EntraPass KT-400 User manual

KT-400
Ethernet Four-Door Controller
Installation Manual
wwww.EntraPASS.com

wwww.EntraPASS.com / 8641 S. Warhawk Rd., Conifer, CO 80433 - Tel: 303-670-1099 - Email: [email protected]
wwww.EntraPASS.com

Table of contents
Pre-Installation Information........................................................................................................................ 1
Copyright Information .................................................................................................................. 1
Safety Instructions ....................................................................................................................... 1
Technical Support ..................................................................................................................................... 2
Overview ................................................................................................................................................... 3
Compatible with all EntraPass Special, Corporate and Global Editions ....................................... 3
IP Devices ................................................................................................................................ 3
Four Onboard doors ..................................................................................................................3
Communication Ports ................................................................................................................3
IP Connectivity ..........................................................................................................................3
Inputs .......................................................................................................................................4
Lock Outputs .............................................................................................................................4
Relay Outputs ...........................................................................................................................4
Reader Outputs .........................................................................................................................4
Reader Interfaces ......................................................................................................................4
Elevator Interface ......................................................................................................................4
Alarm Panel Interface ................................................................................................................4
Automatic Port Detection ...........................................................................................................4
Downloadable Firmware ............................................................................................................5
Trouble and Reporting ...............................................................................................................5
Visual Status Indicators (LEDs) ..................................................................................................5
Built-in SPI Expansion ...............................................................................................................5
System Architecture ................................................................................................................................. 9
Heartbeat LED Patterns ......................................................................................................................... 12
Technical Specifications ......................................................................................................................... 13
Electrical Specifications .......................................................................................................................... 14
KT-400 Ethernet Four-Door Controller Models, Expansion Modules Models, Related Documentation and
Miscellaneous Items ............................................................................................................................... 14
Models Information ................................................................................................................................. 16
Installing the KT-400 Ethernet Four-Door Controller .............................................................................. 17
Preparing to Install the KT-400 Ethernet Four-Door Controller .................................................17
Physical Installation ................................................................................................................... 17
Earth Grounding ........................................................................................................................ 17
Door Locking Devices ................................................................................................................ 17
Hooking Up Inputs ..................................................................................................................... 18
Connect readers and keypads ..................................................................................................18
Relay Controlled Outputs .......................................................................................................... 19
Auxiliary Outputs ....................................................................................................................... 19
Tamper Protection ..................................................................................................................... 19
Connecting the KT-400 Ethernet Four-Door Controller .......................................................................... 20
Connecting the VC-485 or the USB-485 to the RS-485 Bus ..................................................... 20
Connecting over Corporate Network (LAN) .......................................................................21
Powering the KT-400 Ethernet Four-Door Controller ............................................................................. 21
SPI Expansion Port ................................................................................................................................ 23
Important Installation Rules about Expansion Modules .......................................................................... 24
Troubleshooting ...................................................................................................................................... 28
Default Initialization .................................................................................................................29
How to reset the KT-400 Ethernet Four-Door Controller for Factory Default DHCP mode ....... 29
KT-400 Ethernet Four-Door Controller Maintenance Recommendations ............................................... 30
Configuring the KT-400 Ethernet Four-Door Controller with the Web Configuration Page .................... 31
Optional Documentation ............................................................................................................ 31
Configuring the KT-400 Ethernet Four-Door Controller with the KT-Finder ........................................... 32
Installation Checklist ............................................................................................................................... 36
Inputs and Outputs Assignments Sheet ................................................................................................. 37
Appendix A .............................................................................................................................................39
Compliance Specifications .....................................................................................................................39
UL ......................................................................................................................................... 39
UL 294 Compliance Notice ......................................................................................................39
UL 1076 Compliance Notice .................................................................................................... 39
FCC & IC ............................................................................................................................... 40
CE & C-Tick ........................................................................................................................... 40
EN50133 Compliance .............................................................................................................41
wwww.EntraPASS.com

iv
wwww.EntraPASS.com / 8641 S. Warhawk Rd., Conifer, CO 80433 - Tel: 303-670-1099 - Email: [email protected]
wwww.EntraPASS.com

1
KT-400 Ethernet Four-Door Controller Installation Manual
Pre-Installation Information
To the Installer: If you are familiar with the installation, you can use the installation checklist on page 36 with
the symbol.
Safety Instructions
Important: NEVER INSTALL THE EQUIPMENT DURING A LIGHTNING STORM!
This equipment, KT-400 Ethernet Four-Door Controller Model KT-400-EU, shall be used installed and used within an
environment that provides the pollution degree max 2 and over voltages category II NON HAZARDOUS LOCATIONS, INDOOR
only. The equipment is FIXED and PERMANENTLY CONNECTED and is designed to be installed by Service Persons only;
[service person is defined as a person having the appropriate technical training and experience necessary to be aware of
hazards to which that person may be exposed in performing a task and of measures to minimize the risks to that person or other
persons.] The equipment is installed in a metallic cabinet that meets the applicable requirements for a FIRE ENCLOSURE.
Note: When installed on the North American Market, powered via the UL, cUL Listed 75VA Transformer, the KT-400 Ethernet
Four-Door Controller shall be connected to the mains by a LICENSED ELECTRICIAN in accordance with the applicable
rules of the National Electrical Code or Canadian Electrical Code regarding this type of connection.
1. The connection to the mains supply must be made as per the local authorities rules and regulations: In the UK as per
BS6701. An appropriate disconnect device must be provided as part of the building installation. Where it is not possible to rely
on the identification of the NEUTRAL in the AC MAINS SUPPLY, the disconnecting device must disconnect both poles
simultaneously (LINE and NEUTRAL).
2. AVOID setting up the equipment near heaters, air conditioners, ventilators, and/or refrigerators;
DO NOT select a place that exposes your controller to direct sunlight, excessive heat, moisture, vapors, chemicals or dust.
3. If during the installation a knockout on the cabinet is removed, it is the installer's responsibility to ensure that the same
degree of protection for the cabinet is provided by the use of bushings, fittings, adequate sealant, etc.
4. The metallic cabinet must be secured to the building structure before operation. Use four (4) stainless steel tapping
screws #8, 32 mm (1.25 in) to mount the cabinet.
5. The ground connection must be as shown within the included diagram, or equivalent.
6. Internal wiring must be routed in a manner that prevents:
- Excessive strain on wire and on terminal connections;
- Loosening of terminal; connections;
- Damage of conductor insulation;
- Reducing the clearance between SELV (Safety Extra Low Voltage) circuits and NON-POWER Limited Circuits (Battery wires);
- Route the battery wires away from the rest of the SELV circuits.
7. It is the end-user and/or installer's responsibility to ensure that the disposal of the used batteries is made according to the
waste recovery and recycling regulations applicable to the intended market.
8. There are no serviceable parts within the equipment; For any issues regarding the equipment please contact your
installer.
9. Before leaving the premises, the Ethernet communication lines must first be connected to an approved (acceptable to local
authorities) type Network Interface Device (NID), (UL installations, UL 60950 listed NID, for ULC installations CAN/CSA C22.2,
No. 60950-1 Certified NID). All wiring shall be performed according to the local electrical codes.
10. DISCONNECT POWER BEFORE SERVICING.
wwww.EntraPASS.com / 8641 S. Warhawk Rd., Conifer, CO 80433 - Tel: 303-670-1099 - Email: [email protected]
wwww.EntraPASS.com

2
Technical Support
For technical assistance with the KT-400 Ethernet Four-Door Controller and other EntraPASS products,
contact technical support, Monday to Friday, at (303) 670-1099.
wwww.EntraPASS.com / 8641 S. Warhawk Rd., Conifer, CO 80433 - Tel: 303-670-1099 - Email: [email protected]
wwww.EntraPASS.com

3
KT-400 Ethernet Four-Door Controller Installation Manual
Overview
The KT-400 Ethernet Four-Door Controller is designed to meet the highest standards of access control and point
monitoring applications. Here are the features of the KT-400 Ethernet Four-Door Controller.
Compatible with all EntraPass Special, Corporate and Global Editions
The KT-400 Ethernet Four-Door Controller is compatible with all EntraPass Editions v5.00 and higher:
- EntraPass Special Edition
- EntraPass Corporate Edition with a Multi-site Gateway
- EntraPass Global Edition with a Multi-site Gateway
- EntraPass Global Edition with a Global Gateway
- EntraPass Global Edition with a KT-NCC Network Communications Controller
IP Devices
-EntraPass: The KT-400 Ethernet Four-Door Controller can be configured with all EntraPass Editions v5.01 and
higher.
Note: A KT-400 Ethernet Four-Door Controller firmware download is possible with EntraPass v4.01 and higher.
-Web Configuration Page: The Web Configuration Page is accessible through any browser. It can be used to verify
and configure the IP settings of the following devices: the KT-400 Ethernet Four-Door Controller, the KT-
NCC and the IP Link. Refer to the procedure “Configuring the KT-400 Ethernet Four-Door Controller with
the Web Configuration Page” on page 31 for further details.
-KT-Finder: The KT-Finder is a stand-alone application that can be used to verify and configure the IP settings of the
following devices: the KT-400 Ethernet Four-Door Controller, the KT-NCC, KTES and the IP Link.
The device can be located within the same LAN or in a remote location over the internet. Refer to the
procedure “Configuring the KT-400 Ethernet Four-Door Controller with the KT-Finder” on page 32 for further details.
Four Onboard doors
The KT-400 Ethernet Four-Door Controller is a full 4 onboard doors access controller. See Figure 1 for a description of
the PCB and Figure 2 for all the connection possibilities offered by the KT-400 Ethernet Four-Door Controller.
Communication Ports
• 1 10/100Base-T (ETH1) Ethernet for network connection with the EntraPass Gateway
• 1 10/100Base-T (ETH2) Ethernet for network connection with intelligent IP peripherals
• 1 RS-232 for communication with EntraPass
• 1 RS-485 (COM1) for communication with EntraPass or loop of controllers
• 1 RS-485 (COM2) for RS-485 communication between the KT-400 and RS-485 modules
• 1 SPI for communication with SPI modules
• 1 USB 2.0 Host
Note: You can connect a loop of KT-200 controllers on the RS-485 of the KT-400 if not mixed with other controllers
(KT-100, KT-300 and KT-400).
Note: The 10/100Base-T (ETH2), RS-485 (COM2) and USB 2.0 Host communication ports are to be used ONLY on
upcoming versions of the KT-400 controller.
IP Connectivity
The KT-400 Ethernet Four-Door Controller, when used with EntraPass Special Edition or a Multi-Site Gateway, can report
events, gather its configuration through an IP connection over the LAN (Local Area Network) and over the Internet for a
WAN (Wide Area Network). In this mode, the 1st or local controller becomes a “Master Controller” and can poll up to 31
EntraPASS controller(s). The KT-400 Ethernet Four-Door Controller is compatible with all the controllers. Unlike the other
controllers, the KT-400 Ethernet Four-Door Controller asynchronously polls the controllers (KT-100, KT-200, KT-300) and
communicates with the EntraPass Gateway only when necessary. This significantly reduces the amount of bandwidth
required to operate your security system on the network.
•AES Encryption 128-Bit: The KT-400 Ethernet Four-Door Controller is extremely secure. It uses 128-bit AES
encryption to communicate with the Gateway which prevents any hacking from the internet and ensures secure
communications when used over the internet on a wide area network (WAN).
wwww.EntraPASS.com / 8641 S. Warhawk Rd., Conifer, CO 80433 - Tel: 303-670-1099 - Email: [email protected]
wwww.EntraPASS.com

4
Inputs
There are 16 onboard inputs on the KT-400 Ethernet Four-Door Controller. Up to 240 more can be added through the
addition of expansion modules, such as the KT-MOD-INP16, for a total of 256 inputs. If using the KT-MOD-INP16
input module as double end of line resistor, there is a128 inputs limitiation. Each input can be individually
configured for one of the following application:
• Door contact (4 onboard)
• T.Rex (Request to Exit Detector) (4 onboard)
• Interlock (4 onboard)
• Floor Selection for Elevator Application
•ElevatorAction
• External Alarm System Status (Armed / Disarmed)
• External Alarm System Alarm (Alarm / Secure)
• External Alarm System Zones
• Relays to trigger on each input in alarm event
• Zone shunt: Single or group of zones can be permanently or temporarily 'shunted' to a secure state on the same
controller. Shunt method includes:
- Zone Shunt by another Zone - When a zone in alarm is programmed to shunt another zone / group of zones.
- Zone Shunt on Unlock - When a zone is temporarily frozen to its actual state (alarm or secured) after an access
granted.
- Manual Shunt - Operator can manually 'Shunt' a zone to a secure state.
- Disarmed Door Shunt - When alarm system is disarmed, some zones may be 'Shunted' to a secure state.
- Entry / Exit Delay Shunt - When a user is in the process of disarming / arming the alarm system and entry / exit
delay prevails, some zones may be 'Shunted' to a secure state.
• Arming / Disarming Request
• Postpone Arming Request
• Tamper switch input: The tamper switch is a non-programmable 'Fixed-Function' input. It is used to identify tampering of
the KT-400 cabinet.
Lock Outputs
There are 4 onboard lock outputs and they are supervised. The locking function can also be performed by any onboard
relay configured for this functionality.
Relay Outputs
There are 4 onboard relay outputs. Up to 256 relay outputs can be supported through the addition of expansion modules
such as the KT-MOD-REL8.
Reader Outputs
There are 4 different possible outputs for each of the 4 onboard reader interfaces for a total of 16 programmable outputs.
Reader outputs are used to give user visual and/or audible feedback on the ongoing access events.
Reader Interfaces
There are 4 onboard reader interfaces. They can be programmed for Wiegand or ABA (Clock and Data) readers.
Elevator Interface
The KT-400 Ethernet Four-Door Controller supports elevator interfacing with the addition of expansion modules such as
the KT-MOD-REL8, KT-MOD-INP16 and KT-MOD-OUT16.
Alarm Panel Interface
The KT-400 Ethernet Four-Door Controller supports alarm panel interfacing with the appropriate connections made
between zone inputs, relay outputs and the alarm system panel.
Automatic Port Detection
The KT-400 Ethernet Four-Door Controller automatically detects the site communication speed set by EntraPass as well
as the communication port which can be IP (ETHERNET #1), RS-485 (COM1) or RS-232 (COM3).
wwww.EntraPASS.com / 8641 S. Warhawk Rd., Conifer, CO 80433 - Tel: 303-670-1099 - Email: [email protected]
wwww.EntraPASS.com

5
KT-400 Ethernet Four-Door Controller Installation Manual
Downloadable Firmware
The firmware program can be downloaded from any EntraPass workstation to the KT-400 Ethernet Four-Door Controller.
The firmware program, stored in the controller’s flash memory, is upgraded without having to change any parts.
Trouble and Reporting
The KT-400 Ethernet Four-Door Controller constantly supervises ac power and battery condition and reports “AC Lost”,
“Normal Battery”, “Low Battery”, “Battery Critical” or “No Battery”, status to the EntraPass system. Power outputs are
supervised and electronically protected against short-circuits and surges. Locking devices are also supervised for short
and open circuits.
Visual Status Indicators (LEDs)
The KT-400 Ethernet Four-Door Controller has multiple status indicators such as for troubleshooting, network activity,
power status and outputs activity. See Figure 1 for their locations.
-Heartbeat (BLUE): The Heartbeat blue LED indicates the communication status with EntraPass or the IP mode of
the controller. Refer to Table 1 for a descriptions of the heartbeat patterns.
- Diagnostic (RED) :The DIAG red LED is for factory diagnostics and should never be seen on otherwise.
-SPI Active (YELLOW): This LED signals activity on the SPI expansion port.
-COM1-RX, COM1-TX, COM2-RX, COM2-TX, RS232-RX and RS232-TX (YELLOW): The six serial port LEDs are
transmit/receive activity indicators.
-LOCK1, LOCK2, LOCK3 and LOCK4 (RED): Each lock output (Open Drain) has an indicator which turns on each
time the corresponding output is activated.
-RELAY1, RELAY2, RELAY3 and RELAY4 (RED): Each relay output has an indicator which turns on each time the
corresponding relay is activated.
-AC PWR and DC PWR (GREEN): The AC PWR LED is ON when AC power is present. The DC PWR is ON when
the DC level is sufficient for all DC terminals such as the 12V AUX. For further details, see Troubleshooting on page
28 section.
- ETH1, ETH2 LINK (GREEN): The LED is OFF when there is no Ethernet network or the cable is disconnected, and
ON when there is an Ethernet cable and network connection.
-ETH1, ETH2 TXRX (YELLOW): The LED indicates network activity.
Built-in SPI Expansion
The KT-400 Ethernet Four-Door Controller allows connection of expansion modules in order to add outputs, like relays
and open drain outputs, and inputs. See Figure 10 and Figure 11 for an example with expansion modules.
-KT-MOD-REL8: The KT-MOD-REL8 is an 8-relay expansion module. Each relay is 3 Amps, 30 VDC Form C. The
module supports daisy-chaining which can add up to 32 KT-MOD-REL8 modules for a total of 256 relay outputs per
KT-400 Ethernet Four-Door Controller.
-KT-MOD-INP16: The KT-MOD-INP16 is a 16-zone input expansion module. The module supports daisy-chaining
which can add up to 15 KT-MOD-INP16 for a total of 240 external inputs per KT-400 Ethernet Four-Door Controller.
The KT-400 Ethernet Four-Door Controller has 16 onboard inputs which gives a total of 256 inputs per controller.
-KT-MOD-OUT16: The KT-MOD-OUT16 is a 16-output expansion module. Each output is capable of 750 mA. It
gives the opportunity to address the need for external LED, lock, relay, piezo and buzzer control. The module
supports daisy-chaining which can add up to 16 KT-MOD-OUT16 modules for a total of 256 external open drain
outputs per KT-400 Ethernet Four-Door Controller.
Note: The expansion modules support daisy chaining which can add up to 32 KT-MOD-REL8 modules for a total of 256
external relays per KT-400 Ethernet Four-Door Controller. Combining input and output expansion modules gives the
flexibility to connect up to 256 inputs and 256 outputs.
wwww.EntraPASS.com / 8641 S. Warhawk Rd., Conifer, CO 80433 - Tel: 303-670-1099 - Email: [email protected]
wwww.EntraPASS.com

6
Figure 1: KT-400 Ethernet Four-Door Controller PCB View
wwww.EntraPASS.com

7
KT-400 Ethernet Four-Door Controller Installation
Manual
Figure 2: KT-400 Ethernet Four-Door Controller Inputs and Outputs View
wwww.EntraPASS.com

8
Figure 3: KT-400 Cabinet Models for North America and European Union
wwww.EntraPASS.com

9
KT-400 Ethernet Four-Door Controller Installation Manual
System Architecture
The KT-400 Ethernet Four-Door Controller can be used through various site applications with EntraPass Special,
Corporate and Global Editions.
Applications with EntraPass Special and Corporate Editions with Multi-site Gateway.
• Over the internet. See Figure 4.
• Over RS-485 with a USB-485. See Figure 5.
Application with EntraPass Global Edition and a Global Gateway.
• Over RS-485 with a VC-485. See Figure 6.
Application with EntraPass Global Edition and a KT-NCC.
• Over the Internet with a KT-NCC. See Figure 7.
Application with EntraPass Special, Corporate and Global Editions.
• Over RS-232 straight from EntraPass RS-232 COM port. See Figure 8.
Figure 4: Over the Internet with EntraPass Special and Corporate Editions with Multi-site Gateway
wwww.EntraPASS.com / 8641 S. Warhawk Rd., Conifer, CO 80433 - Tel: 303-670-1099 - Email: [email protected]
wwww.EntraPASS.com

10
Figure 5: USB-485 with EntraPass Special and Corporate Editions with Multi-site Gateway
Figure 6: VC-485 with EntraPass Global Edition and Global or Multi-site Gateway
wwww.EntraPASS.com / 8641 S. Warhawk Rd., Conifer, CO 80433 - Tel: 303-670-1099 - Email: [email protected]
wwww.EntraPASS.com

11
KT-400 Ethernet Four-Door Controller
Installation Manual
Figure 7: Over the Internet with a KT-NCC and EntraPass Global Edition
Figure 8: Over RS-232 straight from the EntraPass RS-232 COM port
wwww.EntraPASS.com

12
Heartbeat LED Patterns
Communication status and other vital controller parameters can be obtained from heartbeat LED patterns. It is located
near the center of the board, see Figure 1. This information is particularly useful when connecting the controller to the
rest of the EntraPass system. The following table lists all conditions along with a brief description. Refer to Table 3, if you
must reset or change the communication mode of the KT-400 Ethernet Four-Door Controller.
Table 1: Heartbeat LED Patterns
Booting Up Steady
Factory Default DHCP Continuous LONG Pulses
Unable to Resolve DNS 2 LONG Pulses
Forced Default Static 3 LONG Pulses
DHCP Server Failed 4 LONG Pulses
Receive Broadcast Single 2.5 Sec. Burst
Card Read or Swipe Single 0.5 sec burst, resume
previous flash
Hard Reset 4 SHORT Pulses
Multi-site Gateway 3 SHORT Pulses
Global Gateway 1 SHORT Pulse
Fail Soft Continuous SHORT Pulses
Firmware Update 5 pulses / sec @ 50% duty cycle
Rebooting 10 pulses / sec @ 50% duty cycle
wwww.EntraPASS.com / 8641 S. Warhawk Rd., Conifer, CO 80433 - Tel: 303-670-1099 - Email: [email protected]
wwww.EntraPASS.com

13
KT-400 Ethernet Four-Door Controller
Installation Manual
Technical Specifications
Type Description
AC Power input (KT-400) Transformer class 2, 120 VAC 75VA IN; 16 or 24 VAC OUT
AC Power input (KT-400-EU) Transformer 230 VAC 50 Hz 100 VA IN, 16.5 VAC OUT
Battery back-up (KT-BATT-12) 12 VDC, 12 Ah battery is recommended when using electromagnet door lock
Operating Temperatures For UL listed installations: 0°C to 49°C (32°F to 120°F) indoor use only
For EN50133 compliant installations: 5°C to 40°C (41°F to 104°F) indoor Group I
Humidity Level 93% max. (relative humidity non-condensing)
Cabinet Dimensions
(High-Wide-Deep) 37.59 cm (14.8 in) x 30.48 cm (12.0 in) x 12.57 cm (4.95 in)
Cabinet Weight (KT-400) 4.0 kg (8.82 lb)
Cabinet Weight (KT-400-EU) 7.0 kg (15.43 lb)
PCB dimension 23.11cm (9.1in) x 13.97cm (5.5in) x 4.06cm (1.6in)
Reader types Wiegand, proximity, ABA Clock and Data, bar code, magnetic, integrated keypad,
smartcard and others
Reader power output 12 VDC and 5 VDC @ 1A max each, protected and supervised
Monitored points
(zone inputs) 16 monitored points (Z1 to Z16), NO/NC, without EOL (DRY), single EOL, double EOL and
1 fixed-function tamper switch input
Points maximum wiring AWG #22 - 600 m (2,000 ft)
Door strike power supervised • 500 mA each or 2.0 Amps total for the KT-400 model (JP4 on INT)
• 1 A each or 4.0 Amps total for the KT-400 model (JP4 on EXT)
• 750 mA each or 3.0 Amps total for the KT-400-EU model (JP4 on INT)
Auxiliary reader outputs LEDs (LED, OUT1 and OUT2) and buzzer (BUZ) for each individual door,
25mA max each, open collector outputs
Relay controlled output 4 onboard Form C Relay controlled outputs, 30 VDC, 3 Amps max each
Communication ports 1 x RS-232 with RJ-12, 2 x RS-485, 2 x Ethernet 10/100 Base-T with RJ-45
Expansion port 1 x SPI 6-pin connector, bidirectional data exchange supported. Supplies 12 VDC, 500 mA
max shared with 12 VDC Auxiliary port
Auxiliary power 1 x Auxiliary 12 VDC, 500 mA maximum shared with SPI expansion port
Communication speed - 1200 to 115200 Bauds (automatic detection) over RS-232 and RS-485
- 10/100 Mb/s BaseT over Ethernet
Flash memory 256 MB NAND flash for application, storage and stand-alone event buffer holding 20,000
events
RAM memory 128 MB DDR2 for application loading and running
Network autonomy Distributed data and processing
Certifications / Listing EN50133-1, EN55022, EN60950-1, EN61000-6-1, EN61000-6-2
FCC: Part15/ICES Class A
UL 294, UL 1076, C-Tick
Note: The KT-400 is capable of restarting automatically after total power loss and will keep the programming for more than 120
hours of power interruption. The design is using flash memory for saving access rules.
This is certified by Telefication under the requirements of EN50133-1, Recognition Class 0-3, Access Class A/B,
Environmental Class II.
wwww.EntraPASS.com

14
Electrical Specifications
KT-400 Ethernet Four-Door Controller Models, Expansion Modules Models,
Related Documentation and Miscellaneous Items
AUXILIARY READER OUTPUTS MAXIMUM CURRENT
(Typical) COMBINED MAXIMUM
CURRENT
LEDs (LED, OUT1 and OUT2) for each door reader 25 mA (each)
3.0 Amps for KT-400
4.0 Amps for KT-400EU
5.0 Amps with optional
Buzzer (BUZ) for each door reader 25 mA (each)
OUTPUTS MAXIMUM CURRENT
1 for 12 VDC Auxiliary Power (11.2 to 13.75 VDC) polyswitch
protected, shared with SPI expansion port 500 mA
4 for Controlled Readers (11.2 to 13.75 VDC) 1.0 A
4 for Controlled Readers 5 VDC 1.0 A
4 for Locks (11.2 to 13.75 VDC) when jumper JP4 is on INT
(internal) 2.0 Amps for KT-400
3.0 Amps for KT-400EU
4.0 Amps with optional
4 for Locks (12 to 28 VDC) when jumper JP4 is on EXT
(external) 4.0 Amps for both models
Part number Description
KT-400 Ethernet Four-Door Controller Models
KT-400 KT-400 Ethernet Four-Door Controller, IP Ready with Accessory Kit in Metal Cabinet, see Table 2
KT-400-EU KT-400 Ethernet Four-Door Controller, IP Ready with Accessory Kit in Metal Cabinet, European
Union Model, see Table 2
KT-400-PCB KT-400 Ethernet Four-Door Controller PCB only, IP Ready with Accessory Kit, see Table 2
KT-400-CAB KT-400 Black Metal Cabinet with Lock and Keys, see Table 2
KT-400-CABEU KT-400 Black Metal Cabinet with Lock and Keys, European Union Model, see Table 2
Expansion Modules Models
KT-MOD-INP16 KT-400 Expansion Module 16-Zone Inputs with SPI Cable 41 cm (16 in)
KT-MOD-REL8 KT-400 Expansion Module 8-Relay with SPI Cable 41 cm (16 in)
KT-MOD-OUT16 KT-400 Expansion Module 16-Output with SPI Cable 41 cm (16 in)
KT-MOD-CAB KT-400 Expansion Module Cabinet, Black, with SPI Cable 91 cm (36 in), Lock and Two Keys
KT-MOD-CABEU KT-400 Expansion Module Cabinet, Black, with Electrical Parts, SPI Cable 91 cm (36 in), Lock and
Two Keys, European Union Model
KT-MOD-SPI-16 KT-400 SPI Cable 41 cm (16 in) for SPI Interconnection within the Cabinet
KT-MOD-SPI-36 KT-400 SPI Cable 91 cm (36 in) for SPI Interconnection between Cabinets
Related Documentation
DN1420 EntraPass Special Edition, Reference Manual - English version
wwww.EntraPASS.com / 8641 S. Warhawk Rd., Conifer, CO 80433 - Tel: 303-670-1099 - Email: [email protected]
wwww.EntraPASS.com

15
KT-400 Ethernet Four-Door Controller Installation Manual
DN1415 EntraPass Corporate Edition, Reference Manual - English version
Related Documentation (continued)
DN1316 EntraPass Global Edition, Reference Manual - English version
DN1474 EntraPass Special Edition, Reference Manual - French version
DN1435 EntraPass Corporate Edition, Reference Manual - French version
DN1289 EntraPass Global Edition, Reference Manual - French version
DN1796 Networking Basics, Application Note, English version
Dimensions Drawings
DN1791 KT-CAB3000LDR 71 cm (28 in) Cabinet Dimensions Drawing
DN1793 KT-CAB4000LDR 107 cm (42 in) Cabinet Dimensions Drawing
DN1846 KT-400-PCB Dimensions Drawing
DN1848 KT-400-CAB Dimensions Drawing (UL Listed)
DN1850 KT-400-CABEU Dimensions Drawing (CE Compliant)
DN1851 KT-MP400 Mounting Plate Dimensions Drawing
DN1852 KT-MP500 Mounting Plate Dimensions Drawing
Miscellaneous Items
CBLK-10 Cable kit, RS-232 cable 30 m (100 ft) with RJ-12 connectors for PC to master KT-400, 740-1023
(DB9F to RJ-12) adaptor and 740-1041 (DB9M to DB25F) adaptor
USB-485 USB-485 interface, USB cable 0.9 m (3 ft) and USB drivers on CD-ROM
VC-485 VC-485 interface, RS-232 cable 3 m (10 ft) with RJ-12 connectors, 740-1012 (DB25F to RJ-12)
adaptor, 740-1022 (DB9F to RJ-12) adaptor and 740-1033 (DB25M to RJ-12) adaptor
KT-3LED-PLATE Three-color LED alarm indicator mounted on single plate
KT-ACPW-LED AC power LED indicator
KT-LOCK Keylock for cabinet with 2 keys
KT-SW1224 Internal Power Supply 12 VDC, 2 Amps, 24 Watts for KT-MOD Expansion Modules only
KT-SMP3 Internal Power Supply 12 VDC, 2.5 Amps, 30 Watts for KT-400-EU model only
KT-TAMPER Tamper switch for cabinet
KT-400-CON KT-400 removable terminal block spare kit
TR1675 Hammond BF2F Transformer Class 2 wire-in, 120 VAC IN; 16 VAC OUT, UL Listed.
TR2475 Hammond BF2G Transformer Class 2 wire-in, 120 VAC IN; 24 VAC OUT, UL Listed
TR16100-240V Transformer, 230 VAC 50 Hz 100 VA IN; 16.5 VAC OUT, CE Compliant
Part number Description
wwww.EntraPASS.com / 8641 S. Warhawk Rd., Conifer, CO 80433 - Tel: 303-670-1099 - Email: [email protected]
wwww.EntraPASS.com

16
Models Information
•KT-400: Cabinet with one KT-400 for North America, up to two expansion modules can be installed in the cabinet,
•KT-400-PCB: KT-400 with parts,
•KT-400-ACC: Accessory kit,
•KT-400-CAB: Cabinet only for North America,
•KT-400-EU: Cabinet with KT-400, transformer, power supply and fuse terminal block for European Union,
•KT-400-CABEU: Cabinet only for European Union.
Table 2: Bills of Material Models
Note 1: The KT-400, KT-400-CAB, KT-400-EU and KT-400-CABEU models also include the KT-LOCK.
Note 2: The KT-400, KT-400-PCB and KT-400-EU models also include screws and locknuts.
Note 3: The KT-400-EU model also includes additional screws and cables.
Note 4: Cabinet wall mounting requires four (4) screws. We recommend stainless steel Phillips tapping screws M4.2 x 32mm
(#8 x 1.25'') (Spaenaur ST-631P or equivalent). Drywall mounting must also use four (4) plastic anchors (Spaenaur EX-
S5 or equivalent; not included).
Note 5: A time-lag fuse of 630mA is included with the fuse block terminal. If replacement is needed, only use recommended
type (250VA, 630mA, Time-lag, TUV or VDE approved, must meet EN60127-1/2/3).
Item Description KT-400
(Notes
1, 2 & 4)
KT-400-PCB
(Note 2)KT-400-ACC KT-400-CAB
(Notes 1 & 4)KT-400-EU
(Notes 1, 2,
3, 4 & 5)
KT-400-
CABEU
(Notes1
& 4)
KT-400 PCB 1 1 - - 1 -
Cabinet 1 - - 1 1 1
KT-400-ACC Accessory Kit 1 1 - - 1 -
Ground wire (PCB to cabinet) 1 1 - - - -
Ground wire (door to cabinet) 1 1 - 1 1 -
Tamper switch 1 - - - 1 -
Battery cable 1 1 - - 1 -
Resistor 5.6K, 0.5W - - 32 - - -
Resistor 1K, 0.5W - - 4 - - -
Fuse terminal block - - - - 1 -
230 VAC 100 VA IN,
16.5 VAC OUT, Transformer -- - - 1-
Inner door sticker for North
America, DN2023, Figure 14 1- - 1 --
Inner door sticker for
European Union, DN2024,
Figure 15 -- - - 11
Installation Manual DN2022 -
French 11 - - 1-
Installation Manual DN2003 -
English 11 - - 1-
wwww.EntraPASS.com / 8641 S. Warhawk Rd., Conifer, CO 80433 - Tel: 303-670-1099 - Email: [email protected]
wwww.EntraPASS.com
Other manuals for KT-400
1
Table of contents
Other EntraPass Controllers manuals
Popular Controllers manuals by other brands

Engineered air
Engineered air EngA W-TRAC Installation, operation and maintenance manual

Det-Tronics
Det-Tronics R8471E instructions

Concept LED Lights
Concept LED Lights CL-WC-DMX-04 Quick start quide

Colortran
Colortran Scene Master 60 Operator's manual

Boomerang
Boomerang Side Car operating instructions

Temcoline
Temcoline T52 user manual