ENTRYPASS N-MINI User manual

Copyright © Entrypass Corporation
ENTRYPASS TECHNICAL –WIRING GUIDE
Version: 1.03
Last Updated: 22-06-2016
EP.N-MINI WIRING GUIDE

Copyright © Entrypass Corporation
ENTRYPASS TECHNICAL –WIRING GUIDE
Notes:
See http://www.entrypass.net/ for updates, revisions, and download the latest
installation manual
There are currently 2 version of EntryPass Platform1 Access Control System available for
different card number system
1) EntryPass Platform1 Access Control System (6 Digit Card Number System) cater for 6
digit card number installation
2) EntryPass Platform1 Access Control System (10 Digit Card Number System) cater for 10
digit card number installation
For EntryPass Platform1 Access Control System to work correctly, both control panel and
software MUST be using the same card number system
This software installation manual might be updated without prior notice
Please refer to separate EntryPass Platform1 User Manual for detail operation help. The
Official EntryPass Platform1 User Manual can be downloaded from our website under
“Download” section

Copyright © Entrypass Corporation
ENTRYPASS TECHNICAL –WIRING GUIDE
Technical Support
If you cannot find the answer to your question in this manual or in the Help files, we recommend you
contact your system installer. Your installer is familiar with your system configuration and should be able
to answer any of your questions.
Should you need additional information, please call our Technical Support Help desk, Monday to Friday
9:00 AM to 6:00 PM (GMT +8:00)
Method Details
Phone + 60 (3) - 8068 1929
Fax + 60 (3) - 8068 1922
Internet www.entrypass.net
Email support@entrypass.net
BEFORE YOU BEGIN

Copyright © Entrypass Corporation
ENTRYPASS TECHNICAL –WIRING GUIDE
CAUTION
Battery may explode if mistreated. Do not recharge,
disassemble or dispose of in fire. To prevent a risk of explosion do
not pry the battery out with a metal or conductive tool.
Preparing Your EntryPass Controllers
EntryPass controller contains numerous delicate electronic circuits and components which can become
damaged as a result of electrostatic discharge (ESD). Thus, prior to installation, please follow the instruction
below:
•Observe precautions while handling the circuit board assembly by using proper grounding straps and handling
precautions at all
•Visually ensure no onboard parts is broken, damage or contains burn mark
•Do not turn on the power supply until you completed all wiring and external add on devices installations
Instances of Non-Warranty
•Damage due to natural disaster, accident or human cause.
•Damage as a result of violating the conditions recommended in the user manual
•Damage due to improper installation
•Damage due to use of uncertified components
•Damage due to use exceeding the permitted parameters
Considerations Prior to Installation

Copyright © Entrypass Corporation
ENTRYPASS TECHNICAL –WIRING GUIDE
N-MINI Reader
Keypad Display Unit
Networked Lock Control
N-MINI Description

Copyright © Entrypass Corporation
ENTRYPASS TECHNICAL –WIRING GUIDE
N-MINI Reader Color Description
Red : +12VDC
Black : GND / 0VDC
Pink : Not In Used
Black : GND / 0VDC
Blue : Not In Used
Brown : Not In Used
White : Exit Reader D1
Green : Exit Reader DO
Orange : Not In Used
Yellow : Not In Used
Grey : Not In Used
Purple : Not In Used
Green : RS232 RX Separated
White : RS232 TX Separated
N-MINI Reader Color Description

Copyright © Entrypass Corporation
ENTRYPASS TECHNICAL –WIRING GUIDE
Networked Lock Control (NLC) Color Description
Networked Lock Control (NLC) Color
Description
Red / Yellow : +12VDC
Black : GND / 0VDC
Orange : Door Sensor
Yellow : Not In Used
Blue : Not In Used
Pink : Push Button
Red : +12VDC
Black : GND / 0VDC
Grey / Yellow : NO1
White / Blue : CM1
White : NC1
Brown : NO2
Grey : CM2
Green : NC2
Purple : +12Vdc Lock
Purple : +12Vdc Lock
Green : RS232 TX Separated
White : RS232 RX Separated

Copyright © Entrypass Corporation
ENTRYPASS TECHNICAL –WIRING GUIDE
White LCD Display
Enter Key
Numbered Keypad
Navigation Pad
LED Indicator
N-MINI Reader Keypad Display Unit

Copyright © Entrypass Corporation
ENTRYPASS TECHNICAL –WIRING GUIDE
Backup Battery
8-Bits Dip Switch
Buzzer
Lock Relay
Wire Connector RJ-45 Network Port
Auxiliary Input
Auxiliary Communication Port
32-Bits Processor
Power LED
Reset Button Cold Start Button
Heart Beat LED
Communication LED
RJ-45 LED
Networked Lock Control (NLC)

Copyright © Entrypass Corporation
ENTRYPASS TECHNICAL –WIRING GUIDE
ENTRYPASS
Power Supply Unit Specification:
•Switching Power Supply
•12V DC
•3 Amp (MINImum)
Power Supply Unit Specification

Copyright © Entrypass Corporation
ENTRYPASS TECHNICAL –WIRING GUIDE
The distance from N-MINI keypad reader to NLC should not more than 30 meter
0 V +12 VDC
Green (RS 232)
White (RS 232)
Red (+12VDC)
Black (Gnd)
Green (RS 232)
White (RS 232)
Black (Gnd)
Red (12+VDC)
ENTRYPASS
Switching Mode
Power Supply Unit
(12V DC, 3A Minimum)
Connecting the N-MINI Reader to NLC

Copyright © Entrypass Corporation
ENTRYPASS TECHNICAL –WIRING GUIDE
Diode(1N4002) must be installed at the locking devices in order to protect against back EMF
+-
White/Blue (CM1)
White (NC1)
0V
Emergency
Breakglass
Emergency
Keyswitch
Electro-Magnetic Lock
-
+
ENTRYPASS
Purple (+12VDC)
Purple (+12VDC)
Switching Mode
Power Supply Unit
(12V DC, 3A Minimum)
Connecting the Lock (NC), Breakglass and Keyswitch to NLC

Copyright © Entrypass Corporation
ENTRYPASS TECHNICAL –WIRING GUIDE
+-
Grey (CM2)
Purple (+12VDC)
0V
Electro-Magnetic Lock
-
+
ENTRYPASS
Purple (+12VDC)
Green (NC2)
Switching Mode
Power Supply Unit
(12V DC, 3A Minimum)
When the implementation is on double leaf type, it is advisable to use the second relay to control
another lock in order to reduce the NLC onboard relay load
Note:
To enable the relay 2 function, on
the N-MINI keypad reader, press:
•F1
•123456
•01 Enter
•01 Enter
•07 Enter
•1 Enter
•ESC x3
Connecting the 2nd Lock (NC) for Double Leaf Type
(Optional)

Copyright © Entrypass Corporation
ENTRYPASS TECHNICAL –WIRING GUIDE
+-
White/Blue (CM1)
Grey/Yellow (NO1)
0V
Electro-Magnetic Lock (Drop Bolt)
-
+
ENTRYPASS
Purple (+12VDC)
Purple (+12VDC)
Switching Mode
Power Supply Unit
(12V DC, 3A Minimum)
Diode(1N4002) must be installed at the locking devices in order to protect against back EMF
Connecting the Lock (NO), Breakglass and Keyswitch to NLC

Copyright © Entrypass Corporation
ENTRYPASS TECHNICAL –WIRING GUIDE
Note:
To enable the relay 2 function, on
the N-MINI keypad reader, press:
•F1
•123456
•01 Enter
•01 Enter
•07 Enter
•1 Enter
•ESC x3
+-
Grey (CM2)
Purple (+12VDC)
0V
Electro-Magnetic Lock (Drop Bolt)
-
+
ENTRYPASS
Purple (+12VDC)
Brown (NO2)
Switching Mode
Power Supply Unit
(12V DC, 3A Minimum)
Connecting the 2nd Lock (NO) for Double Leaf Type
(Optional)
When the implementation is on double leaf type, it is advisable to use the second relay to control
another lock in order to reduce the NLC onboard relay load

Copyright © Entrypass Corporation
ENTRYPASS TECHNICAL –WIRING GUIDE
The distance from NLC to push button and door sensor should not more than 30 meter
Door Sensor Push Button
Orange (Door Sensor)
Pink (Push Button)
Black (Gnd)
ENTRYPASS
Connecting the Door Sensor and Push Button

Copyright © Entrypass Corporation
ENTRYPASS TECHNICAL –WIRING GUIDE
To configure MINI as a
READER Mode, press:
•F1
•123456
•01 Enter
•01 Enter
•05 Enter
•1 Enter
•ESC x3
To configure N-MINI as
aREADER Mode, press:
•F1
•123456
•01 Enter
•01 Enter
•04 Enter
•1 Enter
•ESC x3
0 V +12 VDC
Exit Reader
Switching Mode
Power Supply Unit
(12V DC, 3A Minimum)
Green (D0)
White (D1)
Black (Gnd)
Red (+12VDC)
Black (Gnd)
Red (+12VDC)
Orange (RCLK)
Yellow (RDAT)
Connecting the Exit Reader –MINI/N-MINI Reader as an Exit
Reader
To use MINI/N-MINI on exit reader side, you must enable the READER MODE function on the programming
mode

Copyright © Entrypass Corporation
ENTRYPASS TECHNICAL –WIRING GUIDE
0 V +12 VDC
Green (D0)
White (D1)
Black (Gnd)
Red (+12VDC)
Green (D0)
White (D1)
Exit Reader
Black (Gnd)
Red (+12VDC)
Switching Mode
Power Supply Unit
(12V DC, 3A Minimum)
The distance from MINI to exit reader should not more than 10 meter
Connecting the Exit reader –3rd Party Reader

Copyright © Entrypass Corporation
ENTRYPASS TECHNICAL –WIRING GUIDE
The distance from NLC to network switch should not more than 100 meter
Cat-5 Cat-5
Network Switch
ENTRYPASS
EntryPass Platform1 Access
Control System
Connecting to the PC via Network

Copyright © Entrypass Corporation
ENTRYPASS TECHNICAL –WIRING GUIDE
0 V +12 VDC
Red/Yellow (+12VDC)
Black (Gnd)
ENTRYPASS
Switching Mode
Power Supply Unit
(12V DC, 3A Minimum)
Connecting to Power Supply Unit