EMCT RP 100 6 User manual

Zertifizierungsstelle
SIBE Schweiz
Instruction manual for
RP 100 6 EMCT Electronic Test Buzzer
1
Battery box
2
Test buzzer
3
Measuring line
4
Test terminal
5
Pluggable test terminal
Table of contents
1Introduction...........................1
1.1 Application..............................1
1.2 Remarks .................................1
1.3 Scope of delivery ....................2
2Safety instructions................2
3Instruction.............................2
3.1 Bringing into service ............... 2
3.2 Continuity check..................... 2
4Maintenance.......................... 3
4.1 Battery change ....................... 3
5Technical data....................... 3
EC Declaration of Conformity.............. 4
1 Introduction
1.1 Application
The RP 100 6 Electronic Test Buzzer can be used for the ohmic continuity check of switches,
lines, circuits, fuses, lamps, diodes, transistors, polarity tests, coils, resistors, transformers,
relays and contractors. Resistance test range is between 0 and 1 kΩ.
Protected against external voltage
Test range: low or high ohmic
Test terminal pluggable
Red plastic housing shockproof
1.2 Remarks
In this instruction manual noted remarks:
Warning:
Warns of a danger which could bring injuries.
Indication:
Has to be considered!
Important:
Important information!
1
2
3
5
4

RP 100 6 Bedienungsanleitung eng Seite 2 von 4
1.3 Scope of delivery
Included in delivery is:
1x RP 100 6 EMCT Electronic Test Buzzer
1x pluggable test terminal
1x instruction manual
2 Safety instructions
The remarks noted in this instruction manual are inevitable for a save application of
the test buzzer. You are advised not to use the test buzzer before reading the safety
instructions. Disobeying the instructions can result in injury!
The test object has to be in a tensionless state.
The test buzzer is not qualified to be used in energized objects.
The measuring lines and test terminals may only be touched at the intended
handles.
The test buzzer may only be used in the denoted test ranges.
Before opening the battery box the test buzzer has to be disconnected from all the
measuring circuits.
For use by competent persons only. Anyone using this Product should be
knowledgeable and trained about the risks involved with measuring voltage,
especially in an industrial setting, and the importance of taking safety precautions
and of testing the Product before and after using it to ensure that it is in good
working condition.
The test buzzer has to be placed out of children’s reach.
3 Instruction
3.1 Bringing into service
Before bringing the test buzzer into service you have to insert a 9 V block battery (IEC 6 F
22). Proceed as indicated in 4.1.
3.2 Continuity check
The test buzzer permits a simple and fast continuity check by recognizing a closed circuit
and giving off an acoustic signal. Thanks to that one doesn’t have to take a look at the test
buzzer during the check. The acoustic signals sound different when there is a different
resistance value.
Proceed as indicated below:
Connect the test terminals with the testing object at two points you want to check.
If there is continuity you will hear the acoustic signal.

RP 100 6 Bedienungsanleitung eng Seite 3 von 4
Make sure that the testing object is in a tensionless state and do not use the test
buzzer around wet environments. Additionally you have to make sure that the
measuring lines are in a flawless condition.
The test buzzer confirms continuity with an acoustic signal of 70 dB(a) at a distance
of 22 cm.
4 Maintenance
When the test buzzer is used according to the instruction manual no particular maintenance
is required. It is still possible that the test buzzer gets dirty from time to time. If this is the
case the battery box can be cleaned with a moist towel and a little bit of mild household
cleaner.
4.1 Battery change
After some time of use the battery needs to be changed. This will be recognized when the
test buzzer doesn’t work flawlessly anymore.
After you have disconnected the test buzzer from all the measuring circuits, proceed as
indicated below:
1. Open the battery box as showed on the picture below.
2. Remove the old battery and insert the new 9 V block battery (IEC 6 F 22) poled
correctly.
3. Close the battery box.
Dispose the old battery appropriately.
The battery should be removed if the test buzzer is not being used during a longer
period of time.
5 Technical data
Currant over test terminal
24 mA (1 kΩ)
Voltage over test terminal
9 V
Resistance test range
0 - 1 kΩ
Protected against external
voltage up to
36 V AC
Intermittent alarm by
alternating voltage
No
LED visual indication
No
Battery
9 V (IEC 6 F 22)
Length of test cable
1 m
Temperature range
-5°C to +50°C
Life expectancy
10 years
Sign of conformity, approves compliance of the valid EMC directive (2014/30/EU). The
device is in compliance with the following standards: EN ISO 12100, EN 60204-1, EN
61000-6-2, EN 61000-6-4, low voltage directive (2014/35/EU).

RP 100 6 Bedienungsanleitung eng Seite 4 von 4
EC Declaration of Conformity
(Directive 2006/42/EG, Annex II A)
The producer: EMCT Swiss-ConnTec SA, Grubenstrasse 7a, CH-3322 Schönbühl
herewith declares, that the following device:
EMCT Electronic test buzzer / RP 100 6 / 10-4-0110
is in conformity with the essential requirements of security and health of the machinery
directive 2006/42/EG Annex I.
The device is in conformity with the following additional directives:
Low voltage directive 2014/35/EU
EMC directive 2014/30/EU
The following harmonised standards were applied:
EN ISO 12100; EN 60204-1; EN 61000-6-2; EN 61000-6-4
Authorized representative for the composition of the technical documents:
Christoph Müller
Grubenstrasse 7a
CH-3322 Schönbühl
According to the needs of a national agency the technical documents will be transmitted as
an electronic file.
Schönbühl, 21.01.2015 EMCT Swiss-ConnTec SA
Christoph Müller Robert Müller
Managing Director Quality Assurance Manager