Table of Content
1. Overview..............................................................................3
2. Features...............................................................................3
2.1. Hardware Features........................................................3
2.2. Software Features..........................................................4
3. Typical Application..............................................................5
3.1. Point to Point Topology ..................................................5
3.2. Star Topology.................................................................6
4. Specification........................................................................6
4.1. Optical Port....................................................................6
4.2. E1 Port...........................................................................7
4.3. Ethernet Port..................................................................7
4.4. Phone Port.....................................................................7
4.5. Data Port........................................................................7
4.6. Management Port ..........................................................8
4.7. Power Supply.................................................................8
4.8. Operating Environment..................................................9
4.9. Device Size....................................................................9
5. Device Panel........................................................................9
5.1. 4/8E1 Multi-service Multiplexer, Standalone ..................9
5.2. 16E1 Multi-service Multiplexer.....................................13
5.3. Chassis of E1 Multi-service Multiplexer .......................18
5.4. 2*4E1 Multi-service Multiplexer Module.......................19
5.5. 4/8E1Multi-service Multiplexer Module ........................21
5.6. EOW Module................................................................23
5.7. POW Module................................................................27

4/8/16E1 Multiplexer User Manual V2.1
Beijing Fibridge Co., Ltd.
Tel: +8610-58858988 Fax: +8610-58858520 http://www.fibridge.com
- 2 -
6. Installation & Maintenance...............................................28
6.1. Install the Module and Chassis....................................28
6.2. Install the Standalone device .......................................29
6.3. Using Phone ................................................................30
6.4. Maintenance ................................................................31
7. Order Information..............................................................31
7.1. Model...........................................................................31
7.2. Part Number(P/N) of the standalone............................32
7.3. Part Number(P/N) of the Module..................................33
7.4. Part Number(P/N) of the Chassis.................................34

4/8/16E1 Multiplexer User Manual V2.1
Beijing Fibridge Co., Ltd.
Tel: +8610-58858988 Fax: +8610-58858520 http://www.fibridge.com
- 3 -
1. Overview
Multi-service Multiplexer combines digital multiplexing chip and
optical transmission technology. It is suitable for low capacity,
point-to-point application of remote transmission. The circuit part of
the equipment is fully digitized. The whole equipment is reliable,
stable, easy to install and maintain. It has good temperature and
voltage characteristics, complete alarm functions, one RS232/485
asynchronous interface and remote branch loop back functions. At
the same time, it can be monitored from Fi-View-MP management
software.
First of all, Multi-service Multiplexer can multiplex E1 (Up to
16E1) and Ethernet (2*10/100Mbps) signals in one fiber channel to
transmit. It is widely used in voice and data application field.
Sometimes, we use Multiplexer instead of Multi-service
Multiplexer. They have the same meaning.
2. Features
2.1. Hardware Features
zProviding up to 16 E1 channels and two optional 10/100Mbps
Ethernet channels
zDouble Optical ports optional for redundant backup,
auto-alternative
zWith special optical module, the device can support ALS

4/8/16E1 Multiplexer User Manual V2.1
Beijing Fibridge Co., Ltd.
Tel: +8610-58858988 Fax: +8610-58858520 http://www.fibridge.com
- 4 -
(Automatic Laser Shutdown) function
zE1 Line code: HDB3, compliant to G.703, G.823 and G.742.
zBoth the two Ethernet ports support 10/100Mbps
auto-detection, Full/Half Duplex auto-negotiation
zEthernet ports support VLAN and flow control
zComplete alarm functions
zProviding an RS232 /RS485 asynchronous interface
zSupporting the local/remote E1 loop back
zRemote branch loop back provided by software and hardware
zProviding RS232 and Ethernet port for management
zStandalone and chassis optional, 220VAC and –48VDC
optional
2.2. Software Features
zSupport local and remote management
zSupport Console, WEB and SNMP management
zRS-232 DB9 male management port and 10/100Mbps RJ45
Ethernet management port available
zShow details of system information, including chassis name,
location information, IP address, start-up time, software and
hardware version
zView & configure the working status of local and remote device,
including connection status, speed, half/full duplex mode, port
status
zSupport remote loop back function, helping to find out the line
fault conveniently
zA float window available for real-time alarm messages. And all
alarm messages can pop up to get more attention

4/8/16E1 Multiplexer User Manual V2.1
Beijing Fibridge Co., Ltd.
Tel: +8610-58858988 Fax: +8610-58858520 http://www.fibridge.com
- 5 -
zReset the system or a single local module or remote end
device via management software
zReset chassis to factory default
zShow the detailed information of power supply, including
AC/DC type and running status
zSupport firmware updating, with the update tool and new
version firmware file download from our website.
zProvide MIB file, make it easy to be integrated into the
third-party SNMP management software
zAdopt the centralized management style and the tree-view
catalogue, which can manage many sets of chassis at the
same time in one single window. Meantime, it’s very easy and
clear to manage all devices even if many chassis in one
window.
3. Typical Application
3.1. Point to Point Topology
Figure1 Point to Point Topology
4/8/16E1 10/100M 4/8/16E1
Multiplexe
r
Management
PC
Ethernet
Switch
Fibe
r
Multiplexe
r

4/8/16E1 Multiplexer User Manual V2.1
Beijing Fibridge Co., Ltd.
Tel: +8610-58858988 Fax: +8610-58858520 http://www.fibridge.com
- 6 -
3.2. Star Topology
F9-100M represents standalone of the Multi-service Multiplexer
Figure2 Star Topology
4. Specification
4.1. Optical Port
zBit rate: 150Mb/s+/-50ppm
zWavelength: 1310nm/1550nm
zOutput power: -11 to -4dBm
zSensitivity: better than -36dBm
zConnector: FC/SC/ST
zRedundant backup optical port optional
zAuto Laser shutdown (ALS) Optional

4/8/16E1 Multiplexer User Manual V2.1
Beijing Fibridge Co., Ltd.
Tel: +8610-58858988 Fax: +8610-58858520 http://www.fibridge.com
- 7 -
4.2. E1 Port
zData rate: 2048Kbps
zCode type: HDB3
zCompliant with G.703, G.704
zImpedance:75Ω(Unbalanced), 120ohm(Balanced)optional
zConnector: BNC(75Ω), RJ45(120ohm)
zJitter: Compliant with ITU-T G.742 and G.823
zUnframed mode
zNumbers: 4/8/16 optional
4.3. Ethernet Port
zCompatible with IEEE802.3, IEEE802.3u
zSpeed: 10/100MpbsMbps
zFull/Half duplex auto negotiating
zConnectors: RJ-45
zMDI/MDI-x auto negotiating
zEthernet port: 2 ports
4.4. Phone Port
zAvailable for daily telephone communication
z64Kbps PCM Code
zWhen picking up the local side, the remote side rings.
zOne side hung up, the other side sounds busy.
4.5. Data Port
zRS232/RS485 Protocol

4/8/16E1 Multiplexer User Manual V2.1
Beijing Fibridge Co., Ltd.
Tel: +8610-58858988 Fax: +8610-58858520 http://www.fibridge.com
- 8 -
zFor RS232, Bit rate: 4.8Kbps-115.2Kbps
zConnector: DB9, male, check table1 for the definition
Table1 Definition of the Data DB9
PIN 2 3 5 1, 4 6 7 8 9
Protocol RS232 RS485
Definition RX TX GND N.A. TX-
(Z)
TX+
(Y)
RX-
(B)
RX+
(A)
4.6. Management Port
zType: Console management
zProtocol: RS232, bit rate 9600bps or 19200bps
zConnector: DB9, male, check table2 for the definition
Table2 Definition of the Management DB9
PIN 2 3 5 Others
Definition RX TX GND N.A.
4.7. Power Supply
zInput voltage:
AC: 100V ~240V, 50/60Hz
DC: -48V
zPower Consumption :5W
6789
12345

4/8/16E1 Multiplexer User Manual V2.1
Beijing Fibridge Co., Ltd.
Tel: +8610-58858988 Fax: +8610-58858520 http://www.fibridge.com
- 9 -
4.8. Operating Environment
zTemperature:0℃—50℃
zHumidity:95%,no condensing
4.9. Device Size
z4/8E1 Standalone device
434mm (W) × 44mm (H) × 200mm (D)
z16E1 Standalone device
434mm (W) × 44mm (H) × 234mm (D)
zChassis size
19 inch (W) × 6U (H) × 300mm (D)
5. Device Panel
5.1. 4/8E1 Multi-service Multiplexer, Standalone
5.1.1. Front Panel of 4/8E1 Multi-service Multiplexer
Figure3 Front Panel of the 4/8E1 Multiplexer standalone
LEDs Buttons Phone Power Switch

4/8/16E1 Multiplexer User Manual V2.1
Beijing Fibridge Co., Ltd.
Tel: +8610-58858988 Fax: +8610-58858520 http://www.fibridge.com
- 10 -
5.1.2. Back Panel of 4/8E1 Multi-service Multiplexer
Figure4 Back Panel of the 4/8E1 Multiplexer standalone
5.1.3. LEDs Description of 4/8E1 Multi-service Multiplexer
Talbe3:LEDs description of the 4/8E1 Multiplexer standalone
LEDs Color Stat. Description
PWR Green ON Power Supply OK
ARL Red
ON/
Blink
ARL is on When local device has any alarm. ARL
blinks when remote device has alarm but no alarm
at local device.
OPTB Green ON Optical-B work state indicator.
OPTB is on when Optical-B works.
OPTA Green ON Optical-A work state indicator.
OPTA is on when Optical-A works.
NOPB Red ON NOPB is on when no optical signals is detected by
RX of Optical-B Port.
NOPA Red ON NOPA is on when no optical signals is detected by
RX of Optical-A Port.
Power IN Ethernet
Optical Port
5th -8th E1
1st-4th E1
Mgt
Data

4/8/16E1 Multiplexer User Manual V2.1
Beijing Fibridge Co., Ltd.
Tel: +8610-58858988 Fax: +8610-58858520 http://www.fibridge.com
- 11 -
LOF Red ON
LOF is on when Optical Line loses
synchronization. IE-3 and IE-6 Alarm are masked
when LOF alarm occurs.
IE-3 Red ON 1E-3 is on when optical line’s bit error rate is over
10-3.
IE-6 Red ON 1E-6 is on when optical line’s bit error rate is over
10-6.
LOS8-
LOS1 Red ON LOSx (x=1~8) is on When the relevant E1
Channel Signal loses.
LTR2 Green
ON/
Blink
Ethernet2 Link/TX/RX indicator. LTR2 is on when
the Ethernet2 port of the local device links
properly, LTR2 blinks when the Ethernet2 port of
the local device is transmitting or receiving Data.
FD2 Green ON
Ethernet2 Half/Full Duplex status indicator. FD2 is
on when the Ethernet2 port of the local device is
working at Full Duplex.
BT2 Green ON
Ethernet2 10M/100M bps speed indicator. BT2 is
on when the Ethernet2 port of the local device is
working at 100Mbps speed.
LTR1 Green
ON/
Blink
Ethernet1 Link/TX/RX indicator. LTR1 is on when
the Ethernet1 port of the local device links
properly, LTR 1blinks when the Ethernet1 port of
the local device is transmitting or receiving data.
FD1 Green ON
Ethernet1 Half/Full Duplex status indicator. FD1 is
on when the Ethernet1 port of the local device is
working at Full Duplex.
BT1 Green ON Ethernet1 10M/100M bps speed indicator. BT1 is
on when the Ethernet1 port of the local device is

4/8/16E1 Multiplexer User Manual V2.1
Beijing Fibridge Co., Ltd.
Tel: +8610-58858988 Fax: +8610-58858520 http://www.fibridge.com
- 12 -
working at 100Mbps speed.
Note: The LOF/1E-3/1E-6/LOS/LTR/SPD/FDX LEDs are corresponding to the
status of the remote device if the local/remote button is pressed down.
5.1.4. Button Description of 4/8E1 Multi-service Multiplexer
Table4 Panel Button Description of 4/8E1 Multiplexer
Type/Status Description
LOCAL
LOCAL/
REMOTE REMOTE
When the button of ‘Local/Remote’ is pressed
down as , this led shows the status of
remote device. Opposite, when up as ,
the led shows the status of local device.
ALARM
ALARM/
MUTE MUTE
When the button of ‘Alarm/Mute’ is pressed
down as , the alarm sound is mute.
Opposite, when up as , the device
sounds when any of the alarms occurs.
MASK Switch
Button
When press this button once, any of the current
E1 LOS Alarm will be masked, it looks
disappear. But new E1 LOS Alarm will still
make the relevant LOS LED on.
5.1.5. Interface Description of 4/8E1 Multi-service Multiplexer
Table5 Interface Description of 4/8E1 Multiplexer
Ports Description
PHONE Phone Connector

4/8/16E1 Multiplexer User Manual V2.1
Beijing Fibridge Co., Ltd.
Tel: +8610-58858988 Fax: +8610-58858520 http://www.fibridge.com
- 13 -
POWER AC/DC Power Input
ETH-2 The 2nd Ethernet port, RJ45, 10/100Mbps, Half/Full Duplex
EHT-1 The 1st Ethernet port, RJ45, 10/100Mbps, Half/Full Duplex
OPTB Optical B, for backup function
OPTA Optical A
E1 8-5 5th ~8th E1 Channel, DB37 Connector, connected by an adapter
E1 4-1 1st ~4th E1 Channel, DB37 Connector, connected by an adapter
Mgt Management Console port, RS232, DB9 Connector
Data RS232/RS485 Data port, DB9 Connector
Note: Above description is include all the ports. The ordered device maybe
haven’t some of the ports, such as optical B, 5th~8th E1 channel, etc.
5.2. 16E1 Multi-service Multiplexer
5.2.1. Front Panel of 16E1 Multi-service Multiplexer
\
Figure5 Front Panel of the 16E1 Multiplexer standalone
LEDs Buttons Power Switch
Optical Ports
Ethernet
DIP Switch Phone

4/8/16E1 Multiplexer User Manual V2.1
Beijing Fibridge Co., Ltd.
Tel: +8610-58858988 Fax: +8610-58858520 http://www.fibridge.com
- 14 -
5.2.2. Back Panel of 16E1 Multiplexer
Figure6 Back Panel of the 16E1 Multiplexer standalone
Note: There are two types of Modules for the E1 channel. One is
8*BNC Module for 75ohm impedance, the other is 8*RJ45 Module
for 120ohm impedance. They are exchangeable.
5.2.3. LEDs of 16E1 Multi-service Multiplexer Description
Table6: LEDs Description of the 16E1 Multiplexer
LEDs Color Stat. Description
PWR Green ON Power Supply OK
ARL Red ON/
Blink
ARL is on When local device has any alarm.
ARL blinks when remote device has alarm
but no alarm at local device.
LOS16-
LOS1 Red ON
LOSx (x=1~16) is on When the relevant E1
Channel Signal loses.
LTR1 Yellow ON/
Blink
Ethernet1 Link/TX/RX indicator. LTR1 is on
when the Ethernet1 port of the local device
links properly, LTR 1blinks when the
Ethernet1 port of the local device acts, that
is, transmitting or receiving.
Power Input 1st – 8th E1 Channel Card9th–16th E1 Channel Card

4/8/16E1 Multiplexer User Manual V2.1
Beijing Fibridge Co., Ltd.
Tel: +8610-58858988 Fax: +8610-58858520 http://www.fibridge.com
- 15 -
LTR2 Yellow ON/
Blink
Ethernet2 Link/TX/RX indicator. LTR2 is on
when the Ethernet2 port of the local device
links properly, LTR2 blinks when the
Ethernet2 port of the local device acts, that
is, transmitting or receiving.
SPD1 Green ON
Ethernet1 10M/100M bps speed indicator.
BT1 is on when the Ethernet1 port of the
local device is working at 100Mbps speed.
SPD2 Green ON
Ethernet2 10M/100M bps speed indicator.
BT2 is on when the Ethernet2 port of the
local device is working at 100Mbps speed.
FDX1 Green ON
Ethernet1 Half/Full Duplex status indicator.
FD1 is on when the Ethernet1 port of the
local device is working at Full Duplex.
FDX2 Green ON
Ethernet2 Half/Full Duplex status indicator.
FD2 is on when the Ethernet2 port of the
local device is working at Full Duplex.
WORKA Green ON Optical-A work state indicator.
OPTA is on when Optical-A works.
WORKB Green ON Optical-B work state indicator.
OPTB is on when Optical-B works.
NOPA Red ON
NOPA is on when no optical signals is
detected by RX of Optical-A Port.
NOPB Red ON
NOPB is on when no optical signals is
detected by RX of Optical-B Port.
LOFA Red ON
LOFA is on when Optical-A Line loses
synchronization. IE-3 and IE-6 Alarm are

4/8/16E1 Multiplexer User Manual V2.1
Beijing Fibridge Co., Ltd.
Tel: +8610-58858988 Fax: +8610-58858520 http://www.fibridge.com
- 16 -
masked when LOFAalarm occurs.
LOFB Red ON
LOFB is on when Optical-B Line loses
synchronization. IE-3 and IE-6 Alarm are
masked when LOFB alarm occurs.
IE-3A Red ON
1E-3A is on when optical-A line’s bit error
rate is over 10-3.
IE-3B Red ON
1E-3B is on when optical-B line’s bit error
rate is over 10-3.
IE-6A Red ON
1E-6A is on when optical-A line’s bit error
rate is over 10-6.
IE-6B Red ON
1E-6B is on when optical-B line’s bit error
rate is over 10-6.
Note: The Work / NOP / LOF / 1E-3 / 1E-6 / LOS / LTR / SPD / FDX LEDs will
show the status of the remote device if the local/remote button is pressed
down.
5.2.4. DIP Switch SET of 16E1 Multi-service Multiplexer
Table7 DIP Switch Description of the 16E1 Multiplexer
X ON ON OFF OFF OFF
Bit1,2 Optical port
Selection Forced Port A Forced Port B A/B Auto-select
Bit3 E1Loop back ON: Local loop enable, OFF: Remote loop enable
Bit4 ALS setting ON: ALS Enable, OFF: ALS Disable
Note: X means both ON and OFF are OK.

4/8/16E1 Multiplexer User Manual V2.1
Beijing Fibridge Co., Ltd.
Tel: +8610-58858988 Fax: +8610-58858520 http://www.fibridge.com
- 17 -
5.2.5. Button Description of 16E1 Multi-service Multiplexer
Table8: Description for the Button of 16E1 Multiplexer
Type/Status Description
LOCAL
LOCAL/
REMOTE REMOTE
When pressed down as , this led shows
the status of remote device. When Pressed up
as , the led shows the status of local
device.
ALARM
ALARM/
MUTE MUTE
When pressed down as , the alarm sound
is mute. When pressed up as , the device
sounds when any of the alarms occurs.
MASK Switch
Button
When press this button once, any of the current
E1 LOS Alarm will be masked, it looks disappear.
But new E1 LOS Alarm will still make the relevant
LOS LED on.
5.2.6. Interface Description of 16E1 Multi-service Multiplexer
Table9 Interface Description of 16E1 Multiplexer
Port Description
PHONE Phone Connector
ETH-2 The 2nd Ethernet port, RJ45, 10/100Mbps, Half/Full Duplex
EHT-1 The 1st Ethernet port, RJ45, 10/100Mbps, Half/Full Duplex
OPTB Optical B, for backup function

4/8/16E1 Multiplexer User Manual V2.1
Beijing Fibridge Co., Ltd.
Tel: +8610-58858988 Fax: +8610-58858520 http://www.fibridge.com
- 18 -
OPTA Optical A
Power AC/DC Power Input
E1 16-9
E1 8-1
One card which can be installed into the standalone box,
75ohm/120ohm Optional
Mgt Management Console port, RS232, DB9 Connector
Data RS232/RS485 Data port, DB9 Connector
Note: Above description is include all the ports. The ordered device maybe
haven’t some of the ports, such as optical B, ETH1& ETH2 etc.
5.3. Chassis of E1 Multi-service Multiplexer
5.3.1. Front View of the Chassis
Figure7: Slots types distributing
As shown in the above figure, there are 14 slots chassis in the
device. These 14 slots are dividing into three parts: the leftmost slot
P
W
R
P
D
H
12
/
P
W
R
P
D
H
11
P
D
H
10
P
D
H
8
E
O
W
P
D
H
1
P
D
H
2
P
D
H
3
P
D
H
4
P
D
H
5
P
D
H
6
P
D
H
7
P
D
H
9

4/8/16E1 Multiplexer User Manual V2.1
Beijing Fibridge Co., Ltd.
Tel: +8610-58858988 Fax: +8610-58858520 http://www.fibridge.com
- 19 -
is for EOW, the rightmost slot is for 220VAC PWR, the other 12
slots is for Multi-service Multiplexer Module. The 12th Multi-service
Multiplexer Module can also be installed for 220VAC PWR Module.
For -48VDC power input, user needn’t install any Power
Module. User only need to connect the -48V power input connector
to the -48VDC power source.
5.3.2. Back View of the Chassis
Figure8: Back Panel View of the Chassis
5.4. 2*4E1 Multi-service Multiplexer Module
For 2*4E1 Multi-service Multiplexer Module, one module has two
independent 4E1 Multi-service Multiplexer device. They are the
same. The two optical port is independent.
~220VAC
Power Input
DB37 to
8*BNC Adapter
-48V
POWERPUSE -48V Power Switch
-48V Power Input
Table of contents
Popular Multiplexer manuals by other brands

Beijing Huahuan Electronics
Beijing Huahuan Electronics H0EL-EthMux V8 user manual

Panasonic
Panasonic WJ-FS309 operating instructions

ADTRAN
ADTRAN Total Access OC-3 L3 Installation and maintenance practice

ShipModul
ShipModul MiniPlex-2USB NMEA-0183 manual

Telecast
Telecast Adder AES-8 instruction manual

Focal
Focal 907 user guide

Dormakaba
Dormakaba Multiplexer installation guide

Tektronix
Tektronix KEITHLEY 7700 Instructions for use

Juniper
Juniper TCX1000-RDM20 Hardware guide

ShipModul
ShipModul MiniPlex-41USB NMEA-0183 manual

Vetra
Vetra MegaMux USB- 882 Series User instructions

ArcVision Technology
ArcVision Technology ARC-19509 user manual