HOSE ADAPTER
MODEL CX6-AE-M
INSTALLATION GUIDE

The informaon in this publicaon is provided for reference only. While every eort has been made to ensure the reliability and accuracy of
the informaon contained in this manual at the me of prinng, we recommend that you refer to “franklinfueling.com” for the most current
version of this manual. All product specicaons, as well as the informaon contained in this publicaon, are subject to change without noce.
Franklin Fueling Systems does not assume responsibility and expressly disclaims liability for loss, damage, or expense arising out of, or in any way
connected with, installaon, operaon, use, or maintenance by using this manual. Franklin Fueling Systems assumes no responsibility for any
infringement of patents or other rights of third pares that may result from use of this manual or the products. We make no warranty of any kind
with regard to this material, including, but not limited to, the implied warranes of merchantability and tness for a parcular purpose.
Copyright © 2020 Franklin Fueling Systems, LLC, Madison, WI 53718. All world rights reserved. No part of this publicaon may be stored in a
retrieval system, transmied, or reproduced in any way, including, but not limited to, photocopy, photograph, magnec, or other record, without
the prior wrien permission of Franklin Fueling Systems.
For technical assistance, please contact:
franklinfueling.com
3760 Marsh Rd. • Madison, WI 53718 • USA
Tel: USA & Canada +1 800 225 9787 • Fax: +1 608 838 6433
Tel: UK +44 (0) 1473 243300 • Tel: Mex 001 800 738 7610
HEALY is a trademark of Franklin Electric Company, Inc,
405214002 r1
Conventions used in this manual
This manual includes safety precauons and other important informaon presented in the following format:
NOTE: This provides helpful supplementary informaon.
IMPORTANT: This provides instrucons to avoid damaging hardware or a potenal hazard to the environment, for example: fuel leakage from
equipment that could harm the environment.
CAUTION: This indicates a potenally hazardous situaon that could result in minor or moderate injury if not avoided. This may also be used to
alert against unsafe pracces.
WARNING: This indicates a potenally hazardous situaon that could result in severe injury or death if not avoided.
DANGER: This indicates an imminently hazardous situaon that will result in death if not avoided.
Operating precautions
Franklin Fueling Systems (FFS) equipment is designed to be installed in areas where volale liquids such as gasoline and diesel fuel are present.
Working in such a hazardous environment presents a risk of severe injury or death if you do not follow standard industry pracces and the
instrucons in this manual. Before you work with or install the equipment covered in this manual, or any related equipment, read this enre
manual, parcularly the following precauons:
IMPORTANT: To help prevent spillage from an underground storage tank, make sure the delivery equipment is well-maintained, that there is a
proper connecon, and that the ll adaptor is ght. Delivery personnel should inspect delivery elbows and hoses for damage and missing parts.
CAUTION: Use only original FFS parts. Substung non-FFS parts could cause the device to fail, which could create a hazardous condion and/
or harm the environment.
WARNING: Follow all codes that govern how you install and service this product and the enre system. Always lock out and tag electrical
circuit breakers while installing or servicing this equipment and related equipment. A potenally lethal electrical shock hazard and the possibility
of an explosion or re from a spark can result if the electrical circuit breakers are accidentally turned on while you are installing or servicing this
product. Refer to this manual (and documentaon for related equipment) for complete installaon and safety informaon.
WARNING: Before you enter a containment sump, check for the presence of hydrocarbon vapors. Inhaling these vapors can make you dizzy or
unconscious, and if ignited, they can explode and cause serious injury or death. Containment sumps are designed to trap hazardous liquid spills
and prevent environmental contaminaon, so they can accumulate dangerous amounts of hydrocarbon vapors. Check the atmosphere in the
sump regularly while you are working in it. If vapors reach unsafe levels, exit the sump and venlate it with fresh air before you resume working.
Always have another person standing by for assistance.
WARNING: Follow all federal, state, and local laws governing the installaon of this product and its associated systems. When no other
regulaons apply, follow NFPA codes 30, 30A, and 70 from the Naonal Fire Protecon Associaon. Failure to follow these codes could result in
severe injury, death, serious property damage, and/or environmental contaminaon.
WARNING: Always secure the work area from moving vehicles. The equipment in this manual is usually mounted underground, so reduced
visibility puts service personnel working on it in danger from moving vehicles that enter the work area. To help prevent this safety hazard, secure
the area by using a service truck (or some other vehicle) to block access to the work area.
DANGER: Make sure you check the installaon locaon for potenal ignion sources such as ames, sparks, radio waves, ionizing radiaon,
and ultrasound sonic waves. If you idenfy any potenal ignion sources, you must make sure safety measure are implemented.

The Healy™ CX6-AE-M is a cast aluminum hose adapter used to connect a non vapor-ready
gasoline dispenser to a coaxial metric stage II vapor recovery hose. It has tapered BSPT threads
on the inlet and metric straight threads on the outlet side.
IMPORTANT: Do not use this adapter if the dispenser is already vapor-ready.
1/4" BSPT Vapor Return Port
1" BSPT M34 Straight
Hose Thread
Tools and equipment:
• Pipe sealant (non-hardening)
• Motor oil (for lubricang O-rings)
• 15" (38 cm) adjustable wrench
• 1.5" (38 mm) open-end wrench for hose end
Installaon:
1. Read this guide.
2. Disconnect power to the dispenser, and close emergency shut-o valves.
3. Remove the exisng hanging hardware.
4. Apply non-hardening pipe sealant to the exposed male BSPT threads on the product
dispenser.
5. Aach the tapered end of the CX6-AE-M hose adapter to the product dispenser threads.
Tighten this to 80 foot-pounds of torque. Make sure the vapor return port (¼” port on the
side of the adapter) is correctly posioned before nal ghtening.
6. Aach the appropriate fitting to the port of the CX6-AE-M adapter and torque to 40 foot-
pounds.
7. Connect the vapor return line to the ng in the vapor return port.
8. Install the Healy™ Stage II vapor recovery hanging hardware to the adapter. Lubricate the
O-rings with oil. Tighten to 35 to 70 -lbs.
9. If the dispenser is equipped with a breakaway, be sure to aach the hose clamp onto the
dispenser side of the breakaway.
Tesng:
1. Restore dispenser power and open the emergency shut-o valves.
2. Acvate the dispenser and dispense product unl the full-ow solenoid is acvated.
3. Release the nozzle lever and inspect for leaks around the adapter and hose ngs. Repair if
required.
4. Check to make sure there is no advance of the GALLONS/LITERS meter when the nozzle is
closed but with the dispenser authorized. If the GALLONS/LITERS meter slowly advances or
creeps, there is a leak from the product to vapor side of the hose.
5. Deacvate dispenser by returning nozzle to its holder.
6. If leaks are found, check hose ng to make sure O-rings are seated and not cut or rolled
over. Repair as necessary.

405214002 r1
A Franklin Fueling Systems Brand
Table of contents
Popular Adapter manuals by other brands

SilverStone
SilverStone ECD01 installation guide

Automation Networks
Automation Networks Highway Plus ANC-100e user manual

NEC
NEC N8104-178 Startup guide

Premier Tech Aqua
Premier Tech Aqua TAD-240 Installation guide and owner's manual

Rocstor
Rocstor Y10A236-A1 user manual

Steren
Steren 505-497 instruction manual