FUJI TECOM FSB-8D User manual

FSB-8D
Instrumentsfor the location ofunderground utilitiesand water leaks.
FUJIDIGITALSOUNDDETECTOR
INSTRUCTION MANUAL


1
●INDEX Page
●USE 3
●WARRANTY........................................................................................
3
●FOR SAFE USE ........................................................................4
●BEFORE USE THE DETECTOR..............................................6
●DETECTOR COMPOSITION...................................................7
●NAME OF EACH PART....................................................................
8
●HOW TO USE...........................................................................9
1. HOW TO SET UP.................................................................9
2. REPLACEMENT OF BATTERIES..........................................10
3. HOW TO USE....................................................................12
4. SWITCHING THE SENSITIVITY (SENS)........................13
5. SENS SWITCH AND VOLUME CONTROL ....................14
●SPECIFICATION ....................................................................15
●HOW TO STORE THE DETECTOR ......................................16
●PARTSLIST AND ILLUSTRATIONS....................................17

2
Thank you very much for selecting Fuji FSB-8D digital sound detector.
This instruction manual describes handling of Fuji FSB-8D digital sound
detector.
As this manual contains methods for use, make sure to carefully read this
manual before use and to properly understand its handling method before
use.
*If you have lost this instruction manual, please notify your local agent or
us of it.

3
USE
Fuji FSB-8D digital sound detector is capable ofjudging water leakage by
detecting minor vibration tone, by amplifying it and by then comparingthe
detected tone with the reference based on the sound and numerical value
information. It is particularly suitable for water supply pipes madeof PVC
and polyethylene.
WARRANTY
Fuji FSB-8D Digital Sound Detector is repaired or replaced by free of charge
under the warranty within the period of twelve (12) months after the purchase
from Fuji representatives in case that the FSB-8Dis malfunctioned in spite
of the ordinary operation or handling in accordance with the cautions and
instructions given in this instruction manual.

4
FOR SAFE USE
WARNING
●If aheadphoneis usedforhearing leaksoundduringoperationofthisdetector,
it is hard to listen to the surroundingsound.
Pay full attention to the surrounding traffic circumstances at the time of use
of this detector.
●Do not operate this detector bywet hands, and do not replacethe batteries
by wet hands.
●Pay attention to the polarity of the batteries at the time ofreplacement of
the batteries.
(Liquid leakage, heat-up, breakage or the like may arise.)
●Do not throw the batteries into any open flame.
(Breakage, fire, personal injury orthe like may arise.)
●Do not try to disassemble the batteries.
(Breakage, fire, personal injury or the like may arise.)
●Do not swing around this detector.
(Unexpected personal injury may result.)
WARNING
This symbol isused forshowingpresence of potential dangerthat may
trigger death or serious personal injury.
CAUTION
This symbolisusedforshowingpresence ofpotential dangerthat may
trigger personal injury of medium or minor level.

5
FOR SAFE USE
CAUTION
●Do NOT use this detector for otherthan detectionofleak soundfrompipes.
●Positively mount the battery cover. The batteries will come off, if mounting
of the battery cover is incomplete.
●Do not shelve or leave this detector at a place ofhigh temperature.
(Troubles may arise otherwise.)
●Do not use this detector for a purpose other than water leakdetection.
●This detector is not a completely waterproofed device.
Do not immerse it in the water, and do not use it in the heavy rain.
●This detectorisnot of impact-resistant structure. Do not applystrongimpact
to it. Troubles may arise otherwise.
●Do not try to disassemble this detector.
●Remove the batteries, if it is anticipated that this detector will not be used
for a long time.
●Observe ordinances or regulations of your local government at thetimeof
disposal of this detector.

6
BEFORE USE THE DETECTOR
Make sure conduct simple inspection before use, in order to correctly use
the detector.
Simple inspection is of three items indicated below.
1.
Check of components
2.
Check of batteries
3.
Check of operation of the detector
ATTENTION
We recommend you to have the entire functions of this detectorinspected
by our maintenance department periodically to permit safe and pleasant
useofthis detector astheabove mentionedinspectionissimpleinspection.

7
DETECTOR COMPOSITION
This detector is composed of eight (8) items indicated below. Check if all
the components are provided. If there is any missing item, please contact
your dealer.
●Main Amplifier ........ 1 ●Contact Rod ...... 1
●Extension Contact Rod ........ 2 ●Short Contact Rod (100mm)........ 1
●Headphones ........ 1 ●AA (cell) Alkaline Batteries .......2
●Operation Manual ........ 1 ●Carrying Case....... 1

8
NAME OF EACH PART
Signal Output Jack
Headphone Jack
ON/OFF Switch
LCD
Volume Control
Contact Rod
Volume Control
Battery Case Cover

9
HOW TO USE
1.
HOW TO SET UP
(1)
Connect the sensing bar to the main unit.
(2)
Insert the headphone plug into the jack ( ) in the main unit.
(3)
Locate theintermediate point of the volume control dial at the mark.

10
HOW TO USE
2.
REPLACEMENT OF BATTERIES
If the battery capacity is short, a battery mark ( ) begins to flicker in the
left lower part of the display screen when the ON/OFF switch is pressed.
Replace the batteries with new one in such a case.
Use two alkali dry batteries(LR6).
Positively mount the batterycover.
FSB-8D
CAUTION
If no numerical value or mark is displayed at all bythe LCD when the
power switch is pressed. There isa possibility where the batteries were
completely exhausted orthe detector has failed. Replace batteries and
see what will happen in such a case.
Make sure that batteries are located in the correct polarity.
* Remove batteries from this detector, if it is anticipated that this detector
will not be used for a long time.
FSB-8D
SER I A L N O.

11
HOW TO USE
CAUTION
If batteriesthat are otherthan what isspecifiedbyus were used, troubles
resulting from such use will not be covered by ourwarranty.
If batteries that are otherthan what is specifiedbyus wereused,a difference
in the continuous working time will arise due to the difference in the
battery capacity.
WARNING
Make sure that batteries are located in the correct polarity at the time
of replacement of batteries.
(Burst, fire, personal injury or the like may arise otherwise.)
Do not use batteries of different types in mixture.
(Burst, liquid leakage or the like may arise otherwise.)
Dispose used batteries in accordance with instructions given by your
local government.

12
HOW TO USE
3.
HOW TO USE
(1)
Light fit the tip of the contact rod to a meter, water
tap or the like, and then press the powerswitch.
(2)
The magnitude of the vibration is displayed onthe
LCD, the vibration sound can beheard through the
headphone at the same time.
* The power is OFF when the ON/OFF switch is
released.
If the OUT OF RANGE mark ( )
flickers in the left upper part of the
display screen, it means that the set
display level is exceeded. Open the
battery cover and lower the SENS
switch by one step.
*
If the volume is excessive, turn the
volume control counterclockwise.
If the volume is too small, turn it
clockwise.
*
The numerical value displayed
will remain unchanged, even if
the volume control is turned.
CAUTION
This detectorisnot capable of self-supportingon a paved road. Layit on
theground at a non-wet placethat will not obstruct pedestrians, bicycles,
vehicles, etc.
FSB-8D
SENS

13
10
00
HOW TO USE
4.
SWITCHING THE SENSITIVITY (SENS)
The SENS switch is of three (3) positions. It is used for attenuating the signal
by a certain value for output. [The initial setup is Large ( ).]
Medium ( ): The signal level is about 1/10 of that of Large ( 1).
Small ( ): The signal level is about 1/100 of that of Large ( 1 ).
The LCD displays the output level by numerical value of 00~99.
When the output level exceeds 99, the OUT OF RANGE mark ( ) in the
left upper part of the display screen flickers, indicating that the set display
level is exceeded.
In such a case, lower the degree of amplification of the amplifier bysliding
the SENS switch rightward [ (large) -> (medium) or (medium) -
> (small)].
* The numerical value displayed in the flickering state is not an actually
measured level value.
When the displayed value is of one digit, increase the degree of amplifica-
tion of the amplifier by sliding the SENS switch leftward [ (small) ->
(medium) or (medium) -> (large)].
Large
Medium
Small
SENS

14
HOW TO USE
5.
SENS SWITCH AND VOLUMECONTROL
The volume is separated from the display circuit so that the numerical value
displayed on the LCD will not change when the volume control is turned.
The SENS switch is linked with volume and displayed value.
The volume and displayed value change simultaneously when the switch
position changes.
Link Volume
SENS Switch Indicated Value
SENS

15
SPECIFICATION
■MAIN AMPLIFIER
Pickup : NPC Piezoelectric element
Amplification degree : 55dB
Frequency band : 100Hz~2000Hz
Notch filter : 150, 180Hz
Lowest voltage to operate : 2.0V
Battery warning indication : 2.2V
Operation temperature range : -5~+55C
Consumption current : 22mA (At no signal)
Continuous operation time : Minimum25 hours (Condition: Alkaline
Battery, Indication level 99, +25C)
Battery : Two AA(cell)alkaline batteries 2 pcs
Size (Main amplifier) : 6084207mm
Weight : 250g(Excl.Contact rods, Batteries)
■Contact rod
Size : 340mm
Weight : 125g
■Extension contact rod
Size : 330mm2pcs.
Weight : 128g2
■Short contact rod
Size :100mm
Weight : 34g
■Headphones : Stereo, 24 , Headphone jack
■Total weight (Incl. Carrying case) : Approx. 1.5kg

16
HOW TO STORE THE DETECTOR
Care after use
●Carefully wipe off dust and contaminants and clean the detector after use
of this detector, and store it in the carrying case.
●If this detector was wetted, carefully wipe off the moisture before storage.
●Do not contain anyarticle other than this detector inthe casefor storage of
this detector. Damage and troubles may result otherwise.
If your detector is not used for a long time.
●Assure that all the components including the instruction manual are all
together.
The instruction manual is needed at the time of use of this detector next time.
●Remove batteries.
If batteries are kept contained in this detector for a long time, damage to
the device may result in liquid leakage.
●Do not store this detector at a place of high moisture.

17
PARTS LIST ANDILLUSTRATIONS

PARTS LIST AND ILLUSTRATIONS
< >=Order Code
1 Volume Control <010113>
2 Dust-Control Sheet <054135>
3 Housing (Left) <218109>
4 M36 Sus Screw (4PCS.) <218126>
5 Pick-Up Fixing Axis <218118>
6 O-Ring <218125>
7 Panel Cover <218111>
8 Panel <218112>
9 Black Button <218114>
10 Main PCB & LCD PCB Assy <218101>
11 34 Steel Screw (2PC.) <218127>
12
Battery Spring <218115>
13
Pick-Up Sensor Assy <218103>
14
Housing (Right) <218108>
15 312 Sus Screw (4PCS.) <218128>
16 316 Sus Screw (1PC.) <218129>
17 Battery Case Cover <218110>
Table of contents
Popular Security Sensor manuals by other brands

LST
LST FI750/RF/OT quick start guide

B.E.G. LUXOMAT
B.E.G. LUXOMAT RC-plus Operating and mounting instructions

Wilson Electronics
Wilson Electronics 2E7501 user guide

DBI SALA
DBI SALA RPD User instruction manual

PCB Piezotronics
PCB Piezotronics ICP W138A01/038CY003AC Installation and operating manual

GE
GE Baker Hughes Reuter-Stokes Flame Tracker... Operation and maintenance manual

BRINKS
BRINKS 7001 Series Easy installation instructions

Omron
Omron E3X-HD11 instruction sheet

Jasco
Jasco CD-1595 Operation manual

Honeywell
Honeywell Viewguard DUAL AM FAI installation instructions

B.E.G.
B.E.G. LUXOMAT PD5-M-1C-Clip Installation and operating instruction

APsmart