Installation Instruction:
1. Connect the protected equipment to “LOAD" T1、T2 terminal.
2. Connect AC power cord to "LINE" L1、L2 terminal.
3. The all terminals without voltage polarity restrictions.
4. To ensure the effective protection of your equipment, the ground terminal “E” must be
grounding and grounding resistance should less 100Ω.
LED Indication:
1. LED on: normal
2. LED off: failed
Caution:
Make sure the grounding terminal "E" connect to the lightning protection grounding. Do
not access to the power ground wire, ground rod, and gas pipelines
Specification:
ITEM NO. SP001P-AC110 SP001P-AC220
Wire >150V >300V
Nominal
peak
voltage Wire~grounding >150V >300V
Surge Current Capacity 6000A (8x20uS)
Surge Voltage Capacity 6,000V (1.2uS x 50 uS)
Response time <0.1uS
Wire <1mA (at150VAC) <1mA (at300VAC)
Leakage
current Wire~grounding <1mA (at150VAC) <1mA (at300VAC)
Max. Load Current 10Amp (Max)
Temperature Operation: 0 to 55 C, Storage: -20 TO 85 c, Humidity: up to 95%
Connectors Terminal
Material Metal Black
Dimensions W x H x D mm 87 x 67 x 27 mm
WEIGHT g 130 g
2
FORESIGHT CCTV INC. | 5863 Leslie Street, Unit#713, North York, Ontario,Canada, M2H 1J8 | http://www.foresight-cctv.com | 1-888-GO2-CCTV