manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Generic
  6. •
  7. Thermostat
  8. •
  9. Generic BHT-1000 User manual

Generic BHT-1000 User manual

Model:BHT-1000
Heating Room Thermostat
User Guide
Welcome
Thank you for your purchase.
Thermostat
Screws
Installation/programming manual
Wall plate
Your thermostat carries an 18 month warranty from
date of purchase. Service outwith the warranty
period may incur a charge.
Contents
Warranty
Your thermostat
Features
Simple installation
Acrylic face plate
Large, backlit display
Sleek, contemporary design
Elegant chrome frame
Feather touch control panel
5+2 six period per day programming
Simple, one-touch temperature control over-ride.
Pre-set temperatures maintained within +/- 1°C
Internal and external sensors allow control of
both air and/or floor temperatures
Suitable for installation in a standard single pattress
box or European 60mm round box
RS485/MODBUS communication optional
Home screen quick reference
Operation/programming
1. Power on/off
Press to turn on/off.
2. Adjusting/setting the temperature
Press to set the desired temperature.
3. Adjusting/Setting the clock
5.Adjusting/setting the program schedules
The BHT-1000 range has been developed to
control electric underfloor or water heating systems.
These units are designed for use in commercial,
industrial, civil and domestic properties.
Power Up DownClock
Mode
Time
Timing on/off
AM/PM
Room Temp.
Set Temp.
Manual
Lock Period
Floor Temp.
Heating On
Programmable
Temp.Week
Technical Data
Sensor:NTC
Accuracy:±1℃
Power Consumption:< 1.5W
Timing Error:<1%
Power Supply:95 ~ 240VAC, 50 ~60Hz
Current Load:3A(water heating),
16A(electric heating)
Shell material:PC+ABS (flame retardant)
Dimension:86x86x13.3mm
Ambient Temp.:0-45℃,5-95%RH
(Non-condensing)
Storage Temp.:-5-55℃
Installation Hole distance: 60mm
Set Temp. Range:5-35℃
Room Temp. Range:5-99℃
Your new thermostat will provide uniform and
comfortable temperature control throughout
every room in your property. We bring together
technology, craftsmanship and the highest quality
materials to provide you with a safe, reliable
product combined with sleek, contemporary design.
Please read this installation/programming manual
for comprehensive instructions on installing and
operating your thermostat. Please ensure a
suitably qualified person installs your thermostat
and complies with all local regulations.
2.5m External (Floor) Sensor
1pc
1pc
1pc
1pc
1pc
Touch the icon to set minute, hour and weekday
(1 = Monday, 2 = Tuesday etc.) by using the
arrows. Press once more to confirm and exit.
4.Locking your thermostat
Press and hold the and arrows for 5 seconds
to lock/unlock your thermostat.
Your thermostat provides six scheduled heating
periods each day – three Comfort periods - 1, 3 & 5
(the temperature required when room is occupied)
and three Economy periods – 2, 4 & 6 (the
temperature required when room is unoccupied).
You can set both the time and temperature for each
of these six daily periods. Adjusting/setting the
schedules can only be carried out when in program
mode;
Touch M (mode) to change between manual mode
and programme mode. In manual mode,
Eco-Term sp. z o.o. ul. Mały Płaszów 10 30-720 Kraków www.eco-term.eu
Eco-Term Group s.r.o Orgovánová 2 917 02 Trnava www.eco-term.net
Installing your thermostat
6. System function settings
With power off, press and hold both M and for 5
seconds to enter the System Functions. Press M to
scroll through the available functions, and use the
and arrows to change the available options.
Your thermostat will automatically exit the System
Functions settings after approximately 15 - 20
seconds of inactivity. All settings are automatically
Wiring your thermostat
Wiring your thermostat
Please note:
1.“Err” on your thermostat indicates a fault without the external (floor) sensor.
Your thermostat will be inoperative until the error is rectified.
2. When sensor selection is “AL” (option 3 above) the room temperature will
be displayed on your thermostat by default. The floor temperature can be
displayed temporarily by pressing the button for three seconds. Your
thermostat will revert to display the room temperature after several seconds.
Your thermostat is suitable for installation within
a standard 86mm pattress box or European 60mm
round pattress box.
will show in the bottom left of the screen.
Touch and hold the icon until the weekday
schedule settings appear (1 2 3 4 5 will show
along the top of the screen).
Use the and arrows to adjust the time for
the 1st (Comfort) period
Press the icon and use the and arrows
to set the temperature for the 1st period.
Repeat this process for periods 2 – 6.
Press the icon once more to enter the
weekend schedule settings (6 & 7 will show along
the top of the screen).
Repeat the above process to set the weekend
schedule. Press once more to confirm and exit.
Default settings for program schedule
Time display
WEEKDAY (MON. – FRI.)
WEEKEND (SAT. – SUN.)
TIME
TEMP.
TIME
TEMP.
Period 1 (Comfort)
06.00 waken
20°C
06.00 waken
20°C
Period 2 (Economy)
08.00 leave
15°C
08.00 leave
20°C
Period 3 (Comfort)
11.30 home
15°C
11.30 home
20°C
Period 4 (Economy)
13.30 leave
15°C
13.30 leave
20°C
Period 5 (Comfort)
17.00 home
22°C
17.00 home
°C
Period 6 (Economy)
22.00 bed
15°C
22.00 bed
15°C
15
Default settings above assume a 5+2 (day) weekly
program.
Please note:
Do not over-tighten the terminals in your thermostat
as damage may occur.
Code Function Setting & options Default
1Air temperature
calibration Range is -9°C to +9°C for internal sensor -2
2Switching
differential
Range is 0°C to 5°C
The number of degrees above/below set temperature before
switching on/off
When default is set to 1°C the thermostat will switch on 0.5°C
below the set temperature and will switch off 0.5°C above the
set temperature.
1
3Button locking 00: = All buttons will lock except the Power button
01: = All buttons will lock 01
4Sensor selection
In = control temperature using the internal sensor
Ou = control temperature using the external (floor) sensor
Al = control temperature using internal sensor to control
temperature, and external sensor to limit the floor temperature
Remark: Please make sure the right sensor. If choose the
wrong or bad one, LCD will display Err.
In for GA
Al for GB
5Minimum
temperature setting
Range is 5°C - 15°C. 5
6Maximum
temperature setting
Range is 15°C - 45°C. 35
712/24 hour clock 00: 12h: = 12 Hour clock
01: 24h: = 24 hour clock 01
8Display Mode 00:display both set temp. and room temp.
01:display set temp. only 00
9
Minimum floor
temperature
protection setting
Range is 0°C - 20°C.
When chosen floor temperature is reached, the system will
automatically switch off. This facility is used to protect delicate
floor coverings.
0
A
Maximum floor
temperature
protection setting
Range is 10°C - 70°C.
When chosen floor temperature is reached, the system will
automatically switch off. This facility is used to protect delicate
floor coverings.
26
BBacklight On Time 3-99S. 10
C
Return to factory
setting 00: Normal Status 01:Return to factory setting 00
15
AC95~230V
IP20
NL
1234
M
Close Open 5
6
NTC
GA
L1 N1
LOAD
IP20
NL
1234
NTC
5
6
GB
AC95~230V
GA for water heating and GB for electric heating;
External Sensor is optional.
The electrical connections can be made only by a certified
electrician.
Step 1. Keep power off. See Fig 1.
Fig 1
Step 2. Remove the mounting Plate. See Fig 2.
Fig 2
Step 3. Connect power supply, load and external (floor) sensor
into the appropriate terminals if there is external sensor.
(see “Wiring your thermostat” for details and Fig 3).
Fig 3
Step 4. Fix the mounting plate into the wall with screws in
the box. See Fig 4
Fig 4
Step 5. Fasten body of thermostat and the mounting plate
through the groove. See Fig 5.
Fig 5
Step 6. Installation complete. See Fig 6.
Fig 6
RISK OF ELECTRICAL SHOCK.
Disconnect/isolate
power supply prior to making electrical connections.
Contact with high voltage components can cause electrical
shock, severe injury or death.
Orgovánová 2 917 02 Trnava www.eco-term.net
Eco-Term sp. z o.o. ul. Mały Płaszów 10 30-720 Kraków www.eco-term.eu
Eco-Term Group s.r.o Orgovánová 2 917 02 Trnava www.eco-term.net
made in China

Popular Thermostat manuals by other brands

POLA HP43 Handbook

POLA

POLA HP43 Handbook

Adax Glamox heating WT2 Series user guide

Adax

Adax Glamox heating WT2 Series user guide

SyxthSense DAEA80 quick start guide

SyxthSense

SyxthSense DAEA80 quick start guide

Braeburn 3020 Installer's guide

Braeburn

Braeburn 3020 Installer's guide

Carrier A07051 installation instructions

Carrier

Carrier A07051 installation instructions

HouseWarmer HWTMV-1 installation instructions

HouseWarmer

HouseWarmer HWTMV-1 installation instructions

ritetemp 6010 Operation guide

ritetemp

ritetemp 6010 Operation guide

Danfoss ECtemp 535 user guide

Danfoss

Danfoss ECtemp 535 user guide

Lennox iHarmony 17A30 Installation and setup guide

Lennox

Lennox iHarmony 17A30 Installation and setup guide

Danfoss HP8211-1RJ installation instructions

Danfoss

Danfoss HP8211-1RJ installation instructions

AKO 226.0120 Series Mounting and Servicing Instructions

AKO

AKO 226.0120 Series Mounting and Servicing Instructions

Heimeier INSTAT + 3R User and installation guide

Heimeier

Heimeier INSTAT + 3R User and installation guide

ComfortPro Systems AquaHeat ProZone installation guide

ComfortPro Systems

ComfortPro Systems AquaHeat ProZone installation guide

Aube Technologies TH108 user guide

Aube Technologies

Aube Technologies TH108 user guide

Bosch FW 100 Installation and operating instructions

Bosch

Bosch FW 100 Installation and operating instructions

Honeywell CM921 user guide

Honeywell

Honeywell CM921 user guide

Comet Z-Wave 700226 quick start guide

Comet

Comet Z-Wave 700226 quick start guide

Vimar 01911 Instruction handbook

Vimar

Vimar 01911 Instruction handbook

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.