Fema Electronica K40-CR User manual

Series K . K40-CR
Chronometer, me counter
Chronometer and me counter, with 20 mm digit height. Congurable with up and down counng
modes. Independent controls for start, stop and reset. Display modes in decimal format and sexagesi-
mal (clock) format. Standard 96 x 48 mm size (1/8 DIN). Reading with 4 digit display. Fast access to
alarm setpoints, special modes for counng exceeded me and totalized counng mes, ‘on power
up’ funcon, congurable led brightness. Universal AC and DC power. Up to 3 oponal modules for
output and control (relays, transistor, control SSR, analog outputs, Modbus RTU communicaons, RS-
485 ASCII, RS-232, ...) www.fema.es
User’s Manual
ELECTRONICS FOR INDUSTRIAL AUTOMATION
PANEL METERS . SIGNAL CONVERTERS . LARGE DISPLAYS
PANEL METERS
3620r05

FEMA ELECTRÓNICA . Series K . K40-CR
2
1. Panel meter K40-CR
Chronometer and me counter, size 96 x 48 mm (1/8 DIN), with 20 mm digit height
Panel meter 96 x 48 mm (1/8 DIN) and 4 digits with 20 mm digit
height, and funcon chronometer and me counter. Time displayed
in dierent formats covering hours, minutes, seconds and days.
Reading congurable in decimal and sexagesimal (clock) formats. Up
and down counng funcons, with congurable preset value.
Controls
Independent controls for ‘start’, ‘stop’ and ‘reset’ (see secon 1.6).
Controls acvated by default through free potenal contacts. Con-
gurable for acvaon with other control signals (NPN, PNP, induc-
ve, ...).
Reset
Reset control is provided by connecon at the rear of the instrument,
congurable to acvate by edge or by level. Front reset congurable
at the ‘LE’ keypad (see secon 1.7). Automac reset congurable
when reaching an alarm setpoint (see secon 1.7).
Special funcons
Special funcons with acvaon by connecon at the rear of the in-
strument. Includes control for counng direcon, total accumulated
mes, total exceeded me, hold of display reading and memory of
cicles (see secon 1.12.2).
Alarms
Independent alarms congurable as maximum or minimum, with
congurable acvaon and deacvaon delays and oponal invert-
ed acvaon of the relay. Alarms congurable in ‘normal’ mode or
‘repeat’ mode. In ‘repeat’ mode the alarm acvates every me the
congured setpoint me has passed (see secon 1.12.4).
The ‘on_alarm’ parameter allows to associated a predened funcon
to the acvaon of the alarm. Available funcons are : stop counng,
acvate the reset, set reading to ‘0’ or connue. Use ‘on_alarm’ con-
gured to ‘reset’ to implement repeve cycles of me which can be
counted by special funcon ‘B.2’ (see secon 1.12.2).
Flash
Several opons allow to congure the display ash in case of ‘stop’
or ‘start’ counng, or in case of alarm acvaon (see secon 1.12.4).
Security on start-up
The ‘On power-up’ funcon denes a me of inacvity of the instru-
ment aer power-up, the status of the instrument (‘start’ or ‘stop’)
aer power-up, and the opon to apply a reset aer power-up (see
secon 1.12.2).
Memory
The instrument saves and recovers the last reading value in case of
power-loss.
Congurable ‘fast-acess’ menu
The front key ‘UP’ () gives access to a user congurable menu with
direct access to several useful funcons such as alarm setpoints and/
or preset value (see secon 1.12.5).
Control and retransmission opons
Opons for output and control with 1, 2 and 3 relays, transistor out-
puts, controls for SSR relays, isolated analog outputs, communica-
ons in Modbus RTU, RS-485 ASCII and RS-232. Special opons with
4 and 6 relay outputs.
Mechanical
Front protecon IP65. Connecons by plug-in screw terminals. For
industrial applicaons.
1.1 How to order
K40 CR
Model Power
-
Opon 1 Others
H
- - -
Opon 2
-
Opon 3
-
-R1 (1 relay)
-AO (analog output)
-RTU (Modbus RTU)
-S4 (RS-485)
-S2 (RS-232)
-T1 (1 transistor)
-SSR (1 control SSR)
- (empty)
-H (85-265 Vac/dc)
-L (11/60 Vdc,
24 Vac, 48 Vac)
-NBT (no buons)
-65 (front IP65)
-G (green led)

FEMA ELECTRÓNICA . Series K . K40-CR
3
Index
1. Panel meter K40-CR . . . . . . . . . . . . . . . . . . . . . . 2
1.1 How to order . . . . . . . . . . . . . . . . . . . . . . . . 2
1.2 Included funcons . . . . . . . . . . . . . . . . . . . . . 4
1.3 Power connecons . . . . . . . . . . . . . . . . . . . . . 4
1.4 Front view . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.5 Rear view . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.6 Control connecons . . . . . . . . . . . . . . . . . . . . 5
1.7 Types of reset . . . . . . . . . . . . . . . . . . . . . . . . 5
1.8 Technical specicaons . . . . . . . . . . . . . . . . . . 6
1.9 Mechanical dimensions (mm) . . . . . . . . . . . . . . . 6
1.10 How to operate the menus. . . . . . . . . . . . . . . . 7
1.11 Messages and errors . . . . . . . . . . . . . . . . . . . 7
1.12 Conguraon menu. . . . . . . . . . . . . . . . . . . . 8
1.12.1 Inial set-up . . . . . . . . . . . . . . . . . . . . . . 8
1.12.2 Conguraon . . . . . . . . . . . . . . . . . . . . . 8
1.12.3 Controls conguraon . . . . . . . . . . . . . . . . 10
1.12.4 Alarms . . . . . . . . . . . . . . . . . . . . . . . . . 11
1.12.5 Fast access . . . . . . . . . . . . . . . . . . . . . . .12
1.12.6 Super fast access . . . . . . . . . . . . . . . . . . . 13
1.12.7 Menu ‘Key LE’ . . . . . . . . . . . . . . . . . . . . .13
1.12.8 Le zeros . . . . . . . . . . . . . . . . . . . . . . . . 13
1.12.9 Funcon ‘Password’ . . . . . . . . . . . . . . . . . . 13
1.12.10 Factory reset . . . . . . . . . . . . . . . . . . . . .13
1.12.11 Firmware version. . . . . . . . . . . . . . . . . . . 13
1.12.12 Brightness . . . . . . . . . . . . . . . . . . . . . . 13
1.12.13 Access to oponal modules . . . . . . . . . . . . . 13
1.13 Full conguraon menu . . . . . . . . . . . . . . . . . 14
1.14 Factory conguraon . . . . . . . . . . . . . . . . . . .16
1.15 Applicaon example 1 . . . . . . . . . . . . . . . . . . 17
1.16 Applicaon example 2 . . . . . . . . . . . . . . . . . . 17
1.17 To access the instrument . . . . . . . . . . . . . . . . .18
1.18 Modular system . . . . . . . . . . . . . . . . . . . . . .18
1.19 Precauons on installaon . . . . . . . . . . . . . . . .19
1.20 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . 19
1.21 CE declaraon of conformity . . . . . . . . . . . . . . . 19
2. Output and control modules . . . . . . . . . . . . . . . . . 20
2.1 Module R1. . . . . . . . . . . . . . . . . . . . . . . . . . 20
2.2 Module T1. . . . . . . . . . . . . . . . . . . . . . . . . . 20
2.3 Module SSR . . . . . . . . . . . . . . . . . . . . . . . . .21
2.4 Module AO . . . . . . . . . . . . . . . . . . . . . . . . . 21
2.6 Module RTU. . . . . . . . . . . . . . . . . . . . . . . . . 22
2.5 Module S4. . . . . . . . . . . . . . . . . . . . . . . . . . 22
2.7 Module S2. . . . . . . . . . . . . . . . . . . . . . . . . . 23
2.8 Modules R2, R4, R6. . . . . . . . . . . . . . . . . . . . . 23
3. Other opons . . . . . . . . . . . . . . . . . . . . . . . . . . 24
3.1 Opon NBT . . . . . . . . . . . . . . . . . . . . . . . . . 24
4. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .25
4.1 THM benchtop housing . . . . . . . . . . . . . . . . . . 25
4.2 Adapter DRA-M . . . . . . . . . . . . . . . . . . . . . . . 25
4.3 Adapter KA96 . . . . . . . . . . . . . . . . . . . . . . . .25
4.4 WME housing . . . . . . . . . . . . . . . . . . . . . . . . 25
4.5 Protector KIP . . . . . . . . . . . . . . . . . . . . . . . . 25

FEMA ELECTRÓNICA . Series K . K40-CR
4
1.2 Included funcons
Funcons included Secon
Fast access yes, congurable 1.12.5
Preset yes, congurable 1.12.1
Reset
yes, congurable : front,
rear and/or linked to
alarm acvaon
1.7
Counng direcon up or down 1.12.1
Memory yes, recovers at power-up
Funcons ‘on alarm’ yes 1.12.4
Special funcons
control up / down
cycle counter
accumulated counter
exceeded counter
hold control
memory for ‘shorter cycle’
and ‘longer cycle’
1.12.2
‘On Power Up’ yes 1.12.2
Password blocks conguraon 1.12.9
Alarms
acvaon delay
deacvaon delay
inverted relay
locked deacvaon
1.12.4
Display brightness 5 levels 1.12.12
Table 1 - Funcons included
Earth connecon - Although a
terminal is provided for earth
connecon, this connecon is
oponal. The instrument does
not need earth connecon for
correct operaon nor for com-
pliance with the security regu-
laons. ~
~+
-
8 9 0
Fuse - To comply with security regulaon 61010-1, add to the power
line a protecon fuse acng as disconnecon element, easily acces-
sible to the operator and idened as a protecon device.
Power ‘H’ fuse 250 mA me lag
Power ‘L’ fuse 400 mA me lag
1.3 Power connecons
Buon ‘LE’
1.4 Front view
Buon ‘UP’
Logo
Alarms
Units
Buon ‘SQ’
‘Conguraon menu’
(see secon 1.12)
‘Fast access‘
(see secon 1.12.5)
Front reset
(see secon 1.12.7)
Controls
(see secon 1.6)
Opon 1 Opon 2Opon 3
Power
(see secon 1.3)
Detail of the plug-in screw terminals provided with
the instrument. The instrument is provided with all
terminals needed, both male and female.
1.5 Rear view
Control led*
* The ‘led control’ is operave only in counng modes that do not
display seconds or tenths of second. It ashes ‘on’ and ‘o’ at a rate
of 1 second when instrument is counng (‘start’). It remains ‘o’
when the instrument is not counng (’stop’).
12345 890

FEMA ELECTRÓNICA . Series K . K40-CR
5
1.6 Control connecons
Vexc.
12345
Stop
Reset
0 V
Start
• Normal connecons (‘con.a’) - controls for ‘start’, ‘stop’ and ‘re-
set’ are independent. Acvaon by default is by falling edge (by
short-circuit to the 0 Vdc terminal). Internal pull-up resistors are
acvated. This is the normal working mode.
To work with other control signals or acvaons, congure the in-
ternal pull-up / pull-down resistors, the trigger level and the acva-
on by rising or falling edge (see secon 1.12.3).
Vexc.
12345
funcon ‘B’
Reset
0 V
Start / Stop
• Alternave connecons (‘con.b’) - the ‘start’ and ‘stop’ controls
share the same terminal ‘1’. Terminal ‘1’ at high level acvates the
‘start’. Terminal ‘1’ at low level acvates the ‘stop’. The ‘reset’ con-
trol is independent at terminal 5. Terminal ‘3’ is now dedicated to
acvate signal ‘B’. See secon 1.12.2 for more informaon on func-
ons associated to the acvaon of the ‘B’ signal. Acvang on
the conguraon menu a ‘B’ funcon, automacally acvates the
‘alternave connecons’ mode.
The reset funcon can be acvated from three independent and con-
gurable sources:
• Front reset - associated to the front buon ‘LE’ (3). This reset can
be disabled by menu (see secon 1.12.7). The front reset is acvated
by levels (pressed / not pressed).
• Rear reset - connected to pin 5 at the rear terminal. It acvates
by default on falling edge, by connecon to the 0 Vdc terminal. Ac-
vaon is congurable (see secon 1.12.2) by edge (falling or rising)
or level (up or down). Trigger level is congurable between 0 and
3.9 Vdc. Internal congurable pull-up / pull-down resistors allow to
use other type of sensors (NPN, PNP, push-pull, inducves, TTL, ...).
• Alarm reset - alarms 1, 2 and 3 can be congured to acvate a
certain funcon (a reset for example) when alarm acvates (see sec-
on 1.12.4). This conguraon creates innite loops which can be
counted by using funcon ‘B.2 cycles’ (see secon 1.12.2).
1.7 Types of reset
Reading
Minutes
Setpoint 1
Chronometer with ‘reset’ acvaon when read-
ing reaches setpoint 1 (‘15.00’ minutos)
Minutes
Cycle counter
01
2
15.00
0.00
15.00 30.00 45.00

FEMA ELECTRÓNICA . Series K . K40-CR
6
1.9 Mechanical dimensions (mm)
1.8 Technical specicaons
Digits
number of digits 4
led 7 segments led
color red
digit height 20 mm
Reading modes
* Meaning : (d=days, h=hours, m=minutes, s=seconds, c=cents of second)
Sexagesimal reading modes
mm.ss
hh.mm
dd.hh
Decimal reading modes
ssss mmmm hhhh
sss.s mmm.m hhh.h
ss.ss mm.mm hh.hh
maximum reading 99.59 / 99.23 / 9999
minimum reading -19.59 / -19.23 / -1999
Accuracy of the quartz ±0.01 %
Thermal dri 20 ppm / ºC
Controls start, stop, reset
default signal free potenal contact
congurable for ... NPN, PNP, Namur, pick-up, TTL, induc-
ve, mechanical, ...
maximum Vdc on terminals ±30 Vdc
excitaon voltage congurable
+18 Vdc, +15 Vdc, +9 Vdc, +5 Vdc
maximum current 70 mA
protecon yes, current limited to 70 mA
Display refresj 12 refresh/ second
retenon memory yes, recovers counng value in case of
power-loss
Power
power ‘H’ 85 to 265 Vac/dc
power ‘L’ 11 to 60 Vdc and 24/48 Vac
isolaon* 2500 Ve with power‘H’
1500 Ve with power ‘L’
*tested during 60 seconds.
consumpon <1.5 W only meter
<4.0 W meter with opons
Conguraon 3 buons front keypad
Front protecon IP65
Output and control opons relays, analog outputs, serial communi-
caons (see secon 2)
Mechanical
mounng panel
connecons plug-in screw terminal
housing material ABS, polycarbonate (V0)
weight <150 grams
front size 96 x 48 mm (1/8 DIN)
panel cut-out 92 x 44 mm
depth from panel 91 mm (including terminals)
Temperature
operaon from 0 to +50 ºC
storage from -20 to +70 ºC
warm-up me 15 minutes
44
92
Panel
cut-out
16 8
75
96
48

FEMA ELECTRÓNICA . Series K . K40-CR
7
The instrument has two menus accessible to the user :
‘Conguraon menu’ (key SQ) (<)
‘Fast access’ menu (key UP) (5)
Conguraon menu
The ‘conguraon menu’ modies the conguraon parameters to
adapt the instrument to the applicaon needs. To access the ‘con-
guraon menu’ press for 1 second the SQ (<) key. This access can
be blocked by acvang the ‘Password’ (‘PASS’) funcon. While
operang the ‘conguraon menu’, the alarm status is ‘hold’ to the
status they had before accessing the menu, and the output and con-
trol modules remain in ‘error’ state. When leaving the ‘conguraon
menu’, the instrument applies a system reset, followed by a brief
disconnecon of the alarms and the output and control modules.
Funconality is then recovered.
For a detailed explanaon on the ‘conguraon menu’ see secon
1.12, and for a full view of the ‘conguraon menu’ structure see
secon 1.13.
‘Fast access’ menu
The ‘fast access’ menu is an operator congurable menu, providing
fast and direct access to the most usual funcons of the instrument
with a single key pad stroke. Press key UP (5) to access this menu.
See secon 1.12.5 for a list of funcons eligible for ‘fast access’ in
this instrument. The ‘Password’ (‘PASS’) funcon does not block ac-
cess to this menu. Accessing and modifying parameters in the ‘fast
access’ menu does not interfere with the normal funconality of the
instrument, and it does not generate any system reset when validat-
ing the changes.
Front key pad descripon
Key SQ (<) - press the SQ (<) key for 1 second to access the ‘con-
guraon menu’. Inside the menu, the SQ (<) key funcons as a
‘ENTER’ key. It selects and accesses the menu opon currently dis-
played. At menus with numerical value entries, it validates the num-
ber displayed.
Key UP (5) - the UP (5) key gives access to the ‘fast access’ menu.
Inside the menus, it moves vercally through the dierent menu op-
ons. At menus with numerical value entries, it modies the digit
selected by increasing its value to 0, 1, 2, 3, 4, 5, 6, 7, 8, 9.
Key LE (3) - inside the menus, the LE (3) key funcons as the ‘ES-
CAPE’ key. It leaves the selected menu, and eventually, will leave the
whole menu. When leaving the ‘conguraon menu’ with the LE (3)
key, the changed parameters are acvated. At menus with numeri-
cal value entries, the LE (3) key allows to select the acve digit. To
modify the value of the selected digit use the UP (5) key.
Menu ‘rollback’
Aer 30 seconds without interacon from the operator, the instru-
ment will rollback and leave the ‘conguraon menu’ or the ‘fast ac-
cess’ menu. All changes will be discarded.
1.10 How to operate the menus
Example of operaon inside the
‘conguraon menu’.
1. The SQ (<) key enters into the
‘conguraon menu’.
2. The SQ (<) key enters into the
‘Func’ opon menu.
3. The UP (5) key moves through
the menu opons.
4. The SQ (<) key selects the
desired range and returns to the
‘Func’ menu.
5. The LE (3) key leaves the ac-
tual menu level and moves to the
previous menu level.
6. The LE (3) key leaves the ‘con-
guraon menu’. Changes are ap-
plied and saved at this moment.
Funcon
mode
(2)
(3)
(3)
(3)
(3)
(4)
(4)
(4)
(5)
(5)
(5)
(3)
(3)
(6)
(6)
(1)
Messages and errors
‘Err.1’ incorrect password.
‘Err.2’ at ‘oPt.X’ menu entry. Installed module is not recognized.
‘Err.8’ excitaon voltage overload.
‘9999’ + ashing mode. Reading is in overrange.
‘-1999’ + ashing mode. Reading is in underrange.
Table 2 - Messages and error codes
The error messages are shown on display in ash mode.
1.11 Messages and errors

FEMA ELECTRÓNICA . Series K . K40-CR
8
Press ‘SQ’ (<) for 1 second to access the ‘conguraon menu’.
For a descripon on how to operate inside the menus see secon
1.10. For a full vision of the ‘conguraon menu’ structure see
secon 1.13.
To congure the inial set up of the instrument, select the viewing
format, congure the up or down counng mode and assign the pre-
set value.
Enter the ‘Funcon mode’ (‘Func’) menu and select the ‘View’ for-
mat desired.
• ‘MM.SS’ - clock format, minutes and seconds.
• ‘hh.MM’ - clock format, hours and minutes.
• ‘dd.hh’ - clock format, days and hours.
• ‘SSSS’ - counter of seconds.
• ‘SSS.S’ - counter of seconds with one decimal.
• ‘SS.SS’ - counter of seconds with two decimals.
• ‘MMMM’ - counter of minutes.
• ‘MMM.M’ - counter of minutes with one decimal.
• ‘MM.MM’ - counter of minutes with two decimal.
• ‘hhhh’ - counter of hours.
• ‘hhh.h’ - counter of hours with one decimal.
• ‘hh.hh’ - counter of hours with two decimal.
Access the ‘Counng direcon’ (‘dIr’) and select ‘uP’ for up counng
or ‘doWn’ for down counng.
At the ‘Preset’ (‘PrSt’) menu select the preset value. The preset value
will load on display when reset funcon acvates. See secon 1.7 for
a descripon on the dierent acvaon modes for the reset.
Addional conguraon parameters for the instrument.
The ‘On Power Up’ (‘on.Pu’) menu congures funcons to apply at
start-up. It applies only to instrument restart aer power loss. It does
not apply to instrument restart due to change in conguraon.
• parameter ‘Delay’ (‘dLAy’) assigns a waing me in seconds. The in-
strument waits the congured me before starng normal funcon.
During this waing me, the display shows all decimal points on in
ash mode, all alarms are in ‘oFF’ state, there is no signal acquision
and there is no communicaons or control being performed. Aer
the congured me is over, the instrument starts in normal funcon.
Applicaon - the start-up process for an automaon system implies
that dierent parts of the system (engines, actuators, controllers, ...)
have dierent start-up mes. The ‘Delay’ funcon gives me to the
instrument to wait unl the slowest part of the system is fully func-
onal before execung acons on the system (signal reading, relay
acvaon, ...).
• the ‘Reset’ (‘rSt’) parameter will execute a reset of the counter
each me the instrument is restarted.
1.12.2 Conguraon
1.12 Conguraon menu
1.12.1 Inial set-up
Funcon
mode
Preset
Preset value
-1999 to 9999
Counng
direcon
Up
Down
View format
Conguraon On power-up Delay Seconds
Reset
State
0 to 9999
0.0 to 999.9
0.00 to 99.99
0 to 9999
0.0 to 999.9
0.00 to 99.99
0 to 9999
0.0 to 999.9
0.00 to 99.99
0.00 to 99.59
0.00 to 99.59
0.00 to 99.23

FEMA ELECTRÓNICA . Series K . K40-CR
9
• the ‘State’ (‘StAt’) parameter controls the state of the counter aer
power-up. Select ‘Strt’ to count aer power-up or ‘StoP’ to remain
stopped aer power-up.
The whole power-up process of the instrument is explained as fol-
lows : instrument waits the me dened at ‘Delay’, it then resets (or
not) the counter according to parameter ‘Reset’, then it counts or
remains stopped according to parameter ‘StAt’ and then it checks for
external controls ‘start’, ‘stop’ and ‘reset’.
The ‘Flash’ menu (‘FLSh’) controls the acvaon of the rear reset by
edge (‘EdGE’) or by level (‘LEVL’).
The ‘Rear reset’ menu (‘r.rSt’) controls the acvaon of the display
ashing when instrument is stopped (‘StP.F’) and / or when instru-
ment is counng (‘StP.F’).
The ‘Funcon on channel ‘B’’ menu (‘Fn.b’) controls the acvaon
of special funcons on channel ‘B’ (rear terminal 4). If a ‘B’ funcon
is selected, signal connecons change to ‘alternave connecons’ as
indicated at secon 1.6.
Following is an explanaon for each of the 6 ‘B funcons’ available.
• funcon ‘B.1 control up / down’ (‘Fn.b.1’) controls the up or down
counng based on the state of input signal at channel ‘B’.
• funcon ‘B.2 cycles’ (‘Fn.b.2’) enables an internal counter (from 0
to 9999) which can be made visible on display by acvaon of chan-
nel ‘B’ signal. There are several events that can add ‘+1’ to this inter-
nal counter :
• ‘on alarm 1’ (‘o.AL1’) select ‘on’ to add ‘+1’ each me alarm
1 acvates.
• ‘on alarm 2’ (‘o.AL2’) select ‘on’ to add ‘+1’ each me alarm
2 acvates.
• ‘on alarm 3’ (‘o.AL3’) select ‘on’ to add ‘+1’ each me alarm
3 acvates.
• ‘on reset’ (‘o.rSt’) select ‘on’ to add ‘+1’ each me reset
funcon acvates.
• funcon ‘B.3 accumulated’ (‘Fn.b.3’) enables an internal counter
which can be made visible on display by acvaon of channel ‘B’
signal. To reset the accumulated counter, view the counter on dis-
play and acvate the reset (front or rear). The accumulated counter
counts the totalized me that the instrument has been counng or
stopped (needs to be powered-up).
• parameter ‘Format’ (‘ForM’) congures the view format for
the accumulated counter. Value ‘ch.A’ views in same format
as the main instrument.
• at parameter ‘Count’ (‘cnt’) select ‘ALWS’ to count the total
me that the instrument has been powered. Select ‘Strt’ to
count the total me the instrument has been counng. Se-
lect ‘StoP’ to count the total me the instrument has been
stopped.
1.12 Conguraon menu (cont.)
Flash ‘Flash on stop’
‘Flash on start’
Rear reset
acvates by edge
acvates by level
Funcon
on channel ‘B’
Funcon assigned to
channel ‘B’. Select-
ing a ‘B’ funcon
automacally ac-
vates connecon type
‘Con.2’ (see secon
1.6)
Funcon B.1
control up / down
Next menu entry gives access to the conguraon parameters of the ‘chan-
nel ‘B’ funcon’ (‘Fn.b’) previously selected. If no funcon has been selected,
menu entry indicates ‘Fn.b.n’. Following is an explanaon for menus ‘Fn.b.1’
to ‘Fn.b.6’.
Funcon B.2
cycles
‘on alarm 1’
‘on alarm 2’
‘on alarm 3’
on ‘reset’
Funcon B.3
accumulated
Count
Format

FEMA ELECTRÓNICA . Series K . K40-CR
10
1.12 Conguraon menu (cont.)
Funcon B.4
exceeded
‘Start’
Funcon B.5
‘hold’
Funcon B.6
‘Max / min’
Controls
Acvaon for
‘Start’ and ‘Stop’
Pulls for
‘Start’ and ‘Stop’
Pull down
No pull
Pull up
Pulls for reset
Pull down
No pull
Pull up
by rising edge
by falling edge
Acvaon for
‘reset’
by rising edge
by falling edge
• funcon ‘B.4 exceeded’ (‘Fn.b.4’) enables an internal counter for
exceeded me, which can be made visible on display by acvaon of
channel ‘B’ signal. To reset the exceeded counter, view the counter
on display and acvate the reset (front or rear). The reset leaves the
exceeded counter at a value of ‘0’ and in ‘Stop’ mode. The exceeded
counter counts the totalized me aer a certain event triggers the
start of the internal counter.
• at the ‘Start’ (‘Strt’) parameter select ‘o.AL1’ to start the
exceeded counter when alarm 1 acvates. Select ‘o.AL2’ or
‘o.AL3’ to trigger the counter on acvaon of alarm 2 or 3.
• parameter ‘Format’ (‘ForM’) congures the view format for
the exceeded counter. Value ‘ch.A’ views in same format as
the main instrument.
• funcon ‘B.5 hold’ (‘Fn.b.5’) controls the hold of the display by
controlling the state of the signal at channel ‘B’. The chronometer
connues counng on the background.
• funcon ‘B.6 max / min’ (‘Fn.b.6’) internally saves the maximum
and minimum mes recorded of a certain cycle. Each me a reset is
acvated, the instrument compares the actual reading value with the
previous saved memorized values. It replaces the minimum value if
the actual value is smaller. It replaces the maximum value if the actu-
al value is larger. Minimum and maximum values are visible through
front key UP (5) (see secon 1.12.5).
Applicaon - a producon process executes a reset signal each me
a producon element has been nished. At the end of the day, the
maximum and minimum producon mes can be accessed.
1.12.3 Controls conguraon
The ‘Controls’ conguraon menu (‘SnSr’) provides conguraon for
the ‘start’, ‘stop’ and ‘reset’ controls. Default conguraon is acva-
on by free potenal contacts, with acvaon by falling edge (direct
connecon to terminal 0 Vdc). The following parameters allow to
congure the instrument controls to work with other type of signals
(NPN, PNP, inducves, ...).
• ‘Pulls for ‘Start’ and ‘Stop’’ (‘PuL.S’) - select ‘P.uP’ to ac-
vate pull-up resistors (needed for NPN sensors). Select ‘P.dn’
to acvate pull-down resistors (needed for PNP sensors).
Select ‘no’ to deacvate pulls. Selecng a pull resistors congures
the trigger level to 2,5 Vdc.
• ‘Acvaon for ‘Start’ and ‘Stop’’ (‘Act.S’) - select (‘on_h’) to ac-
vate the ‘Start’ and ‘Stop’ controls by rising edge. Select (‘on_0’) to
acvate by falling edge.
• ‘Pulls for reset’ (‘PuL.r’) - select ‘P.uP’ to acvate pull-
up resistors (needed for NPN sensors). Select ‘P.dn’ to ac-
vate pull-down resistors (needed for NPN sensors).
Select ‘no’ to deacvate pulls. Selecng a pull resistors congures
the trigger level to 2,5 Vdc.
• ‘Acvaon for ‘Reset’’ (‘Act.r’) - select (‘on_h’) to acvate the
‘Reset’ control by rising edge. Select (‘on_0’) to acvate by falling
edge. Addionally, reset signal can be congured to acvate by lev-
els instead of edges (see secon 1.12.2). In case of acvaon by lev-
Format

FEMA ELECTRÓNICA . Series K . K40-CR
11
1.12 Conguraon menu (cont.)
Trigger level
Trigger level (from
0 to 31). Each
level is approx.
0.128 Vdc.
Excitaon
voltage
Anrrebound
Anrrebound lter
(0 to 1000 mSec.)
Alarms
Alarm 1 Alarm mode
Deacvated
Normal
Repeat
Setpoint
Type of alarm
els, value ‘on_h’ acvates the reset on high signal value, and value
‘on_0’ acvates reset on low signal. Front reset acvates always by
state.
• ‘Trigger level’ (‘trIG’) - select the signal voltage level at which the
instrument will consider that the signal has reached the acvaon
level. Selectable from 0 to 31 levels, where each level is approx.
imately 0.128 Vdc. Trigger level is the same for channels ‘start’ and
‘stop’. Reset channel has a xed trigger to 2,5 Vdc. The three leds to
the le of the value reect the state (‘0’ or ‘1’) of control channels
‘Start’, ‘Stop’ and ‘Reset’.
• ‘Excitaon voltage’ (‘V.EXc’) - power provided by the instrument
to power-up the sensors (if needed) used to control the signals
‘start’, ‘stop’ and / or ‘reset’, or to be used as an acve signal (‘1’) for
special connecons. Select the for the excitaon voltage at 5 Vdc,
9 Vdc, 15 Vdc or 18 Vdc. Select ‘no’ to disable the excitaon voltage.
• ‘Anrrebound lter’ (‘rbnd’) - Vlue between 0 mSeconds and
1000 mSeconds. when a signal is received, detecon of addional
signals is inhibited for the me dened in this parameter. Recom-
mended value for a mechanical contact sensor is 100 mSeconds.
Applies to ‘start’, ‘stop’ and ‘reset’ signals.
The ‘Alarms’ (‘ALr’) menu congures the independent acvaon of
up to 3 relay outputs (or transistor or SSR control), installed with the
R1 (or T1 or SSr) oponal modules (see secon 2.1). For outputs up
to 4 and 6 relays, see special modules R2, R4 and R6 at secon 2.6.
The alarm states are indicated in the front display with leds marked
as ‘1’, ‘2’ and ‘3’.To congure an alarm, enter into the alarm menu
(‘ALr1’, ‘ALr2’ or ‘ALr3’) and congure the following parameters :
• parameter ‘Alarm mode’ (‘Mode’) allows to disable the alarm
(‘oFF’) or to select between two working modes :
•in ‘normal’ mode (‘norM‘) the alarm has a setpoint con-
gured, that acvates when the display reading reaches the
setpoint value. It can be congured as a ‘maximum alarm’ or
‘minimum alarm’. Provides conguraon for independent ac-
vaon and deacvaon delays, ash control and acon se-
lecon on acvaon.
• in ‘repeat’ mode (‘rEPt’) the alarm acvates each me that
the chronometer reaches a mulple of the setpoint. Alarm
remains acve during the me indicated at parameter ‘de-
acvaon delay’ (‘dEL.1’). Other parameters on the ‘Alarm’
menu have no eect in this mode. This mode is not funconal
in viewing modes with tenths of second or cents of second.
Applicaon : chronometer in ‘mm.ss’ mode with a’repeat’
alarm and setpoint 1 at ‘15.00’. Alarm acvates ar ‘15.00’,
‘30.00’, ‘45.00’, etc.
• at ‘Alarm type’ (‘TypE’) select the alarm to act as a maximum type
alarm (‘MAX’) or a minimum type alarm (‘MIn’). The maximum type
alarm (or minimum type alarm) acvates when the display value is
higher (or lower) than the setpoint value.
• at ‘Setpoint’ (‘SEt’) enter the value for the alarm acvaon point.
This parameter is eligible for conguraon through the ‘Fast access’
menu (see secon 1.12.5).
1.12.4 Alarms

FEMA ELECTRÓNICA . Series K . K40-CR
12
1.12 Conguraon menu (cont.)
‘On alarm’
Connue
To zero
To preset
Inverted relay
‘Locked alarm’
Stop
‘Alarm ash’
Acvaon delay
Deacvaon
delay
Tools
Key UP
(‘Fast access’)
Memory of
maximum
Memory of
minimum
Setpoint 1
Setpoint 2
Setpoint 3
Memory of
cycles
Preset value
• at ‘Acvaon delay’ (‘dEL.0’) congure the delay to apply before
alarm acvaon. The acvaon delay starts counng when the set-
point value is passed. Value from 0.0 to 99.9 seconds.
• at ‘Deacvaon delay’ (‘dEL.1’) congure the delay to apply
before alarm deacvaon. The deacvaon delay starts counng
when the setpoint value plus the hysteresis value, is passed. Value
from 0.0 to 99.9 seconds.
• the ‘Relay inverted’ (‘r.Inv’) parameter inverts the normal relay
connecons. When set to ‘on’ the relay will be acve when alarm is
inacve. For security applicaons where an inacve relay controls
the shutdown of the system.
• the ‘Locked alarm’ (‘A.Lck’) parameter disables the automac
deacvaon of the alarm. Alarm deacvaon must be performed
manually, by pressing the ‘LE’ front buon (see secon 1.12.7)
• the ‘On alarm’ (‘on.AL’) parameter assigns a predened behavior
when alarm acvates.
• select ‘cont’ to connue counng.
• select ‘to_0’ to load ‘0’ on displays Parameter ‘deacvaon
delay’ (‘dEL.1’) automacally congures to 1 second.
• select ‘to_p’ to load preset value on display. Parameter ‘de-
acvaon delay’ (‘dEL.1’) automacally congures to 1 sec-
ond.
• select ‘stop’ to stop the counng.
• set the ‘Alarm ash’ (‘AL.FL’) parameter to ‘on’ to acvate the
ash of the display when alarm is acve. To manually deacvate the
ash mode, press any of the front keys or change the state of any of
the control signals ‘start’, ‘stop’ or ‘reset’.
The ‘UP’ (5) key at the front of the instrument gives access to a list
of funcons congurable by the operator. See secon 1.10 for an ex-
planaon on how to operate the ‘fast access’ menu.
The ‘Key UP (Fast access)’ (‘K.uP’) menu allows to select which func-
ons will be accessible through the ‘fast access’ menu. Select ‘on’ to
acvate each funcon.
• the ‘Setpoint 1’ (‘ALr1’) funcon allows to visualize and modify the
alarm 1 setpoint through the ‘fast access’ menu.
• the ‘Setpoint 2’ (‘ALr2’) funcon allows to visualize and modify the
alarm 2 setpoint through the ‘fast access’ menu.
• the ‘Setpoint 3’ (‘ALr3’) funcon allows to visualize and modify the
alarm 3 setpoint through the ‘fast access’ menu.
• the ‘Memory of maximum’ (‘MAX’) or ‘Memory of minimum’
(‘MIn’) funcons allow to visualize the maximum or minimum read-
ing value stored in memory. To reset this value, visualize the memory
value at the ‘fast access’ menu with key UP (5) and when message
‘rSt’ is displayed, press (<) to reset.
• the ‘Memory of cycles’ (‘cYcL’) funcon allow to visualize and reset
the memory of cycles. To reset this value, visualize the memory value
at the ‘fast access’ menu with key UP (5) and when message ‘rSt’
is displayed, press (<) to reset. The memory of cycles countes ‘+1’
each me a reset alarm occurs (‘on_AL’ / ‘to_0’ or ‘to_P’) or a reset
by ‘overrange’ / ‘underrange’ occurs.
• the ‘Preset value’ (‘PrSt’) funcon allows to visualize and modify
the preset value congured.
1.12.5 Fast access

FEMA ELECTRÓNICA . Series K . K40-CR
13
1.12 Conguraon menu (cont.)
If only a single funcon is selected for the ‘fast access’ menu, press-
ing the the ‘UP’ (5) key will shortly display the funcon name and
then automacally jump to the funcon value.
1.12.6 Super fast access
Le zeros
With le zeros
Without le zeros
Password
Factory reset
Version
Minimum
Brightness
Maximum
Standard
Opon 1
Conguraon menu for the module installed at Opt.1
Opon 2
Conguraon menu for the module installed at Opt.2
Opon 3
Conguraon menu for the module installed at Opt.3
The ‘LE’ (3) key at the front of the instrument can be congured to
acvate several funcons. Only one funcon can be assigned to the
‘LE’ (3) key
• the ‘No funcon’ (‘nonE’) value assigns no funcon.
• the ‘Reset’ (‘rSt’) value asigns the reset funon to the ‘LE’ (3) key.
• the ‘Reset + Start’ (‘r.Str’) value asigns the reset and start funcon
to the ‘LE’ (3) key.
• the ‘Alarm unlock’ (‘A.Lck’) value assigns the manual unlock of the
alarms funcon, for instruments with the ‘Locked alarms’ (‘A.Lck’)
funcon acvated (see secon 1.12.4)
1.12.7 Menu ‘Key LE’
At the ‘Password’ (‘PASS’) menu select a 4 digit code to block access
to the ‘conguraon menu’. Instrument conguraon will not be ac-
cessible to non authorized personnel. To acvate the ‘Password’ se-
lect ‘on’ and introduce the code.
The code will be requested when trying to access the ‘conguraon
menu’ (key ‘SQ’ (<)). The ‘fast access’ menu is not password pro-
tected.
The ‘Version’ (‘VEr’) menu informs of the current rmware version
installed in the module.
At the ‘Brightness’ (‘LIGh’) menu select the light intensity for the
front leds. With this funcon it is possible to adapt the instrument to
the environment light intensity.
1.12.8 Le zeros
Menus ‘OPt.1’, ‘OPt.2’ and ‘OPt.3’ give access to the ‘conguraon
menus’ of the output and control modules installed at slots Opt.1,
Opt.2 and Opt.3.
See secon 2 for a list of output and control modules available for
each slot. The ‘conguraon menu’ of each module is described at
the User’s Manual of each module.
1.12.9 Funcon ‘Password’
At the ‘Factory reset’ (‘FAct’) menu, select ‘yes’ to load the default
factory conguraon for the instrument (see secon 1.14).
1.12.10 Factory reset
1.12.11 Firmware version
1.12.12 Brightness
The ‘Le zeros’ (‘L.ZEr’) parameter controls the le zeros on or o.
1.12.13 Access to oponal modules
Key LE
Reset
Alarm unlock
No funcon
Reset + Start

FEMA ELECTRÓNICA . Series K . K40-CR
14
1.13 Full conguraon menu
Press ‘SQ’ (<) for 1 second to access the ‘Conguraon menu’. See
secon 1.12 for a descripon of each menu entry.
Funcon
mode
Preset
Preset value
-1999 to 9999
Counng
direcon
Up
Down
Funcon
on channel ‘B’
Funcon assigned to
channel ‘B’. Select-
ing a ‘B’ funcon
automacally ac-
vates connecon type
‘Con.2’ (see secon
1.6)
Funcon B.1
control up / down
Next menu entry gives access to the conguraon parameters of the ‘channel ‘B’
funcon’ (‘Fn.b’) previously selected. If no funcon has been selected, menu entry
indicates ‘Fn.b.n’. Following is an explanaon for menus ‘Fn.b.1’ to ‘Fn.b.6’.
Funcon B.2
cycles
‘on alarm 1’
‘on alarm 2’
‘on alarm 3’
on ‘reset’
Funcon B.3
accumulated
Format
Count
Funcon B.4
exceeded
Format
View format
Conguraon
Flash ‘Flash on stop’
‘Flash on start’
On power-up Delay Seconds
Reset
State
Rear reset
acvates by edge
acvates by level
0 to 9999
0.0 to 999.9
0.00 to 99.99
0 to 9999
0.0 to 999.9
0.00 to 99.99
0 to 9999
0.0 to 999.9
0.00 to 99.99
0.00 to 99.59
0.00 to 99.59
0.00 to 99.23

FEMA ELECTRÓNICA . Series K . K40-CR
15
1.13 Full conguraon menu (cont.)
‘Start’
Funcon B.5
‘hold’
Funcon B.6
‘Max / min’
‘On alarm’
Connue
To zero
To preset
Alarm 1
Setpoint
Alarm mode
Type of alarm
Alarms
Acvaon delay
Deacvaon
delay
Inverted relay
‘Locked alarm’
Disabled
Normal
Repeat
Stop
‘Alarm ash’
Controls
Acvaon for
‘Start’ and ‘Stop’
Pulls for reset
Pulls for
‘Start’ and ‘Stop’
Acvaon for
‘reset’
Pull down
No pull
Pull up
Pull down
No pull
Pull up
by rising edge
by falling edge
by rising edge
by falling edge
Excitaon
voltage
Anrrebound
Anrrebound lter
(0 to 1000 mSec.)
Trigger level
Trigger level (from
0 to 31). Each
level is approx.
0.128 Vdc.

FEMA ELECTRÓNICA . Series K . K40-CR
16
1.13 Full conguraon menu (cont.)
Tools Key UP
(‘Fast access’)
Memory of
maximum
Memory of
minimum
Setpoint 1
Setpoint 2
Setpoint 3
Memory of
cycles
Preset value
Password
Factory reset
Le zeros
With le zeros
Without le zeros
Version
Minimum
Brightness
Maximum
Standard
Opon 2
Conguraon menu for the module installed at Opt.2
Opon 3
Conguraon menu for the module installed at Opt.3
1.14 Factory conguraon
Funcon mode
View format MM.SS
Counng direcon up
Preset 00.00
Conguraon
‘On power-up’
Delay 0 seconds
Reset o
State stopped (‘StoP’)
Flash
‘Flash on stop’ o
‘Flash on start’ o
Rear reset acvates by edges (‘EdGE’)
Funcon on channel ‘B’ no
Controls
Pulls for ‘start’ and ‘stop’ pull-up (‘P.uP’)
Acvaon for ‘start’ and ‘stop’ by falling edge (‘on_0’)
Pulls for reset pull-up (‘P.uP’)
Acvaon for reset by falling edge (‘on_0’)
Trigger level 2.56 Vdc (level 20)
Excitaon voltage 15 Vdc
Anrrebound lter disabled (0 mSeconds)
Alarms 1,2 and 3
Mode o (disabled)
Type of alarm of maximum
Setpoint 0
Acvaon delay 0.0 seconds
Deacvaon delay 0.0 seconds
Inverted relay o
‘Locked alarms’ o
‘On alarm’ connue
‘Alarm ash’ o
Herramientas (‘TooL’)
‘Fast acess’ (
key UP
) o
Setpoint 1 o
Setpoint 2 o
Setpoint 3 o
Memory of maximum o
Memory of minimum o
Cycles o
Preset o
Ley ‘LE’ reset funcon
Le zeros o
Password o
Brightness 3
on
o
Key LE
Reset
Alarm unlock
No funcon
Reset + Start
Opon 1
Conguraon menu for the module installed at Opt.1

FEMA ELECTRÓNICA . Series K . K40-CR
17
In an industrial process of electrolyc bath, the weed parts need
to be removed from the bath and replaced with new parts every 20
minutes. The process of removing and adding parts to the electro-
lyc bath is automated and takes 15 seconds. During these 15 sec-
onds, the system of electrolyc bath should receive no power supply,
which must be reacvated aer 15 seconds, when new items are
immersed in the bath.
The M60-CR chronometer can be congured to acvate a relay out-
put every 20 minutes, and this relay must remain acve for 15 sec-
onds. Aer this me, the relay will deacvate.
Addionally, the system needs the counter to start counng as soon
as power is received, although a 60 seconds delay is needed to give
me to the rst acvaon of the electrolyc bath. Counter must con-
nue counng from the value it had before the power was removed.
Conguraon would be as indicated below :
• View format
‘Func’ / ‘View’ ‘mm.ss’
• Counng direcon
‘Func’ / ‘dIr’up (‘uP’)
• Preset value
‘Func’ / ‘PrSt’ ‘0.00’
• Delay on power-up
‘conF’ / ‘on_Pu’ / ‘dLAY’ 60 seconds
• Inial reset disabled
‘conF’ / ‘on_Pu’ / ‘rSt’ ‘oFF’
• Start counng aer power-up
‘conF’ / ‘on_Pu’ / ‘StAt’ start (‘Strt’)
• Alarm mode
‘ALr’ / ‘ALr1’ / ‘Mode’ repeat (‘rEPt’)
• Alarm every 20 minutes
‘ALr’ / ‘ALr1’ / ‘SEt’ 20.00
• Deacvaon delay
‘ALr’ / ‘ALr1’ / ‘dEL.1’ 15.0 seconds
• On alarm acvaon
‘ALr’ / ‘ALr1’ / ‘on_AL’ connue (‘cont’)
1.15 Applicaon example 1
Alarm 1
Minutes
Chronometer with repeated acvaon of
alarm 1 aer 20 minutes
on
o
20.00 40.00 60.00
15 seconds
60 seconds
00.00
inial
start-up
An industrial process has an oven to dry dierent elements. The dry-
ing me of each element is variable, and the operator requires that
the seng of each drying me to be easily accessible and modiable.
The modicaon of other conguraon parameters must be locked.
During the process, the operator needs two signals. First signal ac-
vates a buzzer which should start 5 minutes before the end of the
scheduled drying me, and remain acve for 15 seconds. The second
signal must acvate at the end of the drying me and must remain
acve unl the operator manually the ‘reset’ signal.
The M60-CR chronometer can be congured for down counng, with
start me at preset value, which will be directly accessible and modi-
able when pressing the front key UP (‘5’). All conguraon pa-
rameters (except the ‘preset’ value) will be password locked. Alarm 1
will acvate for 15 seconds when 5 minutes are missing to end the
process. Alarm 2 will acvate when the scheduled me is over and
will remain acve unl the operator manually resets.
• View format
‘Func’ / ‘View’ ‘hh.mm’
• Counng direcon
‘Func’ / ‘dIr’down (‘doWn’)
• Alarm 1 : alarm mode
‘ALr’ / ‘ALr1’ / ‘Mode’ normal (‘norM’)
• Alarm 1 : type of alarm
‘ALr’ / ‘ALr1’ / ‘tYPE’ minimum (‘MIn’)
• Alarm 1 : acvaon setpoint
‘ALr’ / ‘ALr1’ / ‘SEt’ ‘00.05’
• Alarm 1 : deacvaon delay
‘ALr’ / ‘ALr1’ / ‘dEL.1’ 15.0 seconds
• Alarm 1 : connue counng when alarm acvates
‘ALr’ / ‘ALr1’ / ‘on_AL’ connue (‘cont’)
• Alarm 2 : alarm mode
‘ALr’ / ‘ALr1’ / ‘Mode’ normal (‘norM’)
• Alarm 2 : type of alarm
‘ALr’ / ‘ALr1’ / ‘tYPE’ minimum (‘MIn’)
• Alarm 2 : acvaon setpoint
‘ALr’ / ‘ALr1’ / ‘SEt’ ‘00.00’
• Alarm 1 : when alarm acvates, stop counng
‘ALr’ / ‘ALr1’ / ‘on_AL’ stop (‘stop’)
• Assign the preset value to the ‘UP’ front key
‘TooL’ / ‘K.uP’ / ‘PrSt’ ‘on’
• Conguraon block by password
‘TooL’ / ‘PASS’ / ‘on’ assign the password code
1.16 Applicaon example 2
State of alarm 1
on
o
15 seconds
Reading
me
Example with preset selected at 6 hours
and 30 minutes
‘06.30’
‘00.00
05.25. 05.30
0.00
‘00.05
State of alarm 2
on
o

FEMA ELECTRÓNICA . Series K . K40-CR
18
1.17 To access the instrument
1.18 Modular system
M Series panel meters are designed to create a modular system. This
modular system allows for addion, replacement or substuon of
any of the internal modules conforming the instrument. Below is a
graphic explanaon for the posion of each module.
Risk of electric shock. Removing the front cover will
grant access to the internal circuits. Disconnect the
input signal to prevent electric shock to the operator.
Operation must be performed by qualied personnel
only.
To open the housing, use a at screwdriver to free the xaon clips,
if possible, in the following order : D, C, B and A. Remove the front
cover. Let the inside of the instrument slide out of the housing.
To reinsert the instrument make sure that all modules are correctly
connected to the pins on the display module. Place all the set into
the housing, assuring that the modules correctly t into the internal
guiding slides of the housing. Once introduced, place again the front
cover in front of the housing, placing rst corner ‘X’ and then insert-
ing clips ‘A’, ‘B’, ‘C’ and ‘D’ in this order.
XA
C
BD
Front Filter Display Module Oponal Control Modules
Input Signal Module
Housing
Power Supply Module
Opt.3
Opt.2
Opt.1

FEMA ELECTRÓNICA . Series K . K40-CR
19
This instrument has been designed and veried conforming to the 61010-1
CE Security Regulaon, for industrial applicaons.
Installaon of this instrument must be performed by qualied personnel
only. This manual contains the appropriate informaon for the installaon.
Using the instrument in ways not specied by the manufacturer may lead to
a reducon of the specied protecon level. Disconnect the instrument from
power before starng any maintenance and / or installaon acon.
The instrument does not have a general switch and will start operaon as
soon as power is connected. The instrument does not have protecon fuse,
the fuse must be added during installaon.
The instrument is designed to be panel mounted. An appropriate venlaon
of the instrument must be assured. Do not expose the instrument to excess
of humidity. Maintain clean by using a humid rag and do NOT use abrasive
products such as alcohols, solvents, etc.
General recommendaons for electrical installaons apply, and for proper
funconality we recommend : if possible, install the instrument far from
electrical noise or magnec eld generators such as power relays, electrical
motors, speed variators, ... If possible, do not install along the same conduits
power cables (power, motor controllers, electrovalves, ...) together with sig-
nal and/or control cables.
Before proceeding to the power connecon, verify that the voltage level
available matches the power levels indicated in the label on the instrument.
In case of re, disconnect the instrument from the power line, re alarm
according to local rules, disconnect the air condioning, aack re with car-
bonic snow, never with water.
1.19 Precauons on installaon
Risk of electrical shock. Instrument terminals can be connected
to dangerous voltage.
Instrument protected with double isolaon. No earth connecon
required.
Instrument conforms to CE rules and regulaons.
1.20 Warranty
This instrument is warranted against all manufacturing defects for a
period of 24 MONTHS from the shipment date. This warranty does
not apply in case of misuse, accident or manipulaon by non-autho-
rized personnel. In case of malfuncon get in contact with your local
provider to arrange for repair. Within the warranty period and aer
examinaon by the manufacturer, the unit will be repaired or subs-
tuted when found to be defecve. The scope of this warranty is lim-
ited to the repair cost of the instrument, not being the manufacturer
eligible for responsibility on addional damages or costs.
1.21 CE declaraon of conformity
Manufacturer FEMA ELECTRÓNICA, S.A.
Almira 14 - Pol. Ind. Sanga
E08210 - Barberà del Vallès
BARCELONA - SPAIN
www.fema.es - info@fema.es
Products K40-CR
The manufacturer declares that the instruments indicated comply with the
direcves and rules indicated below.
Electromagnec compability direcve 2014/30/EU
Low voltage direcve 2014/35/EU
Direcve ROHS 2011/65/EU
Security rules EN-61010-1
Instrument Fixed
Permanently connected
Polluon degree 1 and 2 (without condensaon)
Isolaon Double
Electromagnec compability rules EN-61326-1
EM environment
Industrial
Immunity levels
EN-61000-4-2 By contact ±4 KV Criteria B
By air ±8 KV Criteria B
EN-61000-4-3 Criteria A
EN-61000-4-4 On AC power lines : ±2 KV Criteria B
On DC power lines : ±2 KV Criteria B
On signal lines : ±1 KV Criteria B
EN-61000-4-5 Between AC power lines ±1 KV Criteria B
Between AC power lines and earth ±2 KV Criteria B
Between DC power lines ±1 KV Criteria B
Between DC power lines and earth ±2 KV Criteria B
Between signal lines and earth ±1 KV Criteria B
EN-61000-4-6 Criteria A
EN-61000-4-8 30 A/m at 50/60 Hz Criteria A
EN-61000-4-11 0 % 1 cycle Criteria A
40 % 10 cycles Criteria A
70 % 25 cycles Criteria B
0 % 250 cycles Criteria B
Emission levels
CISPR 11 Instrument Class A, Group 1 Criteria A
Barberà del Vallès September 2017
Xavier Juncà - Product Manager
According to direcve 2012/19/EU, electronic equip-
ment must be recycled in a selecve and controlled
way at the end of its useful life.

FEMA ELECTRÓNICA . Series K . K40-CR
20
2. Output and control modules
The R1 module provides 1 relay output to to install at digital panel
meters from Series K, up to a maximum of 3 relays in a single meter.
Note : for more than three relays per instrument or larger relay den-
sity per module, see special modules R2, R4 and R6.
Conguraon is performed from the frontal keypad of the meter, by
seng the parameters at the alarm menu. Check the parameters of
at the alarm menu for full informaon.
Relay with 3 contacts (common, normally open, normally closed)
with up to 250 Vac switching voltage and 8 A.
Modules R1 can be ordered pre-installed into a Series K digital panel
meter, or standalone for delayed installaon, as they do not require
soldering or special conguraon.
2.1 Module R1
For more informaon : hp://fema.es/docs/4254_SERIES_M-K-S_
OPTIONS_manual_i.pdf
Type of relay 3 contact relay (NC, NO, common)
Current maximum 8 A per relay (resisve load)
Voltage maximum* 250 Vac connuous
Isolaon 3500 Ve
Type of terminal plug-in screw terminal, pitch 5.08 mm
Slots allowed ‘Opt.1’, ‘Opt.2’, ‘Opt.3’
Terminal A Common
Terminal B NO - Normally open
Terminal C NC - Normally closed
Power
Opt.2
Opt.1
Opt.3
A B C
A B C
Signal
A B C
The T1 module provides 1 transistor output to install at digital panel
meters from Series K, up to a maximum of 3 transistors in a single
meter.
Conguraon is performed from the frontal keypad of the meter, by
seng the parameters at the alarm menu. Check the parameters of
at the alarm menu for full informaon.
Transistor output is optoisolated, provides 2 terminals for connec-
on, and can switch up to 35 V and 50 mA.
Modules T1 can be ordered pre-installed into a Series K digital panel
meter, or standalone for delayed installaon, as they do not require
soldering or special conguraon.
2.2 Module T1
For more informaon : hp://fema.es/docs/4254_SERIES_M-K-S_
OPTIONS_manual_i.pdf
Type of output transistor
Max. voltage 35 Vdc
Max. current 50 mA
Isolaon 3500 Ve
Type of terminal plug-in screw terminal, pitch 5.08 mm
Slots allowed ‘Opt.1’, ‘Opt.2’, ‘Opt.3’
‘B’
‘A’
Schemac for T1 output
Power
Opt.2
Opt.1
Opt.3
A B C
A B C
Signal
A B C
This manual suits for next models
1
Table of contents
Other Fema Electronica Timer manuals