Geisinger GBTVAT-01 User manual

These operang instrucons belong exclusively to this product.
It contains important informaon on commissioning and
handling. Pay aenon to this, even if you pass this product on
to third pares. You should therefore archive these operang
instrucons for future reference.
1. introducon
Dear customer, thank you for purchasing this product. You have
acquired a product that has been built according to the state
of the art.
In order to maintain this status and to ensure safe operaon,
you as the user must observe these operang instrucons!
2. safety instrucons
In the event of damage caused by non-observance of these
operang instrucons, the guarantee expires!
For further damages we do not accept liability!
We assume no liability for property damage or personal injury
caused by improper handling or failure to observe the safety
instrucons. In such cases, any guarantee claim will expire.
For safety reasons, unauthorized modicaons and / or chan-
ges to the product are not permied. Pay aenon to a proper
commissioning. Please refer to these operang instrucons.
3. Intended Use
The brew group thermometer shows the brewing temperature
shortly before the coee puck. The brew group thermometer is
only for use in E61 brew groups with M6 inspecon screw.
The thermometer must not be submerged in water.
4. Installaon
CAUTION:
The p of the screw connecon is very sensive!
1. Make sure that the coee / espresso machine has cooled
down.
Cauon, risk of burns!
2. With the machine turned o, ush your group head to
relieve the pressure.
3. Loosen the M6 screw with the tool provi-
ded for this purpose (not included), plea-
se make sure that you also remove the seal.
4. Carefully remove the thermometer from the packaging.
5. Make sure that the sealing ring is on the screw connec-
on.
6. Carefully screw the thermometer into the M6 thread of
the machine. Take a 10 mm open-ended wrench (not in-
cluded) and ghten the screw connecon. (max. 0,9 Nm)
7. Use the supplied Allen key to loosen the small screw
(approx. 1/2 turn) unl you can easily turn the thermo-
meter.
8. Align the thermometer
9. Tighten the small screw again slightly.
10. Check the ghtness by pressing the
Rinse the grouphead with a blind basket.
Instrucon manual - ENGLISH- GBTVAT-01
Group head thermometer for E61 brew groups

6. calibraon
already calibrated at the factory
1. The thermometer is only suitable for calibraon in a slush
ice soluon (60% crushed ice and 40% tap water). Do not
try to calibrate in any other way.
2. Press the CAL buon for 2 seconds.
3. The display remains blank for 2 seconds.
4. 0.00 ° C or 32.0 ° F are displayed.
5. The thermometer is now calibrated.
Note: To avoid accidental recalibraon, this funcon is only
enabled at a water temperature of 30 to 34 ° F. ERR appears for
2 seconds if the water is not within this range.
7. Technical specicaons
Measuring range: -20 bis + 230 ° C
Display size: 2,2 B x 1,3 H (cm)
Baery: 1 LR44 enthalten
Unit of measurement ° F / ° C
Auto-o: nach 10 Minuten
Housing material: 304 Edelstahlgehäuse / ABS
Stand: 23.02.2021
5. Change the baery
Replace the baery when the LCD display is weak becomes.
1. Remove the baery cover at the boom with a coin.
(das schwergängige Önen des Baeriedeckels stellt
keinen Mängel dar)
(The dicult opening of the baery cover is not a defect)
2. Insert a LR44 baery with the + side up.
3. Put the baery compartment cover back on.
Baery take-back
• Baeries must not be disposed of with household waste.
• The consumer is legally obliged to return baeries
aer use, e.g. at public collecon points or where such
baeries are sold.
• Baeries containing pollutants are marked with the sym-
bol „crossed out garbage can“ and one of the chemical
symbols.
Baery notes
• Baeries do not belong in the hands of children. Never
leave baeries lying around; there is a risk of them being
swallowed by children or pets
• Baeries must never be short-circuited, disassembled or
thrown into re. There is a risk of explosion!
• Leaking or damaged baeries can cause acid burns on
contact with the skin, so use suitable protecve gloves
in this case.
• When changing the baeries, only idencal baeries may
be used.
• Make sure that the polarity is correct when inserng the
baery.
• If the device is not going to be used for a long me (e.g.
storage), remove the inserted baery to avoid damage
from leaking baeries.
disposal
Electronic devices are recyclable and do not belong in the
household waste. At the end of its service life, dispose of the
product in accordance with the applicable statutory provisions.
Remove any inserted baeries and dispose of them separately
from the product.

°C
°F
ON
+/S
OFF
Zeigt die aktuelle Temperatur
shows the current temperature
Thermometer schaltet aus
Thermometer switches o
Display zeigt 0 sek.
Display shows 0 sec.
bestätigen der eingestellten Zeit
conrm the set time
Startet den Timer
Starts the Timer
beendet das Blinken
stops ashing
Display zeigt für eine Sekunde die eingestellte
Zeit an dann wieder die Temperatur
The display shows the set time for one
second and then the temperature again
Sobald der Timer abgelaufen ist blinkt das Display und Piepton ertönt
As soon as the timer has expired, the display ashes / beep
Display wechselt zur Temperaturanzeige
The display changes to the temperature display
Einstellen des Timers von 0 bis 59 Sek.
Setting the timer from 0 to 59 seconds.
ON/OFF
ON/OFF
+/S
+/S
7. Funcon descripon
Geisinger - Espresso in Perfekon
Bernd Geisinger
Schloßbühl 12
88348 Bad Saulgau
Tel.: 07583/941063
Email: info@geisinger.eu
www.geisinger.eu

Dear customer (m/f/d)!
We would be delighted if you could send us pictures of us
purchased products in acon.
We would also be happy to receive reviews (including names if
you like).
Please send us the pictures / reviews to
info@geisinger.eu
You can also rate the purchased items directly in our shop
Thanks in advance
Bernd Geisinger
Small print (unfortunately must be)
By sending the pictures, I agree that Bernd Geisinger may publish the pictures and use them for adver-
sing purposes. This consent can be revoked at any me - even in part - and is otherwise unlimited in
me.
This manual suits for next models
2
Popular Kitchen Appliance Accessories manuals by other brands

KitchenAid
KitchenAid Architect Series II KCMS1555SSS install guide

Rev-A-Shelf
Rev-A-Shelf 5730 Series installation instructions

Cleveland
Cleveland Convotherm OEB-6.10 Specification sheet

DCS
DCS MOTTK30 user manual

eta
eta 002898050 Instructions for use

KitchenAid
KitchenAid 12884405 Dimensions and installation