Outer Skin Kit & Flue:
IB600, IB850, IB1100
Installation Manual
Please see IB series product installation guide for details of installing the gas fire into this pre-
formed metal cavity.
Important:
The appliance shall be installed in accordance with;
•This installation instruction booklet
•Local gas fitting regulations
•Municipal building codes
•Electrical wiring regulations
•AS 5601, Gas installations / NZ5261 Gas Installation
•Any other relevant statutory regulations.
•Must be installed by a qualified person
Manufactured by: Escea Ltd, PO Box 5277 Dunedin NZ, Ph: +64 3 479 0302, email: [email protected]
For contact details of your local escea distributor or dealer please visit www.escea.net

630077_5 Outer Skin Kit Installation Manual.doc
2
Note:
THERE ARE TWO MAIN THINGS TO CONSIDER BEFORE INSTALLATION
•You will need to get 230/240 Volt power supply to the back right corner of the cavity
•You will need to get gas pipe to one of the three corners of the cavity by removing a
knock out
Install gas lines to
any of these 3 points.
Leave enough piping
to reach the front
right hand corner of
the OSK once
installed.
Electrical
point of
entry.
Final gas connection point
(after OSK installation)
Plan view from top looking down.
Gas pipe

630077_5 Outer Skin Kit Installation Manual.doc
3
Contents: Section:
•Product Description 1.0
•Creating the Cavity 2.0
•Hearth 3.0
•Raised Installations Up a Wall 4.0
•WallLinings 5.0
•Mantle Clearance 6.0
•Television Clearance 6.1
•Corner Installations 7.0
•Power Supply 8.0
•Installing the Flue System 9.0
•Flue Assembly (NZ ONLY) 10.0
•Flue Assembly (Australia ONLY) 10.2
•Flue Clearance 10.5
•Assembling the Outer Skin Kit 11.0
•Fixing the Outer Skin Kit to the Cavity 12.0
•Laying Gas Pipe 13.0
•Gas Fireplace Installation 14.0
•Attaching the Flue to the Fireplace 15.0
•Securing the Flue Sleeve 16.0

630077_5 Outer Skin Kit Installation Manual.doc
4
345
B
A
62
45
45
48 190
475
565
560
700
350
345
56
47 200
585
48
46
470
565
1.0 Product Description:
The Escea IB600 Outer Skin Kit (New Zealand only), IB850 Outer Skin Kit and IB1100 Outer
Skin Kit are to be used for all installations. They seal the cavity and isolate the fire from air
pressure changes within the cavity.
The only instance that the OSK might not be fitted is in a New Zealand installation within a
full masonry chimney that is not open to any other building space. If the top of the chimney
is not present and the cavity is open to the roof space then an OSK must be used.
1.1 Outer Skin Kit (OSK) Dimensions:
IB850 & IB1100
IB600
A B
IB850 960mm 480mm
IB1100 1260mm 630mm

630077_5 Outer Skin Kit Installation Manual.doc
5
2.0 Creating the Cavity:
NOTE: When using designer series fascia options the fire cavity dimensions are different.
Check individual fascia instructions for more details.
The dimensioned drawing below shows the size of opening that must be created to fit the
Outer Skin Kit.
Note: It is not necessary to line the cavity.
2.1 Where possible, it is recommended that cavity is made slightly larger than the above
dimensions to give the installer the maximum amount of space to work in.
3.0 Hearth:
If this fire is being installed at floor level a hearth made from non-combustible material must
extend no less that 300mm from the front of the fire. This hearth should be at least as wide
as the fire’s outer fascia and no less than 10mm thick. Raised hearths can be any size but
must also be constructed from non combustible materials.
3.1 The floor in front of this hearth will still get warm so if floor covering is vinyl, nylon carpet or
other heat sensitive material then we recommend extending the hearth to 450mm from the
fire.
3.2 NOTE: If the hearth is to be covered with tiles or some other veneer then the fire must be
installed so that the base of the ‘Outer Skin Kit’ is level with the finished top surface of the
hearth.
4.0 Raised Installations Up a Wall:
If the fire is being located in such a way that the bottom of the cavity is any more than
100mm up off the ground no hearth is required. Escea recommend that if a heater is being
mounted more than 100mm up a blank wall and no hearth is being used, then a four sided
fascia is used (available from your Escea dealer).
5.0 Wall Linings: The front mounting flanges of the ‘Outer Skin Kit’ MUST be on top of the
FINISHED wall surface in order for the fascia panels to mount properly. Take into account
any plaster board, tiles or any other finishing surface that may be intended for the finished
wall surface. Wall finishing materials must not encroach upon the minimum cavity
clearances given in section 1.0. The wall board that lines the outside of this opening can be
normal dry wall (plaster board) and does not need to be non-combustible providing that it
does not come any closer to the fire than the dimensions shown in section 2.0.
Note: The temperature of the wall lining directly above the heater does get warm and hence
may discolour paint finishes that are susceptible
to temperature damage or distort vinyl wall coverings. For durability of finishes and surfaces
you should contact the relevant manufacturer for their specification.
Ideal Cavity Dimensions:
All dimensions in millimetres
A B C
IB600 700 585 565
IB850 960 560 565
IB1100 1260 560 565
IB Series