manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Etlin-Daniels
  6. •
  7. Camera Accessories
  8. •
  9. Etlin-Daniels ER302D-WHM-A13-BB-10RC User manual

Etlin-Daniels ER302D-WHM-A13-BB-10RC User manual

Head Ofce - 1850 Wilson Ave. · Toronto, ON · M9M 1A1 · Tel: 416.741.7336 · Fax: 416.741.9104 ·
Toll Free: in Canada. 1.800.661.9610 · in USA. 1.888.762.5384 (SOCKETS4U)
www.etlin-daniels.com· For sales/service questions - [email protected]
SAVE THESE INSTRUCTIONS - READ ALL INSTRUCTIONS CAREFULLY
IMPORTANT SAFEGUARDS
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
• Review the diagrams thoroughly before beginning.
• All electrical connections must be in accordance with local codes, ordinances and the
National Electric Code.
• All unused wires must be capped to prevent shorting.
• Disconnect power at fuse or circuit breaker before installing or servicing.
• Do not use outdoors.
• Do not mount in hazardous locations or near gas or electric heaters.
• Do not let power cords touch hot surfaces.
• Equipment should be mounted in locations and at heights where it will not be subject to
tampering by unauthorized personnel.
• The use of accessory equipment is not recommended by the manufacturer.
• Do not use this equipment other than intended use.
• All servicing should be performed by qualied personnel only.
• Allow battery to charge for 24hrs before rst use.
WIRING DIAGRAM
WALL MOUNT
INSTALLATION INSTRUCTION
1. Turn off AC power.
2. Remove all components from packaging.
1. Feed AC supply wires into the junction box leaving 8 inches of wire (see gure 1).
2. Remove the cover by unscrewing the screws on the side of the front cover (see gure 2).
3. Identify the proper hole pattern in the back of the housing to mount to a standard junction box. Place a
support on either side of the knockouts to be removed and then knock out with a screwdriver (see gure 3).
4. Insert a plastic bushing into the hole to protect wires from metal edge. (see gure 4).
5. Route AC supply wires into the center hole of the housing (through the bushing).
6. Mount the unit securely to the junction box using the junction box screws. Note: Use the keyhole slot as
added security (see gure 5).
INSTALLION – ER302D-WHM-A13-BB-10RC
LED METAL EMERGENCY BATTERY UNIT DUAL HEADS
7. The system can accept input voltages of 120 or 347 VAC. Connect the green ground (see wiring diagram above).
8. Install the battery (ies) into the housing and complete the appropriate connections including connection
to the PCBA. Note: Batteries may be shipped separately to avoid damage.
9. Secure all internal wires.
10. Replace and secure the cover with screws (see gure 5).
11. Turn on AC power supply.
FIGURE#1
FIGURE#4 FIGURE#5
FIGURE#2 FIGURE#3
WORKING VOLTAGE:
DC6V - 12V
ATTENTION!!
AC120V 50/60Hz
AC347V 50/60Hz
WIRING DIAGRAM
fuse
Red Wire:AC347V (L1)
Black Wire:AC120V (L2)
White Wire (N)
MAIN PCBA
For BATT
Black -
LAMP2
LAMP1
2*5W/LED
Output:
DC 6V
Input cable
AC WIRING
Red +
TEST
Green led
(AC ON)
Lamp Head
Transformer
Battery
Green Wire (E/G)
6V/6Ah
LAMP/n
24W/LED
Junction Box
Head Ofce - 1850 Wilson Ave. · Toronto, ON · M9M 1A1 · Tel: 416.741.7336 · Fax: 416.741.9104 ·
Toll Free: in Canada. 1.800.661.9610 · in USA. 1.888.762.5384 (SOCKETS4U)
www.etlin-daniels.com· For sales/service questions - [email protected]
SAVE THESE INSTRUCTIONS - READ ALL INSTRUCTIONS CAREFULLY
ADJUST THE LAMP HEAD
Rotation - hold each lamp head and turn it to either side.
Tilt - hold each lamp head and tilt it up or down. OPERATION:
Self-powered (battery)
a.) To test, depress the TEST button. The charge indicator will go out and the lamps will come on.
b.) Release the TEST button. The lamp will turn off, and the charge indicator will come on.
c.) The LED indicator light indicates a high charge rate. After the battery has reached full charge. the
indicator light will go out. Under normal operation, the high charge indicator will turn on and off intermit-
tently while the unit is in standby mode.
MAINTENANCE:
1. Equipment must be tested regularly in accordance with local codes.
2. Replace the batteries as needed according to ambient conditions.
3. Clean the front cover on regular basis to provide maximum light distribution.
TROUBLESHOOTING:
THE LAMPS DO NOT LIGHT
Check the AC power supply.
AC supply is OK, and indicator light is out, replace the PC board assembly.
The pilot light is on before the test. Either the output is shorted or overloaded, or the battery is not
connected.
Battery has discharged. Allow 24 hours for recharge and then retest.
THE LAMPS COME ON DIM WHEN THE TEST BUTTON IS PRESSED
Battery is discharged-allow the unit to charge for 20 hours and retest. If lamps are still dim, check to see if
the charger is working. If the charger is functioning correctly, replace the battery.
THE LAMPS COME ON DIM WHEN THE BATTERY IS FIRST CONNECTED
Battery may be connected in reverse polarity. Check the connections. Connect the positive lead to the
positive battery terminal and the negative lead to the negative battery terminal. The lamps should then
turn off and the charge indicator should light up when AC power is applied.
THE LAMPS COME ON DIM WHEN AC POWER IS ON
Check the supply voltage and the AC connections. The AC supply must be atleast 80% of the nominal
voltage
(96V on a 120V line) for equipment to function normally. At lower voltages the emergency headlights will
begin to glow dimly until the source voltage drops below the battery full turn-on point. NOTE: This condi-
tion may also be caused by incorrectly connecting a 120 V supply line to the 347V transformer lead.
NOTHING HAPPENS WHEN THE UNIT IS ENERGIZED
Some models have a standard time delay built into the design of the charger board. Please allow 15 min-
utes when the AC supply is connected. At this point the LED AC-ON and CHARGE lights should illuminate.
The unit comes with a 3 year xture and 1 year battery warranties
INSTALLION – ER302D-WHM-A13-BB-10RC
LED METAL EMERGENCY BATTERY UNIT DUAL HEADS

Popular Camera Accessories manuals by other brands

CamRanger CamRanger user manual

CamRanger

CamRanger CamRanger user manual

Custom Brackets HDV CAGE KIT Instructions for use

Custom Brackets

Custom Brackets HDV CAGE KIT Instructions for use

Aegis ABL052010P user manual

Aegis

Aegis ABL052010P user manual

Saft SRA Series Installation and operating instructions

Saft

Saft SRA Series Installation and operating instructions

Kodak TIB5200 technical information

Kodak

Kodak TIB5200 technical information

Videotec HEG instruction manual

Videotec

Videotec HEG instruction manual

Ikelite 6171.11 manual

Ikelite

Ikelite 6171.11 manual

Pentax Auto Bellows Slide Copier K user manual

Pentax

Pentax Auto Bellows Slide Copier K user manual

Nikon UT-1 user manual

Nikon

Nikon UT-1 user manual

dji RONIN 4D quick start guide

dji

dji RONIN 4D quick start guide

SLIK ABLE 300DX user manual

SLIK

SLIK ABLE 300DX user manual

Rebelcell 36V70 user manual

Rebelcell

Rebelcell 36V70 user manual

Trojan GC2 48V quick start guide

Trojan

Trojan GC2 48V quick start guide

Calumet 7100 Series CK7114 operating instructions

Calumet

Calumet 7100 Series CK7114 operating instructions

Ropox 4Single Series User manual and installation instructions

Ropox

Ropox 4Single Series User manual and installation instructions

Cambo Wide DS Digital Series Main operating instructions

Cambo

Cambo Wide DS Digital Series Main operating instructions

Samsung SHG-120 Specification sheet

Samsung

Samsung SHG-120 Specification sheet

Ryobi BPL-1820 Owner's operating manual

Ryobi

Ryobi BPL-1820 Owner's operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.