FCI ASF-0009 User manual

P a g e | 1
GooseNeck Wall-Mount
Automatic Faucet
ASF-0009
Installation Manual
Quality Guarantee
*Thank you for choosing the automatic wall mount faucet. Please read the
instruction carefully before installation. This manual is for your reference
only.

P a g e | 2
Features
•Hands free sensor operation.
•Strategic location of sensor at tip of spout
for instant response time.
•Easy installation and low-cost
maintenance

P a g e | 3
Specifications
Power
6V (4 x Alkaline AA) or 120 V
50 Hz AC
Sensing Range
60 - 75 cm
Water Pressure
0.05 –0.8 MPa
Water
Temperature
0.1 –60 oC
Response Time
0.5 Secs
Plumbing
Fittings
G ½”, G3/8”, 9/16-24

P a g e | 4
Before Installation
•Observe all local and plumbing codes.
•Check the cold and/or hot water supply
pressure.
oThe recommended working
pressure range is 20 psi - 70 psi
(138 kPa - 551 kPa).If the supply
pressure is higher than 80 psi (551
kPa), reduce to within
recommended range by using a
pressure reducing valve (sold
separatery).
•Check the temperature of the water
supply.
oThe recommended supply
temperature range is 39°F - 104°F
(4°C - 40°C) Never use steam as a
hot water supply.
•Flush all water lines prior to installation.
Other precautions before you begin:
•Pay special attention so that the sensor
surface is not flawed or scratched during
the installation process.
•Make sure that all pipework, stop valves,
and connection lines are installed
according to local codes.

P a g e | 5
•Do not place other devices that use an
inverter or infrared sensor near the faucet,
as this may cause the faucet to
malfunction.
•Optional: For hot / cold water installation,
mixing valve MV-0001 and two ½’ F to 3/8
F FH-0001FF flex hoses are required.
Tools You will Need
•Adjustable wrench
•Power drill
•Phillips screwdriver

P a g e | 6
Operations
No adjustments are required for most settings.
Eeffective sensor default range is 65 cm. The
factory setting should be satisfactory for most
installations.
Place your hands under the faucet. The water will
flow for 5 secs within the sensor’s range. When
hands are removed water flow should stop.

P a g e | 7
Part List
1
Aerator
6
Screw (x2)
2
Faucet body
7
Connector (4 pin)
3
Water inlet
8
Sensor
4
Nut
9
Set screw
5
Sensor cover
10
Control box

P a g e | 8
Construction /
Installation Diagram
Installation steps
1. Driil one 22 mm & 18.5 mm diameter hole
onto the mounting wall
2. Remove the nut from the faucet. Assemble
the faucet onto the two drilled holes. Route
the cable thorugh the 18.5 mm hole and
secure the nut onto the faucet to position

P a g e | 9
3. For Battery Operated;
Mount the control box below the couter top as
shown in the diagram on the right. For ASF-
0009A (AC option) and mixing valve

P a g e | 10
4. Connect both the 70 cm flex hose and the
cable connector from the control box onto
faucet

P a g e | 11
Setting Sensor Range
•Place and hold the black magnet bar in
front of the sensor for 3 seconds unitl the
LED sensor starts to blink.
•Remove magnet from the sensor and
place hand / object at the desired range
(distance) for 5 secs.
•Remove hand / object after 3 blinks. The
range is now set

P a g e | 12
Battery Replacement
Replace battery when RED LED indicator flashes
rapidly or when flusher stops functioning.
i. Turnoff the water supply.
ii. Disconnect the battery box from the
sensor.
iii. Remove the battery holder
iv. Using a Philips screw driver remove
the battery cover and the batteries.
v. Replace 4 AA batteries
vi. Place back the battery cover and
fasten the four Phillip screws to
secure the cover.
vii. Connect the battery holder to the
sensor and place the battery holder
inside the junction box.
viii.Place back the battery holder onto
the battery bracket.

P a g e | 13
Troubleshooting
1. LED indicator in the sensor is red.
i. Battery power is low. Install four (4)
new AA sized batteries.
2. Faucet does not function.
i. Batteries not installed correctly or
depleted. Install four (4) new AA
sized batteries.
ii. Battery power cable not connected.
Connect the cable securely.
3. Sensor is activiated but the faucet does
not delvier water.
i. Faucet has initiated its adaptive
sensing calibration. Wait 45 secs.
4. Faucet delviers only a few flow or dribble
when the sensor is activated.
i. Water supply valve is partially
closed. Open the the supply valve
completely.
ii. Aerator or spray head is clogged.
Remove, clean and reinsert.
iii. Remove & clean supply valve filter.

P a g e | 14
Care & Cleaning
DO NOT USE abrasive or chemical cleaners
(including chlorine bleach) to clean faucet that
may dull the luster and attack the chrome or
special decorative finishes. Use ONLY mild soap
and water, then wipe dry with clean cloth or
towel. While cleaning the bathroom tile, protect
the faucet from any splattering of cleaner. Acids
and cleaning fluids will discolor or remove
chrome plating.

P a g e | 15
Resources
Warranty Information
For information on product
warranty, visit our resource page
through the QR code.
Alternatively, you can visit our
warranty claims page at
https://faucetscanada.ca//warranty
-claim/
For Installation guides, visit our
resource page through the QR
code
Alternatively, you can visit our
resource page at
https://faucetscanada.ca/resources/
To view more products from
Faucets Canada, visit our shop
page through the QR code.
Alternatively, you can visit our shop
page at
https://faucetscanada.ca/shop/

P a g e | 16
About us
Here at FCi, our main goal is to break the eco-
innovation boundary and provide customers with
fixtures that save water and deliver reliable
sources of sanitation every time.
As Canada’s favourite automatic faucet brand,
we are proud to say we deliver quality touchless
fixtures that perform beyond expectations and
exceed design standards.
To learn more about Faucets Canada, please visit our website at
FacucetsCanada.ca
Table of contents
Popular Kitchen & Bath Fixture manuals by other brands

Sloan
Sloan BASYS EFX-8XX SERIES Repair Parts and Maintenance Guide

Spectrum Brands
Spectrum Brands Pfister Karci LF-048-KA Quick installation guide

Hans Grohe
Hans Grohe Croma 100 Vario / Unica'C Set Instructions for use/assembly instructions

Kraus
Kraus Oletto KTF-3104 installation manual

Symmons
Symmons DURO ACTIVESENSE S6360B Installation and maintenance guide

American Standard
American Standard Fairacres 4005310 owner's manual