erlab Captair Smart 321 User manual

Safer
Simpler
Captair Smart
Ductless filtering fume hoods
User
manual

2
Captair Smart
General....................................................................................................................................3
Safety notices.................................................................................................................3
Product registration ..............................................................................................4
Start-up...................................................................................................................................5
- Calibrating the electronic anemometer
- Default settings
- Description of the control module
- Description of the alarms
e-Guard App.....................................................................................................................9
- Connectivity principle
- Options of connection
- Accessing the Administrator interface
- Administrator interface description
Fan setpoints....................................................................................................................20
Procedure for automatic detection for the saturation
of a molecular filter using acetone......................................................21
- Saturation detection using colorimetric tubes...................................................21
- Saturation detection using PID Device ..................................................................23
- Saturation detection using Molecode S sensor .................................................25
Replacing the filters .................................................................................................27
Recommendations for storing
and using the filters..................................................................................................36
Replacement frequency for filtration breakthrough
sensor (Molecode option).................................................................................37
Admissible weighs on working surfaces........................................37
Cleaning and maintenance.............................................................................38
Contents

3
User Manual
General
By choosing Captair Smart ductless ltration fume hoods, you have chosen an efcient and responsible way to
ensure safety.
Erlab’s 45 years of expertise in the eld of laboratory fume hoods provide unparalleled ltration quality to ensure your
users are properly protected when handling chemicals in the laboratory. The new Captair Smart range uses an innovative
and straightforward mode of communication called Smart technology. This powerful interface uses light to intuitively and
effortlessly communicate with users and leave them free to focus all their attention on the main task: handling the chemicals.
Your ductless Captair Smart ltration fume hood guarantees that you are protected when working with chemicals that pose
an inhalation risk. The Erlab ltration technology it employs traps hazardous particles and molecules and returns clean air
back into the laboratory.
The system’s connectivity allows for real-time safety alerts and individual device usage reports to be sent via the e-Guard
App.
Safety notices
The effectiveness of your device is directly dependent upon it being used correctly and monitored by its users. Your
laboratory may also benet from ergonomic, economic and ecological advantages provided by the Captair Smart fume hood
throughout its life cycle.
The E.S.P. program (Erlab Safety Program) was set up to guarantee your safety. We would remind you that it is important
to have the safety parameters validated before using the device for the rst time and whenever it is used for a different
application.
The handling of substances that are carcinogenic, mutagenic or toxic for reproduction (CMRs) underneath a fume hood is
covered by the French Labour Code. The code notably species that an in-depth risk analysis must be carried out prior to
any CMRs being handled under a recirculating fume hood.
The equipment provided is not intended to be used in an explosive atmosphere.
The lters delivered with this device must be removed from their packaging and positioned correctly; they must also be
suitable for the type of chemicals being handled in order to guarantee user safety.
Erlab recommends that lter breakthrough tests are regularly carried out.
Erlab recommends that the electronic anemometer is calibrated at least once a year.
The quantities of the chemicals handled in the enclosure should not be greater than those listed in the guide to approved
chemicals (the Chemical Listing).
AFNOR standard NF X 15-211: 2009 only applies to chemicals subject to an OEL.
Pursuant to the NF X 15-211 standard, only operations that can immediately be stopped are allowed to be carried out in a
Class 2 enclosure. Moreover, the fume hood’s lter must be replaced if any chemicals are detected downstream of the lter.
New lters must be stored in their packaging, kept in a dry location and laid at. (see recommendations for storing and using
the lters).
Erlab recommends keeping a logbook which is specic to the device and shows the chemical agents handled, how often
they are used and the maintenance operations carried out on it.

4
Captair Smart
Product registration
Take full advantage of the device’s connectivity to enhance your safety
Get up to 10 years warranty on your connected Erlab unit
Register your product online: the registration of the product will automatically give you one extra year of warranty (in addition
to the warranty mentioned in the Erlab’ general terms and conditions of sale).
Connect your unit: Once the device is connected to the Internet and congured to exchange usage data, the warranty is
extended for up to 10 years. Warranty will be successively renewed at each lters replacement and for the life time indicated
on the Valipass® and/or or at the end of lter usage time.
In order to benet from Erlab extension of warranty offer, the following conditions shall be respected:
Warranty applicability is subject to the respect of the Erlab’ general terms and conditions of sale and following requirements:
• The registration and/or the connection of the product shall be performed within the twelve months from the purchase date ;
• Filters replacement must be performed following Valiquest® service recommendations or at the end of lter usage time ;
The lter’s serial number, used as an identication key, validates this condition, regardless of your device’s supplier
(and/or the replacement lter’s supplier for the following years);
• The device’s replacement lters must be manufactured by Erlab, as must all other spare parts.
Consumables such as lters and saturation sensors are not covered under warranty.

5
User Manual
Start up
Calibrating the electronic anemometer
1- Press silmutaneously the main switch while switching on the main swith on the back of the control panel (off:O, ON:I)
2- Release immediately the mute button. A beep will proove the unit has started the calibration mode. LEDS lights will blink
fastly without any sound during 5min. 30 sec. LEDs lights blinking is different when an alarm is triggered.
3- Light blinking stops. The anemometer is calibrated and the unit is operational.
4- Turn on fan of the unit on the control panel.
5- Green light and LEDs lights are lighting.
Good practices :
- If you are using prelters, please be sure they are correctly located
- If you are using Reverso sash (Captair Smart 392 or 483 or 633 or 714 ductless fume hoods), please do the calibration as
indicated.
Main general switch Mute button
Press it silmutaneously
Other manuals for Captair Smart 321
1
This manual suits for next models
6
Table of contents
Other erlab Ventilation Hood manuals
Popular Ventilation Hood manuals by other brands

Gorenje
Gorenje S3 IHGC963S4X manual

KOBE
KOBE ISX2136SQB-1 Installation instructions and operation manual

U.S. Products
U.S. Products ADVANTAGE-100H Information & operating instructions

Kuppersberg
Kuppersberg DUDL 4 LX Technical Passport

Framtid
Framtid HW280 manual

Thermador
Thermador HGEW 36 FS installation manual