manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. EMC
  6. •
  7. Monitor
  8. •
  9. EMC EMC-DMA-2.0 Manual

EMC EMC-DMA-2.0 Manual

Installation & Operating Instructions
EMC-DMA-2.0
Energy Management Consultants, 1550 La Follette Street, Fennimore, WI 53809
Tel. +1-608-822-3550 • Fax +1-608-822-3847 • E-mail: [email protected] • Web: www.emccontrols.com
Specications subject to change without notice.
rev. 04/15/19
43273_ins_DMA_2.0
1 of 4
Product Identication and Overview
Specications
Fig. 2: DMA-2.0
Mounting Diagram
The DMA-2.0 is a door monitor assembly that monitors a
door switch. Green, amber, and red LEDS on the face of
the unit indicate whether the door is closed, open, or has
exceeded its user-selectable open time period.
Leaving the door open for more than the user-selected time
will also energize a buzzer to alert personnel nearby that the
door should be closed immediately. The unit also contains
two auxiliary relays that will energize whenever the door is
opened to alert other user-supplied warning devices or a
building automation system.
A green LED inside the unit illuminates whenever power is
present and red LEDs illuminate when the auxiliary relays
are energized to assist with installation and troubleshooting.
The unit is powered by 24 VAC or 24 VDC.
Supply Power: 24 VAC or 24 VDC (UL Listed Class 2 Power Source only)
Power Consumption (max): 7.5 VA @ 24 VAC, 200 mA @ 24 VDC
Auxiliary Relay Contact Rating: 1.0 Amp @ 30V AC/DC
Wire Size: 14 to 22 AWG
Door Switch: Normally closed (NC)
Environmental Operation Range:
Temp: 0° to 60°C (32 to 140°F)
Humidity: 5% to 95% RH non-condensing
Mounting
Fig. 1: DMA-2.0 Unit
Installation & Operating Instructions
EMC-DMA-2.0
Energy Management Consultants, 1550 La Follette Street, Fennimore, WI 53809
Tel. +1-608-822-3550 • Fax +1-608-822-3847 • E-mail: [email protected] • Web: www.emccontrols.com
Specications subject to change without notice.
rev. 04/15/19
43273_ins_DMA_2.0
2 of 4
Termination
Operation
All terminal blocks are removable/
pluggable connectors.
14 to 22 AWG wire is required for all
connections.
Power: 24 VAC or 24 VDC
(UL Listed Class 2 Power Source only)
Door Switch: Connection is not
polarized.
Auxiliary Relays: Can be connected
as either normally open (NO) or
normally closed (NC).
Buzzer: Remove the cover sticker
prior to use.
Fig. 3: DMA -2.0
Circuit Board
Basic Operation:
When the door opens, the Door Switch input terminals create an open circuit. The Door Status LEDs on the face
of the unit will change color, both Auxiliary Relays will energize (providing dry contact outputs), and both Auxiliary
Relay LEDs will illuminate. If the door stays open longer than the Door Timer Interval setting, the buzzer will sound.
Closing the door will de-energize both of the Auxiliary Relays, silence the buzzer if it is on, and change the color of
the Door Status LEDs.
The Auxiliary Relays are energized whenever the door is open and de-energized whenever it is closed.
The Door Status LEDs on the face of the unit change colors depending on the conditions listed in the table below.
Door Status Additional Condition User Action
Green Solid Closed
N/A None.
Amber Flashing Open Door timer interval has not been exceeded. Close the door when completed with your work.
Amber Solid Closed 5 minute Buzzer Reset Interval has not expired. Avoid opening the door until the LEDs turn green.
Red Flashing Open Door timer interval exceeded. Close the door as soon as possible.
Color
Door Status LEDs (located on the face of the unit)
Door Internal Timer:
The user can select how long the door can be continuously open before the buzzer
sounds and the status LEDS turn red. Figure 4 shows the allowable settings. If the
switch is in one of the blank positions, it uses 1 min.
Fig. 4: Door Timer
Interval Rotary
Switch (S1)
Auxiliary Relay
Connections
Power Connection Power On
LED (green)
Relay LEDs (red) Door Switch
Connection
Remove
Sticker Prior
to Use!
Installation & Operating Instructions
EMC-DMA-2.0
Energy Management Consultants, 1550 La Follette Street, Fennimore, WI 53809
Tel. +1-608-822-3550 • Fax +1-608-822-3847 • E-mail: [email protected] • Web: www.emccontrols.com
Specications subject to change without notice.
rev. 04/15/19
43273_ins_DMA_2.0
3 of 4
Operation continued...
Buzzer Reset Interval - 0 min or 5 min RESET (Switch 2 of DIP Switch S2)
If the switch is set in the “ON” position, then the Reset = 0 minutes
and the buzzer timer resets immediately after the door is closed. This
essentially means that there is no waiting period before you should
open the door again. The buzzer will not sound again unless the door is
opened for longer than the Door Timer Interval rotary switch setting.
If the switch is set in the “OFF” position, then the Reset = 5 minutes
and the buzzer timer will not reset until the door has been closed for
more than 5 minutes. This means that if the door has been open for
longer than the Door Timer Interval rotary switch setting and the buzzer
sounds, then closing the door will silence the buzzer BUT NOT reset the
buzzer timer. The buzzer will immediately sound if the door is opened
any time within the next 5 minutes. Each time the door is opened during
this period, a new 5 minute “count down” period is started. The Door Status LEDs will change to green once the 5
minute period has expired.
Door Timer Interval - SECONDS or MINUTES (Switch 3 of DIP Switch S2)
Normal operation is set to “OFF” - MINUTES.
For a quick condence test, this switch can be set to SECONDS by placing it to the “ON” position. This means that
the buzzer will sound after 1 to 30 seconds (depending on the rotary switch settings) rather than 1 to 30 minutes.
This switch also changes the Buzzer Reset Interval from minutes to seconds (5 min RESET now equals 5 seconds
RESET).
Operational Test - OPERATE or TEST (Switch 4 of DIP Switch S2)
Used to test all of the output combinations of the DMA-2.0.
NOTE: The test mode disables door monitoring.
1. Set DIP switch (S2) to TEST.
2. Set rotary switch (S1) to the positions in the Operational Chart below to conrm that the unit’s output matches
those listed in the table.
3. Return the unit to normal operation by setting DIP switch to OPERATE and rotary switch (S1) to its intended time.
Rotary Switch
(S1) Position
Power
LED
Both Relay
LEDs
Both Relays
Door Status
LEDs
Buzzer
1 min On Off De-energized Solid green Silent
5 min
On
On
Energized
Flashing amber
Silent
10 min On On Energized Flashing red Sounding
15 min
On
Off
De-energized
Solid amber
Silent
20 min On Off De-energized Solid red Silent
25 min On Off De-energized All off Silent
Operational Chart
Fig. 5: DIP Switches (S2)
Installation & Operating Instructions
EMC-DMA-2.0
Energy Management Consultants, 1550 La Follette Street, Fennimore, WI 53809
Tel. +1-608-822-3550 • Fax +1-608-822-3847 • E-mail: [email protected] • Web: www.emccontrols.com
Specications subject to change without notice.
rev. 04/15/19
43273_ins_DMA_2.0
4 of 4
Diagnostics
Possible Problems:
Power LED (PWR1) does not light
Door Status LEDs indicate the
wrong status
Door Status LEDs do not change
Door Status LEDs do not come on
Possible Solutions:
Conrm that there is 24 VAC or 24 VDC at connector TB1 and that the
polarity is correct.
Make sure that the unit is in Operate mode, not Test mode (DIP Switch S2).
Conrm that the door switch is wired as a Normally Closed (NC) connection
(a closed door equals an open circuit).
Check for loose or shorted wires at the Door Switch connection.
Make sure that the unit is in Operate mode, not Test mode (DIP Switch S2).
Conrm that the unit is powered correctly. Power LED should be on.
Make sure that the unit is in Operate mode, not Test mode (DIP Switch S2).
Run the Operational Test described on page 3 to conrm that the LEDs,
relays or buzzer are not burned out.

Popular Monitor manuals by other brands

Kason 1967-A2 installation instructions

Kason

Kason 1967-A2 installation instructions

Tektronix WFM7200 manual

Tektronix

Tektronix WFM7200 manual

Akron OMEGA XP 3528 Installation, operating and maintenance instructions

Akron

Akron OMEGA XP 3528 Installation, operating and maintenance instructions

Eizo FlexScan SX2461W-BK Setup manual

Eizo

Eizo FlexScan SX2461W-BK Setup manual

ViewSonic VS16800 user guide

ViewSonic

ViewSonic VS16800 user guide

Elo TouchSystems Elo Entuitive 3000 Series 1739L user guide

Elo TouchSystems

Elo TouchSystems Elo Entuitive 3000 Series 1739L user guide

DCLCD DCL22 user manual

DCLCD

DCLCD DCL22 user manual

Philips Brilliance S221C4AFD user manual

Philips

Philips Brilliance S221C4AFD user manual

Ikegami HTM-1005R Operation manual

Ikegami

Ikegami HTM-1005R Operation manual

ViewSonic VX2262WM - 22" LCD Monitor Manual de utilizare

ViewSonic

ViewSonic VX2262WM - 22" LCD Monitor Manual de utilizare

Siebert Series S102 operating instructions

Siebert

Siebert Series S102 operating instructions

Dell E178FPC Service manual

Dell

Dell E178FPC Service manual

Moxa Technologies MD-200 Series Quick installation guide

Moxa Technologies

Moxa Technologies MD-200 Series Quick installation guide

Panasonic PT-44LCX65 - 44" Rear Projection TV Service manual

Panasonic

Panasonic PT-44LCX65 - 44" Rear Projection TV Service manual

OPTICOM LCDI-104 - datasheet

OPTICOM

OPTICOM LCDI-104 - datasheet

Philips 107E63 user manual

Philips

Philips 107E63 user manual

LG MK4 Series quick start guide

LG

LG MK4 Series quick start guide

ViewSonic VCDTS21468-1 user guide

ViewSonic

ViewSonic VCDTS21468-1 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.