Endon EL- 40068 PIR User manual

The Light pack contains:
Wall light with PIR detector (with integral photocell)
The following tools may be required:
Selection of cross and flat head screwdrivers.
Electric drill and assorted drill bits.
Wire strippers.
Electrical insulation tape.
INSTRUCTION MANUAL
This product is only suitable for connection to a 240V~50Hz supply.
It is recommended that this wall light is installed by a qualified electrician in accordance with current IEE
Wiring Regulations and local Building Regulations and is for the Domestic environment only.
The light fitting should be connected to a lighting circuit protected by a 5 amp fuse (or a 6 amp miniature
circuit breaker).
This light has an IP44 (splash proof) rating suitable for use outdoors.
The detection range (angle / distance) and optimum mounting height is shown here. Use this information
before you choose a mounting position. Do not mount where the PIR can be activated by heat sources such as
central heating vents, animals, traffic etc.
Run supply wire from a 5-amp electrical supply using double insulated 3-core cable of type H05RN-F 1.0mm2
(not supplied) to selected site, ensuring it is adequately protected through the full length of the cable run, it
must come out of the mounting surface in line with the entry to the fitting.
Except where installed in a conduit or duct , which provides equivalent protection against mechanical damage,
a cable buried in the ground shall incorporate an earthed armour or metal sheath or both, suitable for use as a
protective conductor, or be of insulated concentric construction. Buried cables shall be marked by cable
covers or a suitable marking tape. Buried conduits and ducts shall be suitably identified. Buried cables,
conduits and ducts shall be at a sufficient depth to avoid being damaged by any reasonably foreseeable
disturbance of the ground.
This product contains breakable parts – be careful during handling and maintenance to avoid breakage.
This light fitting uses none-replaceable LED`s.
We recommend that you do not stare directly into the light beam (of the LED`s).
If any part of the (LED) housing is broken or cracked then it cannot be replaced and the fitting must not be
used - as the water ingress protection has been compromised.
IMPORTANT: To achieve maximum corrosion resistance the surface of the Stainless Steel must be kept clean.
Surface contamination and the formation of deposits are critical factors which may lead to drastically reduced
life. An example is salt deposits from marine conditions. Washing with soap or a mild detergent and warm
water followed by a clean water rinse and finally wiping dry is usually adequate for most S/S items used in the
domestic environment.
If any modification is made it will invalidate the warranty and may render the product unsafe.
Before you start
Please read these instructions carefully before fitting your new light and retain for reference.
Switch off the mains supply and remove the appropriate fuse or switch off the appropriate circuit breaker
before commencing installation.
Ensure that no one else has access that would enable the supply to be inadvertently reconnected.
Check the packaging and make sure that you have all the required parts.
Follow each assembly step in order to prevent incorrect assembly
Make sure all screws / nuts, including electrical connections etc are fully tightened before use.
DO NOT CONNECT THIS PRODUCT TO A DIMMER SWITCH.
EL- 40068 PIR - Outdoor PIR wall fitting.
Safety Warnings

Endon Lighting
LS9 0SE
20150922
These assembly diagrams are intended as a guide – if in doubt consult a qualified electrician.
Assembly / user instructions
N210 104
Diagram A
Diagram B
Diagram C
1. Determine the position of your light fitting
taking into account the optimum
mounting / detection height (2M). Make
sure there is sufficient cable coming out
of the wall to connect to the terminal
block. Ensure that the mounting surface
is solid, preferably a brick or block wall
and ensure that there are no other cables
or pipes beneath the surface.
2. Diagram A. Fit the 2 threaded posts in
the back plate and bring the mains cable
through the rubber grommet then use the
back plate as a template and mark the 2
fixings holes, making sure the back plate
is the correct way up and the threaded
bolts are horizontal. Use appropriate
fixings to secure the back plate to the
wall.
3. Diagram B. Connect the house wiring to
the internal terminal block. The cable
entry grommet and the back plate seal
must be securely in place to ensure that
the water ingress protection is
maintained. NOTE: This is a Class I
fitting and must be earthed. Connect
the incoming mains as per the diagram
4. Diagram C. Fit the terminal block onto
the post in the back plate and then fit the
front frame over the 2 threaded bolts in
the back plate. Secure with the 2
threaded nuts / clear washers. Take care
not to trap or strain the internal cables..
5. To Test the Lantern. Turn on the
power. To test the PIR unit in daylight,
turn both the timer dial (TIME) and the
Sensitivity dial (SENS) gently fully anti-
clockwise with the blade of a small screw
driver. Activate the PIR by covering the
PIR lens with your hand. The unit will
light and should stay on for
approximately 5-15 seconds then go off.
It will remain off until the light level drops.
6. To adjust Time On. By adjusting the
TIME dial the unit will stay on (once
activated) from 5 -15 seconds (fully anti-
clockwise) to 3 -5 minutes (Fully
clockwise).
7. To adjust sensitivity – detection
distance.By adjusting the SENS dial the
detection distance can be changed –
minimum detection is fully anticlockwise -
or maximum detection distance is dial
turned fully clockwise.
NOTE:-
1. All time on values are approximate.
2. At initial power-on activation, the
lantern will switch on and may remain
on for up to 2 minutes. Keep out of the
way of the activation zone and once
the light goes off make the setting
adjustments.
Threaded posts
Fixing screws
Grommet
Threaded nuts
Table of contents
Popular Accessories manuals by other brands

PCB Piezotronics
PCB Piezotronics M119C12 Installation and operating manual

Yolink
Yolink YS7704-UC user guide

Golf Pad
Golf Pad TAGS user manual

GSN
GSN PATROL 501 Installation instructions manual

Listen Technologies
Listen Technologies LBB 1900 Specification sheet

IDenticard
IDenticard MaxiProx F60-HMX-G installation guide