ENTRYPASS N-MINI 2 User manual

Copyright © Entrypass Corporation
ENTRYPASS TECHNICAL –WIRING GUIDE
Version: 1.07
Last Updated: 23-06-2016
EP.N-MINI 2 WIRING GUIDE

Copyright © Entrypass Corporation
ENTRYPASS TECHNICAL –WIRING GUIDE
Technical Support
If you cannot find the answer to your question in this manual or in the Help files, we recommend you
contact your system installer. Your installer is familiar with your system configuration and should be able
to answer any of your questions.
Should you need additional information, please call our Technical Support Help desk, Monday to Friday
9:00 AM to 6:00 PM (GMT +8:00)
Method Details
Phone + 60 (3) - 8068 1929
Fax + 60 (3) - 8068 1922
Internet www.entrypass.net
Email support@entrypass.net
BEFORE YOU BEGIN

Copyright © Entrypass Corporation
ENTRYPASS TECHNICAL –WIRING GUIDE
CAUTION
Battery may explode if mistreated. Do not recharge,
disassemble or dispose of in fire. To prevent a risk of explosion do
not pry the battery out with a metal or conductive tool.
Preparing Your EntryPass Controllers
EntryPass controller contains numerous delicate electronic circuits and components which can become
damaged as a result of electrostatic discharge (ESD). Thus, prior to installation, please follow the instruction
below:
•Observe precautions while handling the circuit board assembly by using proper grounding straps and handling
precautions at all
•Visually ensure no onboard parts is broken, damage or contains burn mark
•Do not turn on the power supply until you completed all wiring and external add on devices installations
Instances of Non-Warranty
•Damage due to natural disaster, accident or human cause.
•Damage as a result of violating the conditions recommended in the user manual
•Damage due to improper installation
•Damage due to use of uncertified components
•Damage due to use exceeding the permitted parameters
Considerations Prior to Installation

Copyright © Entrypass Corporation
ENTRYPASS TECHNICAL –WIRING GUIDE
N-MINI 2 Reader N-MINI 2 DRB
N-MINI 2 Description

Copyright © Entrypass Corporation
ENTRYPASS TECHNICAL –WIRING GUIDE
Heartbeat/Indication
Tricolor LED
CapSense Touch Button
with Backlight
Color LCD
Screen
N-MINI 2 Description

Copyright © Entrypass Corporation
ENTRYPASS TECHNICAL –WIRING GUIDE
CN3 CN2
Tamper
Switch
Rear View
of
N-MINI 2 Reader
CN3 Color Description
(Gray Jacket)
Red : +12V
Orange : +12V
Black : GND
Brown : GND
White : RS485 C1+
Green : RS485 C1-
Yellow : RS485 C2+
Blue : RS485 C2-
CN2 Color Description (Black Jacket)
Cat-5e cable
White Orange : White Orange
Orange : Orange
White Green : White Green
Blue : Blue
White Blue : White Blue
Green : Green
White Brown : White Brown
Brown : Brown
Cat-5e cable can pull from the rear of N-MINI 2 reader straight back to
10/100/1000 Mbps Ethernet switch
N-MINI 2 Reader Color Description

Copyright © Entrypass Corporation
ENTRYPASS TECHNICAL –WIRING GUIDE
JP5: Vout1- Supply
Voltage Selector 1
Relay 2 LED
Buzzer
Relay 1
Relay 2
MCU
Address Dip
Switch
Cold Start SwitchReset Switch
COM Rx/Tx LEDs
RS232 COMs
Heartbeat LED
Cold Start, Factory
Default and Crypto
Key reset Selection
Jumper
Relay 1 LED
RS485 COM
Chip
Dip Switch:
ON
12345
PCB Version
JP6: Vout2- Supply
Voltage Selector 2
Supply Voltage Selector:
Put the jumper cap at JP5 1-2 to output 12VDC at Vout1
Put the jumper cap at JP5 2-3 to output 5VDC at Vout1
Put the jumper cap at JP6 1-2 to output 12VDC at Vout2
Put the jumper cap at JP6 2-3 to output 5VDC at Vout2
3 11 3
JP5 –Vout1 JP6 –Vout2
12V 5V 12V 5V
DRB Components Description

Copyright © Entrypass Corporation
ENTRYPASS TECHNICAL –WIRING GUIDE
+12V - Power Supply +12VDC
GND - Power Supply Ground
EARTH - Power Supply Earth
NC1 - Relay 1 Normally Close
CM1 - Relay 1 Common
NO1 - Relay 1 Normally Open
NC2 - Relay 2 Normally Close
CM2 - Relay 2 Common
NO2 - Relay 2 Normally Open
ACC - AC Fail Monitoring
BATT - Backup Battery Monitoring
IN1 - Input 1
IN2 - Input 2
GND - Ground
IN3 - Input 3
IN4 - Input 4
GND - Ground
GND - Ground
GND - Ground
+12V GNDEARTH NC1 CM1 NO1 NC2 CM2 NO2 ACC BATT IN1 IN2 GND IN3 IN4 GND GND GND
Power Supply
Connector Relay 1 Relay 2 AC Fail
Connector Input 1, 2, 3, 4
Legend Description (DRB)

Copyright © Entrypass Corporation
ENTRYPASS TECHNICAL –WIRING GUIDE
Vout1 - Voltage Supply 1
GND - Voltage Supply Ground
Vout2 - Voltage Supply 2
RD01 - Reader 1 Data 0 Input
RD11 - Reader 1 Data 1 Input
GRN1 - Reader 1 Green LED
RED1 - Reader 1 RED LED
BZR1 - Reader 1 Buzzer
TMP1 - Reader 1 Tamper
RD02 - Reader 2 Data 0 Input (Reserved)
RD12 - Reader 2 Data 1 Input (Reserved)
GRN2 - Reader 2 Green LED (Reserved)
RED2 - Reader 2 RED LED (Reserved)
BZR2 - Reader 2 Buzzer (Reserved)
TMP2 - Reader 2 Tamper (Reserved)
C1+ - RS485 COM1 (+) Connection
C1- - RS485 COM1 (-) Connection
C2+ - RS485 COM2 (+) Connection
(Reserved)
C2- - RS485 COM2 (-) Connection
(Reserved)
Vout1GND Vout2RD01RD11GRN1RED1BZR1TMP1RD02RD12GRN2RED2BZR2TMP2C1+ C1 –C2+ C2 –
Voltage
Supply Reader 1 Reader 2 RS485 1 RS485 2
Legend Description (DRB)

Copyright © Entrypass Corporation
ENTRYPASS TECHNICAL –WIRING GUIDE
ENTRYPASS
Power Supply Unit Specification:
•Switching Power Supply
•12V DC
•3 Amp (MINImum)
Power Supply Unit Specification

Copyright © Entrypass Corporation
ENTRYPASS TECHNICAL –WIRING GUIDE
ENTRYPASS
RS485 C1-RS485 C1+
+12V
GND
+12V
GND
N-MINI 2
Power Supply
BATT/BS/VS
PG
Vout1GND Vout2RD01RD11GRN1RED1BZR1TMP1RD02RD12GRN2RED2BZR2TMP2C1+ C1 –C2+ C2 –
+12V GND EARTH NC1 CM1 NO1 NC2 CM2 NO2 ACC BATT IN1 IN2 GND IN3 IN4 GND GND GND
RST COLD
HRT
MCU RS485
COMM1
RS485
COMM2
Addressing Dip
Switch
Relay 1 Relay 2
GND-ETH
RS232 C1RS232 C2
Selection Jumper
Vout1 Vout2
LED1 LED2
Buzzer
+12V - Power Supply +12V DC
GND - Power Supply Ground
ETH - Power Supply Earthing
ACC - AC Fail Monitoring
BAT/BS - Backup Battery Monitoring
BAT/BS (Backup Battery Monitoring)
point will monitor the backup
battery voltage which will supply
power to the board when AC
power is cut off
The minimum voltage for cutoff
while using backup battery is 10V
Connecting the N-MINI 2 Reader to DRB

Copyright © Entrypass Corporation
ENTRYPASS TECHNICAL –WIRING GUIDE
ON
12345
1 2 4 8 16Addr:
Connecting the N-MINI 2 Reader and DRB –Dip Switch
Addressing
Note: Please identify the PCB version of DRB board for correct Dip Switch Orientation
(refer page 6)
The dipswitch is used for setting the unit address of the DRB to match the RDK
Each switch is represent by an address, the sum of the switch address will be the
controller address
The number in RED color is the address of each individual switch of the dip switch
Example: To obtain Address 11, 1 + 2 + 8 = 11, So just switch on switch 1, 2, 4
Note: Factory Default Unit Address of NMINI2 Reader is 000
To configure the unit address of NMINI2, please go to:
System > System Setting > Unit Address

Copyright © Entrypass Corporation
ENTRYPASS TECHNICAL –WIRING GUIDE
Unit
Address
Switch 1
Switch 2
Switch 3
Switch 4
Switch 5
000
OFF
OFF
OFF
OFF
OFF
001
ON
OFF
OFF
OFF
OFF
002
OFF
ON
OFF
OFF
OFF
003
ON
ON
OFF
OFF
OFF
004
OFF
OFF
ON
OFF
OFF
005
ON
OFF
ON
OFF
OFF
006
OFF
ON
ON
OFF
OFF
007
ON
ON
ON
OFF
OFF
008
OFF
OFF
OFF
ON
OFF
009
ON
OFF
OFF
ON
OFF
010
OFF
ON
OFF
ON
OFF
011
ON
ON
OFF
ON
OFF
012
OFF
OFF
ON
ON
OFF
013
ON
OFF
ON
ON
OFF
014
OFF
ON
ON
ON
OFF
015
ON
ON
ON
ON
OFF
Dip Switch Addressing Table
Binary to Decimal Addressing Table

Copyright © Entrypass Corporation
ENTRYPASS TECHNICAL –WIRING GUIDE
Unit
Address
Switch 1
Switch 2
Switch 3
Switch 4
Switch 5
016
OFF
OFF
OFF
OFF
ON
017
ON
OFF
OFF
OFF
ON
018
OFF
ON
OFF
OFF
ON
019
ON
ON
OFF
OFF
ON
020
OFF
OFF
ON
OFF
ON
021
ON
OFF
ON
OFF
ON
022
OFF
ON
ON
OFF
ON
023
ON
ON
ON
OFF
ON
024
OFF
OFF
OFF
ON
ON
025
ON
OFF
OFF
ON
ON
026
OFF
ON
OFF
ON
ON
027
ON
ON
OFF
ON
ON
028
OFF
OFF
ON
ON
ON
029
ON
OFF
ON
ON
ON
030
OFF
ON
ON
ON
ON
031
ON
ON
ON
ON
ON
Dip Switch Addressing Table
Binary to Decimal Addressing Table

Copyright © Entrypass Corporation
ENTRYPASS TECHNICAL –WIRING GUIDE
+12V GND EARTH NC1 CM1 NO1 NC2 CM2 NO2 ACC BATT IN1 IN2 GND IN3 IN4 GND GND GND
+12V
GND
+12V GND
Emergency
Breakglass
Emergency
Keyswitch
PSU
Electro-Magnetic Lock or Drop Bolt
Connecting the Lock (NC), Breakglass and Keyswitch
Diode(1N4002) must be installed at the locking devices in order to protect against back
EMF. It is advisable to connect EM lock COM to +12V of PSU (Power Supply Unit)

Copyright © Entrypass Corporation
ENTRYPASS TECHNICAL –WIRING GUIDE
+12V GND EARTH NC1 CM1 NO1 NC2 CM2 NO2 ACC BATT IN1 IN2 GND IN3 IN4 GND GND GND
+12V
GND
Electro-Strike Lock
+12V
GND
PSU
Diode(1N4002) must be installed at the locking devices in order to protect against back EMF
Connecting the Striker Lock or Drop Bolt (NO)

Copyright © Entrypass Corporation
ENTRYPASS TECHNICAL –WIRING GUIDE
Door Sensor Push Button
IN1 IN2 GND
+12V GND EARTH NC1 CM1 NO1 NC2 CM2 NO2 ACC BATT IN1 IN2 GND IN3 IN4 GND GND GND
GND
Connecting the Door Sensor and Push Button

Copyright © Entrypass Corporation
ENTRYPASS TECHNICAL –WIRING GUIDE
To configure MINI as a
READER Mode, press:
•F1
•123456
•01 Enter
•01 Enter
•05 Enter
•1 Enter
•ESC x3
Vout1GND Vout2RD01RD11GRN1RED1BZR1TMP1RD02RD12GRN2RED2BZR2TMP2C1+ C1 –C2+ C2 –
Red: +12V
Black: GND
Orange: D0
Yellow: D1
Mini as Reader
Connecting the Reader –MINI as Reader

Copyright © Entrypass Corporation
ENTRYPASS TECHNICAL –WIRING GUIDE
Vout1GND Vout2RD01RD11GRN1RED1BZR1TMP1RD02RD12GRN2RED2BZR2TMP2C1+ C1 –C2+ C2 –
Red: +12V
Black: GND
Green: D0
White: D1
Green LED
Buzzer
Tamper
Connecting the Reader –3rd Party Reader
Put the jumper cap at JP5 1-2 to output 12VDC at Vout1
Put the jumper cap at JP5 2-3 to output 5VDC at Vout1
Put the jumper cap at JP6 1-2 to output 12VDC at Vout2
Put the jumper cap at JP6 2-3 to output 5VDC at Vout2

Copyright © Entrypass Corporation
ENTRYPASS TECHNICAL –WIRING GUIDE
Vout1GND Vout2RD01RD11GRN1RED1BZR1TMP1RD02RD12GRN2RED2BZR2TMP2C1+ C1 –C2+ C2 –
Red: +12V
Black: GND
Green: W-D0
White: W-D1
Yellow (with Black stripe): C2-
Blue (with white stripe): C2+
Note: Connect to N-MINI 2 C2+/C2-
Black: W-GND
+12V GND EARTH NC1 CM1 NO1 NC2 CM2 NO2 ACC BATT IN1 IN2 GND IN3 IN4 GND GND GND
Connecting the Reader –Suprema Biometric Devices
(BioLite Net)
Table of contents