Emjoi AP17LTR User manual

BodyBare Perfection
cordless epilator & shaver with manual
precission tweezers
Instruction Booklet
AP17LTR
Please read these instructions carefully
and retain for future reference.

Contents
Sunbeam’s Safety Precautions 4
Features of your BodyBare Perfection epilator 6
Using your BodyBare Perfection epilator 7
Using your shaver head attachment 8
Using your Manual Precision Tweezers 9
Spotlight Battery Replacement 9
Care and Cleaning 10
Help Line 11
Epilator Unit Battery Disposal 11

Important instructions – retain for future use.

Ensure that the above safety precautions are understood
We are very safety conscious when designing and manufacturing
consumer products, but it is essential that the product user also exercise
care when using an electrical appliance. Listed below are precautions
which are essential for the safe use of an electrical appliance:
• Read carefully and save all the instructions provided with an
appliance.
Safety Precautions for your Emjoi BodyBare epilator
• Keep out of the reach of children.
• Do not use if the tweezers are broken or damaged.
• The appliance must only be used as described in this booklet.
• This appliance is for household use only.
• Do not immerse the product in water or any other liquid.
• If you suffer from any of the following conditions, please see your
health care provider before using your BodyBare epilator – acne,
moles, diabetes, during pregnancy, eczema, hemophilia, immune
deficiency, psoriasis, varicose veins or wounds.
• Do not use this unit where it can come into contact with the scalp,
clothing and shoelaces to avoid personal injury and damage to the
unit.
• Use only on clean, dry skin.
• This product has not been designed for use on the eyebrows.
• Use only with the adaptor supplied with this appliance.
• As this is a personal care product, we recommend that it is used
by one person only.
Note: Use of an epilator may cause reddening or irritation of the skin.
This is a normal reaction which will quickly disappear. However
if the irritation remains for more than three days, please see your
health care practitioner.
Emjoi’s Safety Precautions
4

• Always turn the power off at the power outlet before you insert or
remove a plug. Remove by grasping the plug - do not pull on the
cord.
• Turn the power off and remove the plug when the appliance is not
in use and before cleaning.
• Do not use your appliance with an extension cord unless this cord
has been checked and tested by a qualified technician or service
person.
• Always use your appliance from a power outlet of the voltage (A.C.
only) marked on the appliance.
• This appliance is not intended for use by young children or
infirm persons unless they have been adequately supervised by a
responsible adult to ensure that they can use the appliance safely.
• Young children should be supervised to ensure that they do not
play with the appliance.
• Never leave an appliance unattended while in use.
• Do not use an appliance for any purpose other than its intended
use.
• Do not place an appliance on or near a hot gas flame, electric
element or on a heated oven. Do not place on top of any other
appliance.
• Do not let the power cord of an appliance hang over the edge of a
table or bench top or touch any hot surface.
• Do not operate any electrical appliance with a damaged cord or
after the appliance has been damaged in any manner. If you have
any concerns regarding the performance and use of your Emjoi
appliance, please contact the Sunbeam Customer Service Centre.
• For additional protection, Sunbeam recommend the use of a
residual current device (RCD) with a tripping current not exceeding
30mA in the electrical circuit supplying power to your appliances.
• Do not immerse the appliance in water or any other liquid unless
recommended.
• WARNING: Keep the appliance dry.
Ensure that the above safety precautions are understood
5

Features of your BodyBare
Perfection Epilator
30 tweezers
Spotlight
On/Off Button
Charging indicator
Adaptor
Protective Cover
Shaver head
attachment
Head release button
2 speed settings
Manual Precision
Tweezers
Spotlight On/Off
Button
Cleaning brush
6

Using your BodyBare epilator
Before using your epilator for the first time
• This epilator must be fully charged before using for the first time.
• This reach optimum recharge capacity, the batteries should initially be
charged for 16 hours. Do not recharge for longer than this.
• The charging indicator light will light up to show you that the unit is
charging.
• On subsequent charging, you should recharge for 14-16 hours.
This will provide up to 40 minutes of cordless use.
• Ensure that the epilator is switched off. Insert the charging lead into the
adaptor inlet, plug the adaptor into a suitable mains outlet and switch on.
• When the batteries are run down, it is possible to use this appliance from
the mains via an adaptor. However frequent use of the epilator
as a corded unit is not recommended.
• To extend the life of the epilator we recommend that you fully drain the
batteries every six months.
Using your Epilator
• Before using your BodyBare epilator for the first time, we recommend that
you familiarise yourself with how the appliance feels on the skin.
Try the unit on the back of the hand before using it on delicate areas such
as the face.
• We recommend that you have a warm shower or bath before use and use a
loofah or exfoliating cream to prepare the skin.
• Ensure that the skin is clean and dry. Do not use over body lotions or
moisturises.
• Attach the adaptor to the unit, plug in, remove the protective cover and
switch on.
• Silver lon technology provides anti bacterial protection.
• There are two settings. Use setting I on fine hair and setting II on thicker
or coarser hair.
• When removing hair it is very important to hold the skin very taut to avoid
pinching.
• If hair is longer than 5mm, trim with scissors before use.
7

• Hold at a 90 degree angle to the area you wish to remove hair from with
the BodyBare logo facing away from you.
• Move the appliance in rapid circles, lightly gliding over the skin. There is
no need to apply pressure.
• If too much pressure is applied, the appliance may slow down.
• The appliance is designed to be used on hair as short as 0.5mm so there
is no need for stubble to appear before epilating.
• The appliance can be used on the legs, bikini line, underarms and face.
• The Emjoi BodyBare Perfection is only intended to remove single hairs
from the upper lip and chin. Hold area taut and use a small brushing
motion.
• The appliance is not suitable for use on the eyebrows.
• To turn the spotlight on for epilator use, press the spotlight on/off button
once and the light will come out from the epilator head. To turn off, press
the button once again.
• The manual precision tweezers must be inside the epliator to operate the
spotlight.
• The spotlight will automatically turn off after approximately 7 minutes.
Using your shaver head attachment
• The shaver head is ideal to use on more sensitive areas such as bikini line,
underarms or for quick touchups.
• Press the head release button and pull off the epilator head. Attach the
shaver head and click into position.
• Important: The shaver head should only be used at the higher speed
setting.
Using your BodyBare epilator continued
8

Using your Manual Precision Tweezers
• Remove the tweezers from the bottom of the epilator by pressing the
tweezer button. The tweezers will pop out.
• Turn the spotlight on by pressing the raised button once. Press the button
once again to turn off.
• The spotlight will automatically turn off after approximately 7 minutes.
• After use, the tweezers can be put back into place by inserting the
tweezers back into the epilator and pressing the bottom of the tweezers to
lock into place.
Spotlight battery replacement
• The spotlight feature on the epilator and manual precision tweezers
turns off automatically after approximately 7 minutes in order to preserve
battery life.
• The spotlight for the Emjoi Angel uses the same battery as the manual
precision tweezers
• Should the spotlight stop working, the battery will need to be replaced.
Call the Sunbeam Consumer Hotline for a replacement battery.
• To replace battery, remove the manual precision tweezers from
the bottom of the epilator.
• Unscrew the plastic base of the manual precision tweezers by turning it
anti-clockwise.
• Remove the old battery and insert the replacement battery into the
spotlight battery compartment ensuring the battery orientation is correct –
See Figure 1.
• Place the spotlight battery compartment inside the tweezer
arms, ensuring that the locating tabs on each of these are aligned –
See Figure 2.
9

• Whilst holding these firmly in position, place the plastic base on the end.
Ensure the orientation markers on the spotlight battery compartment and
the plastic base are aligned – See Figure 3.
• Screw the plastic base onto the spotlight battery compartment,
ensuring that the orientation markers re-align when finished.
• Insert the manual precision tweezers back into the epilator.
Spotlight battery replacement continued
10
Care and Cleaning
• Switch the epilator off after use. Always turn the power off and remove the
plug before cleaning.
• Do not immerse the appliance in water or any other liquid.
• To clean the exterior, simply wipe over with a dampened cloth and wipe
dry.
• After each use remove the epilation cover by pressing the head release
button. Then brush away any hairs using the brush supplied. Replace the
epilation head before use.
• Occasionally clean the tweezers by wiping with a cotton bud that has been
dipped in alcohol. Remove any residue alcohol before using again.
• Keep the protective cover on the appliance when not in use.
Fig 1
Fig 2
Fig 3
Insert this
end first
Spotlight battery
compartment
Orientation markers
Tweezer arms
Plastic base
Locating tabs
Tweezer arm base

Emjoi Epilators and Lady Shavers
are distributed in Australia and New
Zealand by Sunbeam Corporation
Limited. If you hav e any concerns
regarding the performance and use of
your Emjoi appliance, please contact
the Sunbeam Customer Service
Centre.
Made in China.
Backed by Sunbeam’s 2 year
replacement guarantee and National
Service network
For more information or advice on
this appliance, please contact the
Sunbeam Customer Service Line
Australia 1300 881 861
New Zealand 0800 786 232
03/10
Epilator Unit Battery Disposal
• The epilator unit batteries must not be disposed of in ordinary household
waste. (Please note, these are the batteries contained within the main
epilator unit, not the Manual precision Tweezer battery). At the end of the
epilator’s life, it must be returned to a Sunbeam Service Centre for correct
disposal of the rechargeable battery.
• The battery must be removed from the appliance before it is scrapped.
• The appliance must be disconnected from the supply mains when
removing the battery.
• The battery is to be disposed of safely.
11
Help Line
If you have any additional questions about using your BodyBare epilator,
please call the Sunbeam help line in Australia on 1300 881 861.
In New Zealand, please call 0800 786 232

Consumer Hotline
Australia
1300 881 861
www.emjoi.com.au
New Zealand
0800 786 232
Table of contents
Other Emjoi Epilator manuals

Emjoi
Emjoi BodyBareSilk AY5 User manual

Emjoi
Emjoi BodyBare Angel API7LTA User manual

Emjoi
Emjoi Soft Caress AP-10R User manual

Emjoi
Emjoi BodyBare AquaSmooth AP17SR User manual

Emjoi
Emjoi BodyBare Diva AP14D User manual

Emjoi
Emjoi AP-9FS Spotless Beauty User manual

Emjoi
Emjoi Optima User manual

Emjoi
Emjoi BodyBare Trio AP10LR User manual

Emjoi
Emjoi AP9G BodyBareLuxe User manual

Emjoi
Emjoi DIAMOND User manual