Gesteknik HA323 Series User manual

1
HA323 User Manual
HA323 series thermostats are used to control electric heating system.
It’s showing the following items: working status(heating ),output display( ), room
temperature(Celsius + Fahrenheit), device temperature, temperature setting point, time etc.
Key pad includes: on/off( ), mode( )、clock()and temperature setting(▲
▼).
Features Display
room temperature setting
equipment temperature setting
recovery
low temperature protection
clock, timing on/off, 4period programming
blue back light
external sensor & internal sensor optional
heating
heaters On
working/rest day 4 periods
room temperature
room temperature setting point
equipment temperature
clock
week
Specification
sensing element: NTC
accuracy: ±1 ℃
temperature setting:
5~35℃(internal sensor) [41-95℉]
5~90℃(single external sensor)[41-194℉]
operation temperature: 0~45℃
humidity: 5~95% RH(non-condensing)
key: touch key
consumption: < 2 W
power supply: AC85~260V,50/60Hz
terminals: connect wire 1×4 mm2
switch current rating: 16 A(resistive load)
6 A(inductive load)
housing: PC+ABS
dimension: 90×88×15.5 mm(W×H×D)
hole pitch: 60 mm
protection class: IP 30
Operation
On/Off &Setting temperature
On/Off: Press “ ” to turn on, press “ ” again to turn off thermostat and its output.
Setting temperature: When power on, press “” to reduce set-point, press “” to raise set-point. (0.5℃ / 1℉
changed once)
Control of heating equipment: When the room temperature is lower 1℃ /2℉than the set-point , the thermostat opens
the heating equipment, and the LCD displays “ ”; When the room temperature reaches the set-point, thermostat closes
the heating equipment, the symbol “ ” disappear on the LCD.
Sensing mode selection
Turn off the thermostat, press “M+” 10 seconds, when display “1” at top right corner, and then press “” or “” to
choose the sensing mode “02, 03, 04 ” displayed in the area of temperature display, parameter as below:
02: floor sensor
03: room sensor and floor sensor (under this mode, please connect the floor sensor, otherwise the thermostat display error)
04: room sensor
Error :
single room/floor sensor fault, display E1; double sensor, room sensor fault, display E1, floor sensor fault, display E2.
Note:
1 the length of floor sensor wire is within 20m
2 when temperature higher than 55℃(131℉), display “HI”,lower than 0℃(32℉) display “LO”.
Manual mode, timing on/off and 4periods selection
turn on thermostat,press“ ” 3seconds,LCD will display “XX”,press “▲” or “▼” to select, 01 means manual mode,
temperature is no change after setting well, 02 means timing on/off, 03 means 4periods mode.
Clock and timing on/off setting
Press “” ,and “hh” of “hh:mm” flash, press “▲” or “▼” to adjust hour, press “”, “mm” flash, press “▲” or “▼” to
adjust minute; Press “”, “week” flash, press “▲” or “▼” to adjust Mon to Sun.
Timer on/off setting: Press “”, till to display “ON” and “hh” flash, press “▲” or “▼” to adjust hour of timer on. Press
“”, “mm” flash, press “▲” or “▼” to adjust minute of timer on. Press “”, “OFF” appear and “hh” flash, press “▲” or “▼” to
adjust hour of timer off. Press “”, “mm” flash, press “▲” or “▼” to adjust minute of timer off. The settings will be valid only
one day.
Cancel timing on/off function: two ways, 1 set hour and minute of timing on/off into “--”; 2 according to “Manual mode,
timing on/off and 4periods selection” to select 01 or 03.
Working day/rest day 4periods setting
Working day setting: first period:press“” till display “1”and“MON TUE WED THU FRI”,and then press“▲” or “▼”to

2
set the time; press “”, then“℃” display, the temperature is the set-point of the first period, the same setting way for other
periods.
Rest day setting: press“” till display“1” and “SAT SUN”, the same setting way as working day.
Please set different value at different periods to avoid the thermostat abnormal
The factory default value as follow:
Working day / rest day
period 1 period 2 period 3 period 4
start / temp start / temp start / temp start / temp
Workingday (Mon - Fri)
7:00 15℃(59℉)
17:00 22℃(72℉)
21:00 20℃(68℉)
22:00 18℃(64℉)
rest day(Sat - Sun) 7:00 22℃(72℉)
9:00 20℃(68℉)
17:00 22℃(72℉)
22:00 18℃(64℉)
Cancel working day/rest day 4periods program, please change thermostat into manual mode(01) or timing on/off
mode(02).
Key lock function
Key lock: thermostat will be locked after 30seconds without operation
Unlock: press“ ” and “” 10seconds, lock is invalid.
Reading/setting the temperature of equipment
Reading temperature: turn on thermostat, press “M”, “Room” disappear, display “ ” and “ ” flash, then “XX℃”is
the temperature of equipment, S1 type without the function
Setting the protection temperature: turn off thermostat, press “ ”+“” 10seconds, display “Set XX℃” (or XX), and
then press“” or“” to adjust the protection temperature, the temperature range :20~90℃(68~194℉), factory default
60℃(or 140℉).
Celsius and Fahrenheit selection
Under Off, Press “M” and “▼” 10seconds till display “C” or “F” to select the temperature display, when power on, it will
work under “C” or “F”.
Low temperature protection
When the low temperature protection is valid, thermostat turns off , when the room temperature (or the floor
temperature ) is lower than 5℃( 41℉), thermostat will be turned on automatically and display “ ”, and start heating
system. When the room temperature (or the floor temperature ) reaches 7℃(45℉), thermostat will close output.
Low temperature protection setting
Turn off the thermostat, press “M” and keep 3seconds,display “00” or “01”,press “” or “” to adjust the value. “00”
means invalid, “01” means valid. Factory default “00”.
Wiring Diagram
Installation
Note: Be sure to connect all the wires as per the wiring diagrams and keep it away from water, mud and other
material so as to prevent the unit being spoiled!
1. Open the front
cover with
screwdriver
2. Connect wire as
per wiring diagram
3. Fix the back panel with the
screw
4. hang up the front cover
on the two hooks with 30
degree angle and press
down to finish installation
S1
S2
floor sensor
HA323
N
L
N
electric heater
AC85~260V 50/60Hz
N L
H
Table of contents
Popular Thermostat manuals by other brands

Honeywell Home
Honeywell Home T6 Pro TH6320U2008 installation instructions

Friedrich
Friedrich WRT2 Installation and operation guide

Salus
Salus RT310i installation manual

White Rodgers
White Rodgers 1E30N-910 installation instructions

meitav-tec
meitav-tec ETN24-P-FC-SUPER2 Owner's manual installation and operating instructions

Johnson Controls
Johnson Controls TEC2103-2 installation instructions