Fleschhut Thermo-bug AirBlower User manual

1
Instruction Manual
Thermo-bug AirBlower
Introduction
Read this instruction manual thoroughly and familiarize yourself with all its controls before turning
on the AirBlower.
Pay special attention to any hazards pointed out.
No liability will be accepted for any damage due to improper handling and use and the warranty will
cease.
The AirBlower has been checked and tested for its functionality before delivery.
On receipt please check for any damage during transport.

2
Thermo-bug AirBlower
AirBlower includes stand for circulating hot air in rooms and integrated expandable hose.
Circulates air from just below ceiling and distributes it across floor.
Package includes:
Thermo-bug AirBlower with expandable hose and stand.
Appliance comes ready to use and with full instruction manual.
No liability will be accepted for improper handling and use.
Thermo-bug
A brand of Fleschhut UG
Kremser Weg 7
88339 Bad Waldsee
Germany
Updated May 2016
Product Features
Can be used in room temperatures of 0 –70 degrees C
Very quiet running, only 51 dBA
Circulates 700 cubic metres/h
Casing water and contaminant resistant to IEC specification IP54
Suction Hose, diameter 20 cm, heat resistant
Light weight, easy to handle (9.15 kg)
Quite and Light
Areas of operation
In rooms with temperatures of up to 70 degrees C.
For heat treatments in enclosed spaces
In switch rooms for electronic devices
In drying chambers
Operation
Ventilator runs permanently Circulates air from just below ceiling and distributes it across floor.

3
Overheating
Heater features overheating protection, thermal cut-out with manual reset.
In the event of overheating, follow these instructions.
Disconnect heater from power supply
Establish reason for overheating
In case the reason for overheating cannot be found, contact a qualified technician.
Checklist - Heat Treatment
Preparation and Safety Instructions
* Deactivate sprinklers, heat and smoke detectors
* Unplug all electronic devices, they can remain inside the room though (except for Plasma TVs)
* Move furniture approx. 10 cm away from the walls
* Take off power point and switch covers in order to apply a natural barrier with DE powder
* Thoroughly vacuum all rooms
Items that need to be removed from the room before a heat treatment:
* Pets & plants
* Pictures, oil paintings and mirrors (use tape to keep fitted mirrors in place)
* Ink or laser printers
* Food from fridges or freezers
* Carbonated drinks
* Medication, Cosmetics (lipsticks, lotions, etc.)
* Aerosol cans (hairspray, deodorant, etc.)
* Wax products (candles, soaps, etc.)
* Weapons and ammunition
* Fire extinguishers
* Musical instruments
* Valuable and irreplaceable Items (photos, jewellery, etc.)
* Vinyl records, CDs, DVDs, etc.
All linen should remain in the room or be placed in a sealable plastic bag to be washed
at a minimum temperature of 60 degrees C or frozen to –18 degrees C.

4
Keep in mind that bugs may be re-introduced at any time.
We recommend a prevention treatment and bed bug monitoring!
Heat treatment with Thermo-bug System
Living creatures will die within a short period of time, if unprotected in temperatures
above 45 degrees C. Thermo-bug compact heaters have been designed to bring up any room
temperature to a maximum of 85 degrees C.
The use of two Thermo-bug heaters and the AirBlower is recommended for an even and well
dispersed temperature rise.
The heater need to be switched on again after a power cut!
Technical Data
Voltage: 230 V
Heat Output: 72W
Amperage: max 0.32 A
Room Temperature: 0 –70 degrees C
Noise Level: 51 dBA
Air Circulation: 700 cubic metres/h
Casing: Stainless Steel EN 1.4016, variable power output dial with integrated
thermostat, IP54 (water resistant)
Weight: 9.15 kg
Stand: 2 kg
Dimensions: Width = 40 cm Depth = 63 cm Height = 40 cm
Stand: Width = 12 cm (dimensions packed) Depth = 1.20 cm Height = 12 cm
Suction Hose: Diameter 20 cm, heat resistant
Maintenance
Regular cleaning of the heater externally and internally prevents overheating and reduces fire risk.
Safety Precautions
Make sure there are no objects preventing the ventilator from sucking in and blowing out air
before operating the heater.
Keep small items away from the vicinity of the running ventilator.
Caution –surfaces of heater are hot during operation!
Keep flammable items away from the heater.
Never cover the fan and hose when running.
Make sure nothing can fall onto the AirBlower.
After use keep the ventilator running for at least 10 minutes!
Do not disconnect from power supply as heater needs to cool down.
Get regular service check on the machine by a master electrician.

5
Warranty is only valid if the heater is used in accordance with the purpose and installation
as well as maintenance guidelines of the manufacturer. We do not accept liability for any costs
or damage caused by the use of the heater.
Wiring Diagram
AirBlower
240V
1. Ventilator
2. Switch
3. Overheating Protection
Attention
After use of the Thermo-bug system the ventilator needs to run at least 10 min. to cool down as
overheat could damage electronics and the machine!
Other recommendation:
-Professional Training Day/Week with one of our Technicians on Bed Bug’s & Co.
-Wify - Data logging system available on request!
-Bed Bug & Co. handy tool pack
-Network access to www.hi-eco-genic.com
-Treatment Description List
-Overall support on latest and updates for Bed Bugs & Co.
Please refer to Brochure of Thermo-bug.
Table of contents
Popular Blower manuals by other brands

Milwaukee
Milwaukee 2824-20 Operator's manual

Poulan Pro
Poulan Pro PPBP30 instruction manual

Doctor-San
Doctor-San 41 Series operating instructions

Ikra
Ikra LSN 2600 E operating instructions

Meec tools
Meec tools 018285 operating instructions

Scag Power Equipment
Scag Power Equipment CLASSIC LBC15-BS950 Operator's manual