.
2) Make sure the phone Bluetooth is enabled.
3) Run the App, then select the Device ID for the
initial use.
Note: DO NOT PAIR in the settings of your
smartphone.
2.9 Real-time Dashboard
You can check real-time SpO2, Heart Rate in App.
1) Connect device to App.
2) App->Dashboard.
2.10 Smart Vibration
The vibrator in the sensor will be activated when the
SpO2fall below the pre-set value (Threshold). The
vibrationwill stop when the SpO2recover, or you can
press the button to stop it.
You can customize the vibration to help you sleep
better. Make sure your device is connected to App
first. Then you can configure it in App->Device.
•You can switch on or off the vibration.
•You can adjust the Intensity of vibration.
•You can adjust the Threshold. If the vibration
disturbs you during sleep too much, you can
lower the Threshold. If you would like to get
more protection from oxygen shortage, you
can turn up the Threshold.
2.11 View Results and Report
In App, you can review all
the history data. Touch a
record, there comes out the
detailed report, which
includes analysisresults and
charts.
Slide a record to left, you can delete it.
2.12 O2 Score
O2 Score is overall assessment of oxygen condition,
which synthesizes the frequency, depth and
duration of oxygen shortage overnight. The range is
0-10 (10 is best). It is provided for each record in
App.
Example:
3 Maintenance
3.1 Cleaning
Use a soft cloth moistened with water or alcohol to
clean the device surface.
3.2 Firmware Update
1) Connect the monitor with theAPP.
2) Enter the APP, visit Device Device Update.
Check the version and start an update if you
want.
3.3 Battery
To keep the battery in good condition, charge the
battery every 6 months when the device is not in use.
4 Troubleshooting
Problem
Possible Cause
Possible
Solution
Device
does not
turn on
or no
response
Battery may be low.
Charge battery
and try again.
Unexpected
software condition
Press the button
for about 10
seconds to reset
Device might be
damaged.
Please contact
your local
distributor.
The app
cannot
find the
device
The Bluetooth of
your phone is off.
Turn on the
Bluetooth in the
phone.
The device
Bluetooth is off in
Sleep Mode.
Press the button,
the Bluetooth will
be turned on
when the screen
lights up.
5 Specifications
Weight
18g
Size
44×25×17 mm (main unit)
Battery
Rechargeable Lithium-polymer
Charge time
2-3 hours
Wireless
Bluetooth 4.0 BLE
Oxygen level
range
70% to 100%
Heart Rate range
30 to 250 bpm
Vibration
Trigged by low oxygen level
Recorded
parameters
Oxygen Level, heart rate, motion
Data storage
4 records, up to 10 hours for
each
Mobile App for iOS
iOS 9.0 or above,
iPhone 4s/iPad 3 or above
Mobile App for
android
Android 4.4 or above,
with Bluetooth 4.0 BLE
Model: Oxiband-1
Version:A
O2 7.5 13
18:45
Z
0 10
O2 Score 7.5 (in the APP)
FCC Statement
15.19
1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including interference that may cause
undesired operation.
15.21
Note: The grantee is not responsible for any changes or modifications not expressly approved by
the party responsible for compliance. Such modifications could void the user’s authority to operate
the equipment.
15.105(b)
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation.
This equipment generates uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
-Consult the dealer or an experienced radio/TV technician for help

Popular Monitor manuals by other brands

BenQ FP951 user manual

BenQ

BenQ FP951 user manual

Asus VB171D - 17" LCD Monitor Service manual

Asus

Asus VB171D - 17" LCD Monitor Service manual

Hanns.G HH191DP Specification sheet

Hanns.G

Hanns.G HH191DP Specification sheet

Philips 105S51 Specifications

Philips

Philips 105S51 Specifications

Daisy 4823DH user manual

Daisy

Daisy 4823DH user manual

LG 38WP85C-W owner's manual

LG

LG 38WP85C-W owner's manual

Iiyama ProLite X2377HDS user manual

Iiyama

Iiyama ProLite X2377HDS user manual

Sony SDM-H246W operating instructions

Sony

Sony SDM-H246W operating instructions

Envision G2470 manual

Envision

Envision G2470 manual

Acer 193199140210 user guide

Acer

Acer 193199140210 user guide

Sharp LL-S242A-W Setup manual

Sharp

Sharp LL-S242A-W Setup manual

LG 34UM88 owner's manual

LG

LG 34UM88 owner's manual

Voxx Electronics Rostra Accessories 250-8222 installation guide

Voxx Electronics

Voxx Electronics Rostra Accessories 250-8222 installation guide

LG 55MH5K owner's manual

LG

LG 55MH5K owner's manual

Atlantis Land I-See S150 LCD Monitor A05-15AM-C01 specification

Atlantis Land

Atlantis Land I-See S150 LCD Monitor A05-15AM-C01 specification

AUREL Magna Series manual

AUREL

AUREL Magna Series manual

AOC 24V5C/BK user manual

AOC

AOC 24V5C/BK user manual

Samsung PL-50P3H Owner's instructions

Samsung

Samsung PL-50P3H Owner's instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.