FarmTek 101482 User manual

HIGH VELOCITY AIR
CIRCULATOR
MODEL:
UL#E144918
OWNER’S MANUAL
READ&SAVE THESE INSTRUCTIONS

HIGH VELOCITY AIR CIRCULATOR
ASSEMBLY AND OPERATING INSTRUCTIONS
CAUTION: Read and follow all instructions before operating fan. Do not use fan if
any part is damaged or missing.
WARNING: To reduce the risk of fire or electrical shock, DO NOT use this fan with
any solid state speed control device. This appliance has a 3-prong grounded plug
that must be inserted into a matching outlet. To reduce the risk of electrical shock,
this grounding plug must not be removed from the plug. Where a two-prong wall
outlet is encountered, it must be replaced: contact a qualified electrician. DO NOT
attempt to remove this safety feature. Use your fan only with adequate wiring that is
up to Code. Connect to properly grounded outlets only.
RULES FOR SAFE OPERATION:
● Always unplug unit for cleaning.
● Always unplug unit when not in use.
● Always unplug when moving unit from one location to another.
● Do not place foreign objects through guard when fan is in operation..
● Do not operate without fan guards properly locked.
● Do not use this fan with an extension cord.
● Do not use fan in windows. Rain and moisture may create an electrical hazard.
● Do not place fan or any parts near an open flame, cooking or other heating
appliance.
● Do not operate this unit with a damaged cord or plug, especially when this unit
has malfunctioned, or been dropped or damaged.
● Make sure fan is on a stable flat surface when in operation.
● Close supervision is necessary when this unit is used by or near children.
UNPACK YOUR FAN AND CHECK THE CONTENTS
● Front &Rear Guard
● Fan Blade Assembly
● Support Post
● ExtensionPipeAssembly
● Shock Absorbent Spring
● Base Cover
● Motor Assembly
● Hardware package

ASSEMBLY INSTRUCTIONS
1. Remove five hexagonal screws from
base, save them for step 2.
2. Attach support post to base by
tightening back the five hexagonal
screws from step 1 and slide
coupler cover onto base.
3. Slide shock absorbent spring into
support post.
4. Loosen height adjustment knob and
remove two set screws on black ring
around extension pipe, save them for
step 5.
5. Slide extension pipe into support post.
Fix black ring onto support post by
tightening back two set screws from
step 4.

6. Adjust extension pipe to your desired
height and secure it by tightening back
the height adjustment knob.
7. Remove tilt adjustment knob and hexagonal
Bolt from the top of the extension pipe, then
remove the large hexagonal bolt, nut, spring
washer from the top of the extension pipe.
Save them for step 6.
8. Carefully insert the large hexagonal bolt
into the hole and the other smaller bolt
into slots to fix the fan head assembly to
the extension pipe .
9. Carefully insert the large Hexagonal nut,
spring washer and flat washer through
the large hexagonal bolt, and make sure
to tighten it. Fix tilt adjustment 3 prong
knob with the smaller hexagonal bolt .
10. Remove four hexagonal nuts, spring
washers and flat washers from motor
through bolts. Set rear guard in proper
position and fix to motor through bolts
by securing back the nuts and washers
removed.

11. Install fan blade assembly onto motor
shaft by tightening the set screw on blade
assembly to the sunken space on motor
shaft. Make sure set screw is tightly
secured by a Philips-head screw driver
(not provided).
12. Assembly front guard to rear guard by fixing both
guards together with clips on the rim of front
guard.
13. Adjust extension pipe to your desired height
and secure it by tightening the height
adjustment knob. Pass the supply cord
through cord warp clip.
OPERATING INSTRUCTIONS:
1. Set fan on a dry, stable, flat surface.
2. Connect power plug to any standard 120-volt AC outlet. Caution: Make sure
the Speed Control is in the off position.
3. Pass the Supply Cord through Cord Warp Clip.
4. Pull the chain on the motor assembly to set to the desired setting –The pull
chain controls the fan speed as follows: 1 pull-Low, 2 pulls-Medium, 3 pulls-
High and 4 pulls-Off.
5. To change the tilting angle of the Fan Head, Loosen the Tilt Adjustment Knob
on the fan head joint,, tilt the Fan Head to the desired angle and tighten 3
prong knob.
Note :It is normal for the motor to feel warm to touch during operation. The motor is
thermally protected and will automatically shut off when it overheats for any reason.
If this happens immediately disconnect the fan from the power outlet.

The motor bearings are permanently lubricated at the factory and do not require
any additional lubrication.
CLEANING
WARNING: Unplug from electrical supply source before cleaning. After servicing,
any safety device (including grills and blades) must be reinstalled or remounted as
previously installed.
Use soft damp cloth then wipe with dry cloth. Do not use harmful cleaners. Do not
bend the blades.
Wash guards and blades with water and a soft brush. Avoid harsh chemical
cleaners.
DO NOT IMMERSE MOTOR IN WATER.
Allow fan to dry completely before use.
MODEL WATTS(W) AMPS(A) Volts N.W. G.W.
LOW MED HI LOW MED HI V kg kg
HVP-30E
172 195 225 1.52 1.68 1.91 120 26 31.5
*These are approximate measures.
If you should have any further questions, please contact CUSTOMER SERVICE at
56 64 14 00.