manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Geisinger
  6. •
  7. Kitchen Appliance Accessories
  8. •
  9. Geisinger GBTVAT-01 User manual

Geisinger GBTVAT-01 User manual

These operang instrucons belong exclusively to this product.
It contains important informaon on commissioning and
handling. Pay aenon to this, even if you pass this product on
to third pares. You should therefore archive these operang
instrucons for future reference.
1. introducon
Dear customer, thank you for purchasing this product. You have
acquired a product that has been built according to the state
of the art.
In order to maintain this status and to ensure safe operaon,
you as the user must observe these operang instrucons!
2. safety instrucons
In the event of damage caused by non-observance of these
operang instrucons, the guarantee expires!
For further damages we do not accept liability!
We assume no liability for property damage or personal injury
caused by improper handling or failure to observe the safety
instrucons. In such cases, any guarantee claim will expire.
For safety reasons, unauthorized modicaons and / or chan-
ges to the product are not permied. Pay aenon to a proper
commissioning. Please refer to these operang instrucons.
3. Intended Use
The brew group thermometer shows the brewing temperature
shortly before the coee puck. The brew group thermometer is
only for use in E61 brew groups with M6 inspecon screw.
The thermometer must not be submerged in water.
4. Installaon
CAUTION:
The p of the screw connecon is very sensive!
1. Make sure that the coee / espresso machine has cooled
down.
Cauon, risk of burns!
2. With the machine turned o, ush your group head to
relieve the pressure.
3. Loosen the M6 screw with the tool provi-
ded for this purpose (not included), plea-
se make sure that you also remove the seal.
4. Carefully remove the thermometer from the packaging.
5. Make sure that the sealing ring is on the screw connec-
on.
6. Carefully screw the thermometer into the M6 thread of
the machine. Take a 10 mm open-ended wrench (not in-
cluded) and ghten the screw connecon. (max. 0,9 Nm)
7. Use the supplied Allen key to loosen the small screw
(approx. 1/2 turn) unl you can easily turn the thermo-
meter.
8. Align the thermometer
9. Tighten the small screw again slightly.
10. Check the ghtness by pressing the
Rinse the grouphead with a blind basket.
Instrucon manual - ENGLISH- GBTVAT-01
Group head thermometer for E61 brew groups
6. calibraon
already calibrated at the factory
1. The thermometer is only suitable for calibraon in a slush
ice soluon (60% crushed ice and 40% tap water). Do not
try to calibrate in any other way.
2. Press the CAL buon for 2 seconds.
3. The display remains blank for 2 seconds.
4. 0.00 ° C or 32.0 ° F are displayed.
5. The thermometer is now calibrated.
Note: To avoid accidental recalibraon, this funcon is only
enabled at a water temperature of 30 to 34 ° F. ERR appears for
2 seconds if the water is not within this range.
7. Technical specicaons
Measuring range: -20 bis + 230 ° C
Display size: 2,2 B x 1,3 H (cm)
Baery: 1 LR44 enthalten
Unit of measurement ° F / ° C
Auto-o: nach 10 Minuten
Housing material: 304 Edelstahlgehäuse / ABS
Stand: 23.02.2021
5. Change the baery
Replace the baery when the LCD display is weak becomes.
1. Remove the baery cover at the boom with a coin.
(das schwergängige Önen des Baeriedeckels stellt
keinen Mängel dar)
(The dicult opening of the baery cover is not a defect)
2. Insert a LR44 baery with the + side up.
3. Put the baery compartment cover back on.
Baery take-back
• Baeries must not be disposed of with household waste.
• The consumer is legally obliged to return baeries
aer use, e.g. at public collecon points or where such
baeries are sold.
• Baeries containing pollutants are marked with the sym-
bol „crossed out garbage can“ and one of the chemical
symbols.
Baery notes
• Baeries do not belong in the hands of children. Never
leave baeries lying around; there is a risk of them being
swallowed by children or pets
• Baeries must never be short-circuited, disassembled or
thrown into re. There is a risk of explosion!
• Leaking or damaged baeries can cause acid burns on
contact with the skin, so use suitable protecve gloves
in this case.
• When changing the baeries, only idencal baeries may
be used.
• Make sure that the polarity is correct when inserng the
baery.
• If the device is not going to be used for a long me (e.g.
storage), remove the inserted baery to avoid damage
from leaking baeries.
disposal
Electronic devices are recyclable and do not belong in the
household waste. At the end of its service life, dispose of the
product in accordance with the applicable statutory provisions.
Remove any inserted baeries and dispose of them separately
from the product.
°C
°F
ON
+/S
OFF
Zeigt die aktuelle Temperatur
shows the current temperature
Thermometer schaltet aus
Thermometer switches o
Display zeigt 0 sek.
Display shows 0 sec.
bestätigen der eingestellten Zeit
conrm the set time
Startet den Timer
Starts the Timer
beendet das Blinken
stops ashing
Display zeigt für eine Sekunde die eingestellte
Zeit an dann wieder die Temperatur
The display shows the set time for one
second and then the temperature again
Sobald der Timer abgelaufen ist blinkt das Display und Piepton ertönt
As soon as the timer has expired, the display ashes / beep
Display wechselt zur Temperaturanzeige
The display changes to the temperature display
Einstellen des Timers von 0 bis 59 Sek.
Setting the timer from 0 to 59 seconds.
ON/OFF
ON/OFF
+/S
+/S
7. Funcon descripon
Geisinger - Espresso in Perfekon
Bernd Geisinger
Schloßbühl 12
88348 Bad Saulgau
Tel.: 07583/941063
Email: info@geisinger.eu
www.geisinger.eu
Dear customer (m/f/d)!
We would be delighted if you could send us pictures of us
purchased products in acon.
We would also be happy to receive reviews (including names if
you like).
Please send us the pictures / reviews to
info@geisinger.eu
You can also rate the purchased items directly in our shop
Thanks in advance
Bernd Geisinger
Small print (unfortunately must be)
By sending the pictures, I agree that Bernd Geisinger may publish the pictures and use them for adver-
sing purposes. This consent can be revoked at any me - even in part - and is otherwise unlimited in
me.

This manual suits for next models

2

Popular Kitchen Appliance Accessories manuals by other brands

KitchenAid Architect Series II KCMS1555SSS install guide

KitchenAid

KitchenAid Architect Series II KCMS1555SSS install guide

Rev-A-Shelf 5730 Series installation instructions

Rev-A-Shelf

Rev-A-Shelf 5730 Series installation instructions

Cleveland Convotherm OEB-6.10 Specification sheet

Cleveland

Cleveland Convotherm OEB-6.10 Specification sheet

DCS MOTTK30 user manual

DCS

DCS MOTTK30 user manual

eta 002898050 Instructions for use

eta

eta 002898050 Instructions for use

KitchenAid 12884405 Dimensions and installation

KitchenAid

KitchenAid 12884405 Dimensions and installation

Amana UCTK27 installation instructions

Amana

Amana UCTK27 installation instructions

miogo MRPM1 Instructions for use

miogo

miogo MRPM1 Instructions for use

Schweigen Isodrive 900 installation guide

Schweigen

Schweigen Isodrive 900 installation guide

Baratza Forte Smart Dose manual

Baratza

Baratza Forte Smart Dose manual

Momax smart HL6S instruction manual

Momax

Momax smart HL6S instruction manual

Dacor ATKR30SR installation instructions

Dacor

Dacor ATKR30SR installation instructions

Cadco TG320 Guidelines & suggestions

Cadco

Cadco TG320 Guidelines & suggestions

Concept2 SS1000 quick guide

Concept2

Concept2 SS1000 quick guide

Jenn-Air JFC2290VTB1 Dimensions and installation

Jenn-Air

Jenn-Air JFC2290VTB1 Dimensions and installation

glorex cera alba manual

glorex

glorex cera alba manual

GE JX46AL installation instructions

GE

GE JX46AL installation instructions

emaux EM2831 Manual Installation

emaux

emaux EM2831 Manual Installation

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.