FarmTek 116192 User manual

Galvanized Box Fans—Direct Drive
Instruction Manual
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain
the equipment described within this manual. Carefully follow all safety information.
Save this manual for future reference.
Model # _______________________________
Purchase Date: _________________________
Date: 04/27/18
Form: HV0022 Version 3
Model Numbers Covered:
116192, 115237, 116189

Specifications
Getting Started
Tools/Materials Needed:
• Drill/drill bits
• 5/16” nut driver
• Construction screws
• Caulk or sealant
Contents:
• Galvanized box fan(1)
• Instruction manual(1)
Inspection:
After unpacking your fan, carefully inspect for any damage that may have occurred during transit. Inspect for loose, missing or damaged parts. If
there is physical damage to any parts of the fan, a freight claim must be filed with the carrier. Check to assure that all bolts, screws and set screws
are securely tightened and have not become loose during transit. Retighten as required. Rotate propeller by hand to assure it turns freely.
General Safety Instructions
Danger: Before installing or servicing, always lock out and tag power source. Do not rely on a switch as the only means
of disconnecting power. Failure to disconnect power can result in fire, electrical shock or serious injury. Motor will restart without
warning after thermal protector trips. Do not touch an operating motor as it may be hot enough to cause injury. Do not place any body
parts or objects in fan or drive components while fan is connected to a power source.
Warning:
1. Read and follow all instructions, cautions, dangers and warnings. Failure to do so could result in personal injury, death or property damage.
2. Make sure the electrical power source conforms to the requirement of the fan(s) as well as local codes.
3. Electrical connections, installation and maintenance must be done by qualified electrical personnel in accordance with all applicable codes and
ordinances.
4. Unit must be adequately grounded.
5. To reduce the risk of fire or electrical shock, do not expose this fan to water.
6. Do not touch electrically live components.
7. Free rotation of the propeller is critical. It must not touch any part of the venturi, framework or drive components.
8. Assure that all power cords do not come in contact with any sharp edges, hot surfaces or chemicals. Immediately replace any damaged cords.
Caution: OSHA requires OSHA compliant guards when fan is installed within 7ft of the floor or working level.
Dimension (In.) Rough-in Opening
Model Prop Dia. A B D Height Width Ship. Wt Ship. Dims.C
116192 36” 40 1/8 14 3/8 40 3/4 40 3/4 118 44x18x47-
116189 36” 40 1/8 14 3/8 40 3/4 40 3/4 138 48x18x4717
115237 48” 52 1/8 17 3/8 52 7/8 52 7/8 165 56x20x58-

Troubleshooting Guide
Symptom Possible Cause(s) Corrective Action
Fan will not start 1. Tripped circuit breaker 1. Reset circuit breaker
2. Defective motor 2. Repair or replace
3. Incorrectly wired 3. Shut off power, check for proper connections
4. Electricity turned off 4. Contact local power company
Excessive noise or vibration 1. Blade is hitting housing 1. Free blade of obstruction
2. Blade is bent 2. Replace blade
3. Fan not securely anchored 3. Secure properly
4. Bad/noisy bearings 4. Replace motor
Insufficient airflow 1. Incorrect voltage applied 1. Wire properly
2. Defective motor 2. Replace motor
3. Propeller is damaged 3. Replace propeller
4. Blocked Airflow 4. Remove obstructions
5. Not enough intake air 5. Add additional air intake openings
6. Fan is dirty 6. Clean fan guards/screens, motor and propeller
Motor overheats or trips out 1. Over/under line voltage 1. Contact local power company
2. Defective motor 2. Replace motor
3. Fan is dirty. 3. Clean fan guards/screens, motor and propeller
4. Not enough intake air 4. Add additional air intake openings
Fan Installation
Caution: Before operating your new fan, check blade for proper torque, check all fasteners for tightness and assure
screens and/or shutters are securely in place.
For framing dimensions, refer to rough-in opening height and width shown in the specifications above.
Position the fan for desired airflow. Air will discharge on the side of the fan facing the propeller.
Assure the fan is fastened securely in the opening to avoid excess “rattling” or vibration using proper fasteners. Fasteners not included.
Refer to motor nameplate for wiring diagram.
Maintenance
Periodic maintenance schedules should be set to assure reliability and performance of the fan. This maintenance should included inspection
of all fasteners, propeller torque and proper cleaning of the complete fan assembly.
Check for excessive vibration while fan is running.
Periodically inspect and tighten all set screws and hardware.
Assure all mounting hardware, chains, etc. are properly secured.
Motors feature permanently sealed ball bearings and require no further lubrication.
The fan propeller should be periodically cleaned to assure proper balance and performance.
Performance
CFM(115/230v) CFM/Watt(115/230v)
Model HP F.L.A. Volt. Ph Hz Motor
RPM
0.00"
SP
0.05"
SP
0.10"
SP
0.15"
SP
0.00"
SP
0.05"
SP
0.10"
SP
0.15"
SP
Db
0.00"
SP
116192 1/2 5.2/2.8-2.6 115/208-230 160 825 11,077 10,217 9,381 8,557 21.1 18.6 16.4 14.5 76
116189 1/2 5.2/2.8-2.6 115/208-230 160 825 10,525 9,698 8,910 8,130 20.6 18.2 15.9 14 77
115237 111.0/5.5 115/230 160 850 18,926 17,481 15,973 14,256 19.9 17.8 15.8 13.7 80

Repair Parts Illustration
Note: Aluminum discharge shutter not shown.
Ref No Description 116192 116189 115237 Qty
1 Intake & discharge screen 36SCREEN-N 36SCREEN-N 48SCREEN-N 2,1
3 Clip for screen CLIP-SC CLIP-SC CLIP-SC 24
4 Motor B370-8E B370-8E A750-8VE 1
5 Upright frame piece N/A N/A N/A 2
6(A,B,C,D) Side panel piece N/A N/A N/A 4
9 Venturi panel N/A N/A N/A 1
12 Propeller 9001481 9001481 9001567 1
13 Motor mounting plate N/A N/A N/A 1
- Alum discharge shutter N/A SA36DX N/A 1
This manual suits for next models
2
Table of contents
Other FarmTek Fan manuals
Popular Fan manuals by other brands

Vornado
Vornado Traditions 125ST owner's guide

Salda
Salda RIS 1200PE/PW EKO 3.0 Technical manual

PennBarry
PennBarry RAU Operation and maintenance manual

Vortice
Vortice CA 100 MD Instruction booklet

Ruck Ventilatoren
Ruck Ventilatoren EM EC Series Assembly instruction

Hunter
Hunter Ridgefield 51107 installation manual