Ewtx MR-K User manual

Mr-K
USER’S MANUAL

MR-K SPARK MACHINE
Table of content
1.
Safety instructions ...............................................................................................
3
1.1.
For safe and efficient operation ...................................................................
3
2.
Intended use of the device ..............................................................................
4
2.1.
Connections ....................................................................................................
6
2.2.1.
Electrical connections.............................................................................
6
2.2.2.
DMX connections .....................................................................................
7
2.3.
2.4.
7
Wireless remote / Dip switch 4 channel...........................................................
Wired remote controller.....................................................................................
3.
Introduction.........................................................................................................
8
3.1.
Product description ........................................................................................
8
4.
Before using .........................................................................................................
9
5.
Control buttons ...................................................................................................
9
6.
User Interface ....................................................................................................
10
6.1.
Status interface .............................................................................................
10
6.2.
Menu...............................................................................................................
10
6.3.
DMX Interface ...............................................................................................
10
7.
Operation ..........................................................................................................
11
7.1.
Manual Operation ........................................................................................
11
8.
Operation via DMX .......................................................................................
11
9.
Settings...............................................................................................................
12
9.1.
DMX address ..................................................................................................
12
9.2.
Fan speed setting .........................................................................................
12
10.
RFID card ...........................................................................................................
12
10.1. How to use the card .................................................................................
12
10.2. How to check the remaining time ..........................................................
12
11.
Technical data ................................................................................................
13
2 / 14

MR-K SPARK MACHINE
1. Safety instructions
This device is suitable for indoor use (not outdoors) only.
Unauthorized modifications will invalidate the warranty.
Repairs are to carry out by skilled workers only.
Use only fuses of the same type and original parts as spare parts.
To avoid fire and electric shocks protect the unit from rain and humidity.
The safety distance to the audience must be 2 metres.
1.1. For safe and efficient operation
Be careful with heat and extreme temperatures!
Do not place the device in a location where it is exposed to
extreme temperatures.
Operate the device only in an ambient temperature between 0°C (32°F) -
40°C (104°F). Do not expose the device to direct sunlight or heat sources.
Keep away from humidity, water and dust!
Avoid placing the device in a location with high humidity or excessive
dust. Place no liquids on or near the system.
Place the device on a firm ground!
To avoid vibrations always place the device on a firm ground.
Do not use chemicals for cleaning!
Use a clean and dry cleaning rag to remove dust. Metal parts can be
cleaned with a damped cleaning rag. Before cleaning always unplug the
device from the power supply.
If the device is not working properly!
If problems occur unplug the device from the power supply. The user
should not try to service the device independently. All repairs and service
must be performed by a qualified technician.
Take proper care with the power cord!
Never pull the power cord to disconnect the device from the power supply,
but remove the plug with plug housing in the hand. If you do not use the
device for an extended period, unplug the device from the power supply.
ATTENTION!
Damages caused by the disregard of this user manual are not subject to
warranty. The dealer will not accept liability for any consequent secondary
failures. Only skilled workers are allowed to carry out the electrical
connections. All electrical and mechanical connections have to be carried
out according to the European safety standards.
3 / 14

MR-K SPARK MACHINE
2. Intended use of the device
This device was developed for professional use on stages, in discos,
theatres etc. The device is only approved for a connection up to 230 V
50/60 Hz alternating current and only for indoor use.
Regular breaks during operation increase the lifetime of your device.
Avoid convulsions or any form of forceful impact during the installation or the
startup of the device.
Take care that no cables are lying around. You would endanger your
own safety and also the safety of a third party.
It is not allowed to operate or store the device in an environment in which
spray water or rain is expected. Humidity or very high atmospheric humidity
could reduce the isolation of the device and could cause deathly electric
shocks.
Operate the device not during thunderstorms. Surge voltages could destroy
the device. Unplug the power supply during thunderstorms.
Surrounding objects or surfaces should not be in contact with the device.
Make sure that during the installation and removal of the device the area
below the place of installation is basically cordoned off. This also applies
to implementation of service.
Make familiar yourself with the functions of the device before start-up.
People without the experience should not handle with the device. The most
cause of functional disorder is inappropriate handling.
Keep the device away from children and never operate it unattended.
Never aim the nozzle on people and keep a distance from 1meter to the
nozzle.
Keep a minimum distance of 1meter to other objects.
Use only the recommended, high quality granule from your dealer.
Other fluids may cause damages.
Never aim the nozzle on open fire or flammable objects.
Operate the unit only in a horizontal position.
Never use solvents or aggressive detergents for cleaning. Use instead of this a
damped cleaning rag.
To prevent damages during transport use for transport the original packing
or provided accessories.
For reasons of safety unauthorized changes are forbidden!
4 / 14

MR-K SPARK MACHINE
A usage of the device which differs from usages which are described in this
manual can cause damages of the device. In this case the warranty expires.
Additional you should notice that every different usage is related with
dangers and can cause e.g. an electrical short, fire, electric shock or crash.
2.1. Overhead installation
Danger of life!
You have to observe the regulations of BGV C1 (formerly VBG
70) and EN60598-2-17 Installations are to carry out by
skilled personnel only.
The suspension devices have to be build and measured so they
can withstand for an hour the tenfold of the payload without
suffering a permanent detrimental deformation.
Basically installation has to be made by using a second separate suspension.
This can be e.g. a suitable net. The second suspension must be designed and
attached so no part of the installation can fall down in case of failure.
During construction, reconstruction and deconstruction unnecessary stay in
the range of moving areas, on lightning bridges, under elevated work
stations or any other danger zones is forbidden.
The operator is obliged to following safety-related and mechanical facilities:
Before the first start-up or after critical changes before restarting it has
to be checked by an expert.
Review in the frame of the inspection test at least all four years by an
expert. .
Review by a qualified person at least once a year.
5 / 14

MR-K SPARK MACHINE
2.2. Connections
2.2.1. Electrical connections
Connect the fixture to the mains with the enclosed power cable and plug.
The earth has to be connected.
Cable (EU)
Cable (US)
Pin
International
Brown
Black
Live
L
Light blue
White
Neutral
N
Yellow/Green
Green
Earth
6 / 14

MR-K SPARK MACHINE
2.2.2. DMX connections
Make sure that you use shielded cable. 3 pol XLR cables are suitable.
2.3. Wireless Remote / Dip Switch 4 Channel
When the heating process is finished,
the green light lights up and
indicates that the button on the remote
control can be pressed. If heating is not
complete, the green light does not light
up and the red light is on,
then the remote control cannot be
operated. 4 channels can be selected,
suitable for 1,2,3,4, if only 1 channel is used,
the others are closed.
frequency 315MHz
2.4 Wired Remote controller
When the heating process is finished,
the green light lights up and
indicates that the button on the remote
control can be pressed. If heating is not
complete, the green light does not light
up then the remote control cannot be
operated.
_____________________________________________________________________________________________________
7 / 14

MR-K SPARK MACHINE
3. Introduction
Thank you for choosing the EWTX MR-K
We recommend that you carefully read these operating instructions before
commissioning the unit. Please follow the instructions in this manual. This is
the only way to ensure safe operation, proper use and long service life.
3.1. Product description
1. Nozzle
2. Feed port
3. Handle
4. Fuse
5. On/Off switch
6. Power ‚output
7. Power , input
8. XLR 3 pol / in
9. XLR 3 pol / out
10. Cable controller plug
11. Induction Zone Card
12. LC Display
8 / 14

MR-K SPARK MACHINE
4. Before using
Remove before start-up every packing material.Place the unit on a level, dry
surface. The machine is not allowed to be turned upside down or angled.
Make sure she stands up straight. Otherwise the machine will be damaged.
1. After verifying that the unit is intact and complete, please place it on
a level surface.
2. Now you have to fill in the granules. More information for this you
can read on the packing of the granules. You are only allowed to
use the granules of EWTX.
3. Connect the device to the power supply.
4. The device starts to heat up. This process needs 5 minutes,
meanwhile the display shows „UP”.
5. The heating process is finished. The display shows „Ready“.
5. Control buttons
9 / 14
Button
Function
MENU
Navigation through the menu.
▲
Increase a value or make a setting.
▼
Decrease a value or make a setting.
ENTER
Back to the root menu.

MR-K SPARK MACHINE
6. User Interface
6.1 Status interface
Advice
Description
UP
The unit is pre-heating, need 5 Minutes.
READY
The unit is ready for spark effect.
6.2. Menu
6.3. DMX Interface
10 / 14
Menu
Function
Addr
1-512
Setting the DMX address.
Time
0030
Shows up the User time for Spark in
Minutes.
Fan
1-10
Setting the fountain height.
Display
Meaning
001 / 1
The unit is ready to work. Current DMX
address is 1.

MR-K SPARK MACHINE
7. Operation
If the device is in a good condition, it can start a fountain for 15
minutes continuously with a volume of 100% - 255 for a fountain
height of 3-5 meters depends which powder you use (Indoor
3m/Outdoor 5m)
8. Operation via DMX
Channel
Value from
Value to
Function
0
0
No Function / STOP
3
35
Height 1
36
60
Height 2
61
85
Height 3
86
110
Height 4
1
111
135
Height 5
135
160
Height 6
161
185
Height 7
186
210
Height 8
211
235
Height 9
236
255
Height 10
11/ 14

MR-K SPARK MACHINE
9. Settings
9.1. DMX address
Connected to DMX signal, the unit will display “001 / 1 in the LCD screen. Or
press “MENU” button till pages “ ADDR”. Through “▲” and “▼”to set the
address
9.2. Fan speed setting
Press “MENU” Button till page “FAN”. Adjust the fan speed through “▲” and
“▼”. Maximum speed is 100.
10. RFID card
10.1.How to use the card
Tap the IC Card to the Induction zone to activate the unit. Each card
enables the unit to work 30 minutes. In the meantime, the IC card will be
invalid after being read.
10.2. How to check the remaining time
Press “Menu” buttons till the page “Time” to check the remaining time
(minutes ) of using. Tap another new card to re-activate the unit when the
time is over.
12/ 14

MR-K SPARK MACHINE
11. Technical data
Voltage
AC 220 V; 50 Hz
Power consumption max.
850 W
Heating-time
5 Minutes
Consumption
14 g/min
Height of the fountains
1-5 Meter
Number of DMX channels
1
Remote / Frequency 315 MHz
Yes
Dmx 1-512
Yes
XLR 3 pol in / out
Yes
Power in
P-Con
Wired remote Controller
Yes
Dimensions
248x244x322 mm
Weight
10,1 Kg

______________________________________________________________________________________________________
13 / 14

MR-K SPARK MACHINE
Importer:
Sebo GmbH
Bömmerstr 32
D-58454 Witten
www.sebogmbh.de
14/ 14
Table of contents
Popular Dj Equipment manuals by other brands

Pioneer
Pioneer DDJ-SX2 Service manual

Pacific Research
Pacific Research BMX-III-18 Operation and technical manual

BoomToneDJ
BoomToneDJ VHF-10M Operation manual

City Theatrical
City Theatrical SHoW BABY 5 quick start guide

Beamz Pro
Beamz Pro LCB366 user manual

Chauvet
Chauvet Hurricane 2000 Quick reference guide