Specifications
subject to change.
CANADA
•
5855 Terry Fox Way
•
Mississauga, ON L5V 3E4
•
1-800-265-8352
•
frigidaire.ca
FPFU19F8R 07/15 © 2015 Electrolux Major Appliances, NA Printed in Canada
FPFU19F8RF 18.6 Cu. Ft.
All Freezer
All Freezer (18.6 Cu. Ft.) - R Models with ice maker
Professional (new handle)
Louvered Grille
(for 79"
opening)
(Single Trim Kit shown.)
B
C
A
Cut off
4" for 75"
opening
Top Trim Piece
(for 75"
opening)
Trim Kit
E
D
4"
Reversible Kickplate
Leveling System
(2) per unit raises height 2-9/16" min.
Only available with trim kits.
†Minimum depth from face of cabinet side
panels and requires recessed electrical outlet.
Built-In Installation
(without Trim Kit)
Single Unit
(A) 72" (B) 33" (C) 251
/4" min.†
Double Unit (Side-by-Side)
(A) 72" (B) 66" (C) 251
/4" min.†
Built-In Installation
(with Trim Kit & Leveling System)
Single Unit
(A) 75" or 79" (B) 33" (C) 251
/4" min.†
Double Unit (Side-by-Side)
(A) 75" or 79" (B) 66" (C) 251
/4" min.†
All-Freezer
Cutout
Dimensions
Optional Trim Kits
& Dimensions
Kits include top and side trim
pieces, louvered grille, reversible
kickplate and leveling system
to fit 75" or 79" opening height.
Single
Louvered Trim Kit
PN
# TRIMKITEZ1
(D) 751
/8" or 79 1
/8" (E) 34
3/4"
Double
Louvered Trim Kit
PN
# TRIMKITEZ2
(Includes hardware to secure
side-by-side units together.)
(D) 751
/8" or 791
/8" (E) 67
1
/8"
Note: Both kits attach
directly to cabinetry through
top trim piece or louvered
grille to stabilize unit(s).
Refer to detailed kit installation
instructions packed with
kit or on web.
Recessed electrical outlet
25"
Countertop
24"
Cabinet
25
1
/4"
min. side panels,
1
/2" min. width
(Trim Kit installation requires
3
/4"
min. width)
28 1
/4" to handle
extension
Allow at least
57
3/8" for overall depth
with door in 90°
open position
23
1
/2"
Power
cord
location
(right
bottom
rear)
26 1/2"32"
Water inlet location (left bottom rear)
location (left top rear)
*Height without
leveling system
71
3/8"*
70 3/16"*
7/16"
Recessed water line
• To ensure optimum performance, (do not install in areas where temperature
drops below 55° F or rises above 110° F) and avoid installing in direct sunlight
or close proximity to range, dishwasher or other heat source.
• Freezer must be placed on level surface of hard material, same height as
flooring. Surface must support approximately 800 lbs. when fully loaded.
Unit equipped with 4-point leveling.
“Built-In Look” Specifications
• Minimum opening of 72" H x 33" W x 25-1/4" D required for single-unit
“Built-In Look” installation; 66" W required for double-unit installation. (72" H
to be measured from finished floor to underside
of soffit or overhead cabinet.)
• Remove all wall / floor moulding prior to built-in installation.
Optional Trim Kit Specifications
• If optional Single or Double Louvered Trim Kit is to be used, different cutout
dimensions are required. Kit can be adapted to fit either 75" or 79" opening
height. (Refer to cutout dimensions on this page and detailed Louvered Trim
Kit installation instructions included with kit or on web.)
• Remove all wall / floor moulding prior to built-in installation.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.ca for detailed instructions.
Optional Accessories
• Single Louvered Trim Kit – (PN # TRIMKITEZ1).
• Double Louvered Trim Kit – (PN # TRIMKITEZ2).
• PureAdvantage® Air Filter
Replacement Cartridge – (PN # 241754001).
Built-In All-Freezer Specifications
• Product Shipping Weight – 245 Lbs.
• An electrical supply with grounded three-prong receptacle is required. The
power supply circuit must be installed in accordance with current edition of
National Electrical Code (NFPA 70) and local codes & ordinances.
• Voltage Rating – 115V / 60 Hz / 20 Amps
• Connected Load (kW Rating) @ 115 Volts = 0.55 kW
• Amps @ 115 Volts = 15 Amps
• Always consult local and national electric & plumbing codes.
• Water line for ice maker can enter opening through floor or rear wall Copper
tubing recommended between cold water line and water connection
location. Water line tubing recommended is 48" minimum length by 1/4"
diameter. Installation of easily accessible shutoff valve in water line required.
• Minimum 25-1/4" depth requires recessed electrical outlet and copper water line.
• To allow for ease of installation, tape excess power cord to back of unit.
• To allow for ease of moving out side-by-side units after installation, 84"
minimum length of coiled copper tubing recommended.
• When installing freezer adjacent to wall, cabinet or other appliance that
extends beyond front edge of unit, 20" minimum clearance recommended
to allow for optimum 140° door swing, providing complete drawer / crisper
access and removal. (Absolute 4" minimum clearance will ONLY allow for
90° door swing which will provide limited drawer / crisper access with
restricted removal.)
• Minimum 3/8" clearance required for sides and top of refrigerator or freezer
with 1" clearance at rear to allow for ease of installation, proper air circulation,
and plumbing / electrical connections.