manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Sloan
  6. •
  7. Kitchen & Bath Fixture
  8. •
  9. Sloan BASYS EFX-8XX SERIES Use and care manual

Sloan BASYS EFX-8XX SERIES Use and care manual

Repair Parts and Maintenance Guide
142
The information contained in this document is subject to change without notice.
BASYS®
Infrared Sensor Activated
NOTE: Turning off water is not necessary, due to integrated automatic stop
valve.
Rotate solenoid assembly counter-
clockwise through a 45º angle.
Pull solenoid caddy from faucet.
NOTE: Strainer can be removed,
cleaned and replaced at this time.
Insert new solenoid caddy at a 45°
angle.
Rotate solenoid caddy clockwise to
align with arrow, locking the unit
and opening water path.
Remove crown by loosening hex
screw located on underside of spout
and slide crown down and lift off.
NOTE: Screw is captive within
faucet body and will not fall out.
REPLACING THE SOLENOID STRAINER (FILTER)
Slide on crown and secure.
NOTE: Turning off water is not necessary, due to integrated automatic stop
valve.
Retrieve spray removal tool located
near the spray insert.
Insert spray removal tool into spray
slot by sliding hook end of key
between faucet spout and insert.
Pull insert out of faucet once
hooked.
Remove crown by loosening hex
screw located on underside of spout
and slide crown down and lift off.
NOTE: Screw is captive within
faucet body and will not fall out.
REPLACE SPRAY INSERT
UNLOCK
LOCK
Install new insert.
NOTE: If changing to a different
flow rate solenoid caddy must
be changed in conjunction.
Return spray removal tool to storage
location.
NOTE: This can only be done once
spray head is installed. This will
lock the spray head in place.
NOTE: If spray head is inserted
incorrectly – key will not lock in
properly. Turn faucet on to push
insert out and re-install.
Slide on crown and secure.
UNLOCK
LOCK
Faucets and
Soap Dispensers
Repair Parts and Maintenance Guide
143 The information contained in this document is subject to change without notice.
BASYS®
Infrared Sensor Activated
PARTS LIST—BASYS FAUCETS
Item
No. Code No. Part No. Description
1. —— Wall Mount Faucet Assembly
2. 3324104 EFX-1002-A 0.5 gpm/1.9 Lpm Multi-Lam Spray Head (includes
insert, o-ring, 2.5 mm allen key, and removal tool)
3324103 EFX-1001-A 1.5 gpm/5.7 Lpm Aerated Stream Insert (includes
insert, o-ring, 2.5 mm allen key, and removal tool)
3324102 EFX-1000-A 1.5 gpm/5.7 Lpm Laminar Stream Insert (includes
insert, o-ring, 2.5 mm allen key, and removal tool)
3. 3324162 EFX-1011-A 0.5 gpm/1.9 Lpm Solenoid Valve Caddy Assembly
– Wall (Green)‡
3324163 EFX-1012-A 1.5 gpm/5.7 Lpm Solenoid Valve Caddy Assembly
– Wall (Blue) ‡
4. 0324019 EFX-19 Strainer (Filter)
5. —EFX-1013-A Mounting Assembly
6A. 3324160 EFX-1009-A Bowed Crown Assembly
6B. 3324138 EFX-1010-A Solar Crown Assembly
6C. 3324139 EFX-1018-A Solar Crown with LCD Assembly
7. —— CR-P2 Lithium Battery
8. 3326009 MIX-60-A Mechanical, Below Deck Mixing Valve
9. 0326045 MIX-135-A Thermostatic, Below Deck Mixing Valve
10. 3365461 ETF-617-A Bak-Chek Tee Assembly
11. 0335023 EAF-23-A Splitter
12. 0335024 EAF-24-A 11-13/16” (300 mm) Extension Cable
0335025 EAF-25-A 47-1/4” (1200 mm) Extension Cable
0335015 EAF-17-A 126” (3200 mm) Extension Cable
13. 0335009 EAF-11 Plug-in Voltage Adapter (US)
0335041 EAF-41 Plug-in Voltage Adapter (EU)
0335039 EAF-39 Plug-in Voltage Adapter (UK)
0335037 EAF-37 Box Type Voltage Adapter
14. 3324165 EFX-1014-A Wall Flange
15. —— Purge Tool
NOTE: If changing ow rate caddy and spray insert must be changed in conjunction.
† Single Supply faucets include Bak-Chek®
— in Item No. column = Not shown in illustration
— in Code No. and Part No. column = Not sold separately
‡ Old style / T-shaped contact.
New style / Plug contact
6A 6B 6C
14
7
4
1
5
8
3
9
10
13
15
12
11
2
Electrical Connection for up to Six (6) Faucets Using One (1) Adapter
EFX-8XX SERIES
NOTE: HARDWIRE FAUCETS SUPPLIED WITH ONE (1) 47” (1.2 m) EXTENSION CABLE.
NOTE: EXTENSION CABLES AVAILABLE SEPARATELY.
NOTE: USE ONLY SLOAN SUPPLIED POLARIZED AND KEYED CABLE ASSEMBLIES.
IMPORTANT: CUTTING AND SPLICING WIRES WILL VOID WARRANTY.
SPLITTER AND
EXTENSION CABLE
6 VDC
PLUG-IN
ADAPTER
CABLE
BEHIND
THE WALL
CABLE
BEHIND
THE WALL
CABLE
BEHIND
THE WALL
SPLITTER AND
EXTENSION CABLE
TO ADDITIONAL
FAUCETS (6 MAX)
Faucets and
Soap Dispensers
372626_Master_Book_ccg.indd 141 9/18/17 7:53 AM
Repair Parts and Maintenance Guide
144
The information contained in this document is subject to change without notice.
BASYS®
Infrared Sensor Activated
1. Red LED in spout does not blink 2 seconds after battery
installation.
A. Battery placement incorrect or batteries have been discharged.
B. Ensure batteries are installed properly. Check the orientation of each
battery matches the positive (+) and negative (–) symbols shown on
the battery compartment.
2. Faucet DOES NOT function.
A. Adhesive packaging label afxed over sensor eye.
B. Remove adhesive label from sensor eye.
3. Faucet delivers water in an uncontrolled manner.
A. Faucet is not working properly.
B. Clean sensor window; if problem persists contact Sloan Tech Support.
4. Faucet DOES NOT deliver any water when sensor is activated.
INDICATOR: Solenoid valve produces an audible “CLICK”.
A. Water supply stop(s) closed.
Open water supply stop(s).
B. Strainer is clogged.
Remove, clean, and reinstall strainer. Replace strainer, if needed (refer
to page 131).
5. Solenoid valve DOES NOT produce an audible “CLICK”.
A. Batteries low (battery powered models).
Replace batteries (refer to battery replacement on page 130).
B. Power failure (hardwire models). Check power supply.
6. Faucet delivers only a slow flow or dribble when sensor is
activated.
A. Water supply stop(s) are partially closed. Completely open water
supply stop(s).
7. Faucet DOES NOT stop delivering water or continues to drip after
user is no longer detected.
A. Faucet is not working properly.
B. Clean sensor window; if problem persists contact Sloan Tech Support
(see below).
8. LED indicator blinks RED when faucet is in use.
A. Batteries low (battery powered models).
B. Replace batteries (refer to battery replacement on page 132).
9. The water temperature is too hot or too cold on a faucet
connected to hot and cold water supply lines.
A. Supply stops are not adjusted properly. Adjust supply stops.
B. For models with integral side mixing valve–Mixing valve is set
improperly for the water temperature desired. Rotate mixing valve
handle clockwise to decrease water temperature or counterclockwise
to increase water temperature.
C. Inadequate hot water supply. Adjust supply stops.
CARE AND CLEANING
DO NOT USE abrasive or chemical cleaners
(including chlorine bleach) to clean faucets that
may dull the luster and attack the chrome or
special decorative nishes. Use ONLY mild soap
and water, then wipe dry with clean cloth or towel.
While cleaning the bathroom sink, protect the
faucet from any splattering of cleaner. Acids
and cleaning uids will discolor or remove
chrome plating.
When assistance is required, please contact
Sloan Technical Support at: 1-888-SLOAN-14 (1-888-756-2614).
TROUBLESHOOTING GUIDE
Faucets and
Soap Dispensers
Repair Parts and Maintenance Guide
145 The information contained in this document is subject to change without notice.
2x +
1x 5 sec
1x
2x
3x
4x
6x - Factory Setting
7x
8x
5x
2x +
1x 5 sec
2x +
1x 5 sec
1x
2x
3x
4x
6x - Factory Setting
7x
8x
5x
2x +
1x 5 sec
Wait, until LED ashes GREEN.
2x +
1x 5 sec
1x
2x
3x
4x
6x - Factory Setting
7x
8x
5x
2x +
1x 5 sec
2x +
1x 5 sec
1x
2x
3x
4x
6x - Factory Setting
7x
8x
5x
2x +
1x 5 sec
BASYS®
Infrared Sensor Activated
Factory setting is appropriate for the majority of applications and
should not require resetting unless under extreme situations: high
reflection or low light.
IR Activation (see previous page).To enter programming mode place nger
on IR clic for 2 times then remove. Light on side of crown should blink to
indicate programming mode.
SENSOR RANGE ADJUSTMENT BATTERY REPLACEMENT
NOTE: Replace battery when LED1 indicator flashes RED each time
faucet is in use or when faucet stops functioning. LED1 is identified
by the battery symbol.
NOTE: Turning off water is not necessary.
Remove crown by loosening 2 hex screws located on
underside of spout and slide crown down and lift off.
NOTE: Screw is captive within faucet body and will
NOT fall out.
UNLOCK
LOCK
LOCK
RED LED
UNLOCK
UNLOCK
LOCK
LOCK
RED LED
UNLOCK
UNLOCK
LOCK
LOCK
RED LED
UNLOCK
Cover IR clic until LED ashes RED 4 times - hold IR clic on until LED
ashes 1 time to 8 times from minimum to maximum range. See diagram
below. Release when requested range is reached.
Remove red cover over the battery. Remove battery holder from the faucet
body. Replace battery in the holder. Holder drops into the faucet body.
Place the red cover over the battery.
Slide on crown and secure in 2 places.
Faucets and
Soap Dispensers
372626_Master_Book_ccg.indd 142 9/18/17 7:53 AM
Repair Parts and Maintenance Guide
144
The information contained in this document is subject to change without notice.
BASYS®
Infrared Sensor Activated
1. Red LED in spout does not blink 2 seconds after battery
installation.
A. Battery placement incorrect or batteries have been discharged.
B. Ensure batteries are installed properly. Check the orientation of each
battery matches the positive (+) and negative (–) symbols shown on
the battery compartment.
2. Faucet DOES NOT function.
A. Adhesive packaging label afxed over sensor eye.
B. Remove adhesive label from sensor eye.
3. Faucet delivers water in an uncontrolled manner.
A. Faucet is not working properly.
B. Clean sensor window; if problem persists contact Sloan Tech Support.
4. Faucet DOES NOT deliver any water when sensor is activated.
INDICATOR: Solenoid valve produces an audible “CLICK”.
A. Water supply stop(s) closed.
Open water supply stop(s).
B. Strainer is clogged.
Remove, clean, and reinstall strainer. Replace strainer, if needed (refer
to page 131).
5. Solenoid valve DOES NOT produce an audible “CLICK”.
A. Batteries low (battery powered models).
Replace batteries (refer to battery replacement on page 130).
B. Power failure (hardwire models). Check power supply.
6. Faucet delivers only a slow flow or dribble when sensor is
activated.
A. Water supply stop(s) are partially closed. Completely open water
supply stop(s).
7. Faucet DOES NOT stop delivering water or continues to drip after
user is no longer detected.
A. Faucet is not working properly.
B. Clean sensor window; if problem persists contact Sloan Tech Support
(see below).
8. LED indicator blinks RED when faucet is in use.
A. Batteries low (battery powered models).
B. Replace batteries (refer to battery replacement on page 132).
9. The water temperature is too hot or too cold on a faucet
connected to hot and cold water supply lines.
A. Supply stops are not adjusted properly. Adjust supply stops.
B. For models with integral side mixing valve–Mixing valve is set
improperly for the water temperature desired. Rotate mixing valve
handle clockwise to decrease water temperature or counterclockwise
to increase water temperature.
C. Inadequate hot water supply. Adjust supply stops.
CARE AND CLEANING
DO NOT USE abrasive or chemical cleaners
(including chlorine bleach) to clean faucets that
may dull the luster and attack the chrome or
special decorative nishes. Use ONLY mild soap
and water, then wipe dry with clean cloth or towel.
While cleaning the bathroom sink, protect the
faucet from any splattering of cleaner. Acids
and cleaning uids will discolor or remove
chrome plating.
When assistance is required, please contact
Sloan Technical Support at: 1-888-SLOAN-14 (1-888-756-2614).
TROUBLESHOOTING GUIDE
Faucets and
Soap Dispensers
Repair Parts and Maintenance Guide
145 The information contained in this document is subject to change without notice.
2x +
1x 5 sec
1x
2x
3x
4x
6x - Factory Setting
7x
8x
5x
2x +
1x 5 sec
2x +
1x 5 sec
1x
2x
3x
4x
6x - Factory Setting
7x
8x
5x
2x +
1x 5 sec
Wait, until LED ashes GREEN.
2x +
1x 5 sec
1x
2x
3x
4x
6x - Factory Setting
7x
8x
5x
2x +
1x 5 sec
2x +
1x 5 sec
1x
2x
3x
4x
6x - Factory Setting
7x
8x
5x
2x +
1x 5 sec
BASYS®
Infrared Sensor Activated
Factory setting is appropriate for the majority of applications and
should not require resetting unless under extreme situations: high
reflection or low light.
IR Activation (see previous page).To enter programming mode place nger
on IR clic for 2 times then remove. Light on side of crown should blink to
indicate programming mode.
SENSOR RANGE ADJUSTMENT BATTERY REPLACEMENT
NOTE: Replace battery when LED1 indicator flashes RED each time
faucet is in use or when faucet stops functioning. LED1 is identified
by the battery symbol.
NOTE: Turning off water is not necessary.
Remove crown by loosening 2 hex screws located on
underside of spout and slide crown down and lift off.
NOTE: Screw is captive within faucet body and will
NOT fall out.
UNLOCK
LOCK
LOCK
RED LED
UNLOCK
UNLOCK
LOCK
LOCK
RED LED
UNLOCK
UNLOCK
LOCK
LOCK
RED LED
UNLOCK
Cover IR clic until LED ashes RED 4 times - hold IR clic on until LED
ashes 1 time to 8 times from minimum to maximum range. See diagram
below. Release when requested range is reached.
Remove red cover over the battery. Remove battery holder from the faucet
body. Replace battery in the holder. Holder drops into the faucet body.
Place the red cover over the battery.
Slide on crown and secure in 2 places.
Faucets and
Soap Dispensers
372626_Master_Book_ccg.indd 143 9/18/17 7:53 AM
Repair Parts and Maintenance Guide
146
The information contained in this document is subject to change without notice.
BASYS®
Infrared Sensor Activated
As the user’s hands enter the beam’s effective range, the beam is reected
back into the sensor receiver and activates the solenoid valve allowing water
to ow from the faucet. Water will ow until the hands are removed or until
the faucet reaches its automatic time out limit setting.
OPERATION
This feature will operate the faucet
every 12 or 24 hours since last
use, if not used to prevent stagnant
water conditions.
Default purge duration is two
minutes.
Consult factory regarding other
timing options.
IR activation (see above). Cover IR
clic approximately 24 sec. (ignore
LED indications during this period).
Release when requested program
is reached. (See diagram to right).
Programming mode will time out
after 2 minutes if no changes are
made.
12/24 LINE PURGE FEATURE
Activate 12HR
Deactivate
Activate 24HR
1x 24 sec
...1x
...2x
...3x
+ ...
Activate 12HR
Deactivate
Activate 24HR
1x 24 sec
...1x
...2x
...3x
+ ...
Steps to Default IR
Function Activate Function Setting Clic
IR Activation Cover IR clic approximately for 2 sec. –– ––
until LED will ash GREEN 1x - then remove
nger from IR clic (Active for 5 sec.)
Cleaning IR activation; Cover IR clic 2x - conrmation 2 min. ––
Mode of the function is active by a couple ashes
by the LED; to return to normal operation cover
IR clic 1x or the faucet will automatically return
to normal function after 2 min.
12/24 Line See below. Off Off
Purge 12HR
Feature 24HR
Sensor See next page. 6 1-8
Range
Adjustment
Reset IR activation; Cover IR clic 2x; LED will ash 5x Manually ––
Electronics Cover IR clic 1x for 5 sec. until LED
ashes 4x, then remove nger from IR clic
Wait for 20 sec.
(After 10 sec. water will ow for 6 sec.
and automatically adjust to environment)
Security Off After 90 seconds (max) of hand and/or object On ––
within sensor appears permanent, waterow
will stop and will remeasure environment
Please contact factory for more extensive programming options.
Faucets and
Soap Dispensers
Repair Parts and Maintenance Guide
147 The information contained in this document is subject to change without notice.
BASYS®
Infrared Sensor Activated
Remove crown by loosening hex
screw located on underside of spout
and slide crown down and lift off.
NOTE: Screw is captive within
faucet body and will NOT fall out.
UPGRADE FAUCET FUNCTIONALITY
LED DISPLAY DIAGNOSTIC CODES
Place new crown on faucet by sliding
onto spout and tightening hex screw
on underside of spout.
NOTE: All electronics are fully
encapsulated in the crown
and thus protected from the
environment and easy to replace
or upgrade.
RED GREEN
RED GREEN
RED
RED
RED
RED
RED
GREEN
GREEN
GREEN
RED
RED
RED
RED LED1
GREEN LED2
RED LED3
Function LED1 LED2 LED3 Description 1 Description 2
Start Up Boot LED1 and LED2 alternate blinking Fast Toggle
Battery Check after Start Up LED1 on for 2 sec, if battery greater than 3.5V
Line Power Check after Start Up LED3 on for 2 sec, if line power greater than 3.5V
IR Adjust Process LED1 blinking while IR adjusts Few seconds
IR Adjust IR LED2 on for 2 sec, if adjustment OK
Battery Low LED1 blinks 3x, if battery is less than warning level Only while in detection mode
Battery Empty LED1 double ashes 3x, if battery is
less than empty level Only while in detection mode
Valve Error
LED3 double ashes 3x, if valve
current error; ash after the 3rd error,
off after the 3rd good operation
Flashes after the 3rd error, off
after the 3rd good operation
IR Activation LED2 on for 2 sec, if IR-click has been activated After 5 sec. automatically back to
operating mode
Cleaning Mode LED1 4-in-1 ash, if cleaning mode is activated During “Cleaning Mode” is activated
Permanent 4-in-1 ashes
COLOR LEDs BLINKING
COLOR LEDs ON
UNLOCK
LOCK
UNLOCK
LOCK
Faucets and
Soap Dispensers
372626_Master_Book_ccg.indd 144 9/18/17 7:53 AM
Repair Parts and Maintenance Guide
146
The information contained in this document is subject to change without notice.
BASYS®
Infrared Sensor Activated
As the user’s hands enter the beam’s effective range, the beam is reected
back into the sensor receiver and activates the solenoid valve allowing water
to ow from the faucet. Water will ow until the hands are removed or until
the faucet reaches its automatic time out limit setting.
OPERATION
This feature will operate the faucet
every 12 or 24 hours since last
use, if not used to prevent stagnant
water conditions.
Default purge duration is two
minutes.
Consult factory regarding other
timing options.
IR activation (see above). Cover IR
clic approximately 24 sec. (ignore
LED indications during this period).
Release when requested program
is reached. (See diagram to right).
Programming mode will time out
after 2 minutes if no changes are
made.
12/24 LINE PURGE FEATURE
Activate 12HR
Deactivate
Activate 24HR
1x 24 sec
...1x
...2x
...3x
+ ...
Activate 12HR
Deactivate
Activate 24HR
1x 24 sec
...1x
...2x
...3x
+ ...
Steps to Default IR
Function Activate Function Setting Clic
IR Activation Cover IR clic approximately for 2 sec. –– ––
until LED will ash GREEN 1x - then remove
nger from IR clic (Active for 5 sec.)
Cleaning IR activation; Cover IR clic 2x - conrmation 2 min. ––
Mode of the function is active by a couple ashes
by the LED; to return to normal operation cover
IR clic 1x or the faucet will automatically return
to normal function after 2 min.
12/24 Line See below. Off Off
Purge 12HR
Feature 24HR
Sensor See next page. 6 1-8
Range
Adjustment
Reset IR activation; Cover IR clic 2x; LED will ash 5x Manually ––
Electronics Cover IR clic 1x for 5 sec. until LED
ashes 4x, then remove nger from IR clic
Wait for 20 sec.
(After 10 sec. water will ow for 6 sec.
and automatically adjust to environment)
Security Off After 90 seconds (max) of hand and/or object On ––
within sensor appears permanent, waterow
will stop and will remeasure environment
Please contact factory for more extensive programming options.
Faucets and
Soap Dispensers
Repair Parts and Maintenance Guide
147 The information contained in this document is subject to change without notice.
BASYS®
Infrared Sensor Activated
Remove crown by loosening hex
screw located on underside of spout
and slide crown down and lift off.
NOTE: Screw is captive within
faucet body and will NOT fall out.
UPGRADE FAUCET FUNCTIONALITY
LED DISPLAY DIAGNOSTIC CODES
Place new crown on faucet by sliding
onto spout and tightening hex screw
on underside of spout.
NOTE: All electronics are fully
encapsulated in the crown
and thus protected from the
environment and easy to replace
or upgrade.
RED GREEN
RED GREEN
RED
RED
RED
RED
RED
GREEN
GREEN
GREEN
RED
RED
RED
RED LED1
GREEN LED2
RED LED3
Function LED1 LED2 LED3 Description 1 Description 2
Start Up Boot LED1 and LED2 alternate blinking Fast Toggle
Battery Check after Start Up LED1 on for 2 sec, if battery greater than 3.5V
Line Power Check after Start Up LED3 on for 2 sec, if line power greater than 3.5V
IR Adjust Process LED1 blinking while IR adjusts Few seconds
IR Adjust IR LED2 on for 2 sec, if adjustment OK
Battery Low LED1 blinks 3x, if battery is less than warning level Only while in detection mode
Battery Empty LED1 double ashes 3x, if battery is
less than empty level Only while in detection mode
Valve Error
LED3 double ashes 3x, if valve
current error; ash after the 3rd error,
off after the 3rd good operation
Flashes after the 3rd error, off
after the 3rd good operation
IR Activation LED2 on for 2 sec, if IR-click has been activated After 5 sec. automatically back to
operating mode
Cleaning Mode LED1 4-in-1 ash, if cleaning mode is activated During “Cleaning Mode” is activated
Permanent 4-in-1 ashes
COLOR LEDs BLINKING
COLOR LEDs ON
UNLOCK
LOCK
UNLOCK
LOCK
Faucets and
Soap Dispensers
372626_Master_Book_ccg.indd 145 9/18/17 7:53 AM
Repair Parts and Maintenance Guide
148
The information contained in this document is subject to change without notice.
BASYS®
Infrared Sensor Activated
NOTE: Turning off water is not necessary, due to integrated automatic stop
valve.
Rotate solenoid assembly counter-
clockwise through a 45º angle.
Pull solenoid caddy from faucet.
NOTE: Strainer can be removed,
cleaned and replaced at this time.
Insert new solenoid caddy at a
45° angle.
Remove crown by loosening hex
screw located on underside of spout
and slide crown down and lift off.
NOTE: Screw is captive within
faucet body and will NOT fall out.
REPLACING THE SOLENOID STRAINER (FILTER)
UNLOCK
LOCK
UNLOCK
LOCK
UNLOCK
LOCK
UNLOCK
LOCK
Rotate solenoid caddy clockwise to
align with arrow, locking the unit
and opening water path.
Slide on crown and secure in
2 places.
NOTE: Turning off water is not necessary, due to integrated automatic stop
valve.
Retrieve spray removal tool located
near the spray insert.
Insert spray removal tool into spray
slot by sliding hook end of key
between faucet spout and insert.
Pull insert out of faucet once
hooked.
Remove crown by loosening hex
screw located on underside of spout
and slide crown down and lift off.
NOTE: Screw is captive within
faucet body and will NOT fall out.
REPLACE SPRAY INSERT
Install new insert.
NOTE: If changing to a different
ow rate solenoid caddy must be
changed in conjunction.
Return spray removal tool to storage
location.
NOTE: This can only be done once
spray head is installed. This will lock
the spray head in place.
NOTE: If spray head is inserted
incorrectly – key will not lock in
properly. Turn faucet on to push
insert out and re-install.
Slide on crown and secure.
Faucets and
Soap Dispensers
Repair Parts and Maintenance Guide
149 The information contained in this document is subject to change without notice.
BASYS®
Capacitance Sensing Activated
PARTS LIST—BASYS FAUCETS
Item
No. Code No. Part No. Description
1. 0324002 EFX-2 Standard Crown
2. 0324036 EFX-36 Control Module Mounting Kit
3. 3324113 EFX-8 Battery Pack
4. 3324114 EFX-13-A Solenoid Valve Caddy 0.5 gpm (1.9 Lpm)
3324115 EFX-14-A Solenoid Valve Caddy 1.5 gpm (5.7 Lpm)
5. 0324019 EFX-19 Filter / Strainers
6. 3324105 EFX-1003-A Control Module Assembly – 0.5 gpm (1.9 Lpm)
3324106 EFX-1004-A Control Module Assembly with Turbine –
0.5 gpm (1.9 Lpm)
3324107 EFX-1005-A Control Module Assembly – 1.5 gpm (5.7 Lpm)
3324108 EFX-1006-A Control Module Assembly with Turbine –
1.5 gpm (5.7 Lpm)
7. 0335009 EAF-11 Plug-in Voltage Adapter (US)
0335041 EAF-41 Plug-in Voltage Adapter (EU)
0335039 EAF-39 Plug-in Voltage Adapter (UK)
0335037 EAF-37 Box Type Voltage Adapter
8A. 0335000 EAF-1 Faucet Spout Mounting Kit (Pedestal)
8B. 0324021 EFX-21-A Faucet Spout Mounting Kit (Integrated Base)
9. 3324100 EFX-20-A 4-inch (102 mm) Centerset Base Plate Kit
10. 3324101 EFX-26-A 8-inch (203 mm) Centerset Base Plate Kit
11. 3326009 MIX-60-A Below Deck Mechanical Mixing Valve
12. 0326045 MIX-135-A Below Deck Thermostatic Mixing Valve
13. 0324033 ETF-617-A Bak-Chek®Tee
14. 0324034 EFX-33 Inlet Hose Fitting
15. 3324102 EFX-34 Flexible Supply Hose 18” (45 mm)
16. 3324104 EFX-1002-A 0.5 gpm (1.9 Lpm) Multi-Lam Spray Insert,
includes: insert, o-ring, insert removal tool, and
hex key
3324103 EFX-1001-A 1.5 gpm (5.7 Lpm) Aerated Stream Insert
includes: insert, o-ring, insert removal tool, and
hex key
3324102 EFX-1000-A 1.5 gpm (5.7 Lpm) Laminar Stream Insert
includes: insert, o-ring, insert removal tool, and
hex key
17. 0335023 EAF-23-A Splitter
18. 0335024 EAF-24-A 11-13/16” (300 mm) Extension Cable
0335025 EFX-25-A 47-1/4” (1200 mm) Extension Cable
0335015 EFX-17-A 126” (3200 mm) Extension Cable
NOTE: If changing ow rate, caddy and spray insert must be changed in conjunction.
Manufactured by Sloan Valve Company under one or more of the following U.S. Patents: 7,690, 623; 7,069,941;
6,619,320.
— in Item No. column = Not shown in illustration
— in Code No. and Part No. column = Not sold separately
1
8B
2
6
3
14 15
4
5
11 7
18
16
12
13
8A
9
10
17
EFX-3XX EFX-6XX
Electrical Connection for up to Six (6) Faucets Using One (1) Adapter
DAISY CHAIN
ELECTRICAL CABLE
DAISY CHAIN
ELECTRICAL
CABLE
TO ADDITIONAL
FAUCETS
(6 MAX.)
ADAPTER
Not for installation on a metal sink or
deck (i.e. stainless steel or cast metal).
IMPORTANT
Faucets and
Soap Dispensers
372626_Master_Book_ccg.indd 146 9/18/17 7:53 AM
Repair Parts and Maintenance Guide
150
The information contained in this document is subject to change without notice.
BASYS®
Infrared Sensor Activated
1. RED LED in spout DOES NOT blink 2 seconds after battery
installation.
A. Battery placement incorrect or batteries have been discharged.
Ensure batteries are installed properly. Check the orientation of each
battery matches the positive (+) and negative (–) symbols shown on
the battery compartment.
2. Faucet DOES NOT function.
A. Adhesive packaging label afxed over sensor eye.
Remove adhesive label from sensor eye.
3. Faucet delivers water in an uncontrolled manner.
A. Faucet is not working properly.
B. Clean sensor window; if problem persists contact Sloan Technical
Support (see below).
4. Faucet DOES NOT deliver any water when sensor is activated.
INDICATOR: Solenoid valve produces an audible “CLICK”.
A. Water supply stop(s) closed.
Open water supply stop(s).
B. Strainer is clogged.
Remove, clean, and reinstall strainer. Replace strainer (lter), if needed
(refer to page 139).
INDICATOR: Solenoid valve DOES NOT produce an audible “CLICK”.
A. Batteries low (battery-powered models).
Replace batteries (refer to battery replacement on page 136).
B. Power failure (hardwire models).
Check power supply.
5. Faucet delivers only a slow flow or dribble when sensor is
activated.
A. Water supply stop(s) are partially closed.
Completely open water supply stop(s).
6. Faucet DOES NOT stop delivering water or continues to drip after
user is no longer detected.
A. Faucet is not working properly.
Clean sensor window; if problem persists contact Sloan Technical
Support (see below).
7. LED indicator blinks RED when faucet is in use.
A. Batteries low (battery-powered models).
Replace batteries (refer to battery replacement on page 136).
8. The water temperature is too hot or too cold on a faucet
connected to hot and cold water supply lines.
A. Supply stops are not adjusted properly.
Adjust supply stops.
B. For models with integral side mixing valve–mixing valve is set
improperly for the water temperature desired.
Rotate mixing valve handle clockwise to decrease water temperature or
counterclockwise to increase water temperature.
C. Inadequate hot water supply.
Adjust supply stops.
CARE AND CLEANING
DO NOT USE abrasive or chemical cleaners (including chlorine bleach) to
clean faucets that may dull the luster and attack
the chrome or special decorative nishes. Use
ONLY mild soap and water, then wipe dry with
clean cloth or towel.
While cleaning the bathroom sink, protect the
faucet from any splattering of cleaner. Acids and
cleaning uids will discolor or remove chrome
plating.
When assistance is required, please contact
Sloan Technical Support at: 1-888-SLOAN-14
(1-888-756-2614).
TROUBLESHOOTING GUIDE
Faucets and
Soap Dispensers
Repair Parts and Maintenance Guide
151 The information contained in this document is subject to change without notice.
BASYS®
Capacitance Sensing Activated
REPLACE FILTER
Disconnect solenoid wire from
control module.
Turn solenoid caddycounterclockwise
lining up arrows on control module
and solenoid caddy assembly.
Remove solenoid caddy assembly
from control module by pulling
straight out.
Remove lter from solenoid caddy
assembly.
Remove new lter from control
module cover.
Snap new lter onto solenoid
caddy assembly.
Insert solenoid caddy assembly into
control module lining up arrows.
Turn solenoid caddy assembly
clockwise 45º.
Reconnect solenoid caddy wire to
control module.
Faucets and
Soap Dispensers
372626_Master_Book_ccg.indd 148 9/18/17 7:54 AM

Other Sloan Kitchen & Bath Fixture manuals

Sloan G2 Optima Plus Operating instructions

Sloan

Sloan G2 Optima Plus Operating instructions

Sloan MH-2000 User manual

Sloan

Sloan MH-2000 User manual

Sloan Optima ETF-660 User manual

Sloan

Sloan Optima ETF-660 User manual

Sloan OPTIMA I.Q. EAF-100 Series User manual

Sloan

Sloan OPTIMA I.Q. EAF-100 Series User manual

Sloan Optima EAF-275 Use and care manual

Sloan

Sloan Optima EAF-275 Use and care manual

Sloan WES-7000 User manual

Sloan

Sloan WES-7000 User manual

Sloan EAF-275 Series Operating manual

Sloan

Sloan EAF-275 Series Operating manual

Popular Kitchen & Bath Fixture manuals by other brands

Pressalit R2020 Mounting instruction

Pressalit

Pressalit R2020 Mounting instruction

Toto TEN40AW V105 installation manual

Toto

Toto TEN40AW V105 installation manual

Lefroy Brooks C1-1110 installation instructions

Lefroy Brooks

Lefroy Brooks C1-1110 installation instructions

Lefroy Brooks M1-2153 Installation, operating,  & maintenance instructions

Lefroy Brooks

Lefroy Brooks M1-2153 Installation, operating, & maintenance instructions

Lefroy Brooks CW-1050 Installation, operating,  & maintenance instructions

Lefroy Brooks

Lefroy Brooks CW-1050 Installation, operating, & maintenance instructions

Kohler K-15182 Homeowner's guide

Kohler

Kohler K-15182 Homeowner's guide

VIGOUR DEFWIS Installation and operating instructions

VIGOUR

VIGOUR DEFWIS Installation and operating instructions

Sanipex BAGNODESIGN TOKO 3 BDM-TOK-303-A Series installation guide

Sanipex

Sanipex BAGNODESIGN TOKO 3 BDM-TOK-303-A Series installation guide

American Standard Avery 1180SB3020SS installation instructions

American Standard

American Standard Avery 1180SB3020SS installation instructions

Hans Grohe Vernis Blend Vario 04969 0 Series Installation/User Instructions/Warranty

Hans Grohe

Hans Grohe Vernis Blend Vario 04969 0 Series Installation/User Instructions/Warranty

Lefroy Brooks Y1-4500 installation instructions

Lefroy Brooks

Lefroy Brooks Y1-4500 installation instructions

Hans Grohe Decor 280 1jet 31817 3 Series Instructions for use and assembly instructions

Hans Grohe

Hans Grohe Decor 280 1jet 31817 3 Series Instructions for use and assembly instructions

BELLOSTA Joconde 4011/1A Installation instruction

BELLOSTA

BELLOSTA Joconde 4011/1A Installation instruction

Riobel Njoy Series installation guide

Riobel

Riobel Njoy Series installation guide

CRISTINA FOIL CRIFL686 installation instructions

CRISTINA

CRISTINA FOIL CRIFL686 installation instructions

miseno MNO1343CP quick start guide

miseno

miseno MNO1343CP quick start guide

Moen 5955 Series installation guide

Moen

Moen 5955 Series installation guide

Riobel AZURE AZ400 installation guide

Riobel

Riobel AZURE AZ400 installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.