Enertronica Santerno ZZ0132033 User manual

1
•15J0132B100 •
REMOTE SINUS
PC-based engineering tool for
SINUS S inverters
- Installation and connection -
Issued on 13/04/2021
Software Version 1.18
R.01
Enertronica Santerno S.p.A.
Via della Concia, 7 –40023 Castel Guelfo (BO) Italy
Tel. +39 0542 489711 –Fax +39 0542 489722
santerno.com info@santerno.com
•This manual is integrant and essential to the product. Carefully read the instructions contained
herein as they provide important hints for use and maintenance safety.
•This device is to be used only for the purposes it has been designed to. Other uses should be
considered improper and dangerous. The manufacturer is not responsible for possible damages
caused by improper, erroneous and irrational uses.
•Enertronica Santerno S.p.A. is responsible for the product in its original setting.
•Any changes to the structure or operating cycle of the product must be performed or
authorized by Enertronica Santerno S.p.A.
•Enertronica Santerno S.p.A. assumes no responsibility for the consequences resulting by the
use of non-original spare-parts.
•Enertronica Santerno S.p.A. reserves the right to make any technical changes to this manual
and to the product without prior notice. If printing errors or similar are detected, the corrections
will be included in the new releases of the manual.
•The information contained herein is the property of Enertronica Santerno S.p.A. and cannot be
reproduced. Enertronica Santerno S.p.A. enforces its rights on the drawings and catalogues
according to the law.

2
Content
About this document .............................................................................................. 2
Required hardware ................................................................................................. 3
Installation .............................................................................................................. 4
Import the Device Description files (*.lpk files)...................................................... 5
Connection to Sinus S with USB module................................................................. 7
Connection to Sinus S with WLAN module ............................................................. 9
About this document
Read this documentation thoroughly before carrying out the installation and commissioning.
▶Please observe the safety instructions!
Document description
You will find information on wiring and commissioning in the mounting and switch-on instructions
of the inverter.
Information and tools with regard to the Enertronica Santerno products can be found on the Internet:
santerno.com
WARNING!

3
Required hardware
Either an USB module or a WLAN module is required to connect the Sinus S inverter to a PC with the
Enertronica Santerno Remote Sinus Engineering Tool.
USB module
Parameterising without supplying the inverter with voltage: if you connect the inverter directly to the PC
without a hub, in many cases the USB interface of the PC is sufficient for the voltage supply.
USB module
Order code
Version
ZZ0132033
Parameter setting without voltage supply of the inverter
USB 2.0 connecting cable required
Connecting cable
Order code
Length
Version
PC6604600
3 m
USB 2.0‑connecting cable (A plug to micro-B plug)
PC6604700
5 m
WLAN module
Connection data (default setting)
IP address
192.168.178.1
SSID
Sinus S_5678901234
Password
password
WLAN module
Order code
Design
ZZ0132043
Range in open space: 100 m, conditions on site may restrict the range.

4
Installation
All the procedure is based on Remote Sinus 1.18 software: if you do not have this software installed,
please download it from the dedicated REMOTE SINUS SOFTWARE - Enertronica Santerno area.
Both the .exe file and the .zip files shall be downloaded.
The V06.02.36.12.zip contains the *.lpk Device Description files for Sinus S.
After completing the installation, two icons are created on your PC:

5
Import the Device Description files (*.lpk files)
1. Open Remote Sinus Package Manager and then click on “Import”

6
2. Choose the folder on your PC which contains the *.lpk files. If the folder is
correct, you will see: n files found (n lpk).
Now click on Install.
After this step the *.lpk files have been loaded on your PC (two files each CPU).
In this way Remote Sinus can interface with the proper CPU mounted on Sinus S.
Your folder address
The folder is correct

7
Connection to Sinus S with USB module
Open Remote Sinus.
Check that the drive is connected to the PC with USB cable, then select USB-USB
with module ZZ0132033.

Click on Insert and you will be able to read/write all the parameters.

9
Connection to Sinus S with WLAN module
Open Remote Sinus.
If you have WLAN module, plug it on the drive and power the SINUS S, you will
see a new wi-fi network in the wi-fi settings of the PC.
Now, connect the PC to the SINUS S as shown in the picture.
The default password is "password".

In REMOTE SINUS select WLAN-WLAN with module ZZ0132043.
Write the IP address of the drive (default IP is 192.168.178.1).
Click on Insert and you will be able to read/write all the parameters as shown in
the USB connection.