Fortress Technologies Osbourn IBL-H User manual

1
Operating Instructions: Interlock Blocking - IBL
Description
Fortress’ IBL is an Interlock Blocking device designed to
provide additional safeguarding to prevent operators being
trapped inside a safeguarded space in machine guarding
applications where whole body access is required. The IBL
works in conjunction with existing interlocking to prevent
the unexpected reset or restart of the safety-related circuit.
It works by forcing the removal of a personnel or safety key
before the guard can be fully opened and preventing the
guard from fully closing until the key is returned. Thus, while
the key is with the operator inside the area, the interlock is
blocked from allowing the machine to be reset or restarted.
Additional padlock points allow for each individual entering
the area to apply their own means of control to the device.
As a purely mechanical component complete with an
integrated mounting plate it is easily retrotted or added to
an existing system, regardless of interlock type, without the
need for wiring or programming.
Options & Ordering Information
Description Part No.
IBL device suitable for Left hand facing Hinged Doors IBL2H-1-1-CLSS-MP1
IBL device suitable for Right hand facing Hinged Doors IBL4H-1-1-CLSS-MP1
IBL device suitable for Left hand facing Sliding Doors IBL2S-1-1-CLSS-MP1
IBL device suitable for Right hand facing Sliding Doors IBL4S-1-1-CLSS-MP1
NOTICE!
IBL is not an interlock and must only be used in addition to an interlock as part of a safety related part of a control system that
meets required reliability.
The IBL device cannot be used in conjunction with an Interlock that includes an Escape Release or Internal facing
handle.
Important:
The IBL Interlock Blocking Device is designed for use according to the installation and operating instructions enclosed. It
must be installed by competent and qualied personnel who have read and understood the whole of this document prior to
commencing installation.
If the Device or guarded machinery equipment is used in a manner not specied by the manufacturer, the protection provided
by the equipment may be impaired.
Any modication to or deviation from these instructions invalidates all warranties.
Fortress Interlocks Ltd accepts no liability whatsoever for any situation arising from misuse or misapplication of the Device.
The IBL device alone is not an Interlock and must only be used in addition to an Interlock as part of a complete
machine guarding system. The paired Interlock device must meet all relevant safety requirements and applicable
safety standards.
BEWARE OF INTENTIONAL MISUSE CAUSED BY OPERATORS WANTING TO BYPASS SAFETY SYSTEMS. THE
INSTALLER SHOULD ASSESS THE RISKS AND MITIGATE AGAINST THEM.
The installation and operation of the IBL Device and the complete machine guarding system must take into account the
requirements of ISO 14119:2013, in particular Section 7 - Design for minimising defeat possibilities.
In order to maintain device safety rating, overall machine guarding system must be validated to EN ISO 13849-2 and/or
evaluated in accordance with IEC 62061.
IF YOU HAVE ANY QUESTIONS OR QUERIES OF ANY NATURE WHATSOEVER PLEASE CONTACT THE SUPPLIER
WHO WILL BE PLEASED TO ADVISE AND ASSIST.
IBL-H
IBL-S

2
Operating Instructions: Interlock Blocking - IBL
Technical Specication
Construction Materials 316 Stainless Steel and Stainless Steel to BS3146-2:1975 (ANC4B)
Mechanical life 1,000,000 operations
Ambient Temperature -25°C to +80°C**
Shock and Vibration Resistance Tested in accordance with IEC 60068-2-6 and IEC 60068-2-27
Environment Type Indoor & Outdoor
Maximum Door Thickness 70mm at ≥600mm door width*
*Note; any gaps in door frame when closed must not exceed the limits specied in BS EN ISO 13857.
**The units will only continue to work below freezing point (0°C) where it can be guaranteed that ice will not form on or in the unit; as it will cause the mechanical parts to bind and
jam.
Safety Functions Part No.
Safety Function 1 Prevent unexpected machine restart. IBL
Functionality
IBL is to be used to add additional safeguard functionality to an existing Door, Gate or Hatch that is guarding a hazardous or
unsafe area.
The front mounted Paddle of the IBL device ensures the Door or Gate that the product is mounted to cannot be fully opened
until a Personnel / Safety Key has been taken. Once the Key has been removed a rear mounted Blocker plate extends out-
wards between the Door or Gate and the hazardous or unsafe area. When extended, the Blocker plate prevents the Door or
Gate from being re-closed and locked before the Personnel Key has been reinserted and rotated. Padlocks can be added to
the Blocker plate for additional Interlock Blocking functionality.
Opening a Door or Gate with an IBL device tted
• Remove the locking mechanism of existing Door lock or Interlock product if tted.
• Open the Door or Gate until it comes into contact with the extended Paddle of the IBL device.
• Rotate and remove the Personnel Key of the IBL device. The paddle is sprung loaded. As the key is removed it will spring
away from the door, covering the Personnel lock. Simultaneously, rotation of the Personnel key will revolve the blocker
plate behind the gate. For Sliding Gates - slide door back to end of slot
• Open the Door or Gate fully.
• For sliding doors the hook will be removed from the knob holding the door closed.
Closing a Door or gate with an IBL device tted
• Close the Door or Gate until it rests against the extended Blocker plate of the IBL device.
• Rotate the paddle clockwise until the entry to the personnel lock is exposed.
• Open the dustcover insert and rotate the Personnel Key into the IBL device.
• Fully close the Door or Gate.
• For sliding doors rotate paddle and slot knob in opening of paddle

Operating Instructions: Interlock Blocking - IBL
3
Figure 1: Dimensional Drawing - IBL for Hinged, Left Hand Entry
Figure 2: Dimensional Drawing - IBL for Hinged, Right Hand Entry
FORTRESS
A company
Halma
www.fortressinterlocks.com
THE COPYRIGHT OF THIS DRAWING BELONGS TO FORTRESS INTERLOCKS Ltd.
THE CONTENT OF THIS DRAWING IS CONFIDENTIAL AND MUST NOT BE
DISCLOSED TO ANY 3rd PARTY WITHOUT SPECIFIC, WRITTEN APPROVAL.
ALL DIMENSIONS
ARE IN mm UNLESS
OTHERWISE STATED A3 SCALE: 0.33 SHEET: 1 OF 1
ORIGINAL SIZE DATE: 10-11-2020 ISSUE: 0-B
INTERLOCK BLOCKING DEVICE FOR HINGED, LEFT HAND ENTRY DWG NO: SD-00022
DOOR CLOSED STATE
DOOR OPEN STATE
IBL SHOWN IN LEFT HAND FACING CONFIGURATION
(EXAMPLE PART NUMBER: IBL2H-1-1-CLSS-MP1)
DOOR ENTRANCE
THIS SIDE OF
DEVICE
BLOCKER PLATE
ENGAGED AND
PREVENTING DOOR
FROM CLOSING
PADDLE PLATE
ENGAGED AND
PREVENTING DOOR
FROM OPENING FULLY
FORTRESS
A company
Halma
www.fortressinterlocks.com
THE COPYRIGHT OF THIS DRAWING BELONGS TO FORTRESS INTERLOCKS Ltd.
THE CONTENT OF THIS DRAWING IS CONFIDENTIAL AND MUST NOT BE
DISCLOSED TO ANY 3rd PARTY WITHOUT SPECIFIC, WRITTEN APPROVAL.
ALL DIMENSIONS
ARE IN mm UNLESS
OTHERWISE STATED A3 SCALE: 0.50 SHEET: 1 OF 1
ORIGINAL SIZE DATE: 10-11-2020 ISSUE: 0-B
INTERLOCK BLOCKING DEVICE FOR HINGED, RIGHT HAND ENTRY DWG NO: SD-00023
DOOR CLOSED STATE
DOOR OPEN STATE
IBL SHOWN IN RIGHT HAND FACING CONFIGURATION
(EXAMPLE PART NUMBER: IBL4H-1-1-CLSS-MP1)
DOOR ENTRANCE
THIS SIDE OF
DEVICE
BLOCKER PLATE
ENGAGED AND
PREVENTING DOOR
FROM CLOSING
PADDLE PLATE
ENGAGED AND
PREVENTING DOOR
FROM OPENING FULLY

4
Operating Instructions: Interlock Blocking - IBL
Figure 3: Dimensional Drawing for IBL-S
Figure 4: Dimensional Drawing for IBL-S
FORTRESS
A company
Halma
www.fortressinterlocks.com
THE COPYRIGHT OF THIS DRAWING BELONGS TO FORTRESS INTERLOCKS Ltd.
THE CONTENT OF THIS DRAWING IS CONFIDENTIAL AND MUST NOT BE
DISCLOSED TO ANY 3rd PARTY WITHOUT SPECIFIC, WRITTEN APPROVAL.
ALL DIMENSIONS
ARE IN mm UNLESS
OTHERWISE STATED A3 SCALE: 1.00 SHEET: 1 OF 3
ORIGINAL SIZE DATE: 18-05-21 ISSUE: 0-A
INTERLOCK BLOCKING DEVICE FOR SLIDING DOORS DWG NO: SD-00030
DOOR CLOSED STATE
DOOR OPEN STATE
DOOR ENTRANCE
THIS SIDE OF
DEVICE
HOOK PLATE
ENGAGED AND
PREVENTING DOOR
FROM OPENING FULLY
BLOCKER PLATE
ENGAGED AND
PREVENTING DOOR
FROM CLOSING
FORTRESS
A company
Halma
www.fortressinterlocks.com
THE COPYRIGHT OF THIS DRAWING BELONGS TO FORTRESS INTERLOCKS Ltd.
THE CONTENT OF THIS DRAWING IS CONFIDENTIAL AND MUST NOT BE
DISCLOSED TO ANY 3rd PARTY WITHOUT SPECIFIC, WRITTEN APPROVAL.
ALL DIMENSIONS
ARE IN mm UNLESS
OTHERWISE STATED A3 SCALE: 0.50 SHEET: 2 OF 3
ORIGINAL SIZE DATE: 18-05-21 ISSUE: 0-A
INTERLOCK BLOCKING DEVICE FOR SLIDING DOORS DWG NO: SD-00030

5
Operating Instructions: Interlock Blocking - IBL
Figure 5: Operational Sequence for IBL-S
FORTRESS
A company
Halma
www.fortressinterlocks.com
THE COPYRIGHT OF THIS DRAWING BELONGS TO FORTRESS INTERLOCKS Ltd.
THE CONTENT OF THIS DRAWING IS CONFIDENTIAL AND MUST NOT BE
DISCLOSED TO ANY 3rd PARTY WITHOUT SPECIFIC, WRITTEN APPROVAL.
ALL DIMENSIONS
ARE IN mm UNLESS
OTHERWISE STATED A3 SCALE: 1.00 SHEET: 3 OF 3
ORIGINAL SIZE DATE: 18-05-21 ISSUE: 0-A
INTERLOCK BLOCKING DEVICE FOR SLIDING DOORS DWG NO: SD-00030
DOOR CLOSED STATE KEY TURNED STATE DOOR OPEN STATE

6
Operating Instructions: Interlock Blocking - IBL
Tools and Fixings Required
• Minimum 2 x M8 screws for securing IBL device.
• Minimum 1 M8 Screw for securing IBL-S Knob.
• Screws must be suitable length for a minimum of 10mm thread engagement.
• Screws must be security type to prevent unauthorised removal or tampering.
• Required torque setting; 40 Nm.
• 2 x M8 Nut / T-Nut / Threaded Hole for securing IBL device.
• 1 x M8 Nut / T-Nut / Threaded Hole for securing IBL -S Knob.
• Driver suitable for securing M8 screws.
• Adhesive Threadlocker to secure mounting xings from loosening due to vibration.
Mounting
1. Locate the IBL device so that it can correctly Block the Door or Gate with both the front mounted Paddle and rear mounted
Blocker plates. See Fig. 1 and Fig.2 for details.
2. Secure the IBL device using minimum 2 x M8 screws through the available mounting holes at the top and bottom of the
rear mounted mounting plate. Secure the IBL-S Knob using 1 x M8 screws through the centre of the knob.
3. Perform Mechanical Function tests before completing installation and commission. See Mechanical Function test section
for more details.
Mount the complete device only in the correctly assembled condition.
• All mounting surfaces should be at, stable and suitable of providing a minimum of 10mm M8 thread engagement or
sucient support to either an M8 Nut or M8 T-Nut.
• The IBL device must be located so that scheduled inspection and maintenance procedures are all easily possible.
• The complete machine guarding installation must conform to all relevant design, construction and installation standards
and guidelines.
• Any gap around the perimeter of the machine and guarding when closed and locked (Safety Outputs High) must not
exceed the limits specied in ISO 13857 & ISO 14120.
• All xing screws used to mount the complete Device must be permanently prevented from removal. If mounting xings
are visible, they must be secured against removal by personnel using standard tools, manipulation and un-authorised or
un-identiable removal. If mounting xings are not visible or hidden, they must be secured against removal or loosening
due to vibration. In both cases, a middle strength adhesive threadlocker is required.
• The complete Device must not be used as a mechanical stop. Where applicable, precautions must be made to ensure the
door or gate of any guarded area has sucient support and stops to prevent the impact on the Device.
Note: that it is not possible for a left-hand facing IBL2H device to be recongured or re-assembled as a right-hand facing
IBL4H device. If alternative handing and orientation is required, please contact your local Fortress representative.
Note: For IBL-S the device is the same for left and right hand just rotate the device 180 degrees
Mechanical Function Test Instructions
Test 1
1. Remove the locking mechanism of existing Door lock or Interlock product if tted.
2. Open the Door or Gate.
It must not be possible to fully open the Door or Gate until the Personnel Key has been rotated and removed.
Test 2
1. Fully open the Door or Gate open and remove the Personnel Key.
2. Close the Door or Gate.
It must not be possible to fully close the Door or gate until the Personnel Key has been re-inserted and rotated.
It must not be possible for the existing Door lock or Interlock (if tted) to re-engage until the Personnel Key has been
re-inserted and rotated.
It must not be possible for a machine restart signal to be generated (such as via an additional Door lock or Interlock)
until the Personnel Key has been reinserted and rotated.

Operating Instructions: Interlock Blocking - IBL
7
Service and Inspection
Regular inspection of the following is necessary to ensure trouble-free, lasting operation:
• Correct operating function
• Secure mounting of components
• Debris and wear
• WD40 lubricant or equivalent, should be applied to each mechanical element every 10,000 operations, or sooner, to ensure
smooth product operation and function. There are no user serviceable parts in this product. If damage or wear is found with
an assembly, please contact your local Fortress Channel Partner for a replacement. The complete device must be replaced
after 1 million operations.
Disposal
This interlock does not contain any certied hazardous materials so should be disposed of as industrial waste. Electrical
items should not be disposed of in general waste and must be appropriately recycled.
Liability Coverage is Voided Under the Following Conditions:
• If these instructions are not followed.
• Non-compliance with safety regulations.
• Installation and electrical connection not performed by authorised personnel.
• Non-implementation of functional checks.
Protection Against Environmental Inuences
A lasting and correct safety function requires that the device be protected against the ingress of foreign bodies such as swarf,
sand, blasting shot, etc. The device is to be mounted away from the machine, or by the use of anti-vibration mountings, in
order to avoid the eects of vibration, shock and bump.
Use in Dusty Environments: Careful product selection is required, which is best performed under the guidance of a Fortress
Representative, in order to assess the dust type and product style required.
Use in Corrosive Environments: Careful product selection is required, which is best performed under the guidance of a
Fortress Representative.
The manufacturer reserves the right to modify the design at any time and without notice.
This guide should be retained for future reference.
Fortress Interlocks Ltd, 2 Inverclyde Drive, Wolverhampton, WV4 6FB, United Kingdom, Tel: +441902349000, Web: www.fortressinterlocks.com June 2021 - v1.1
This manual suits for next models
1
Table of contents
Other Fortress Technologies Fencing & Gate manuals

Fortress Technologies
Fortress Technologies PURE VIEW FULL GLASS PANEL AL13 HOME User manual

Fortress Technologies
Fortress Technologies Evolver User manual

Fortress Technologies
Fortress Technologies INSPIRE User manual

Fortress Technologies
Fortress Technologies PURE VIEW GLASS BALUSTER FOR Fe26 STEEL User manual

Fortress Technologies
Fortress Technologies Pro Series User manual

Fortress Technologies
Fortress Technologies Osbourn PBL2A-1-1-CLSL-MP1 User manual

Fortress Technologies
Fortress Technologies VERSAI RESIDENTIAL User manual

Fortress Technologies
Fortress Technologies PURE VIEW GLASS BALUSTER AL13 HOME User manual