Endon Renner – 5PCH User manual

1
The Light pack contains:
Light fitting and mounting bracket.
Terminal connection block(s).
Decorative drops.
G9 bulbs.
The following tools may be required:
Selection of cross and flat head screwdrivers.
Electric drill and assorted drill bits.
Wire strippers.
Electrical insulation tape.
INSTRUCTION MANUAL
This product is only suitable for connection to a 240V~50Hz supply in accordance with current IEE
wiring Regulations and should be installed in accordance with local Building Regulations and is for
Domestic indoor ceiling use only and not suitable for a Bathroom location.
The light fitting should be connected to a lighting circuit protected by a 5 amp fuse (or a 6 amp
miniature circuit breaker).
If in doubt we recommend you contact a qualified electrician. Before installing your light fitting
always:
Switch off the mains supply and remove the appropriate fuse or switch off the appropriate circuit
breaker before commencing installation.
Ensure that no one else has access that would enable the supply to be inadvertently reconnected.
Never fit bulbs of a higher wattage or of a type other than those specified on the label as this may
cause overheating and damage the fitting.
These product contains glass parts – be careful during handling and maintenance to avoid
breakage.
The bulbs become hot during use so please switch off and allow 10 minutes to cool before replacing
bulbs or cleaning the fitting.
Clean with a dry cloth only. Do not use liquid or abrasive cleaners on this product.
If any modification is made it will invalidate the warranty and may render the product unsafe.
Before you start
Please read these instructions carefully before fitting your new light and retain for reference.
Make sure that there are no pipes or cables beneath the mounting surface.
Check the packaging and make sure that you have all the required parts.
Follow each assembly step in order to prevent incorrect assembly.
Make sure all screws / nuts, including electrical connections etc are fully tightened before use.
This type of Light Fitting may be connected to a Dimmer if a Tungsten incandescent bulb is used. If
a CFL/LED type bulb is fitted then these cannot (generally) be controlled by a dimmer.
Renner – 5PCH (Ceiling fitting)
Safety Warnings

2
Assembly/ User Instructions
These assembly diagrams are intended as a guide – if in doubt consult a qualified electrician.
Y11 139
Diagram A
1.
Decide on the position of the light fitting / or remove
existing light fitting. Take a note of the position of
the electrical connections. Ensure there is a solid
mounting surface, preferably a wooden joist or joist
bridge to support the weight of the light fitting.
2. See Diagram A. Remove the fixing bracket by
undoing the 2 side screws (1), retain for re-use.
3. Use the fixing bracket (2) as a template to mark the
screw holes, mark the screw holes and secure to
the ceiling with the screws (3) supplied.
4. Diagram B. The length of the `drop` may be
reduced by shortening the cable / support wires. If
you want to reduce the overall length of the fitting it
is essential that this is done before the fitting is
mounted to the ceiling and / or connected to the
mains supply. To do this, shorten the length of the
support wires by pushing up the centre of the
support mechanism (which acts as a clutch) and pull
the wire up through and into the ceiling cup. When
you reach the desired overall length release the
centre clutch – this will then grip the support wire.
We recommend that the minimum distance between
the ceiling cup and the top of the fitting is 100mm.
The cable must now be shortened and the excess
cable cut and re-connected to the terminal block. To
do this, firstly take a note of the position of the
cables in the terminal block then feed the cable up
through the ceiling cup (grub screw) entry hole, cut
off the excess cable and re-connect to the terminal
block. Move the cable anchor down the cable – from
(A) to (B).This is a strain relief device and must be
used. NOTE: The electric cable must always be
longer than the support wire to prevent strain
being placed on the cable. Secure the grub screw
onto the cable.
5. Support your fitting and connect the house wiring to
the terminal block (4) – see wiring details. NOTE:
This is a Class I fitting and must be earthed. The
4th terminal block connector is used for the “loop”
wires of the “Ring Circuit”. There may be more than
one set of cables in the “loop” connections. If there
is a “Ring Circuit” and you do not understand the
connections you must consult an electrician. Any
loose terminal blocks –not secured to ceiling cup -
should always be covered with 2 layers of good
quality insulation tape.
6. Secure the fitting back onto the fixing bracket with
the 2 side screws (1), removed in 2 above. Make
sure that all the internal cables and connections are
inside the ceiling cup taking care not to trap or strain
the internal cables.
7. Fit the decorative drop assemblies (5) as shown.
8. Fit the bulbs (6) into the lamp holders being careful
not to touch the bulbs with your bare hands – use a
cloth or gloves to insert the bulbs. NOTE; Never fit
bulbs of a higher wattage or of a type other than
those provided / specified on the label (as these
may cause overheating and damage the fitting).
9. Turn on the power and test.
Diagram B
Endon lighting Ltd.
Leeds.
UK
LS9 0SE
WIRING DETAILS
Cable entry
tube with grub
screw
Support wire clutch
mechanisms
X 15pcs
X 10pcs
X 5pcs
X 1pc
(A)
(B)