Fondis WINEMASTER SP 100 User manual

WINEMASTER
SP 100
Mode d’emploi
Gebrauchsanweisung
Instruction for use

2
CONTENTS
1CHARACTERISTICS .......................................................................................................... 4
1.1 DIMENSIONS :........................................................................................................................ 4
2LAYOUT OF PREMISES.................................................................................................... 5
2.1 INDOOR UNIT......................................................................................................................... 5
2.2 OUTSIDE UNIT ....................................................................................................................... 5
2.3 THE CELLAR .......................................................................................................................... 5
2.3.1 INSULATION............................................................................................................................ 5
2.3.2 CHOICE OF INSULATION ......................................................................................................... 6
2.3.3 WALL AND CEILING INSULATION ............................................................................................. 6
2.3.4 FLOOR INSULATION ................................................................................................................ 6
2.3.5 THE DOOR .............................................................................................................................. 7
2.3.6 INSULATION OF OTHER ITEMS................................................................................................. 7
3INSTALLING THE OUTSIDE UNIT ................................................................................. 7
Make sure you have chosen the best place for fitting the outside unit : ....................................... 7
3.1 DRILLING THE WALL .......................................................................................................... 7
3.2 FLEXIBLE DISMOUNTING.................................................................................................. 7
3.2.1 THE COVER............................................................................................................................. 7
3.2.2 THE FIXING BRACKETS............................................................................................................ 8
3.2.3 THE REFRIGERANT CONNECTIONS .......................................................................................... 8
3.2.4 ELECTRICAL CONNECTOR....................................................................................................... 9
3.3 INSTALLATION OF THE OUTSIDE UNIT .......................................................................... 9
3.3.1 INSTALLATION OF THE WALL MOUNTING BRACKETS ............................................................... 9
3.3.2 ATTACHING THE OUTSIDE UNIT .............................................................................................. 9
4INSTALLATION OF THE INSIDE UNIT ........................................................................ 11
4.1 RE-CONNECTION OF THE FLEXIBLE ............................................................................. 11
4.2 INSTALLING THE CONDENSING WATER FLUE........................................................... 11
5USING THE WINEMASTER SP100................................................................................. 12
5.1 CONNECTING THE AIR-CONDITIONER ......................................................................... 12
5.2 CONTROL PANEL................................................................................................................ 12
AUTOMATIC DEFROST.................................................................................................................. 12
6SERVICING THE WINEMASTER AIR-CONDITIONER .............................................. 12
6.1 CHANGING THE FILTER.................................................................................................... 13
7WARRANTY...................................................................................................................... 14
7.1 YEARS CONTRACTUAL WARRANTY............................................................................. 14
7.2 TERMS OF APPLICATION OF THE GUARANTEE.......................................................... 14
7.3 EXCLUSIONS AND LIMITS OF GUARANTEE ................................................................ 14

3
In former times, good french cellars were built to maintain a temperature not exceeding
14 to 16°C in all seasons.
Today, this is rarely the case.
Nevertheless, a cellar worthy of the name must be protected against wide variations in
temperature, be as damp as necessary and ventilated, dark and free of vibration.
This is why, for more than fifteen years, we have used the expertise of specialists and
enthusiastic amateurs to design, develop, test and produce thousands of air-conditioners
destined to help in the storage and ageing of wine.
If you follow our advice and respect our recommendations Winemaster will provide the
optimal ageing conditions for your treasured wine collection.
You have to read the installation and operating guide for your FONDIS WINEMASTER cellar
air-conditioner.
Contact us if you have any questions :
So....even if there ay be long years to wait before the wine reaches perfection, the great
day will come when you face the delicate job of uncorking.
Hold the bottle carefully – do not remove the capsule on a level with the mouth – use a
good quality tool or lever – remove the cork without shaking the bottle and examine the “
mirror “..
But that’s another story......
SERVICE CLIENTS FONDIS
Phone 33 3 89 37 75 15/Fax 33 3 89 37 75 89
ATTENTION : Wait for 24 hours before switching on the air-conditioner.
FROM VINEYARD TO WINE

4
1 CHARACTERISTICS
Setting the temperature Preset to 12°C, adjustable between 12 and 25°C*
Maximum outdoor temperature 35°C**
Cooling power 2500W at 12°C**
Heating power 1000W
Electricity supply 230-240V 50Hz with earth connection ( supplied
with 3m cable )
Electrical power 1250W
Gas R407C without CFC
Refrigerant gas 1000g
Length of refrigerant flexible
connection 5m
The circuit breaker must be at least 16 Amps.
* The insulation quality and thickness has to be in accordance with the volume of the cellar and the set
temperature.
** The cooling performance is dependant from the outside temperature. Therefore, the set temperature of 12°C
for the cellar cannot be maintained if the outside temperature of the cellar is maintained at 35°C.
If the thermal safety functions to often, there is a risk for the condensator and starter to be damaged.
In all the cases, it must be avoided that the outside temperature remains at 35°C, this high
temperature should be limited to the summer period.
1.1 DIMENSIONS :
360mm
435mm
465mm
480mm395mm
1005mm

5
2 LAYOUT OF PREMISES
The air-conditioner is composed by two separate units which are connected by an electric and refrigerant flexible
cable of 5 mts. The distance between the two units cannot be more than 5 mts.
2.1 INDOOR UNIT
The indoor unit is entirely installad inside the cellar directly on the floor or fixed on the wall with adapted special
brackets.
2.2 OUTSIDE UNIT
The outside unit must be fixed on an outside wall in an area free from obstruction which may cause irregular air
distribution and/or return in front and back of the unit.
2.3 THE CELLAR
2.3.1 INSULATION
Insulation of the 4 walls, the door, the ceiling and the floor is essential for the Winemaster to work properly.
Adequate insulation helps to obtain the stability of the temperature and the humidity.
The board on the next page ( choice of insulation ) can be used to determine the type and the thickness of
insulation needed according to the internal volume of the cellar and a cellar temperature of 12°C.
Insulation continuity :
Insulation components must be assembled preferably by interlocking panels or glueing the panels together, to
ensure perfect continuity of insulation.
This is very important : it prevents heat and humidity entering from the outside which would counter the effects
of regulation.
IMPORTANT
The validity of the WINEMASTER guarantee depends on the values in the "Choice of insulation"
table being strictly respected, for all the cellar walls, including floor and ceiling + door, as well as
perfect continuity of insulation and installation in accordance to the user guide.
Table of contents
Other Fondis Air Conditioner manuals
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu ASYG 09 LLCA installation manual

York
York HVHC 07-12DS Installation & owner's manual

Carrier
Carrier Fan Coil 42B Installation, operation and maintenance manual

intensity
intensity IDUFCI60KC-3 installation manual

Frigidaire
Frigidaire FAC064K7A2 Factory parts catalog

Sanyo
Sanyo KS2432 instruction manual

Mitsubishi Electric
Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Panasonic
Panasonic CS-S18HKQ Service manual

Panasonic
Panasonic CS-E15NKE3 operating instructions

Gree
Gree GWH18TC-K3DNA1B/I Service manual

Friedrich
Friedrich ZoneAire Compact P08SA owner's manual

Daikin
Daikin R32 Split Series installation manual