OPERATION MANUAL
Applicable product model:
www.aegisfridge.com

1. Application Notes
2.Safety Instructions
3.Precautions in Use
4.Installation and Commissioning
4.1 Installation Environment
4.2 Installation Site
4.3 Preparation before Use
4.4 First Power-on
4.5 Operation after Power Failure
5.Product composition and overview
6.Operating Instructions
6.1 Function Introduction
6.2 Optional function
7.Maintenance and Service
7.1 Equipment Maintenance
7.2 Equipment Discontinuation
7.3 Maintenance, Replacement, and Recovery of Rechargeable Batteries
8.Troubleshooting and Maintenance Services
9.Specifications
10.Packing List
11.Electrical Schematic Diagram
1
2
4
4
4
4
5
5
6
7
10
10
19
19
20
19
21
Table of Contents
22
22
19
17
Thank you for choosing and using MELING BIOLOGY & MEDICAL products! For your safe and convenient
use and reasonable maintenance of the equipment, please read the Operation Instructions carefully before
use and keep it properly for reference
The equipment operator can copy some chapters of this operation manual, but only for internal use, for
example, to instruct the user how to deal with emergencies. These chapters are clearly marked in the catalog
of the manual.
MELING BIOLOGY & MEDICAL has no obligation and responsibility for any instrument damage caused by
the user's failure to use the equipment according to the instructions or the method specified by the
manufacturer.
Due to the rapid improvement of MELING BIOLOGY & MEDICAL products, the functions described
in the instructions may be inconsistent with those of the products you purchased. Please refer to the
physical functions.
®Please read carefully the Attention and Safety Precautions (in 2. Safety Instructions).
®During transportation or use, no violent vibration or collision is allowed and the
refrigerator shall be kept away from rain. Store in a clean room with humidity no more
than 80 %, no corrosive gas and good ventilation.
®Pharmacy/Medical refrigerators (hereinafter referred to as equipment) can only be
operated by trained and authorized personnel.
®Maintenance of the equipment can only be completed by MELING BIOLOGY &
MEDICAL or an agent authorized by MELING BIOLOGY & MEDICAL.
®If the operator encounters any situation not mentioned in this manual, please contact
MELING BIOLOGY & MEDICAL or the agent authorized by MELING BIOLOGY &
MEDICAL for the correct handling method.
®If the equipment is not used according to the method specified in the specification, it
may be damaged.
®Try to use the accessories provided by MELING BIOLOGY & MEDICAL. If users would
like to use other accessories, MELING BIOLOGY & MEDICAL will not be responsible
for the adverse consequences caused therefrom.
®Equipment must be inspected and maintained regularly to ensure good operation of the
equipment.
1. Application Notes
Tips
¿Properly use protective equipment (including protective clothing, protective gloves,
goggles, etc.)
¿Keep good hygiene habits
¿Please pay attention to safety when using this product
1

1. Application Notes
2. Safety Instructions
3. Precautions in Use
4. Installation and Commissioning
4.1 Installation Environment
4.2 Installation Site
4.3 Preparation before Use
4.4 First Power-on
4.5 Operation after Power Failure
5. Product composition and overview
6. Operating Instructions
6.1 Function Introduction
6.2 Optional function
7. Maintenance and Service
7.1 Equipment Maintenance
7.2 Equipment Discontinuation
7.3 Maintenance, Replacement, and Recovery of Rechargeable Batteries
8. Troubleshooting and Maintenance Services
9. Specifications
10.Packing List
11.Electrical Schematic Diagram
1
2
4
4
4
4
5
5
6
7
10
10
19
19
20
19
21
Table of Contents
22
22
19
17
refrigerator shall be kept away from rain. Store in a clean room with humidity no more
than 80 %, no corrosive gas and good ventilation.
® Pharmacy/Medical refrigerators (hereinafter referred to as equipment) can only be
operated by trained and authorized personnel.
® Maintenance of the equipment can only be completed by Glacier or an agent
authorized by Glacier.
® If the operator encounters any situation not mentioned in this manual, please contact
Glacier or the agent authorized by Glacier for the correct handling method.
® If the equipment is not used according to the method specified in the specification, it
may be damaged.
® Try to use the accessories provided by Glacier. If users would
like to use other accessories, Glacier will not be responsible for the adverse
consequences caused therefrom.
®Equipment must be inspected and maintained regularly to ensure good operation of the
equipment.
1. Application Notes
Thank you for choosing and using Glacier products! For your safe and convenient use and reasonable
maintenance of the equipment, please read the Operation Instructions carefully before use and keep it
properly for reference
The equipment operator can copy some chapters of this operation manual, but only for internal use, for
example, to instruct the user how to deal with emergencies. These chapters are clearly marked in the catalog
of the manual.
Glacier has no obligation and responsibility for any instrument damage caused by the user's failure to
use the equipment according to the instructions or the method specified by the manufacturer.
Due to the rapid improvement of Glacier products, the functions described in the instructions may be
inconsistent with those of the products you purchased. Please refer to the physical functions.
® Please read carefully the Attention and Safety Precautions (in 2. Safety Instructions).
® During transportation or use, no violent vibration or collision is allowed and the
Tips
¿Properly use protective equipment (including protective clothing, protective gloves,
goggles, etc.)
¿Keep good hygiene habits
¿Please pay attention to safety when using this product
1

2
3
When using this product for the first time, please pay attention to the meaning of the following warning signs
and carefully read the safety precautions, so that you can use this equipment safely and correctly.
W
arning: Failure to observe the precautions may result in serious personal injury
or death.
Do not touch the equipment with wet hands to avoid electric shock; Equipment shall not be grounded through
gas pipeline, water supply pipeline, telephone line or lightning rod, which may easily cause electric shock.
This equipment can only be installed by professional technicians or after-sales maintenance personnel, it
may cause electric shock or fire.
Be sure to install the equipment on a solid and flat ground and take due care to prevent tipping over
. If the
ground is not solid enough or the installation location is not appropriate, it may cause the equipment to fall
over and cause equipment damage or personal injury
.
Please handle the power cord carefully to avoid short circuits or open circuits. Please turn of
f the power
before pulling out the power plug. Hold the power plug carefully and pull it out. Do not pull the wires of the
power plug. Otherwise, it may cause electric shock or fire due to the short circuit.
Don't bundle the power cord, don't press it under furniture or heavy objects, and don't get close to heat
sources such as compressors.
Please insert the power plug into the outlet tightly to ensure firmness and reliability
, so as to avoid electric
leakage;
After installation, the power plug must be within reach, so that the power plug can be unplugged in
time in case of emergency
.
Separate special outlets must be used and grounded reliably
. The cross-sectional area of the copper
2
conductor in the wall connected with the outlet must be more than 4mm
. Do not lengthen the power cord
without authorization to avoid heating or fire.
Do not use the power supply that is not specified in the equipment design, so as to avoid overheating, short
circuit and other faults. For example, connecting 1
10 V rated voltage products to 220 V power supply may
cause faults such as overheating and equipment burning.
This equipment adopts a 220 V/50 HZ AC power
supply
. If the operating voltage is too low or too high, a suitable automatic voltage stabilizer must be installed
for cooperative use.
Please place the equipment stably and avoid shaking.
Do not place the equipment in a dangerous area, and do not operate the equipment near flammable items to
prevent explosion or fire accidents.
W
arning! Failure to observe the
precautions may result in serious personal
injury or death.
A
ttention! Failure to observe the precaution
s
m
ay result in personal injury or equipment
failure and related property losses.
Protective conductor terminal
Risk o
f Exploration This sign indicates the
risk o
f explosion when using volatile and
explosive chemicals.
Do not place it obliquely
A
void direct sunlight
Beware of electric shock.
Beware of fire
This equipment is a precision instrument
2.Safety Instructions
Do not place the equipment in areas exposed to the sun or rain, so as to prevent danger such as short circuit
or overheating.
Do not tilt or lay the equipment sideways, and do not impact the equipment body; Refrigeration systems are
installed in the equipment, which is easy to be damaged by tilt or impact.
Please place the equipment in a dry and dust-free environment to avoid risks such as overheating, and short circuit.
In case of unexpected sound, smell, smoke, etc. when the power is turned on, please unplug the power in
time and contact the manufacturer or supplier.
Please place the equipment in a dry and ventilated environment, and ensure that the equipment vents and
instrument surfaces are not blocked or shielded by walls or other objects; Do not use it in a poorly ventilated
environment to prevent damage caused by heat released by equipment.
It is forbidden to disassemble and modify this equipment without authorization, so as to avoid potential safety
hazards. In this case, MELING BIOLOGY & MEDICAL will not bear any responsibility for quality accidents.
It is forbidden to put inflammable and explosive dangerous goods, strong corrosive acids, alkalis and other
items unsuitable for the equipment in the equipment.
When storing toxic, harmful or radioactive materials, please use the equipment in safe areas. Improper use
may cause harm to human health or environment.
Metal objects such as nails or iron wires shall not be inserted into any aperture and gap or any outlet of the
equipment, otherwise electric shock or injury may be caused due to accidental contact between the above
objects and moving parts.
In order to ensure the normal operation and ventilation and heat dissipation of the equipment, the back, left
and right sides of the cabinet shall be at least 30cm away from the wall, and the air inlet and air outlet must
not be blocked by obstacles!
This equipment must be connected to a ground wire.
Note: Failure to observe the precautions may result in personal injury or equipment failure and
related property losses.
It is forbidden to store living animals, flowers or other items with strict temperature requirements in the
equipment.
When the equipment is running, do not touch the inner surface of the cabinet without wearing protective gear.
Hold the handle and close the door to avoid pinching your fingers; When the equipment is not used for a long
time, please unplug it and pack it for storage.
When restarting the equipment after power failure or power off, please check the equipment settings first,
otherwise the stored items may be damaged due to the change of settings.
The equipment can be used for item preservation, not as production equipment!
Keep the keys properly, so as to avoid accidents when children open the door accidentally.
When handling the equipment, please be careful not to tip over the equipment, so as to prevent equipment
damage or personal injury.
When handling, it shall be lifted from the bottom, with the inclined plane not be greater than 45°, and it shall
be handled with care. Please use the equipment in safe areas. Improper use may cause harm to human
health or environment.

2
3
When using this product for the first time, please pay attention to the meaning of the following warning signs
and carefully read the safety precautions, so that you can use this equipment safely and correctly.
Warning: Failure to observe the precautions may result in serious personal injury
or death.
Do not touch the equipment with wet hands to avoid electric shock; Equipment shall not be grounded through
gas pipeline, water supply pipeline, telephone line or lightning rod, which may easily cause electric shock.
This equipment can only be installed by professional technicians or after-sales maintenance personnel, it
may cause electric shock or fire.
Be sure to install the equipment on a solid and flat ground and take due care to prevent tipping over. If the
ground is not solid enough or the installation location is not appropriate, it may cause the equipment to fall
over and cause equipment damage or personal injury.
Please handle the power cord carefully to avoid short circuits or open circuits. Please turn off the power
before pulling out the power plug. Hold the power plug carefully and pull it out. Do not pull the wires of the
power plug. Otherwise, it may cause electric shock or fire due to the short circuit.
Don't bundle the power cord, don't press it under furniture or heavy objects, and don't get close to heat
sources such as compressors.
Please insert the power plug into the outlet tightly to ensure firmness and reliability, so as to avoid electric
leakage; After installation, the power plug must be within reach, so that the power plug can be unplugged in
time in case of emergency.
Separate special outlets must be used and grounded reliably. The cross-sectional area of the copper
2
conductor in the wall connected with the outlet must be more than 4mm . Do not lengthen the power cord
without authorization to avoid heating or fire.
Do not use the power supply that is not specified in the equipment design, so as to avoid overheating, short
circuit and other faults. For example, connecting 110 V rated voltage products to 220 V power supply may
cause faults such as overheating and equipment burning. This equipment adopts a 220 V/50 HZ AC power
supply. If the operating voltage is too low or too high, a suitable automatic voltage stabilizer must be installed
for cooperative use.
Please place the equipment stably and avoid shaking.
Do not place the equipment in a dangerous area, and do not operate the equipment near flammable items to
prevent explosion or fire accidents.
Warning! Failure to observe the
precautions may result in serious personal
injury or death.
Attention! Failure to observe the precautions
may result in personal injury or equipment
failure and related property losses.
Protective conductor terminal
Risk of Exploration This sign indicates the
risk of explosion when using volatile and
explosive chemicals.
Do not place it obliquely
Avoid direct sunlight
Beware of electric shock.
Beware of fire
This equipment is a precision instrument
2. Safety Instructions
Do not place the equipment in areas exposed to the sun or rain, so as to prevent danger such as short circuit
or overheating.
Do not tilt or lay the equipment sideways, and do not impact the equipment body; Refrigeration systems are
installed in the equipment, which is easy to be damaged by tilt or impact.
P
lease place the equipment in a dry and dust-free environment to avoid risks such as overheating, and short circuit.
In case of unexpected sound, smell, smoke, etc. when the power is turned on, please unplug the power in
time and contact the manufacturer or supplier
.
Please place the equipment in a dry and ventilated environment, and ensure that the equipment vents and
instrument surfaces are not blocked or shielded by walls or other objects; Do not use it in a poorly ventilated
environment to prevent damage caused by heat released by equipment.
It is forbidden to disassemble and modify this equipment without authorization, so as to avoid potential safety
hazards. In this case, Glacier will not bear any responsibility for quality accidents.
It is forbidden to put inflammable and explosive dangerous goods, strong corrosive acids, alkalis and other
items unsuitable for the equipment in the equipment.
When storing toxic, harmful or radioactive materials, please use the equipment in safe areas. Improper use
may cause harm to human health or environment.
Metal objects such as nails or iron wires shall not be inserted into any aperture and gap or any outlet of the
equipment, otherwise electric shock or injury may be caused due to accidental contact between the above
objects and moving parts.
In order to ensure the normal operation and ventilation and heat dissipation of the equipment, the back, left
and right sides of the cabinet shall be at least 30cm away from the wall, and the air inlet and air outlet must
not be blocked by obstacles!
This equipment must be connected to a ground wire.
Note:
Failure to observe the precautions may result in personal injury or equipment failure and
related property losses.
It is forbidden to store living animals, flowers or other items with strict temperature requirements in the
equipment.
When the equipment is running, do not touch the inner surface of the cabinet without wearing protective gear
.
Hold the handle and close the door to avoid pinching your fingers; When the equipment is not used for a long
time, please unplug it and pack it for storage.
When restarting the equipment after power failure or power of
f, please check the equipment settings first,
otherwise the stored items may be damaged due to the change of settings.
The equipment can be used for item preservation, not as production equipment!
Keep the keys properly
, so as to avoid accidents when children open the door accidentally.
When handling the equipment, please be careful not to tip over the equipment, so as to prevent equipment
damage or personal injury
.
When handling, it shall be lifted from the bottom, with the inclined plane not be greater than 45°, and it shall
be handled with care. Please use the equipment in safe areas. Improper use may cause harm to human
health or environment.

4
5
3. Precautions in Use
®Before putting the items into the equipment, please confirm that the temperature in the freezer storage chamber has
reached the set value first, and then put the articles in batches. Every time you put in items, they shall not exceed 1/3 of
the inner volume of the freezer storage chamber so as to prevent excessive temperature rise.
®The equipment temperature display value is the temperature at the temperature sensor in the freezer storage
chamber. There is a certain gap between the displayed temperature and the actual temperature at the center of the
equipment when the equipment just starts running, but as the equipment enters a stable state, the displayed temperature
will gradually approach the actual temperature.
®Please use a diluted neutral cleaner to clean the equipment, and do not use brushes, acid, gasoline, soap powder,
polishing agent or hot water to clean the equipment, otherwise the painted surface and plastic rubber parts may be
damaged. Be careful not to wipe plastic rubber parts with volatile solvents such as gasoline.
®When the equipment is not used for a long time, the power supply shall be cut off.
4.Product Installation
4.1 Installation Environment
òAmbient temperature: 16℃ ~ 32℃, the most ideal temperature is 18℃ ~ 25℃, and the air conditioning system
shall be used when necessary.
òRelative humidity: ≤80%RH.
òThere is no strong vibration and corrosive gas around.
òAvoid the existence of a large amount of dust.
òAvoid rocking or shaking the equipment.
òElevation of the working position of the equipment: less than 2000m.
òIndoor use, pollution degree 2, and overvoltage category II.
òInput voltage AC single-phase 220V~230V±10%, three-phase 342V~418V.
òThere is no direct sunlight, other cold and heat sources and strong electromagnetic interference, which will
affect the normal operation of the control system and directly damage the system in severe cases.
4.2 Installation Site
Figure: N and E ends
cannot be connected
Door handle
Mounting hole
Screw
1.Remove the outer packaging of all products (including the protective foam in the packaging box)
Warning: Don't put the plastic bags within the reach of children, so as to prevent suffocation accidents.
2.Inventory of accessories: Please check the accessories and materials according to the packing list.
3. Cleaning: Clean the product once before use.
4.Before use, remove the small wire shelf and put it at the bottom of the cabinet (applicable to YC-55L/YC-
55EL and YC-75L/YC-75EL).
5. Installation of door handles (YC-725L, YC-1015L/YC-1015EL, YC-1505L). In order to install handles,
the handles shall be placed together with accessories.
Handle installation method:
Firstly, open the door handle as shown in the following figure;
Then, remove the screw for installing the door handle on the cabinet, and install the handle seat with this screw;
Finally, install the handle cover, insert both ends of the handle cover into the corresponding grooves of
the handle seat, and then press it to close it.
4.3 Preparation before use
4.4 First Power-on
When using the equipment for the first time, please follow these steps:
1. After the equipment is placed, leveled and cleaned, it shall stand for more than 24 hours, and then power it on to
ensure the normal operation of the equipment.
2.Under no-load condition, connect the power cord to a special outlet with appropriate specifications.
3.After powering on, turn on the power switch of the equipment.
4.Check whether the operating temperature of the equipment reaches the required value, observe the normal start
and stop of the equipment for more than 24 hours, and put a small amount of items in the Refrigerator after
confirming the normal performance.
5.Please store items in batches, with the items not exceeding 1/3 of the cabinet volume each time. Ensure that the
equipment is running properly after shutdown for more than 12 hours before putting in the next batch of items).
6. Try not to open the door during cooling, otherwise the temperature will rise.
In order to operate the equipment normally and obtain the best performance level, the installation
site of the equipment shall meet the following requirements:
òIt cannot be installed in a narrow and closed space, and the door of the room shall not be
smaller or lower than this equipment, which shall at least ensure the normal access of the
equipment, so as to avoid the maintenance difficulties in case of equipment failure, which may
result in damage to stored items due to the failure to repair the equipment in time;
òThe installation floor must be solid, flat, non-combustible and able to bear the weight of the
equipment during operation;
òIt shall be with good ventilation, and direct sunlight shall be avoided;
òEach equipment needs to use a power outlet independently. Please ensure that the current
borne by the power outlet shall be ≥10A, and the plug and outlet are firmly connected;;
òCheck the working voltage before use. In areas with unstable voltage, consider using a
voltage stabilizer suitable for equipment load. The power of the voltage stabilizer is greater
than 4KW to ensure that the input voltage requirements in the installation environment are met.
òEquipment shall be reliably grounded. If the power cord outlet is equipped with grounding
wire, check whether the grounding is good before use. If the outlet is not equipped with
grounding wire, it must be installed by professional engineers and technicians.
Attention: Since the ambient temperature has great influence on the equipment, if the above
environmental requirements cannot be met, the equipment may not run normally. Please improve
the environment before using the equipment; The equipment is operated intermittently.

4
5
3. Precautions in Use
®Before putting the items into the equipment, please confirm that the temperature in the freezer storage chamber has
reached the set value first, and then put the articles in batches. Every time you put in items, they shall not exceed 1/3 of
the inner volume of the freezer storage chamber so as to prevent excessive temperature rise.
®The equipment temperature display value is the temperature at the temperature sensor in the freezer storage
chamber. There is a certain gap between the displayed temperature and the actual temperature at the center of the
equipment when the equipment just starts running, but as the equipment enters a stable state, the displayed temperature
will gradually approach the actual temperature.
®Please use a diluted neutral cleaner to clean the equipment, and do not use brushes, acid, gasoline, soap powder,
polishing agent or hot water to clean the equipment, otherwise the painted surface and plastic rubber parts may be
damaged. Be careful not to wipe plastic rubber parts with volatile solvents such as gasoline.
®When the equipment is not used for a long time, the power supply shall be cut off.
4. Product Installation
4.1 Installation Environment
òAmbient temperature: 16℃ ~ 32℃, the most ideal temperature is 18℃ ~ 25℃, and the air conditioning system
shall be used when necessary.
òRelative humidity: ≤80%RH.
òThere is no strong vibration and corrosive gas around.
òAvoid the existence of a large amount of dust.
òAvoid rocking or shaking the equipment.
òElevation of the working position of the equipment: less than 2000m.
òIndoor use, pollution degree 2, and overvoltage category II.
òInput voltage AC single-phase 220V~230V±10%, three-phase 342V~418V.
òThere is no direct sunlight, other cold and heat sources and strong electromagnetic interference, which will
affect the normal operation of the control system and directly damage the system in severe cases.
4.2 Installation Site
Figure: N and E ends
cannot be connected
Door handle
Mounting hole
Screw
1. Remove the outer packaging of all products (including the protective foam in the packaging box)
Warning: Don't put the plastic bags within the reach of children, so as to prevent suffocation accidents.
2. Inventory of accessories: Please check the accessories and materials according to the packing list.
3. Cleaning: Clean the product once before use.
4. Before use, remove the small wire shelf and put it at the bottom of the cabinet (applicable to GL-
RG-4M, GL-RG-12M, GL-RG-16M, GL-RG-23M).
5. Installation of door handles (GL-RG-4M, GL-RG-12M, GL-RG-16M, GL-RG-23M). In order to
install handles, the handles shall be placed together with accessories.
Handle installation method:
Firstly, open the door handle as shown in the following figure;
Then, remove the screw for installing the door handle on the cabinet, and install the handle seat with this screw;
Finally, install the handle cover, insert both ends of the handle cover into the corresponding grooves of
the handle seat, and then press it to close it.
4.3 Preparation before use
4.4 First Power-on
When using the equipment for the first time, please follow these steps:
1. After the equipment is placed, leveled and cleaned, it shall stand for more than 24 hours, and then power it on to
ensure the normal operation of the equipment.
2. Under no-load condition, connect the power cord to a special outlet with appropriate specifications.
3. After powering on, turn on the power switch of the equipment.
4. Check whether the operating temperature of the equipment reaches the required value, observe the normal start
and stop of the equipment for more than 24 hours, and put a small amount of items in the Refrigerator after
confirming the normal performance.
5. Please store items in batches, with the items not exceeding 1/3 of the cabinet volume each time. Ensure that the
equipment is running properly after shutdown for more than 12 hours before putting in the next batch of items).
6. Try not to open the door during cooling, otherwise the temperature will rise.
In order to operate the equipment normally and obtain the best performance level, the installation
site of the equipment shall meet the following requirements:
òIt cannot be installed in a narrow and closed space, and the door of the room shall not be
smaller or lower than this equipment, which shall at least ensure the normal access of the
equipment, so as to avoid the maintenance difficulties in case of equipment failure, which may
result in damage to stored items due to the failure to repair the equipment in time;
òThe installation floor must be solid, flat, non-combustible and able to bear the weight of the
equipment during operation;
òIt shall be with good ventilation, and direct sunlight shall be avoided;
òEach equipment needs to use a power outlet independently. Please ensure that the current
borne by the power outlet shall be ≥10A, and the plug and outlet are firmly connected;;
òCheck the working voltage before use. In areas with unstable voltage, consider using a
voltage stabilizer suitable for equipment load. The power of the voltage stabilizer is greater
than 4KW to ensure that the input voltage requirements in the installation environment are met.
òEquipment shall be reliably grounded. If the power cord outlet is equipped with grounding
wire, check whether the grounding is good before use. If the outlet is not equipped with
grounding wire, it must be installed by professional engineers and technicians.
Attention: Since the ambient temperature has great influence on the equipment, if the above
environmental requirements cannot be met, the equipment may not run normally. Please improve
the environment before using the equipment; The equipment is operated intermittently.

6
7
5. Product composition and overview
Figure I YC-55L (It can be used as reference for YC-55EL, YC-75L, YC-75EL)
®The transportation and movement of equipment is realized by casters.
®A special person shall be responsible for checking and recording the running status of the equipment every
day (record and check once every 2-4 hours). In case of failure or shutdown, the temperature in the
Refrigerator will rise. If it cannot be repaired in a short time, please take out the stored items and transfer
them to a place that meets the temperature requirements for storage to avoid damage to the items.
®Before putting items into the equipment, it shall be confirmed in advance whether the temperature range of
the equipment meets the temperature requirement of the items, so as to avoid damage to stored items due
to the difference between the settable temperature of the equipment and the required temperature of the
items. Please pay attention not to block the air outlet and air inlet when putting items into the equipment.
®Due to the refrigeration inertia, there is a certain difference between the actual display temperature and the
set temperature of the equipment, which is a normal phenomenon.
®The equipment is an item storage equipment, which cannot be used for routine production operations. It is
strictly forbidden to put too many items which are relatively hot into the equipment at one time, otherwise
the compressor will run for a long time, and be burned due to high temperature. Items must be put in
batches, so as to ensure that the Refrigerator is cooled step by step until the temperature required for
storing items is reached.
®Electrical appliances without production license shall not be used inside the equipment.
®Do not change the set temperature frequently in a short time, otherwise the expected setting effect may not
be achieved due to the large temperature inertia; Ensure that there is a certain air circulation space around
the cabinet when putting in items, especially do not block the temperature sensor in the cabinet (for
collecting the temperature of the cabinet), otherwise it will affect the stability and accurate control of the
temperature in the cabinet!
®Items shall not be placed directly at the bottom of the Refrigerator, but on the bottom shelf, otherwise the
refrigeration effect of the equipment will be affected.
®When putting in items, if the moisture content of the items is too much or too little, it will affect the humidity
change in the cabinet, so it is best to keep the items sealed; The humidity of the working environment will
affect the change of humidity in the cabinet, especially if the door is opened too frequently and the door is
not closed properly.
Notes:
Warning: Children are not allowed to play with this equipment as a game prop, otherwise the injury
or loss caused therefrom will be at their own risk.
Figure II YC-130L
4.5 Operation after Power Failure
1. The equipment has a memory function for the set value. When the power is restored after power failure, the equipment
will continue to operate before power failure.
2. Once the equipment is powered off, it requires 5 minutes before it can be switched on again, so as to avoid damaging the
compressor.
3. We guarantee the normal operation of this equipment under certain conditions, but we are not responsible for any loss or
damage of stored items after power failure.
USB interface
Door body
Display panel
Door lock
Test hole
Cabinet
Caster
Adjust feet
Power switch
Remote alarm
interface
Rs485 interface
Door lock
Test hole
Door handle
Cabinet
Adjust feet
Caster
Door body
USB interface
Display panel

6
7
5. Product composition and overview
Figure I GL-RG-4M
®The transportation and movement of equipment is realized by casters.
®A special person shall be responsible for checking and recording the running status of the equipment every
day (record and check once every 2-4 hours). In case of failure or shutdown, the temperature in the
Refrigerator will rise. If it cannot be repaired in a short time, please take out the stored items and transfer
them to a place that meets the temperature requirements for storage to avoid damage to the items.
®Before putting items into the equipment, it shall be confirmed in advance whether the temperature range of
the equipment meets the temperature requirement of the items, so as to avoid damage to stored items due
to the difference between the settable temperature of the equipment and the required temperature of the
items. Please pay attention not to block the air outlet and air inlet when putting items into the equipment.
®Due to the refrigeration inertia, there is a certain difference between the actual display temperature and the
set temperature of the equipment, which is a normal phenomenon.
®The equipment is an item storage equipment, which cannot be used for routine production operations. It is
strictly forbidden to put too many items which are relatively hot into the equipment at one time, otherwise
the compressor will run for a long time, and be burned due to high temperature. Items must be put in
batches, so as to ensure that the Refrigerator is cooled step by step until the temperature required for
storing items is reached.
®Electrical appliances without production license shall not be used inside the equipment.
®Do not change the set temperature frequently in a short time, otherwise the expected setting effect may not
be achieved due to the large temperature inertia; Ensure that there is a certain air circulation space around
the cabinet when putting in items, especially do not block the temperature sensor in the cabinet (for
collecting the temperature of the cabinet), otherwise it will affect the stability and accurate control of the
temperature in the cabinet!
®Items shall not be placed directly at the bottom of the Refrigerator, but on the bottom shelf, otherwise the
refrigeration effect of the equipment will be affected.
®When putting in items, if the moisture content of the items is too much or too little, it will affect the humidity
change in the cabinet, so it is best to keep the items sealed; The humidity of the working environment will
affect the change of humidity in the cabinet, especially if the door is opened too frequently and the door is
not closed properly.
Notes:
Warning: Children are not allowed to play with this equipment as a game prop, otherwise the injury
or loss caused therefrom will be at their own risk.
Figure II GL-RG-4M
4.5 Operation after Power Failure
1. The equipment has a memory function for the set value. When the power is restored after power failure, the equipment
will continue to operate before power failure.
2. Once the equipment is powered off, it requires 5 minutes before it can be switched on again, so as to avoid damaging the
compressor.
3. We guarantee the normal operation of this equipment under certain conditions, but we are not responsible for any loss or
damage of stored items after power failure.
USB interface
Door body
Display panel
Door lock
Test hole
Cabinet
Caster
Adjust feet
Power switch
Remote alarm
interface
Rs485 interface
Door lock
Test hole
Door handle
Cabinet
Adjust feet
Caster
Door body
USB interface
Display panel

8
9
Figure III
Figure IV
* Due to the improvement of products and model differences, the actual products may be different from the diagram.
Please refer to the actual products! The diagram is only used for functional parts description.
*Structure and composition: The product consists of cabinet, door (glass door structure or foam door structure),
refrigeration system and control system.
*Scope of application: It is suitable for storing items in hospitals, pharmacies, epidemic prevention stations, research
institutions, biopharmaceuticals and other units.
Figure V YC-1505L (It can be used as reference for YC-1015L and YC1015EL)
Caster
Door handle
Door body
Cabinet
Caster
Door lock
Steel wire shelf
Door body
Adjust feet
Caster
Cabinet
Test hole
Steel wire shelf
Test hole
Printer (optional) Display panel
(power switch
on the back)
USB interface
Printer (optional)
Display panel
(power switch
on the back)
USB interface
Door lock
Door handle

8
9
Figure III YC-395L(It can be used as reference for YC-315L, YC-395EL, YC-400L and YC-525L)
Figure IV YC-725L (It can be used as reference for YC-1015L and YC-1015EL)
* Due to the improvement of products and model differences, the actual products may be different from the diagram.
Please refer to the actual products! The diagram is only used for functional parts description.
*Structure and composition: The product consists of cabinet, door (glass door structure or foam door structure),
refrigeration system and control system.
*Scope of application: It is suitable for storing items in hospitals, pharmacies, epidemic prevention stations, research
institutions, biopharmaceuticals and other units.
Figure V
Caster
Door handle
Door body
Cabinet
Caster
Door lock
Steel wire shelf
Door body
Adjust feet
Caster
Cabinet
Test hole
Steel wire shelf
Test hole
Printer (optional) Display panel
(power switch
on the back)
USB interface
Printer (optional)
Display panel
(power switch
on the back)
USB interface
Door lock
Door handle

This series of products include two control systems, based on which different adjustment methods apply. Please select the
proper adjustment method according to the type of control system with the storage box you purchased.
6. Operating Instructions
a. Door switch indicator
When the door is opened, the door switch indicator is on; When the door is closed, the door switch indicator is off.
b.Defrosting indicator
When the refrigerator enters the defrosting state, the defrosting indicator is always on; When the refrigerator exits the
defrosting state, the defrosting indicator is always off.
c. Key lock indicator
When the keys are in lock state, none of the keys respond, and the key lock lights up. In this case, after pressing the
up key+down key for 3s, you will be prompted to enter the password, which is defaulted as "005." After entering it
correctly, press the Set/Mute Multiplex key, and the key lock will be released. At this time, the key lock indicator will
be off. In the unlock state, if no key is pressed for 60s, the key lock is started, and the key lock indicator is on. Long
press the up key + down key for 3s, and the keys are locked.
d.Power-off indicator
The refrigerator is normally powered by 220V. When the input power is turned off, the buzzer will be triggered, the
digital tube flashes the power-off code "PF" alternately at 3s intervals, and the power-off indicator is on. When the input
power is turned on, it returns to normal, and the power-off indicator is off.
e.Print indicator
When the printer is not working, the indicator is off; When the printer is working, the indicator is on.
f.Door heating indicator
When the door heating is turned off, the door heating indicator is off; When the door heating is turned on, the door
heating indicator is on.
g.Refrigeration indicator
If the compressor is in working condition, the refrigeration indicator is on; If the compressor is in a shutdown state,
the cooling indicator is off.
h.Mute indicator
When the alarm tone key is muted, the indicator is on; When the alarm mute function is canceled, the indicator is
off.
i.Low battery level indicator
When the battery voltage is less than 8V, the buzzer will be triggered, the low battery indicator will be on, and the
digital tube will flash the low battery code "BL" alternately at intervals of 3s; When the battery voltage is greater than
12V, the buzzer will be turned off, the low battery indicator will be off, and the digital tube will resume normal display.
j.Serial port indicator
When the reserved RS-485 serial port is not connected to the equipment, the serial port indicator will be off; When
the equipment is successfully connected to the reserved RS-485 serial port, the serial port indicator will be on.
k.Fan indicator
When the evaporator fan is turned on, the fan indicator is on; when the evaporator fan is turned off, the fan indicator
is off.
1) Description of display icon indicator
(as shown in the right diagram)
2) temperature display window, which displays the average temperature inside the cabinet in °C under
normal operation;
View ambient temperature:
In the key lock state, press key, and digital tube displays the ambient temperature, and returns to normal
display after 5 s without key operation, or pressing and . In the key unlock state, press key, and digital
tube displays ambient temperature, and returns to normal display after 5s without key operation.
Humidity check: key unlocked state, long press and , digital tube display humidity, no press any Key
operation after 5 seconds or press and , return to normal display.
3) is the set/mute key; In case of no alarm state and key unlock state, press , and display the ambient
temperature for 5s and then return to normal display; In the unlock state, press for more than 3s, and enter the
user menu.
When buzzer is triggered (including cabinet high temperature alarm, door opening alarm, sensor failure alarm, etc.)
and in the key unlock state, press for the first time, and the buzzer stops ringing, and the ambient temperature
is displayed for 5s, after which the normal display is resumed (pressing the mute button is only to turn off the buzzer
for alarming this abnormal state, for example troubleshooting, and the buzzer will be triggered next time for any
abnormality). Then press again, trigger the buzzer, display the ambient temperature for 5s, and resume the
display of chamber temperature and alarm state. In the key unlock state, can be used as a setting key.
In unlock state and parameter setting mode, press this key to display parameter values and parameter names. If the
pressing time is longer than 3 seconds, save the settings and return to the normal interface.
4) is a up key; In parameter setting mode, move to the next parameter or increase the parameter value. For
example, when setting the set temperature, increase the set temperature value. When setting the parameter value,
long press the up button, and the parameter will increase rapidly. Under normal conditions, long press the up key for
3 seconds to import the data of the USB flash drive in 12 months.
5) is a down key;
In parameter setting mode, move to the previous parameter or decrease the parameter value.
For example, when setting the set temperature, reduce the set temperature.
When setting the parameter value, long press the down button, and the parameter will decrease rapidly.
6) is a print key;
The system can keep 7 days of data for printing, and press the print key to print the temperature within the set time
period.
7) is a light switch key;
When the equipment is powered on, the lights are turned off by default. Press the light switch key to turn the lights
on and off. When the light is off, it can be turned on when the door is opened and turned off when the door is
closed; When the light is off, it does not change when the door is opened or closed. This equipment has two
functions: automatic lighting and manual lighting. In the automatic lighting state, the lighting lamp will be on
immediately when the door is opened, and the lighting lamp will be off after a 5 seconds delay; The user can also
turn on the lighting lamp manually. In this case, the lighting lamp is always on (the indicator light above the key is
on) without being controlled by the door opening and closing. Only when the manual lighting is turned off by
pressing the light switch key again can the lighting lamp be automatically on (the indicator light above the key is off).
8) USB data export;
Automatic export: When the USB interface is connected to the USB flash drive, the buzzer of the recorder beeps
once, displaying "on," and PDF files of the data of the current month and the previous month are generated in the
USB flash drive. After the data transmission is completed, the buzzer beeps once, displaying "End," and the normal
display resumes after 6s.
Note: When there is less data, the digital tube will not display "on" and "End."。
Manual export: In the key unlock state, and when the USB flash drive is connected and the file is not being
generated, press the key up for 3 seconds, and the digital tube will display "d01." Press the up key or down key to
adjust "d00~d12," and press key to obtain the file generation (d00) or generate the PDF file of the record data
of the previous months (1-12).
1. Function description of Type A control panel (Applicable to YC-55L, YC-55EL, YC-75L, YC-75EL, YC-315L, YC-395L,
YC-395EL, YC-400L, YC-525L, YC-725L, YC-1015L, YC-1015EL, YC-1505L)
10
11
6.1 Function Introduction
Type A control panel
Printer (optional)
Door
switch
Power
failure
Mute
WIFI
Print
Electric
quantity
Defrosting
Door
heating
Serial
port
Key lock
Refrigeration
Fan

This series of products include two control systems, based on which different adjustment methods apply. Please select the
proper adjustment method according to the type of control system with the storage box you purchased.
6. Operating Instructions
a. Door switch indicator
When the door is opened, the door switch indicator is on; When the door is closed, the door switch indicator is off.
b.Defrosting indicator
When the refrigerator enters the defrosting state, the defrosting indicator is always on; When the refrigerator exits the
defrosting state, the defrosting indicator is always off.
c. Key lock indicator
When the keys are in lock state, none of the keys respond, and the key lock lights up. In this case, after pressing the
up key+down key for 3s, you will be prompted to enter the password, which is defaulted as "005." After entering it
correctly, press the Set/Mute Multiplex key, and the key lock will be released. At this time, the key lock indicator will
be off. In the unlock state, if no key is pressed for 60s, the key lock is started, and the key lock indicator is on. Long
press the up key + down key for 3s, and the keys are locked.
d.Power-off indicator
The refrigerator is normally powered by 220V. When the input power is turned off, the buzzer will be triggered, the
digital tube flashes the power-off code "PF" alternately at 3s intervals, and the power-off indicator is on. When the input
power is turned on, it returns to normal, and the power-off indicator is off.
e.Print indicator
When the printer is not working, the indicator is off; When the printer is working, the indicator is on.
f.Door heating indicator
When the door heating is turned off, the door heating indicator is off; When the door heating is turned on, the door
heating indicator is on.
g.Refrigeration indicator
If the compressor is in working condition, the refrigeration indicator is on; If the compressor is in a shutdown state,
the cooling indicator is off.
h.Mute indicator
When the alarm tone key is muted, the indicator is on; When the alarm mute function is canceled, the indicator is
off.
i.Low battery level indicator
When the battery voltage is less than 8V, the buzzer will be triggered, the low battery indicator will be on, and the
digital tube will flash the low battery code "BL" alternately at intervals of 3s; When the battery voltage is greater than
12V, the buzzer will be turned off, the low battery indicator will be off, and the digital tube will resume normal display.
j.Serial port indicator
When the reserved RS-485 serial port is not connected to the equipment, the serial port indicator will be off; When
the equipment is successfully connected to the reserved RS-485 serial port, the serial port indicator will be on.
k.Fan indicator
When the evaporator fan is turned on, the fan indicator is on; when the evaporator fan is turned off, the fan indicator
is off.
1) Description of display icon indicator
(as shown in the right diagram)
2)temperature display window, which displays the average temperature inside the cabinet in °C under
normal operation;
View ambient temperature:
In the key lock state, press key, and digital tube displays the ambient temperature, and returns to normal
display after 5 s without key operation, or pressing and . In the key unlock state, press key, and digital
tube displays ambient temperature, and returns to normal display after 5s without key operation.
Humidity check: key unlocked state, long press and , digital tube display humidity, no press any Key
operation after 5 seconds or press and , return to normal display.
3)is the set/mute key; In case of no alarm state and key unlock state, press , and display the ambient
temperature for 5s and then return to normal display; In the unlock state, press for more than 3s, and enter the
user menu.
When buzzer is triggered (including cabinet high temperature alarm, door opening alarm, sensor failure alarm, etc.)
and in the key unlock state, press for the first time, and the buzzer stops ringing, and the ambient temperature
is displayed for 5s, after which the normal display is resumed (pressing the mute button is only to turn off the buzzer
for alarming this abnormal state, for example troubleshooting, and the buzzer will be triggered next time for any
abnormality). Then press again, trigger the buzzer, display the ambient temperature for 5s, and resume the
display of chamber temperature and alarm state. In the key unlock state, can be used as a setting key.
In unlock state and parameter setting mode, press this key to display parameter values and parameter names. If the
pressing time is longer than 3 seconds, save the settings and return to the normal interface.
4)is a up key; In parameter setting mode, move to the next parameter or increase the parameter value. For
example, when setting the set temperature, increase the set temperature value. When setting the parameter value,
long press the up button, and the parameter will increase rapidly. Under normal conditions, long press the up key for
3 seconds to import the data of the USB flash drive in 12 months.
5)is a down key;
In parameter setting mode, move to the previous parameter or decrease the parameter value.
For example, when setting the set temperature, reduce the set temperature.
When setting the parameter value, long press the down button, and the parameter will decrease rapidly.
6)is a print key;
The system can keep 7 days of data for printing, and press the print key to print the temperature within the set time
period.
7)is a light switch key;
When the equipment is powered on, the lights are turned off by default. Press the light switch key to turn the lights
on and off. When the light is off, it can be turned on when the door is opened and turned off when the door is
closed; When the light is off, it does not change when the door is opened or closed. This equipment has two
functions: automatic lighting and manual lighting. In the automatic lighting state, the lighting lamp will be on
immediately when the door is opened, and the lighting lamp will be off after a 5 seconds delay; The user can also
turn on the lighting lamp manually. In this case, the lighting lamp is always on (the indicator light above the key is
on) without being controlled by the door opening and closing. Only when the manual lighting is turned off by
pressing the light switch key again can the lighting lamp be automatically on (the indicator light above the key is off).
8)USB data export;
Automatic export: When the USB interface is connected to the USB flash drive, the buzzer of the recorder beeps
once, displaying "on," and PDF files of the data of the current month and the previous month are generated in the
USB flash drive. After the data transmission is completed, the buzzer beeps once, displaying "End," and the normal
display resumes after 6s.
Note: When there is less data, the digital tube will not display "on" and "End."。
Manual export: In the key unlock state, and when the USB flash drive is connected and the file is not being
generated, press the key up for 3 seconds, and the digital tube will display "d01." Press the up key or down key to
adjust "d00~d12," and press key to obtain the file generation (d00) or generate the PDF file of the record data
of the previous months (1-12).
1. Function description of Type A control panel (Applicable to YC-55L, YC-55EL, YC-75L, YC-75EL, YC-315L, YC-395L,
YC-395EL, YC-400L, YC-525L, YC-725L, YC-1015L, YC-1015EL, YC-1505L)
10
11
6.1 Function Introduction
Type A control panel
Printer (optional)
Door
switch
Power
failure
Mute
WIFI
Print
Electric
quantity
Defrosting
Door
heating
Serial
port
Key lock
Refrigeration
Fan

2. Function setting of Type A control panel
1. After powering on, the equipment can enter the working state;
2. User parameter settings:
To unlock: under normal operating conditions, and long press for 3 seconds, the digital display code
"000", input password "005" to unlock (enter "099" can restore the default user password to "005" again if user forge
t the password). After unlock, hold for 3 seconds, it will enter user menu.If the controller displays "PS1",
it means enter user menu successfully.
Use or key to scroll the parameters, and the display order is as follows:
Ps1→b1→b2→Set→H→L→n→y→r→S→F→Pt→tH1→P1→P2. Press to confirm the parameter type, and the
first parameter name of this type of parameter will be displayed;
①Use or key to scroll the parameters;
②Press key to display the corresponding parameter value;
③Use or key to scroll the parameters;
④Use to temporarily store the modified values and return to the display parameters;
⑤If other parameters are modified, repeat steps ① to ④;
⑥Press for more than 3s, save the modified parameters and return to the display parameter category.
3. Press for more than 3s, or press no key in 60s to exit the parameter setting program.
4. Parameter display
No. Menu item Parameter Range Suggested settings Remarks
1 Set 0.0-10.0 5.0 Temperature setting
2 H 0.0-10.0 5.0
Set value of high temperature alarm set+H; When H =0,
High temp alarm is disabled; When the alarm is over hig
h
temp alarm set, H1 will be displayed on the controller
3 L 0.0-10.0 4.0
Set value of low temperature alarm set-L; When L =0,
Low temp alarm is disabled; When the alarm is below
low temp alarm set, L1 will be displayed on the
controller
4 Pt 0-240 min 20 Print interval
5 tH1 20.0-50.0℃50 Upper limit of ambient temperature alarm
6 P1
1. Automatic heating
mode 1
2. Automatic heating
mode 2
3. Automatic heating
mode 31
4. Always on
5. Always off
1.(Set to 4 when
the door is with
condensation)
(Set to 1 when the
door is a glass
door)
(Set to 5 when the
door is a foaming
door)
Mode 1: It shall be judged as once after the door is
opened and closed once and heated for 5min (time
setting). If the door is opened and closed again during
the heating period, the heating time will be updated
again;
Mode 2: When the compressor runs, Heater is on;
When the compressor stops, the heater Will
automatically off after one min
Mode 3: When the humidity in the cabinet is more than
80%, the door heating is on, and when the humidity in
the cabinet is moderately less than 60%, the door
heating is off;
Mode 4: Door heating is always on;
Mode 5: Door heating is always off.
7 P2
1. Average
temperature
2. Upper temperature
3.Lower temperature
1 Display mode selection (optional function)
8 005 User menu password settings
12
13
PS1
Alarm Code
Error Description
H1
High temperature alarm
L1
Low temperature alarm
H2
Alarm for high ambient temperature
H3
Condenser overheat alarm
do
Door opening alarm
PF
Power failure alarm
bL
Battery low alarm
Er
The recorder is not connected
LoF
Battery low alarm
EE
Communication failure
5. Alarm display

2. Function setting of Type A control panel
1. After powering on, the equipment can enter the working state;
2. User parameter settings:
To unlock: under normal operating conditions, and long press for 3 seconds, the digital display code
"000", input password "005" to unlock (enter "099" can restore the default user password to "005" again if user forge
t the password). After unlock,hold for 3 seconds, it will enter user menu.If the controller displays "PS1",
it means enter user menu successfully.
Use or key to scroll the parameters, and the display order is as follows:
Ps1→b1→b2→Set→H→L→n→y→r→S→F→Pt→tH1→P1→P2. Press to confirm the parameter type, and the
first parameter name of this type of parameter will be displayed;
① Use or key to scroll the parameters;
② Press key to display the corresponding parameter value;
③ Use or key to scroll the parameters;
④ Use to temporarily store the modified values and return to the display parameters;
⑤ If other parameters are modified, repeat steps ① to ④;
⑥ Press for more than 3s, save the modified parameters and return to the display parameter category.
3. Press for more than 3s, or press no key in 60s to exit the parameter setting program.
4. Parameter display
No.
Menu item
Parameter Range
Suggested settings
Remarks
1
Set
0.0-10.0
5.0
Temperature setting
2
H
0.0-10.0
5.0
Set value of high temperature alarm set+H; When H =0,
High temp alarm is disabled; When the alarm is over high
temp alarm set, H1 will be displayed on the controller
3
L
0.0-10.0
4.0
Set value of low temperature alarm set-L; When L =0,
Low temp alarm is disabled; When the alarm is below
low temp alarm set, L1 will be displayed on the
controller
4
Pt
0-240 min
20
Print interval
5
tH1
20.0-50.0℃
50
Upper limit of ambient temperature alarm
6
P1
1. Automatic heating
mode 1
2. Automatic heating
mode 2
3. Automatic heating
mode 31
4. Always on
5. Always off
1.(Set to 4 when
the door is with
condensation)
(Set to 1 when the
door is a glass
door)
(Set to 5 when the
door is a foaming
door)
Mode 1: It shall be judged as once after the door is
opened and closed once and heated for 5min (time
setting). If the door is opened and closed again during
the heating period, the heating time will be updated
again;
Mode 2: When the compressor runs, Heater is on;
When the compressor stops, the heater Will
automatically off after one min
Mode 3: When the humidity in the cabinet is more than
80%, the door heating is on, and when the humidity in
the cabinet is moderately less than 60%, the door
heating is off;
Mode 4: Door heating is always on;
Mode 5: Door heating is always off.
7
P2
1. Average
temperature
2. Upper temperature
3.Lower temperature
1
Display mode selection (optional function)
8
005
User menu password settings
12
13
PS1
Alarm Code Error Description
H1 High temperature alarm
L1 Low temperature alarm
H2 Alarm for high ambient temperature
H3 Condenser overheat alarm
do Door opening alarm
PF Power failure alarm
bL Battery low alarm
Er The recorder is not connected
LoF Battery low alarm
EE Communication failure
5. Alarm display

1. Function description of Type B control panel (Applicable to YC-130L)
a. It is temperature display window, which displays the average temperature inside the cabinet in °C under
normal operation; Different prompt characters can be displayed in the setting state (see below for details);
b.Door opening indicator: When the refrigerator door is opened, the indicator lights up. After more than 1 minute,
the door opening alarm indicator will be on and the buzzer triggered, displaying "do".
c.Fault indicator: When the product runs normally, the indicator is off; The indicator is on for operation abnormality.
d.“LIGHT” : After the machine is powered on, the light is off by default, and the on-off of the light can be adjusted by
the on-off key. When the light is off, it can be turned on when the door is opened and turned off when the door is
closed; When the light is off, it does not change when the door is opened or closed. This equipment has two
functions: automatic lighting and manual lighting. In the automatic lighting state, the lighting lamp will be on
immediately when the door is opened, and the lighting lamp will be off after a 5 seconds delay; The user can also
turn on the lighting lamp manually. In this case, the lighting lamp is always on (the indicator light above the key is
on) without being controlled by the door opening and closing. Only when the manual lighting is turned off by
pressing the light switch key again can the lighting lamp be automatically on (the indicator light above the key is off).
e. “PRINT “ (optional): The system can keep 7 days of data for printing. Press the print key to print the temperature
within the set time period.
f.: In parameter setting mode, reduce the parameter value. For example, when setting the set temperature,
reduce the set temperature. When setting the parameter value, long press the down button, and the parameter will
decrease rapidly.
g. : In parameter setting mode, increase the parameter value. For example, when setting the set temperature,
increase the set temperature value. When setting the parameter value, long press the up button, and the parameter
will increase rapidly. Under normal conditions, long press the up key for 3 seconds to import the data of the USB
flash drive in 12 months.
h. is the set/mute key; In case of no alarm state and key unlock state, press , and display the ambient
temperature for 5s and then return to normal display; In the unlock state, press for more than 3s, and enter the
user menu.
When buzzer is triggered (including cabinet high alarm, door opening alarm, sensor failure alarm, etc.) and in the
button unlock state, press for the first time, and the buzzer stops ringing, and the ambient temperature is
displayed for 5s, after which the normal display is resumed (pressing the mute button is only to turn off the buzzer
for alarming this abnormal state, for example trouble removal, and the buzzer will be triggered next time for any
abnormality). Then press again, trigger the buzzer, display the ambient temperature for 5s, and then resume the
display of cabinet temperature and alarm state. In the key unlock state, can be used as a setting key.
In unlock state and parameter setting mode, press this key to display parameter values and parameter
names. If the pressing time is longer than 3 seconds, save the settings and return to the normal interface.
I. USB interface
Automatic export of USB data: When the USB interface is connected to the USB flash drive, the buzzer of
the recorder beeps once, displaying "ON", and PDF files of the data of the current month and the previous
month are generated in the USB flash drive. After the data transmission is completed, the buzzer beeps
once, displaying "End," and the normal display resumes after 6s.
Note: When there is less data, "on" and "end" prompts are not displayed.
Manual export of USB data: In the key unlock state, when the USB flash drive is connected and the file is not being
generated, press the up key for 3 seconds, and the digital tube in the lower chamber will display "d01." Press the
key up or down key to adjust "d00~d12," and press key to cancel the file generation (d00) or generate the PDF
file of the record data of the previous months (1-12).
Note: When the alarm of the digital tube flashes and displays "LoF," the recorder is not started;
Meanwhile press and key for 3s,and "LoF" disappears, the recorder is started.
2. Function setting of Type B control panel
1) Power on and turn on the power switch on the back of the cabinet, and the equipment will enter the working
state;
2) User parameter settings:
Unlock: In normal operation state, simultaneously press and key for 3s, and the digital tube displays the
parameter code "000”, enter the password "0005” ( (when you enter the user menu password, enter "0099" to restore
the key lock password to the default value of "0005"). , and unlock it. Unlock and press key for 3s, and the digital
tube will display the parameter code "PS1," and enter the setting and adjustment parameters.
Use or key to scroll the parameters, and the display order is as follows: b1→b2→Set→H→L→n→
y→r→S→F→Pt→tH1→P1→Ps1.
Press to confirm the parameter type, and the first parameter name of this type of parameter will be displayed;
①Use or key to scroll the parameters;
②Press key to display the corresponding parameter value;
③Use or to increase or decrease the value ⑥; Press for more than 3s, save the modified
parameters and return to the display parameter category.
④Use to temporarily store the modified values and return to the display parameters;
⑤If other parameters are modified, repeat steps ① to ④.
Type B control panel
ac
b
e
f
g
h
i d
14
15
(optional) (optional)

1. Function description of Type B control panel (Applicable to YC-130L)
a. It is temperature display window, which displays the average temperature inside the cabinet in °C under
normal operation; Different prompt characters can be displayed in the setting state (see below for details);
b.Door opening indicator: When the refrigerator door is opened, the indicator lights up. After more than 1 minute,
the door opening alarm indicator will be on and the buzzer triggered, displaying "do".
c.Fault indicator: When the product runs normally, the indicator is off; The indicator is on for operation abnormality.
d.“LIGHT” : After the machine is powered on, the light is off by default, and the on-off of the light can be adjusted by
the on-off key. When the light is off, it can be turned on when the door is opened and turned off when the door is
closed; When the light is off, it does not change when the door is opened or closed. This equipment has two
functions: automatic lighting and manual lighting. In the automatic lighting state, the lighting lamp will be on
immediately when the door is opened, and the lighting lamp will be off after a 5 seconds delay; The user can also
turn on the lighting lamp manually. In this case, the lighting lamp is always on (the indicator light above the key is
on) without being controlled by the door opening and closing. Only when the manual lighting is turned off by
pressing the light switch key again can the lighting lamp be automatically on (the indicator light above the key is off).
e. “PRINT “ (optional): The system can keep 7 days of data for printing. Press the print key to print the temperature
within the set time period.
f.: In parameter setting mode, reduce the parameter value. For example, when setting the set temperature,
reduce the set temperature. When setting the parameter value, long press the down button, and the parameter will
decrease rapidly.
g. : In parameter setting mode, increase the parameter value. For example, when setting the set temperature,
increase the set temperature value. When setting the parameter value, long press the up button, and the parameter
will increase rapidly. Under normal conditions, long press the up key for 3 seconds to import the data of the USB
flash drive in 12 months.
h. is the set/mute key; In case of no alarm state and key unlock state, press , and display the ambient
temperature for 5s and then return to normal display; In the unlock state, press for more than 3s, and enter the
user menu.
When buzzer is triggered (including cabinet high alarm, door opening alarm, sensor failure alarm, etc.) and in the
button unlock state, press for the first time, and the buzzer stops ringing, and the ambient temperature is
displayed for 5s, after which the normal display is resumed (pressing the mute button is only to turn off the buzzer
for alarming this abnormal state, for example trouble removal, and the buzzer will be triggered next time for any
abnormality). Then press again, trigger the buzzer, display the ambient temperature for 5s, and then resume the
display of cabinet temperature and alarm state. In the key unlock state, can be used as a setting key.
In unlock state and parameter setting mode, press this key to display parameter values and parameter
names. If the pressing time is longer than 3 seconds, save the settings and return to the normal interface.
I. USB interface
Automatic export of USB data: When the USB interface is connected to the USB flash drive, the buzzer of
the recorder beeps once, displaying "ON", and PDF files of the data of the current month and the previous
month are generated in the USB flash drive. After the data transmission is completed, the buzzer beeps
once, displaying "End," and the normal display resumes after 6s.
Note: When there is less data, "on" and "end" prompts are not displayed.
Manual export of USB data: In the key unlock state, when the USB flash drive is connected and the file is not being
generated, press the up key for 3 seconds, and the digital tube in the lower chamber will display "d01." Press the
key up or down key to adjust "d00~d12," and press key to cancel the file generation (d00) or generate the PDF
file of the record data of the previous months (1-12).
Note: When the alarm of the digital tube flashes and displays "LoF," the recorder is not started;
Meanwhile press and key for 3s,and "LoF" disappears, the recorder is started.
2. Function setting of Type B control panel
1) Power on and turn on the power switch on the back of the cabinet, and the equipment will enter the working
state;
2) User parameter settings:
Unlock: In normal operation state, simultaneously press and key for 3s, and the digital tube displays the
parameter code "000”, enter the password "0005” ( (when you enter the user menu password, enter "0099" to restore
the key lock password to the default value of "0005"). , and unlock it. Unlock and press key for 3s, and the digital
tube will display the parameter code "PS1," and enter the setting and adjustment parameters.
Use or key to scroll the parameters, and the display order is as follows: b1→b2→Set→H→L→n→
y→r→S→F→Pt→tH1→P1→Ps1.
Press to confirm the parameter type, and the first parameter name of this type of parameter will be displayed;
①Use or key to scroll the parameters;
②Press key to display the corresponding parameter value;
③Use or to increase or decrease the value ⑥; Press for more than 3s, save the modified
parameters and return to the display parameter category.
④Use to temporarily store the modified values and return to the display parameters;
⑤If other parameters are modified, repeat steps ① to ④.
Type B control panel
ac
b
e
f
g
h
i d
14
15
(optional) (optional)

16
17
6.2 Optional function
1.Printer
Automatic printing:
When the printing interval Pt is not 0, the printer prints the current data every Pt minutes.
Manual printing:
When the key is unlocked and the working voltage is normal, press the print key to display "P01" by the digital tube,
press the up key or down key to adjust "P00~P07." Press the set/mute multiplexing key or print key, and the printer will
cancel the manual printing (P00) or print the data recorded in the previous days (1 ~ 7), with the data interval same as
the automatic printing interval.
Printing paper installation:
The printing paper has been installed at the factory. When the paper is used up after a long time, you may purchase the
same paper for installation. The installation steps are as follows:
① Click the cylindrical button on the printer to open the cover of the printer;
② Put the printing paper into the printer box and pull the paper head of the roll so that the paper slightly exposes from
the upper port of the box cover after the box cover of the printer is closed;;
③ Close the box cover.
4. Parameter display
9
No. Menu
item
Parameter Range Suggested
settings
Remarks
Hardware version
Software version
Temperature setting
Set value of high temperature alarm set+H; When
H =0, High temp alarm is disabled; When the
alarm is over high temp alarm set, H1 will be
displayed on the controller
Set value of low temperature alarm set-L; When L
=0, Low temp alarm is disabled; When the alarm is
below low temp alarm set, L1 will be displayed on
the controller
Print interval
Upper limit of ambient temperature alarm
Mode 1: It shall be judged as once after the door is
opened and closed once and heated for 5min (time
setting). If the door is opened and closed again
during the heating period, the heating time will be
updated again;
Mode 2: When the compressor runs, Heater is on;;
When the compressor stops, the heater Will
automatically off after one min
Mode 3: When the humidity in the cabinet is more
than 80%, the door heating is on, and when the
humidity in the cabinet is moderately less than 60%,
the door heating is off;
Mode 4: Door heating is always on;
Mode 5: Door heating is always off.
1.(Set to 4 when
the door is with
condensation)
(Set to 1 when
the door is a
glass door)
(Set to 5 when
the door is a
foaming door)
1. Automatic
heating mode 1
2. Automatic
heating mode 2
3. Automatic
heating mode 3
4. Always on
5. Always off
PS1 User menu password settings
Alarm Code
Error Description
H1
High temperature alarm
L1
Low temperature alarm
H2
Alarm for high ambient temperature
H3
Condenser overheat alarm
do
Door opening alarm
PF
Power failure alarm
bL
Battery low alarm
Er
The recorder is not connected
LoF
Battery low alarm
EE
Communication failure
5. Alarm display
20
Pt
60-240 min
20.0-50.0℃40.0
tH1
7
5.0
H
40.0-10.0
0.0-10.0 5.0
L
5
-
b1
1-
--
b2
2
20
Set
30.0-10.0
P1
8
0000-9999 0005
5.0

16
17
6.2 Optional function
1.Printer
Automatic printing:
When the printing interval Pt is not 0, the printer prints the current data every Pt minutes.
Manual printing:
When the key is unlocked and the working voltage is normal, press the print key to display "P01" by the digital tube,
press the up key or down key to adjust "P00~P07." Press the set/mute multiplexing key or print key, and the printer will
cancel the manual printing (P00) or print the data recorded in the previous days (1 ~ 7), with the data interval same as
the automatic printing interval.
Printing paper installation:
The printing paper has been installed at the factory. When the paper is used up after a long time, you may purchase the
same paper for installation. The installation steps are as follows:
①Click the cylindrical button on the printer to open the cover of the printer;
②Put the printing paper into the printer box and pull the paper head of the roll so that the paper slightly exposes from
the upper port of the box cover after the box cover of the printer is closed;;
③Close the box cover.
4. Parameter display
9
No. Menu
item
Parameter Range Suggested
settings
Remarks
Hardware version
Software version
Temperature setting
Set value of high temperature alarm set+H; When
H =0, High temp alarm is disabled; When the
alarm is over high temp alarm set, H1 will be
displayed on the controller
Set value of low temperature alarm set-L; When L
=0, Low temp alarm is disabled; When the alarm is
below low temp alarm set, L1 will be displayed on
the controller
Print interval
Upper limit of ambient temperature alarm
Mode 1: It shall be judged as once after the door is
opened and closed once and heated for 5min (time
setting). If the door is opened and closed again
during the heating period, the heating time will be
updated again;
Mode 2: When the compressor runs, Heater is on;;
When the compressor stops, the heater Will
automatically off after one min
Mode 3: When the humidity in the cabinet is more
than 80%, the door heating is on, and when the
humidity in the cabinet is moderately less than 60%,
the door heating is off;
Mode 4: Door heating is always on;
Mode 5: Door heating is always off.
1.(Set to 4 when
the door is with
condensation)
(Set to 1 when
the door is a
glass door)
(Set to 5 when
the door is a
foaming door)
1. Automatic
heating mode 1
2. Automatic
heating mode 2
3. Automatic
heating mode 3
4. Always on
5. Always off
PS1 User menu password settings
Alarm Code Error Description
H1 High temperature alarm
L1 Low temperature alarm
H2 Alarm for high ambient temperature
H3 Condenser overheat alarm
do Door opening alarm
PF Power failure alarm
bL Battery low alarm
Er The recorder is not connected
LoF Battery low alarm
EE Communication failure
5. Alarm display
20
Pt
60-240 min
20.0-50.0℃40.0
tH1
7
5.0
H
40.0-10.0
0.0-10.0 5.0
L
5
-
b1
1-
--
b2
2
20
Set
30.0-10.0
P1
8
0000-9999 0005
5.0

Normally
open Normally
closed
Common
terminal
Remote alarm terminal
Warning:
7. Maintenance and Service
2. Remote alarm terminal and RS485 interface
The remote alarm terminal is installed on the back of the cabinet, and the alarm signal is output by the
terminal. The load-bearing capacity of the terminal is 30V, 2A DC. Users can choose normally open, normally
closed and common terminals according to their own needs.
18
19
®In order to prevent people from getting electric shock or injury, please cut off the power supply of the equipment before
any repairs and maintenance
®Make sure you don't inhale drugs or suspended particles around it when maintaining the equipment, otherwise it will
harm your health
7.1 Equipment Maintenance
Defrosting: The equipment will automatically defrost during the working process for the convenience of use.
Cleaning and maintenance: The equipment should be cleaned and maintained regularly (for safety, please unplug
the power plug), and the inner and outer surfaces of the cabinet should be wiped with a warm, damp soft cloth.
Notes:
®Do not sprinkle water directly on the cabinet, lest the insulation performance of electrical components decrease and
metal parts rust.
®Do not use hot water, corrosive detergent or organic solvent to clean the cabinet
®Do not place heavy objects on top of the equipment, as the equipment may deform under pressure.
7.2 Equipment Discontinuation
Deactivation: If the equipment is stored in an unsupervised area for a long time and not used, the power supply
should be cut off and the inner and outer surfaces of the cabinet should be cleaned with a warm, damp soft cloth,
aired and sealed. The equipment must be locked to ensure that children cannot open the cabinet door.
Scrapping: When the equipment reaches the end of its service life, it should be scrapped and must be handed over
to a qualified professional recycling agency for disposal per local regulations. Non-professionals are not allowed to
disassemble and break down the equipment without authorization. The scrapped equipment should be placed in a
designated area inaccessible to children to avoid danger.
7.3 Maintenance, Replacement, and Recovery of Rechargeable Batteries
Battery installation position: top of the cabinet and bottom inside the electrical box.
1. Battery maintenance
① In order to prolong the service life of the battery and avoid the product being left unused for a long time, the
product must be operated for more than 24 hours every month to facilitate charging.
② When the equipment is not used for a long time, it should be connected to the working power regularly (generally
once a month), and the power lock switch should be turned on so that the equipment can run for a period of time to
complete charging, and each charging time should be no less than 24 hours;
③ When the working power supply is interrupted, the power lock switch of the equipment shall be turned off in time,
otherwise it will cause power loss in battery and even permanent damage to the battery in severe cases;
④The main power switch must be turned off during a long-term power outage or during transportation, otherwise
long-term discharge causes power loss in battery and even permanent damage to the battery, and the display is
abnormal after re-energizing;
⑤The battery is a consumable, with a service life of about 2-3 years. If the battery is used improperly, such as
power loss or reaching the end of battery life, it will cause a low battery alarm (refrigeration is not affected, but there
is an alarm failure and influence to the use function of the printer, please contact the after-sales staff of local
distributors for replacement).
2. Battery replacement and recovery
①Turn off the power switch and pull out the power plug from the outlet;
② Remove the screws on the electrical box with a screwdriver. (Note: There are high-voltage electrical components
in the electrical box, therefore before opening, turn off the power supply, unplug the power plug and turn off the
power lock switch of the refrigerator, and the electrical box can only be opened by qualified engineers or
maintenance personnel).
③ Pull out the battery connecting cable; (Before unplugging the battery fixing cable, pay attention to the
cathode/anode of the battery and the sequence of the connecting cables, so as to prevent burning down the control
system due to installation of the new battery with cathode/anode reversed. Generally, the red wire is connected to
the cathode, and the black wire is connected to the anode.
④ Use a screwdriver to remove the fastening screws on the battery fixing plate and take out the battery;
⑤The battery model BT-12M1. 3AT (12V) is suitable for (YC-55L/EL, YC-75L/EL), and the rest of the products are
BT-12M4. 0AC (12V4. 0AH);
⑥ For a replaced battery that can be recycled, please contact the local battery recycling agency.
Tips: In order to effectively ensure that the battery replacement meets the requirements of the control system and
avoid the influence of improper operation on the system, please contact our after-sales personnel for replacement
or guidance.
RS-485
This manual suits for next models
3
Table of contents
Popular Refrigerator manuals by other brands

Bosch
Bosch KGN56 Series user manual

Continental Refrigerator
Continental Refrigerator CRB42-9M Specifications

Siemens
Siemens KU..R.. series Instructions for use

Igloo
Igloo IGLOO FR1008 Preliminary specification sheet

Nordcap
Nordcap TKU 440 G-LED user manual

Indesit
Indesit SDSY 17 Series operating instructions

Alfresco
Alfresco ARDI-C Dimensional information

Hoshizaki
Hoshizaki Premier BW80 Operation, maintenance and installation manual

Hotpoint
Hotpoint 19 Owner's manual and installation instructions

Thermo King
Thermo King RD-II MAX manual

LG
LG LSC27921 Series owner's manual

Smeg
Smeg FI167STB Notice d'utilisation