flamco VHW 260 User manual

Flamco VHW 260
Sanitary heat pump
-10 °C to 35° C
Flamco VHW 260
Contents(adaptinownlanguage)
ENG Installation and user manual 3

2
BE Flamco Belux
J. Van Elewijckstraat 59
B -1853 Grimbergen
+32 2 476 01 01 info@amco.be
CH Flamco AG
Fännring 1
6403 Küssnacht
+41 41 854 30 50 info@amco.ch
CZ Flamco CZ
Evropská 423/178
160 00 Praha 6
+420 602 200 569 info@amco.cz
DE Flamco GmbH
Steinbrink 3
42555 Velbert
+49 2052 887 04 info@amco.de
DK Flamco
Tonsbakken 16-18
DK-2740 Skovlunde
+45 44 94 02 07 info@amco.dk
EE Flamco Baltic
Löötsa 6
114 15 Tallin
+ 372 56 88 38 38 info@amco.ee
FI Flamco Finland
Ritakuja1
01740 Vantaa
+ 358 10 320 99 90 info@amco.
FR Flamco s.a.r.l.
BP 77173
95056 CERGY-PONTOISE cedex
+33 1 34 21 91 91 info@amco.fr
HU Flamco Kft.
(A Pest Megyei Bíróság mint Cégbíróság.
Cg.13-09-136479)
H-2330Dunaharaszti,
Jedlik Ányos út 25
+36 24 52 61 31 info@amco.hu
NL Flamco B.V.
Postbus 502
3750 GM Bunschoten
+31 33 299 75 00 support@amco.nl
PL FlamcoSp.zo.o.
ul. Akacjowa 4
62-002 Suchy Las
+48 616 5659 55 info@amco.pl
SE Flamco Sverige
Kungsgatan 14
541 31 Skövde
+46 500 42 89 95 vvs@amco.se
UAE Flamco Middle East
P.O. Box 262636
JebelAli,Dubai
+971 4 881 95 40 info@amco-gulf.com
UK Flamco Limited
Washway Lane- St Helens
Merseyside WA10 6PB
+44 1744 74 47 44 info@amco.co.uk

3
ENG
Table of content
1. APPLICATION 4
1.1 GENERAL 4
1.2 TECHNICAL SPECIFICATIONS 5
1.3 APPLIANCE LAYOUT 6
1.4 WIRING DIAGRAM 7
1.5 STORAGE AND TRANSPORT 8
1.6 SCOPE OF SUPPLY 8
1.7 OPERATING PRINCIPLE OF THE VENTILATION HEAT PUMP WATER HEATER 10
2. SAFETY 11
2.1 SAFETY,CONTROLANDPROTECTIONDEVICES 12
2.1.1 HIGH PRESSURE SWITCH 12
2.1.2 HIGH LIMIT SAFETY CUT-OUT 12
2.1.3 TEMPERATURE SENSOR FOR AIR INLET 12
3. INSTALLATION 13
3.1 INSTALLATION LOCATION 13
3.2 CONNECTING THE CONDENSATE HOSE 14
3.3 CONNECTING THE DUCTS 14
3.4 FILLING THE CYLINDER 15
3.4.1 WATER QUALITY 15
4. USE 16
4.1 FLOWCHART MENU 16
4.2 OPERATION 17
4.3 OPERATION MODES 17
4.4 SETTING THE DOMESTIC HOT WATER TEMPERATURE 17
4.5 MAIN MENU 18
4.6 “PROG” SUBMENU - OPERATING MODES 18
4.6.1 “MANUAL” OPERATING MODE 18
4.6.2 “P1”,“P2”AND“P3”OPERATINGMODES 19
4.6.3 “FULL” OPERATING MODE 19
4.6.4 “OFF” OPERATING MODE 19
4.7 “MODE” SUBMENU - HEATING MODE 19
4.7.1 ELECTRICAL HEATING MODE 20
4.7.2 “HEAT PUMP” OPERATING MODE 20
4.7.3 “COMBI” OPERATING MODE 20
4.8 “SET” SUBMENU - SETTINGS 20
4.8.1 DATE-SETTINGTHETEMPERATUREUNIT,DATE,TIMEANDDAYOFTHEWEEK 21
4.8.2 PROG - PROGRAMMING OF THE OPERATING TIMES 21
4.8.3 “LEG” - AUTOMATIC THERMAL DISINFECTION 23
4.8.4 « FAN » - FANSPEED 24
4.8.5 « DUCT » - USE OF DUCTS 24
4.8.6 “PURG” - DRAIN 24
4.8.7 “FSET” - DEFAULT SETTINGS 24
4.8.8 “INFO” SUBMENU – INFORMATION 25
4.9 FAULT DIAGNOSIS 25
4.10 DEFAULT SETTINGS 25
4.11 FAULTS DISPLAY 26
4.11.1 DISPLAY 26
5. MAINTENANCE (YEARLY CHECK) 27
5.1 GENERAL INSPECTIONS 27
5.2 CLEANING 27
5.3 CONDENSATE PIPE 27
5.4 REFRIGERANT CIRCUIT 27
5.5 HIGH LIMIT SAFETY CUT-OUT 28
5.6 DRAINING THE CYLINDER 28
5.7 “SERVICE” MENU 28
6. DISMANTLING, RECYCLING AND ENVIRONMENTAL PROTECTION 29
ENG Installationandusermanual

4
ENG Installationandusermanual
1. APPLICATION
1.1 GENERAL
The appliance may only be used for DHW (Domestic Hot Water) heating. Using the boiler for any other purpose
will be considered incorrect use. Flamco accepts no liability for any damage resulting from such use.
The appliance is not suitable for commercial or industrial applications. It is approved for household use only.
DeFLVHW260isaheatpumpforDHWheatingwiththefollowingspecications:
•(H) CFC-free polyurethane hard foam isolated (70 mm) vessel of stainless steel (1.4521);
•Indirect heating of DHW;
•Refrigerant R134a;
•Temperature DHW adjustable between 30° C to 70° C;
•Automatically switch-off heat pump at air temperature between -10°C to 35°C;
•Easy serviceable;
•NoFluorgasescerticationneededforchangingthecompleteheatpumpassembly
Please read the installation instructions before installing the appliance!
Please read the operating instructions before commissioning the appliance!
Please observe the safety instructions in the operating instructions!
Theinstallationlocationmustmeettherequirementsforsufcientventilation!
Installation must only be carried out by an authorized contractor!

5
ENG
1.2 TECHNICAL SPECIFICATIONS
Heatingoutput–inaccordancewithEN255-3,airtemperature20°C,
heating water from 15°C to 45°C.
Unit VHW 260
Output kW 1,7*
Total heating output (including electric booster heater) kW 3,7*
COP - 4,3*
Standby energy consumption kW/day 0,74*
Heatingoutput–inaccordancewith16147,XLcycle,airtemperature
15°C,heatingwaterfrom10°Cto54°C.
VHW 260
COP - 3,2*
Heating time (HP only) - 8h48*
Standby energy consumption kW/day 1,08*
Heatingoutput–inaccordancewith16147,XLcycle,airtemperature
7°C,heatingwaterfrom10°Cto54°C.
VHW 260
COP - 2,79*
Heating time (HP only) - 10h38*
Standby energy consumption kW/day 0,97*
General specifications VHW 260
Description - Air/water heat
pump for DHW
use
Motor type Fan - DC
Adjustment range sp1/sp2 (without pipe work) m3/h 380/490
Control ventilator Adjustable by HMI
(2 speed)
IP-class - 21
Refrigerant/mass -/gram R134a/400
Operating temperature °C -10 … +35
Maximum pressure compressor bar 27
Reservoir capacity liter 250
Maximum pressure vessel bar 10
Sound level (distance 1 meter-380m3/h) dB(A) 50*
Power supply V/Hz 230 /50
Max. power consumption Watt 2600
Nominal current (HP-only/HP + immersion heater) A 2,6/11,3
Start-up current A 13,5max.
Fuse rating A 16
Electrical immersion heater kW 2
Plug type - Type E
Labels and markings - CE/LCIE*/WEEE/
NF*/RoHS/
REACH/ACS
*allthesevaluescanonlybereleasedordefinedafterthemeasurementsdonebyLCIE.

6
ENG Installationandusermanual
1.3 APPLIANCE LAYOUT
1
2
6 7 8
12
11
1
17
15
10
16
9
13 14
2
5
4
3
[1] Water inlet – G3/4”
[2] Water outlet – G3/4”
[3] Thermal insulation
[4] Water inlet to condenser
[5] Water outlet from condenser
[6] Fan
[7] Evaporator
[8] Condenser (gas/water heat exchanger)
[9] Compressor
[10] Sensor pocket for DHW temperature sensor
[11] Electrical backup immersion heater
[12] Adjustable feet (3x)
[13] Air outlet aperture
[14] Air inlet aperture
[15] Condensate outlet
[16] Circulation pump
[17] Front protective covering

7
ENG
1.4 WIRING DIAGRAM
[1] NTC temperature sensor for air inlet
Thisballonandcomponentisaddedinthispicture,notinEPS
[2] NTC temperature sensor
[3] NTC temperature sensor in water inlet
[4] Power cable
[5] High Pressure Switch
[6] Electrical capacitor for compressor
[7] Compressor
[8] High limit safety cut-out for compressor
[9] Circulation pump
[10] Fan
[11] Immersion heater
[12] High-limit safety cut-out for immersion heater
[13] Electronics box
[14] NTC temperature sensor (evaporator plates)
[15] Electrical capacitor for fan start
[16] Electrical capacitor for fan speed
[17] Defrost valve

8
ENG Installationandusermanual
1.5 STORAGE AND TRANSPORT
WARNING:Transportdamage!
•Take care when handling the appliance.
•Toavoiddroppinganddamagingtheappliance,donotpivotit.
NOTICE:Transportdamage!
•Toavoidtransportdamage,donotremovetheprotectivepackaging.Wait
until the appliance is at the installation location to remove the protective
packaging.
•Transport and set down the appliance carefully. Jerky movements can
damagethecomponents,thevesselandtheirconnectionsortheexternal
casing.
•Use suitable means of transport to bring the appliance to theinstallation
location(specialcar,pallettruck,etc).
General information
The appliance is delivered on a single pallet and is protected against transport
damage by special packaging. The appliance must be stored and transported
vertically in its original packaging1and the cylinder must be empty. Ambient
temperatures of -20 °C to +60 °C are permissible for storage and transport.
This device is not intended for use by persons (including children) with
physical,sensoryormentaldisability,ofbypersonswithlackexperienceorknowledge,unlesstheyhavereceived
from a person in charge of their safety adequate supervision or preliminary instructions on how to use the device.
Dare must be taken at all times to keep children from playing with the device.
1.6 SCOPE OF SUPPLY
1-Flamco VHW 260
2-Set of documents
3-Condensate drain and hose pillar
1 Horizontaltransportationispermittedovershortdistances,providedthattheconditionsdescribedabovearefulfilled.
Flamco VHW 260
Sanitary heat pump
-10 °C to 35° C
Flamco VHW 260
Contents(adaptinownlanguage)
ENG Installation and user manual 3
2
3
1

9
ENG
Data plate
The data plate is located on the rear side of the appliance.
1.6.1 ACCESSORIES
This table need to be determined.
Description Article number
Safety valve 12450
…. ….
…. ….
…. ….
Dimensions

10
ENG Installationandusermanual
1.7 OPERATING PRINCIPLE OF THE VENTILATION HEAT PUMP WATER HEATER
The Ventilation Heat Pump Water heater consists
ofanexpansionvalve(1),anairheatexchanger(2),
a compressor (3) and a water heat exchanger (4).
A refrigerant circulates in the closed system (5). In
theexpansionvalve,thepressureandtemperature
oftherefrigerantarelowered,whichbecomes
vaporous. It extracts heat from the air (6) via the air
heat exchanger. The vapour is then compressed
by the compressor. This increases the pressure
and the temperature (7). The heat is transferred to
the water via the water heat exchanger (8). And the
cycle begins anew. It is therefore possible to heat
water with a low temperature of 10 ºC to domestic
hot water with a temperature of 60 ºC. This makes
it possible to create four parts of energy (heat) from
just one part of energy (electricity).

11
ENG
2. SAFETY
Installation
•Theappliancemayonlybeinstalledbyanauthorizedcontractor.
•Donotinstalltheapplianceinthefollowinglocations:
–Outside
–o in locations which promote corrosion
–o in locations with a risk of frost
–o in locations where there is a risk of explosion.
Checkifamaximumtemperatureisspeciedbylocal,stateorfederalregulationsisrequired.Ifso,atempering
valveshallbeinstalledattheDHWoutlet!
Wait until the appliance is at the installation location to remove it from its packaging!
•All water connections must be checked for tightness before the appliance is connected to the power.
•Observe minimum clearances
•The electrical connection must comply with the local applicable regulations.
•Connecttheappliancetoanindependent,earthedpowersource.
•Install a safety valve at the appliance’s cold water inlet.
•The drain line from the safety valve must be laid in a frost-free location. It must remain open to the atmosphere and
always be kept in a sloped position.
•Minimumandmaximumwatertemperatures:3°C/80°C
•Minimum/maximumwaterpressure:0.2bar/2barbelowthevalueoftheinstalledsafetyvalve
Risk of scalding at the hot water draw-off points
•Whentheapplianceisinoperation,temperaturesinexcessof70°Ccanoccur.Tolimitthetemperatureatthetap,
install a thermal DHW tempering valve.
Service
•The end customer is responsible for safety and environmental compatibility during installation and service work.
•Theappliancemayonlybeservicedbyanauthorizedcontractor.
•Isolate the appliance from the power supply before performing any service work.
Service and maintenance
•Maintenancemayonlybecarriedoutbyanauthorizedcontractor.Faultymaintenancemayposeadangertothe
user and cause malfunctions in the appliance.
•Use only original spare parts.
•Haveanauthorizedcontractorperformanannualinspectionandservicetheapplianceasneeded.
•Anyworkinvolvingcoolinggasmayonlybecarriedoutbyqualiedcontractors.
•Empty cylinders.
•We recommend that you arrange a maintenance and inspection contract with the manufacturer.
Room/inlet air
Keeptheinletairfreeofcontaminants.Itmustnotcontainanyofthefollowingsubstances:
•corrosivesubstances(ammonia,sulphur,halogenproducts,chlorine,solvents)
•fatty or explosive substances
•aerosol concentrations
No other air inlet systems may be connected to the fan.
Refrigerant
•Please observe the applicable environmental regulations when using and reusing refrigerant. Do not release it into
theenvironment!UsetherefrigerantR134a.Itisnonammableanddoesnotdamagetheozonelayer.
•Beforeworkingonpartsoftherefrigerantcircuit,removetherefrigerantforsafetyreasons.
PleasenotethatHFC-134aandPAG-ÖLareusedduringservicework.Thisisachlorouorocarbonandisratedwitha
greenhouse potential of 1300 in the Kyoto Protocol.
Instructions to the customer
•Explain to the customer how the appliance works and how to operate it.
•Advisethecustomerthathe/shemustnotmakeanymodicationstotheapplianceorcarryoutanyrepairs on it.

12
ENG Installationandusermanual
Safety of electrical appliances for domestic use and similar purposes
ThefollowingrequirementsapplyinaccordancewithEN60335-1inordertopreventhazardsfromoccurring
whenusingelectricalappliances:“Thisappliancemaybeoperatedbychildrenaged8oroverandbypeoplewith
fullphysical,sensoryandmentalcapabilitieswhohavethenecessarytrainingandexperiencetousethistypeof
appliance. They must be supervised or instructed on how to use the appliance safely and on the associated risks.
Children must not play with the appliance. Children must not clean or service the appliance without supervision.”
“Damagedpowercablesmustbereplacedbythemanufacturer,theservicedepartmentoraqualiedcontractorin
ordertopreventhazards.”
2.1 SAFETY, CONTROL AND PROTECTION DEVICES
2.1.1 HIGH PRESSURE SWITCH
Iftheoperatingpressureisoutsideoftherecommendedrange,thepressureswitchswitchesofftheapplianceand
displays a fault.
2.1.2 HIGH LIMIT SAFETY CUT-OUT
The high limit safety cut-out ensures that the water temperature in the cylinder does not exceed the prescribed limit.
Ifthetemperaturelimitisexceeded,theDHWheatingshutsdown.Theresetisperformedmanuallybyacertied
contractor.
2.1.3 TEMPERATURE SENSOR FOR AIR INLET
The temperature sensor measures the temperature of the inlet air in the evaporator. If the measured value is outside
theoperatingtemperaturerange,DHWheatingautomaticallyswitchesfromthe“Combi”operatingmodeto“Electric
boosterheater”.Iftheapplianceisinthe“Heatpump”operatingmode,DHWheatingisinterrupteduntilthe
temperature returns to within the permissible range.

13
ENG
3. INSTALLATION
•Theappliancemayonlybeinstalledbyanauthorizedcontractor.
•The heat pump installation must follow the applicable regulations.
•Check that all pipe connections are intact and have not shaken loose during transportation.
NOTICE:Refrigerantleak!
•Onlyauthorizedcontractorsarepermittedtomaintainandrepairtherefrigerantcircuit.
3.1 INSTALLATION LOCATION
Pleasenotethefollowingwhenchoosingtheinstallationlocation:
•Theappliancemustbeinstalledinadry,frost-freeroom.The
supply air temperature must be between -10 °C and 35 °C in
ordertooptimizetheapplianceperformance.
•Theappliancemustbeinstalledonasufcientlystrongandlevel
surface.
•The air outlet and air inlet must not be in locations where there is
ariskofexplosioncausebygas,steamordust.
•Ensure that condensate drains correctly.
•The surface below the appliance must be strong enough (the
applianceweighsabout400kgwhenthecylinderislled,with
the weight distributed equally over its 3 adjustable feet).
Iftheapplianceonlyhasoneduct(inletoroutletduct),itsoperation
may create negative or positive pressure in the installation room. If
otherburnersarealreadyinstalledinthesameplace,pleasebearin
mind that the appliance requires a clearance of at least 220 cm2 for
the air inlet and outlet in order to operate correctly.
Note:Theclearanceof220cm2isrequiredforthecorrect
functioning of the heat pump only.
To ensure faultless operation and easy access to all components
andconnectionsforserviceandmaintenance,maintainthe
minimumclearancesspeciedingure1.
Installing the appliance
•Remove external protective packaging.
•Lifttheappliancefromitspalletandpositionitonitsnalplinth.
Watch out for damaging the metal hood of the HP-unit. Only lift at
thevesselpart!
•Tocorrectlyaligntheapplianceattheinstallationlocation,adjust
the height of the adjustable feet.
•Assurecorrectpositioningofalltemperaturesensors,seegure
2 and 3.
To ensure that the system operates faultlessly and the condensate
drainscorrectly,theappliancemustbealignedvertically.The
appliancemusttilt1°,intothedirectionofthecondensatedrain.
NOTICE:Possibledamagetoexternalcasing!
•Do not tilt the appliance on his feet more than 20°.
Fig. 1
Fig. 2
Fig. 3

14
ENG Installationandusermanual
3.2 CONNECTING THE CONDENSATE HOSE
Damagetotheappliance!Connectthecondensatehosetothe
condensate drain before installing the part.
•Donotbendthecondensatehose!
Thecondensateisdrainedontherearsideoftheappliance,
seegure4.
•Connect the condensate hose to the condensate drain (1)
•Connect the condensate hose to the collection area.
•Drain off condensate via a siphon drain (2)
Don’tdisconnectthecondensatehosefromthecondensatedrain,
thiswilldamagetheconnectioninthefoam!
3.3 CONNECTING THE DUCTS
Theairinletcanbelocatedintheinstallationroom,inadifferentroomoroutside.Inthelattertwocases,airinlet
ducts must be installed. If ducts are used select “ducts on”. (see 4.8.5)
Toensuremaximumapplianceperformanceandtopreventcondensationformingontheexternalductwalls,use
thermally and acoustically insulated ducts.
Whenchoosingaroomfortheairinlet,observetheaverageairtemperatureandrequiredairowrate.Inorderto
minimizeairresistance,laytheairinletandoutletducts(Ø160mm)asstraightaspossible.
Thelength(Leq)oftheairinletandoutletductsmustnotexceedthefollowingvalues:
•30m at fan speed 1 (SP1)
•30m – 60m at fan speed 2 (SP2)
Air inlet Air outlet
0,5mduct 0,5m
1 m duct 1,0m
2m duct 2,0m
10 m hose 19,0m
45° elbow 0,9m
90° elbow 2,0m
90° flexible curve 2,3m
Weather grille 8 m 4 m
Roof output 7 m 4 m
To ensure that condensate forming in the air inlet and air outlet
ductsdrainsfromtheappliance:
•Install air ducts at a slight angle to the air inlet and air outlet
apertures on the top side of the appliance.
Always use insulated pipes to prevent condensate at the air inlet
and the air outlet. By the use of outside air condensate can occur.
It’s recommended to use SP2 if ducts are used with a high
resistance. (To select SP2 see 4.8.4)
Please note that a high ventilator volume results in a higher sound
level.
Fig. 4

15
ENG
3.4 FILLING THE CYLINDER
Damagetotheappliance!Priortocommissioningtheappliance,ll
thecylinderwithwaterandbleedthesystemifnecessary.
Filling the cylinder
•Open the water outlet valve and at least one hot water tap.
•Openthewaterinletvalveonthecylinder.Thecylinderislled.
•Donotclosethehotwatertapsuntilthewaterowssteadilyand
is free from air bubbles.
•Connect the appliance to the power supply via a separate socket
with an earth connection.
•Call up the “Purg” function. (see 4.8.6)
•Set the selector switch on the DHW pump to “III”. (Fig.5(1))
CAUTION:Riskofscalding!Ensurethatdrainingwaterfromtheair
vent screw presents no risk to people or property.
Openthedrainscrewontheheatingpump(Fig.5(2))untilthewaterowssteadilyandwithoutairbubbles.
•Close the drain screw on the heating pump.
•Waitaround5minutesuntilthe“Purg”operatingmodehasnished.
•Settheselectorswitchontheheatingpumpto“I”.Theprocessofdrainingandllingthecylinderiscomplete.
Ifthefaultcode“E09”appearsonthedisplayafterafewminutes,proceedasfollows:
•Clear the fault
•Rellmanually.
3.4.1 WATER QUALITY
Waterqualityvaries,inordertoensurealongandtroublefreelifetheheatpumpthefollowingvaluesshouldnotbe
exceeded.
Total hardness 200 p.p.m.
Chloride 250 p.p.m.
Sulphate 250 p.p.m.
Magnesium 10 p.p.m.
Sodium 150 p.p.m.
pH Min 6.5 and Max 8.5
Inadequate water quality or contaminated water can damage the appliance. Scaling is more important at higher
watertemperature.Incaseofwaterhardnessabove600mg/l,theLangeliersaturationindexmustbedeterminedto
evaluate the necessity for water treatment.
Check the guideline 98/83/EG for the minimal requirements about potable water.
Note:Inregionswithmorecorrosivewater,safetymeasures(lter,etc.)mustbetaken.Therstinspectionmust
always take place 6 months after installation.
Fig. 5

16
ENG Installationandusermanual
4. USE
1. Display
2. Mode Selector keys
4.1 FLOWCHART MENU

17
ENG
4.2 OPERATION
1. Electrical heating mode
2. DHW heating by heat pump
4. Information
5. Input of adjustable parameters
6. Error display
7. Service menu selection
8. days of the week
9. “Auto/Man” operation
10. ON/OFF indicator
11. “Prog” menu selection
12. Setting the hour
13. Runtime
14. Power consumption
15. Code for cylinder temperature sensors
16. Frost protection
Refreshnumbers,tableandpicture.
4.3 OPERATION MODES
“auto”symbolisdisplayed•operatingtimesasset(P1,P2orP3).
“man“symbolisdisplayed•Continuousoperation(24h/7days)withouttimesettingorin“Full”operating
mode.
4.4 SETTING THE DOMESTIC HOT WATER TEMPERATURE
The water temperature is set to 50 °C at the factory. This value can be changed
by pressing the “+” or “-“ button to set the desired value. Pres the “ OK” button
toconrmthesetting.Thesetvalueashesunitthesettingisconrmed.Ifthe
settingisnotconrmedwithin10seconds,thepreviouslysetvalueisretained.
Oncethetemperaturehasbeenset,thedisplayindicatesthewatertemperaturein
the cylinder.

18
ENG Installationandusermanual
4.5 MAIN MENU
Callingupthemainmenu:
Press and hold the “Menu button for max. 3 seconds. Once you have called
upthemainmenu,youcanselectthefollowingmenus/submenus:
•Prog - Operating modes
–Manual
–P1
–P2
–P3
–Full
–Off
•Mode - Heat types
–“Electrical” operating mode
–“Heat pump” mode
–“Combi” operating
•Set settings
–Date
–Prog- Programming of the operating times
–Leg – Legionella program
–Fan - Fan speed
–Duct – use of ducts
–Purg – Drain
–Fset – Default setting
•Info
Usethe“+”or“-“buttontoselecttherequiredmenu.Conrmbypressing“ok”.Toswitchtothepreviousmenupress
the “Menu” button or do not press any button for 15 seconds.
4.6 “PROG” SUBMENU - OPERATING MODES
You can set 7 different operating times in the “Prog” submenu.
•Manual
•P1
•P2
•P3
•Full
•Off
4.6.1 “MANUAL” OPERATING MODE
Selecting this operating mode puts the appliance into continuous operation in
order to keep the temperature at the set value for a longer period of time. The
heat appliance can be set in the main menu using the “Mode” function.

19
ENG
4.6.2 “P1”,“P2”AND“P3”OPERATINGMODES
“P1” operating mode selecting this menu causes the appliance to run according to the factory-set operating times.
“P2” and “P3” operating modes Selecting this menu causes the appliance to run according to the user-set operating
times.
4.6.3 “FULL” OPERATING MODE
Inthisoperatingmode,twoheatappliancesareusedatthesametime:the
heat pump and the electric booster heater.
The appliance performance decreases in “Full” operating mode. For this
reason,itmustonlybeusedwhenthewatertemperatureneedstobe
increased rapidly.
The water temperature can be set to between 30 °C and 70 °C.
Both heat appliances are used at the same time until the desired temperature
is reached. Only the electric booster heater is used at temperatures above 60
°C. The display shows “Full” until the desired temperature is reached.
AssoonasthesetDHWtemperatureisreached,theapplianceswitchesfrom
the “Full” operating mode back to the previously set operating mode. “Quick”
activationofthe“Full”operatingmode•Pressandholdthe“+”and“-”
buttons for more than 3 seconds.
4.6.4 “OFF” OPERATING MODE
Inthisoperatingmode,theapplianceisswitchedoff.Ifnecessary,theelectric
booster heater is switched on by itself for the frost protection function.
Frost protection
The electric booster heater starts up when the water temperature in the
cylinder falls to 5 °C and switches off again when the temperature reaches
8°C.
4.7 “MODE” SUBMENU - HEATING MODE
3 different types of heating mode can be selected in the “Mode” submenu.
•Electrical heating mode
•“Heat pump” operating mode
•“Combi” operating mode

20
ENG Installationandusermanual
4.7.1 ELECTRICAL HEATING MODE
Inthisoperatingmode,theelectricboosterheateristheonlyheatappliance
used. The water temperature can be set to between 30 °C and 70 °C.
4.7.2 “HEAT PUMP” OPERATING MODE
Water heating is only guaranteed when the inlet air temperature is between
-10 °C and 35 °C. Selecting this operating mode means that the heat pump is
the only heat appliance used. The water temperature can be set to between
30°Cand60°C.Atverylowtemperatures,thefrostprotectionfunctionis
activated.
4.7.3 “COMBI” OPERATING MODE
Inthisoperatingmode,twoheatappliancesareuseddependingonthe
situation:theheatpumportheelectricboosterheater.Thewatertemperature
can be set to between 30 °C and 70 °C. If the water temperature in the
cylinder below 60 °C and the inlet air temperature is between -10 °C and 35
°C,theheatpumpistheonlyheatapplianceused.Otherwise,theelectric
booster heater is switched on.
4.8 “SET” SUBMENU - SETTINGS
Youcansetvariousparametersinthe“Set”submenu:
•Date
•Prog - Operating times
•Leg - Legionella
•Duct - use of ducts
•Purg - Drain
•Fset - Default settings
Other manuals for VHW 260
1
Table of contents
Other flamco Heat Pump manuals
Popular Heat Pump manuals by other brands

Nibe
Nibe F1255PC BE user manual

CHOFU
CHOFU AEYC-1639U-CH Installation and instruction manual

HIdRos
HIdRos LHA P4U Series Technical manual

Technibel
Technibel Liberty 300 Installation and operating instructions

ESP
ESP HT 9 KW Installation and user manual

Hitecsa
Hitecsa MISTRAL Series Installation, operation & maintenance manual

Lennox
Lennox 2SHP13 Series Installation and maintenance instructions

Bryant
Bryant LEGACY 223R installation instructions

Heiko
Heiko Thermal 6 user manual

Davey
Davey DHP90 Installation and operating instructions

Daikin
Daikin ETBX16DF6V Operation manual

Mitsubishi Electric
Mitsubishi Electric TRANE TPKA0A 1LA00 Series Operation manual