manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Galvin Specialised
  6. •
  7. Kitchen & Bath Fixture
  8. •
  9. Galvin Specialised CliniLever TCWTJ150PC Instruction sheet

Galvin Specialised CliniLever TCWTJ150PC Instruction sheet

CliniLever®Healthcare Tapware
PRODUCT CODES:
- TCWTJ150PC
- TCWTJ80PC
SPECIFICATIONS
−The Galvin Specialised CliniLever®product range is primarily used for hand washing applications in
hospitals, aged care facilities, schools and in-home care.
−CliniLever®products provide state of the art features to comply with the latest healthcare guidelines.
−The dual levers for on/off, hot and cold temperature have a straight forward operation which simplifies
hand washing.
−Our highly sought after lever handle design can easily be operated with wrists or elbows.
−The main body is made of solid dezincification resistant (DR) brass rod, with a DR brass fixed outlet.
−Quick action SBA’s include brass jumper valve / ceramic cartridge components, with red and blue
indicator buttons on 80mm lever action handles.
IMPORTANT: All CliniLever
®
healthcare taps are tested in accordance with AS/NZS 3718 and leave our
premises in good working order.
TECHNICAL DATA
Inlet G5/8 BSP- Male
Outlet N/A
Headwork
Jumper Valve
Working Pressure Range (kPa) Min 50
Max 500
Working Temperature (°C) Min 5
Max 85
Nominal Flow Rate (LPM) N/A
Finish Chrome
NOTE:
Galvin Specialised continually strive to improve their products. Specifications may change without notice.
PRE-INSTALLATION
MOUNTING DETAILS
Wall body
−Wall body must be G5/8” FI and body should be between
0 and 13mm behind the finished wall surface.
TOOLS REQUIRED
−Spanner and hex key
−Thread tape
INSTALLATION
IMPORTANT: Galvin Specialised products must be installed in accordance with these installation instructions and
in accordance with AS/NZS 3500, the PCA and your local regulatory requirements. Water and/or electrical supply
conditions must also comply to the applicable national and/or state standards. Failing to comply with these
provisions shall void the product warranty and may affect the performance of the product.
1. Fit spindle assembly
−Remove handle and flange from spindle
assembly.
−Ensure jumper valve and fibre washer are fitted to
spindle assembly.
−Screw entire assembly into the wall body.
−Fasten securely using a spanner.
2. Fit wall flange
−Ensure o-ring is fitted to the bottom of the wall
flange, and then hand-tighten the wall flange
onto the threaded sleeve.
3. Fit handle
−Ensure the spindle is in the closed position and
firmly press the CliniLever®lever handle onto
the spindle in the desired orientation.
−Check CliniLever®lever handles for operation. It
should turn freely for a full ¼ turn.
−Secure the handle in position using the supplied
washer and stainless steel cap screw.
4
.
Fit water temperature indicator & testing
−Once CliniLever®lever handle is secure; fit the
appropriate water temperature indicator.
−Once temperature indicator is fitted, check the
operation of the unit and inspect for any leaks.
TROUBLESHOOTING
PROBLEM CAUSE RECTIFICATION
Taps are dripping water Jumper valves are worn or damaged Replace jumper valve
Tap seat is damaged Refurbish tap seat using a reseating
tool.
Water is leaking from spindle O-ring on jumper valve spindle is
damaged or worn Replace o-ring
Water is not flowing from tap Water is turned off Turn on water
Aerator or flow regulator is blocked by
debris Remove aerator and/or flow
regulator from tap and remove
debris. Install an inline strainer.
Spindle is difficult to turn
(jumper valve) Build up of scale on spindle, spindle
worn or o-ring has been damaged Remove jumper valve, clean and
regrease. Replace o-ring. Complete
SBA may need to be replaced.
Handle is loose Screw has come loose Tighten handle screw
Flange does not screw down onto
wall surface Wall bodies are set too far out Re-position tap bodies
SERVICE AND MAINTENANCE
JUMPER VALVE TAPWARE
1. Turn off the water supply and turn on the tap handle to drain water from the bodies.
2. Remove the temperature indicator from the handle.
3. Remove the handle from the tap.
4. Unscrew the top assembly from the body.
5. Check the o-ring on the spindle and the jumper valve for wear and damage. Replace if required.
6. Clean the spindle and body of debris.
7. Place a new o-ring (if required) onto the spindle and re-grease with potable water approved grease.
8. Re-assemble top assembly. Follow the product installation guidelines for the relevant product
re-assembly method.
Version 1, 3 November 2016, Page 4
WARRANTY
The warranty set forth herein is given expressly and is the only warranty given by the Galvin Engineering Pty Ltd.
With respect to the product, Galvin Engineering Pty Ltd makes no other warranties, express or implied. Galvin
Engineering Pty. Ltd. hereby specifically disclaims all other warranties, express or implied, including but not limited
to the implied warranties of merchantability and fitness for a particular purpose.
Galvin Engineering Pty Ltd products are covered under our manufacturer’s warranty available for download from
www.galvinengineering.com.au Galvin Engineering Pty Ltd expressly warrants that the product is free from
operational defects in workmanship and materials for the warranty period as shown on the schedule in the
manufacturer’s warranty. During the warranty period, Galvin Engineering will replace or repair any defective
products manufactured by Galvin Engineering without charge, so long as the terms of the Manufacturer’s warranty
are complied with.
The remedy described in the first paragraph of this warranty shall constitute the sole and exclusive remedy for
breach of warranty, and Galvin Engineering Pty Ltd shall not be responsible for any incidental, special or
consequential damages, including without limitation, lost profits or the cost of repairing or replacing other property
which is damaged if this product does not work properly, other costs resulting from labour charges, delays,
vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions, chemical,
electrical or any other circumstances over which Galvin Engineering has no control. This warranty shall be
invalidated by any abuse, misuse, misapplication, improper installation or improper maintenance or alteration of the
product.

This manual suits for next models

1

Other Galvin Specialised Kitchen & Bath Fixture manuals

Galvin Specialised Ezy-Wash TF85-J User manual

Galvin Specialised

Galvin Specialised Ezy-Wash TF85-J User manual

Galvin Specialised Ezy-Wash TF78WC-ESS Instruction sheet

Galvin Specialised

Galvin Specialised Ezy-Wash TF78WC-ESS Instruction sheet

Popular Kitchen & Bath Fixture manuals by other brands

Dallmer 400E manual

Dallmer

Dallmer 400E manual

Home Decorators Collection GT25 O Series Assembly instructions

Home Decorators Collection

Home Decorators Collection GT25 O Series Assembly instructions

Pegasus 67125-8004 installation instructions

Pegasus

Pegasus 67125-8004 installation instructions

CRISTINA FOIL CRIFL220 installation instructions

CRISTINA

CRISTINA FOIL CRIFL220 installation instructions

Hans Grohe Metris 31450000 manual

Hans Grohe

Hans Grohe Metris 31450000 manual

KS BAIONA Series Operation and installation guide

KS

KS BAIONA Series Operation and installation guide

Grohe EUROSTYLE COSMOPOLITAN 31 124 manual

Grohe

Grohe EUROSTYLE COSMOPOLITAN 31 124 manual

Gessi RETTANGOLO K 53002 manual

Gessi

Gessi RETTANGOLO K 53002 manual

Hans Grohe Talis Loop 04700 5 Series Installation/User Instructions/Warranty

Hans Grohe

Hans Grohe Talis Loop 04700 5 Series Installation/User Instructions/Warranty

Hans Grohe Metris 14820 1 Series Installation/User Instructions/Warranty

Hans Grohe

Hans Grohe Metris 14820 1 Series Installation/User Instructions/Warranty

Moen Hilliard 84532 installation guide

Moen

Moen Hilliard 84532 installation guide

Artecristal ELISEO quick start guide

Artecristal

Artecristal ELISEO quick start guide

Lefroy Brooks M1-5111 Installation, operating,  & maintenance instructions

Lefroy Brooks

Lefroy Brooks M1-5111 Installation, operating, & maintenance instructions

Lefroy Brooks X1-3000 Installation, operating,  & maintenance instructions

Lefroy Brooks

Lefroy Brooks X1-3000 Installation, operating, & maintenance instructions

SUMERAIN S3235 Series installation guide

SUMERAIN

SUMERAIN S3235 Series installation guide

Graff LM40-VS installation instructions

Graff

Graff LM40-VS installation instructions

Inta IR180CP Installation and maintenance instructions

Inta

Inta IR180CP Installation and maintenance instructions

Nabis A05028 Instruction & Warranty Booklet

Nabis

Nabis A05028 Instruction & Warranty Booklet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.