WMCM
WDX

2
PREFACE
This manual is provided to prevent service personnel from committing
an act that results in the risk of re, electric shock, or injury to persons.
Only trained service personnel should receive, unpack, and assemble
a Great Lakes wall mount. In addition, only trained service personnel
should install equipment in wall mounts.
SAFETY SYMBOLS USED IN THIS MANUAL
This manual provides general safety guidelines to be observed during
installation, operation, and maintenance of the GL wall mount.
WARNING: Failure to follow directions in the warning could result in
injury to persons or loss of life.
CAUTION: Failure to follow directions in the caution could result in
damage to equipment or storage data.
SAFETY CONSIDERATIONS
WARNING: Improper handling and use of the Great Lakes wall mount
could result in equipment damage, serious injury, or possible death.
Only trained service personnel should be used to remove the wall
mount from its packaging. Also, be sure you have a sucient number
of service personnel. Do not attempt to move wall mount by yourself.
Only UL® Listed ITE (Information Technology Equipment) units should
be installed inside the Great Lakes wall mount.
Be sure to read and follow all individual manufacturer equipment
manuals for safety and installation instructions.
Proper spacing is required when installing electrical equipment
to avoid electrical shock. Maintain minimum spacing between the
accessories; components and the wall mount for safe operation of the
equipment when installed in accordance with the National Electrical
Code ANSI/NFPA 70-1999.
The ambient temperature operating range for the Great Lakes wall
mount and accessories is +50 to +95° F (+10 to +35° C).
The non-operating temperature is -4 to +140° F (-20 to +60° C).

3
INSTALLATION
Receiving and Unpacking
Inspect and report any damage before receiving. Unpack the wall
mount by carefully removing the corrugated carton and corners.
Avoid damaging the wall mount when removing packaging.
WARNING: Only trained service personnel should be used to unpack
and move the wall mount. Also, be sure you have a sucient number
of service personnel. Do not attempt to move wall mount by yourself.
MOUNTING INSTRUCTIONS
Wood Studded Wall
Once the location on the wall has been determined, inspect the wall
surface. The wall must be at and square in the horizontal and vertical
plane to ensure the Great Lakes wall mount closes correctly. If the wall
is not at and square, the use of shims may be required.
Wood studded wall mounting instructions apply to a 2" x 4" wood stud
wall with 3/4" plywood.
Recommended Mounting Hardware for Wood Studded Wall
For WM, WE, and 15WM Series:
Qty. (4) 3/8 x 2" long Lag Bolts and 1" O.D. Flat Washer
For WMCM, WDX, WLP and NEMA 12K Series:
Qty. (4) 3/8 x 2 1/2" long Lag Bolts and 1" O.D. Flat Washer
Masonry Wall Surface
For masonry wall surface, the installer must provide all the appropriate
hardware.
PROTECTIVE GROUNDING
Protective grounding studs are provided along with grounding jumper
wires that electrically bond the wall mount door to the wall mount
frame.

4
Part No. Height (in.) Width (in.) Depth (in.) RMU Wt. Cap. (lbs.)
GL24WMCM 24.00 24.00 30.54 12 150
GL36WMCM 36.00 24.00 30.54 19 250
GL48WMCM 48.00 24.00 30.54 25 350
GL24WDX 24.00 24.00 32.07 12 250
GL36WDX 36.00 24.00 32.07 19 300
GL48WDX 48.00 24.00 32.07 25 350
GL2418WM 24.00 21.25 18.00 12 100
GL24WM 24.00 21.25 24.54 12 150
GL36WM 36.00 21.25 24.54 19 250
GL48WM 48.00 21.25 24.54 25 350
GL24WD 24.00 24.00 32.13 11 250
GL36WD 36.00 24.00 32.13 18 300
GL48WD 48.00 24.00 32.13 25 350
GL15WM 15.38 22.25 17.66 7 100
GL24WE 24.00 36.10 20.50 10 350
GLGL24WLP 24.00 27.00 10.00 4 105
GLGL36WLP 36.00 27.00 10.00 4 105
GLGL48WLP 48.00 27.00 10.00 4 105
GL240N12 24.00 24.00 24.00 12 150
GL360N12 36.00 24.00 24.00 19 250
GL480N12 48.00 24.00 24.00 26 300
WARNING: Only install equipment after the wall mount has been
properly secured. Do not move the wall mount assembly while loaded.
To maintain a uniform distribution of the mechanical load in the wall
mount, load the heaviest equipment rst, at the bottom of the wall
mount and load the lighter units at the top. Rated or maximum load
capacities for the wall mounts are as follows:
Loading Equipment

5
WARNING: To avoid injury to persons or loss of life, ground each
cabinet individually to the dedicated branch circuit ground.
Connecting Main Protective Grounding Stud to the Dedicated
Branch Circuit Ground-
Connect the dedicated branch circuit ground connector to the main
protective grounding stud located inside on the back of the rear
section on the WMCM, WM, WDX, WE and inside on the side of the
15WM Series using a listed ring or closed-loop terminal.
Connecting Main Protective Grounding Stud to the Protective
Bonding Conductors-
Connect the middle wall mount frame on the WM and WD Series to
the main protective grounding stud located inside on the back of the
rear section using a listed ring or closed-loop terminal. Connect the
wall mount frame on the WE and 15WM Series to the main protective
grounding stud located inside on the back of the rear section on the
WE Series and inside on the side of the 15WM Series using a listed
ring or closed-loop terminal. Connect the front door to the grounding
stud located inside at the side of the wall mount frame using a listed
ring or closed-loop terminal.
Parts Not Bonded to Protective Earthing Terminal-
The following parts are not eectively bonded to the protective
earthing terminal: rails. If these parts need to be bonded to the
protective earthing terminal, do so in accordance with Article 250 of
the National Electrical Code.
POWER AND GROUNDING

6
18.31
TO
17.75 INSIDE
RMU
24.00
HEIGHT
19.23 OPENING
5.00
30.54 1.25 16.00
TO
6.75
1.40
KEYHOLEMOUNTING
CENTERED
3.758.2512.00
18.31
TO
17.75 INSIDE
RMU
24.00
HEIGHT
19.23 OPENING
5.00
30.54 1.25 16.00 TO 6.75
1.40
KEYHOLEMOUNTING
CENTERED
3.758.2512.00
WMCM SERIES WALL MOUNT
1. Mounting holes are designed for 3/8" hardware, 16" on center.
2. Use the template on the shipping box to locate your mounting holes.
3. Wall mount comes hinged right from the manufacturer. For mounting hinged left,
rotate wall mount 180o and follow additional steps on page 8.
1", 2" and 3" nominal
concentric conduit
knockouts on top,
bottom and non-
hinged side of
rear section
Heavy duty
hinges
Front door
Center swing section
Offset 19" EIA
mounting rails;
2 pairs,
tapped #12-24
Independent
locking front
door & rear
section
Rear section
mounts to wall
Provision for optional
fan assembly (7217WS)
FRONT VIEW WITHOUT DOOR
18.31
TO
17.75 INSIDE
RMU
24.00
HEIGHT
19.23 OPENING
5.00
30.54 1.25 16.00
TO
6.75
1.40
KEYHOLEMOUNTING
CENTERED
3.758.2512.00
17.76 Inside
18.31 C-to-C
21.84 Open Access
FRONT VIEW WITH DOOR
24.00
HEIGHT
Swing handle
locking, keyed
1333 (optional
handles
available)
RMU
Cable tie
points on top,
bottom and
non-hinged
side

7
18.31
TO
17.75 INSIDE
RMU
24.00
HEIGHT
19.23 OPENING
5.00
30.54 1.25 16.00
TO
6.75
1.40
KEYHOLEMOUNTING
CENTERED
3.758.2512.00
18.31
TO
17.75 INSIDE
RMU
24.00
HEIGHT
19.23 OPENING
5.00
30.54 1.25 16.00
TO
6.75
1.4
0
KEYHOLEMOUNTING
CENTERED
3.758.2512.00
TOP/BOTTOM VIEW REAR VIEW
1", 2" and 3" rear section with
nominal concentric conduit
knockout
18.31 TO
17.75 INSIDE
RMU
24.00
HEIGHT
19.23 OPENING
5.00
30.54
1.25 16.00 TO 6.75
1.40
KEYHOLEMOUNTING
CENTERED
3.758.2512.00
30.54
5.0
Cable
management
area outside
of EIA on
hinge side
INTERNAL TOP VIEW
Front
door
1.25
1.50
MTGHOLES
TO
21.84 OPEN ACCESS
12-24 UNC - 2B#
29.00 USEABLE DEPTH
23.38 MAX RAIL SPACING
17.87 INSIDE
24.00
24.00 6.75
30.54
RMU
.63
.63
.50
1.75
PATTERN
REPEATS
12.00 8.25
CENTERED
18.31 TO
1.00
.25
.13
Usable depth = 28.00
23.38 Max rail spacing
3.41 Max cable
area width
Optional 1/4
turn “D” ring
Square
holes for
CM-25
1/4 turn
“D” rings
1.25
1.50
MTGHOLES
TO
21.84 OPEN ACCESS
12-24 UNC - 2B
#
29.00 USEABLE DEPTH
23.38 MAX RAIL SPACING
17.87 INSIDE
24.00
24.00 6.75
30.54
RMU
.63
.63
.50
1.75
PATTERN
REPEATS
12.00 8.25
CENTERED
18.31
TO
1.00
.25
.13
Cable management tie points
on rails; outside of EIA
SIDE VIEW
WMCM SERIES WALL MOUNT
1.25
Mounting Holes
19", 24" and 36"
Mounting
holes for
3/8"hardware
1.50
16.00 C-TO-C 6.75
1.25
1.50
MTGHOLES
TO
21.84 OPEN ACCESS
12-24
UNC - 2B
#
29.00 USEABLE DEPTH
23.38 MAX RAIL SPACING
17.87 INSIDE
24.00
24.00 6.75
30.54
RMU
.63
.63
.50
1.75
PATTERN
REPEATS
12.00 8.25
CENTERED
18.31
TO
1.00
.25
.13
1.75
(1 RMU)
#12-24
Tapped
holes
EQUIPMENT
MOUNTING
RAIL DETAIL
18.31 TO
17.75 INSIDE
RMU
24.00
HEIGHT
19.23 OPENING
5.00
30.54 1.25 16.00 TO 6.75
1.40
KEYHOLEMOUNTING
CENTERED
3.758.2512.00
1", 2" and 3" rear section with
nominal concentric conduit knockout
Provision for optional fan
assembly (7217WS)
12.00 8.25 3.75
Centered
.63
.63
.50
Side ventilation
Additional
tie points

8
(.50) THK
Standard
at cam
supplied
Swing-latch handle;
pull out and rotate
to open and close
Move draw latch
to now top of
center section
Flip rear guide bracket and install
on now bottom of center section;
guide bracket should be oriented
with handle and pointing up
Remove center section
of gasket on now
bottom of rear section
Move receiving
bracket to now
top of rear
section
Add additional strip
of gasket (included) to
now top of rear section
REVERSING THE WALL MOUNT - LEFT HAND HINGE
Flip handle on
door 180o; flip
cam on inside of
handle 180o
WMCM SERIES WALL MOUNT

9
WDX SERIES WALL MOUNT
1. Mounting holes are designed for 3/8" hardware, 16.00" on center.
2. Use the template on the shipping box to locate your mounting holes.
3. Wall mount comes hinged right from the manufacturer.
A A
B
15.984
TO
3.89
18.82
TO
USEABLE DEPTH = 28.00
32.07
5.2824.29
23.81
29.00 USEABLE DEPTH
20.93 MAX
RAIL SPACING
17.70
OPENING
4.13
OPENING
21.26 OPEN ACCESS
18.31
TO
17.76 INSIDE
3.94
2.56
.50
.63
.63
1.75 (1RMU)
REPEATING
19.921
TO
1.92
23.43
Removable gland plate exposes provision
for optional 2 fan assembly (7217WS)
Cover plate with 1",
2", and 3" nominal
concentric conduit
knockouts
Front door frame
with optional
inserts: solid steel,
mesh or plexi
Center swing section
Rear section
mounts to
wall
Independent
locking front
door & rear
section
A A
A
I
15.984
TO
3.89
MTGHOLES
TO
USEABLE DEPTH = 28.00
32.07
5.2824.29
OPEN
AREA
IN REAR
28.00 USEABLE DEPTH
17.70
21.26 OPEN ACCESS
18.31
TO
17.76 INSIDE
3.94
2.56
.50
.63
.63
19.921
TO
1.92
23.43
RMU
21.26 Open Access
FRONT VIEW WITHOUT DOOR
17.76 Inside
18.31 C-to-C
A A
B
15.984
TO
3.89
18.82TO
USEABLE DEPTH = 28.00
32.07
5.2824.29
23.81
29.00 USEABLE DEPTH
20.93 MAX
RAIL SPACING
17.70
OPENING
4.13
OPENING
21.26 OPEN ACCESS
18.31
TO
17.76 INSIDE
3.94
2.56
.50
.63
.63
1.75 (1RMU)
REPEATING
19.921
TO
1.92
23.43
Swing
handle
locking,
keyed
1333
(optional
handles
available)
FRONT VIEW WITH DOOR
23.81
HEIGHT
Vent pattern
RMU

10
A A
B
15.984
TO
3.89
18.82TO
USEABLE DEPTH = 28.00
32.07
5.2824.29
23.81
29.00 USEABLE DEPTH
20.93 MAX
RAIL SPACING
17.70
OPENING
4.13
OPENING
21.26 OPEN ACCESS
18.31
TO
17.76 INSIDE
3.94
2.56
.50
.63
.63
1.75 (1RMU)
REPEATING
19.921
TO
1.92
23.43
32.07
24.29 5.28
Usable depth = 28.00
1", 2", and 3" nominal concentric conduit
knockouts (knockouts on right side only) 3.94
2.56
RIGHT SIDE VIEW
A A
B
15.984
TO
3.89
18.82TO
USEABLE DEPTH = 28.00
32.07
5.2824.29
23.81
29.00 USEABLE DEPTH
20.93 MAX
RAIL SPACING
17.70
OPENING
4.13
OPENING
21.26 OPEN ACCESS
18.31
TO
17.76 INSIDE
3.94
2.56
.50
.63
.63
1.75 (1RMU)
REPEATING
19.921
TO
1.92
23.43
Usable depth = 28.00
20.93 max
rail spacing
INTERNAL TOP VIEW
A A
B
15.984
TO
3.89
18.82TO
USEABLE DEPTH = 28.00
32.07
5.2824.29
23.81
29.00 USEABLE DEPTH
20.93 MAX
RAIL SPACING
17.70
OPENING
4.13
OPENING
21.26 OPEN ACCESS
18.31
TO
17.76 INSIDE
3.94
2.56
.50
.63
.63
1.75 (1RMU)
REPEATING
19.921
TO
1.92
23.43
Open
area in
rear
19.921 C-to-C
15.984 C-to-C
1.92
3.89
Mounting Holes
18.82", 31.46"
and 31.76"
REAR VIEW
A A
B
15.984
TO
3.89
18.82TO
USEABLE DEPTH = 28.00
32.07
5.2824.29
23.81
29.00 USEABLE DEPTH
20.93 MAX
RAIL SPACING
17.70
OPENING
4.13
OPENING
21.26 OPEN ACCESS
18.31
TO
17.76 INSIDE
3.94
2.56
.50
.63
.63
1.75 (1RMU)
REPEATING
19.921
TO
1.92
23.43
.50
.63
.63
1.75
(1 RMU)
repeating
3/8" square EIA mounting
holes with cage nuts (M6)
A A
B
15.984
TO
3.89
18.82TO
USEABLE DEPTH = 28.00
32.07
5.2824.29
23.81
29.00 USEABLE DEPTH
20.93 MAX
RAIL SPACING
17.70
OPENING
4.13
OPENING
21.26 OPEN ACCESS
18.31
TO
17.76 INSIDE
3.94
2.56
.50
.63
.63
1.75 (1RMU)
REPEATING
19.921
TO
1.92
23.43
Cover plate with 1", 2",
and 3" nominal concentric
conduit knockouts
17.70" opening
Provision for optional 2
fan assembly (7217WS)
TOP VIEW
WDX SERIES WALL MOUNT
EQUIPMENT MOUNTING
RAIL DETAIL

11
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
WDX SERIES WALL MOUNT
REVERSING THE CENTER SECTION
1. Remove flat head bolt on top hinge mechanism
2. Lift center section off bottom hinge collar pin
3. After bottom hinge collar pin is moved, align with new hinge location on
center section
4. Move bushing in center section to opposite side and install top hinge mechanism
on opposite side
Remove bolt in
center section
alignment pin and
move to opposite
side
Notch gasket
for new
alignment
pin and cam
latch location
Move bottom
hinge collar pin
to opposite side
of rear section
(see step 3)
Remove collar
bolt on stop
bracket and
move, with
bushing, to
opposite side
weld nut in rear
section
Move
bumpers
to opposite
side of rear
section
Move quarter
turn latch to
opposite side of
rear section
Move hole
plugs in top of
rear section to
opposite side
Move bushing in center section to
opposite side and install top hinge
mechanism on opposite side

12
WM SERIES WALL MOUNT
1. Mounting holes are designed for 3/8" hardware, 16.00" on center.
2. Use the template on the shipping box to locate your mounting holes.
SECTION E-E
RIGHT SIDE VIEW
A
E
E
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
FRONT VIEW
(without Door)
FRONT VIEW
(with Door)
BOTTOM VIEW
ISO COLLAPSED
(without Door)
ISO VIEW OPENED
19.17
21.25
18.31 TO
HEIGHT
10.63
12.00
7.386.50
16.00 TO
2.55
1.50
MTGHOLES
PART No. HEIGHT DEPTH USABLE DEPTH MAX. RAIL SPACING RMU WEIGHT CAPACITY MTG HOLES
GL2418WM 24.00" 18.00" 16.0" 11.06" 12 150 LBS 19.00"
GL24WM 24.00" 24.50" 22.0" 17.62" 12 150 LBS 19.00"
GL36WM 36.00" 24.50" 22.0" 17.62" 19 250 LBS 31.00"
GL48WM 48.00" 24.50" 22.0" 17.62" 25 300 LBS 21.50" (3 LOCATIONS)
INDEPENDENT LOCKING FRONT
AND REAR DOOR SECTION
MOUNTING HOLES FOR
3/8" HARDWARE
SPECIFICATIONS: WM WALL MOUNT
RACK SPACES: 19" EIA 310-E COMPLIANT - SEE CHART FOR RMU
COLOR: DURABLE BLACK TEXTURED POWDER COAT.
FEATURES: 2 PAIR OF FULLY ADJUSTABLE #12-24 THREADED MOUNTING RAILS, #12 GA.
1, 2, AND 3" CODUIT AND HORSESHOE KNOCKOUTS ON TOP AND BOTTOM OF REAR SECTION.
SOLID STEEL OR PLEXIGLASS DOORS.
FULL PIANO HINGE PROVIDES ADDED STRENGTH FOR REAR SECTION.
DUST KIT AVAILABLE.
CENTER SWING-OUT SECTION PROVIDES FRONT/REAR ACCESS TO CABLES.
REVERSIBLE CABINET FOR LEFT OR RIGHT HAND SWING-OUT.
WEIGHT TESTED TO 1/2" OF DEFLECTION.
OPTIONAL FRONT DOOR INSERTS
SOLID STEEL PANEL - 24WDX03
PERFORATED STEEL PANEL - MESH24WS
PLEXI PANEL - PLEX24WS
.63
.63
.50
RMU
3.50
DEPTH
MAX RAIL SPACING
USABLE DEPTH
SECTION E-E
RIGHT SIDE VIEW
A
E
E
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
FRONT VIEW
(without Door)
FRONT VIEW
(with Door)
BOTTOM VIEW
ISO COLLAPSED
(without Door)
ISO VIEW OPENED
19.17
21.25
18.31 TO
HEIGHT
10.63
12.00
7.386.50
16.00 TO
2.55
1.50
MTGHOLES
PART No. HEIGHT DEPTH USABLE DEPTH MAX. RAIL SPACING RMU WEIGHT CAPACITY MTG HOLES
GL2418WM 24.00" 18.00" 16.0" 11.06" 12 150 LBS 19.00"
GL24WM 24.00" 24.50" 22.0" 17.62" 12 150 LBS 19.00"
GL36WM 36.00" 24.50" 22.0" 17.62" 19 250 LBS 31.00"
GL48WM 48.00" 24.50" 22.0" 17.62" 25 300 LBS 21.50" (3 LOCATIONS)
INDEPENDENT LOCKING FRONT
AND REAR DOOR SECTION
MOUNTING HOLES FOR
3/8" HARDWARE
SPECIFICATIONS: WM WALL MOUNT
RACK SPACES: 19" EIA 310-E COMPLIANT - SEE CHART FOR RMU
COLOR: DURABLE BLACK TEXTURED POWDER COAT.
FEATURES: 2 PAIR OF FULLY ADJUSTABLE #12-24 THREADED MOUNTING RAILS, #12 GA.
1, 2, AND 3" CODUIT AND HORSESHOE KNOCKOUTS ON TOP AND BOTTOM OF REAR SECTION.
SOLID STEEL OR PLEXIGLASS DOORS.
FULL PIANO HINGE PROVIDES ADDED STRENGTH FOR REAR SECTION.
DUST KIT AVAILABLE.
CENTER SWING-OUT SECTION PROVIDES FRONT/REAR ACCESS TO CABLES.
REVERSIBLE CABINET FOR LEFT OR RIGHT HAND SWING-OUT.
WEIGHT TESTED TO 1/2" OF DEFLECTION.
OPTIONAL FRONT DOOR INSERTS
SOLID STEEL PANEL - 24WDX03
PERFORATED STEEL PANEL - MESH24WS
PLEXI PANEL - PLEX24WS
.63
.63
.50
RMU
3.50
DEPTH
MAX RAIL SPACING
USABLE DEPTH
18.31 C-to-C
FRONT VIEW WITHOUT DOOR
FRONT VIEW WITH DOOR
21.25
19.17
RMU
HEIGHT
12.00
10.63
DETAIL A
DETAIL B
1
1
2
2
3
3
4
4
5
5
6
6
A A
B B
C C
D D
DWGNO: REV
SHEET: OF
DRAWN
CHECKED & APP.
TITLE
DRAWINGNOT T O SCALE
PARTNUMBER:
QTYPER U NIT: 1
MATERIALTYPE:
MATERIAL GAUGE:
FINISH:
GREAT LAKES CASE & CABINET CO., INC.
P.O. BOX 551 EDINBORO, PA 16412
PHONE(814) 734-7303 FAX (814) 734-3907
E-MAILglcc@greatcabinets.com
Use of this document is subject to
a confidentiality and nondisclosure
agreement with Great Lakes Case
& Cabinet Co., Inc. (GLCC) and may
not be reproduced,disclosed or
utilized in whole orin part without
prior written authorization from GLCC.
NOTICE:
TOLERANCE UNLESS OTHERWISE NOTED:
ANGULAR+/- 1~
.XXXX+/- . 010
.XXX+/- .015
.XX+/- .030
.X FOR RE F. ONLY
UNLESSOTHERWI SE SPECIFIED
ALLDIMEN SIONS ARE IN INCHES
DIMENSIONAL LIMITS APPLY
AFTERAPPLI CATION OF FINISH
INTERPRET DRAWING PER ASME Y14.5M-1994
THIRD ANGLE
PROJECTION
DATE
DATE 11
ANDY 10/5/2007
cable latch detail
Use latch supplied in hardware bag,
when horseshoe knockout is used
Rear section
1", 2" and 3" nominal
concentric conduit
knockouts and
horseshoe knockouts;
top & bottom rear
section
Continuous Hinges
on front door & rear
section
Front door
Provision for optional 2 fan
assembly (7217WS)
Center swing section
19" EIA mounting rails;
2 pairs, tapped #12-24
Independent
locking front door
& rear section
UL60950-1
UL2416

13
SECTION E-E
RIGHT SIDE VIEW
A
E
E
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
FRONT VIEW
(without Door)
FRONT VIEW
(with Door)
BOTTOM VIEW
ISO COLLAPSED
(without Door)
ISO VIEW OPENED
19.17
21.25
18.31 TO
HEIGHT
10.63
12.00
7.386.50
16.00 TO
2.55
1.50
MTGHOLES
PART No. HEIGHT DEPTH USABLE DEPTH MAX. RAIL SPACING RMU WEIGHT CAPACITY MTG HOLES
GL2418WM 24.00" 18.00" 16.0" 11.06" 12 150 LBS 19.00"
GL24WM 24.00" 24.50" 22.0" 17.62" 12 150 LBS 19.00"
GL36WM 36.00" 24.50" 22.0" 17.62" 19 250 LBS 31.00"
GL48WM 48.00" 24.50" 22.0" 17.62" 25 300 LBS 21.50" (3 LOCATIONS)
INDEPENDENT LOCKING FRONT
AND REAR DOOR SECTION
MOUNTING HOLES FOR
3/8" HARDWARE
SPECIFICATIONS: WM WALL MOUNT
RACK SPACES: 19" EIA 310-E COMPLIANT - SEE CHART FOR RMU
COLOR: DURABLE BLACK TEXTURED POWDER COAT.
FEATURES: 2 PAIR OF FULLY ADJUSTABLE #12-24 THREADED MOUNTING RAILS, #12 GA.
1, 2, AND 3" CODUIT AND HORSESHOE KNOCKOUTS ON TOP AND BOTTOM OF REAR SECTION.
SOLID STEEL OR PLEXIGLASS DOORS.
FULL PIANO HINGE PROVIDES ADDED STRENGTH FOR REAR SECTION.
DUST KIT AVAILABLE.
CENTER SWING-OUT SECTION PROVIDES FRONT/REAR ACCESS TO CABLES.
REVERSIBLE CABINET FOR LEFT OR RIGHT HAND SWING-OUT.
WEIGHT TESTED TO 1/2" OF DEFLECTION.
OPTIONAL FRONT DOOR INSERTS
SOLID STEEL PANEL - 24WDX03
PERFORATED STEEL PANEL - MESH24WS
PLEXI PANEL - PLEX24WS
.63
.63
.50
RMU
3.50
DEPTH
MAX RAIL SPACING
USABLE DEPTH
SECTION E-E
RIGHT SIDE VIEW
A
E
E
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
FRONT VIEW
(without Door)
FRONT VIEW
(with Door)
BOTTOM VIEW
ISO COLLAPSED
(without Door)
ISO VIEW OPENED
19.17
21.25
18.31 TO
HEIGHT
10.63
12.00
7.386.50
16.00 TO
2.55
1.50
MTGHOLES
PART No. HEIGHT DEPTH USABLE DEPTH MAX. RAIL SPACING RMU WEIGHT CAPACITY MTG HOLES
GL2418WM 24.00" 18.00" 16.0" 11.06" 12 150 LBS 19.00"
GL24WM 24.00" 24.50" 22.0" 17.62" 12 150 LBS 19.00"
GL36WM 36.00" 24.50" 22.0" 17.62" 19 250 LBS 31.00"
GL48WM 48.00" 24.50" 22.0" 17.62" 25 300 LBS 21.50" (3 LOCATIONS)
INDEPENDENT LOCKING FRONT
AND REAR DOOR SECTION
MOUNTING HOLES FOR
3/8" HARDWARE
SPECIFICATIONS: WM WALL MOUNT
RACK SPACES: 19" EIA 310-E COMPLIANT - SEE CHART FOR RMU
COLOR: DURABLE BLACK TEXTURED POWDER COAT.
FEATURES: 2 PAIR OF FULLY ADJUSTABLE #12-24 THREADED MOUNTING RAILS, #12 GA.
1, 2, AND 3" CODUIT AND HORSESHOE KNOCKOUTS ON TOP AND BOTTOM OF REAR SECTION.
SOLID STEEL OR PLEXIGLASS DOORS.
FULL PIANO HINGE PROVIDES ADDED STRENGTH FOR REAR SECTION.
DUST KIT AVAILABLE.
CENTER SWING-OUT SECTION PROVIDES FRONT/REAR ACCESS TO CABLES.
REVERSIBLE CABINET FOR LEFT OR RIGHT HAND SWING-OUT.
WEIGHT TESTED TO 1/2" OF DEFLECTION.
OPTIONAL FRONT DOOR INSERTS
SOLID STEEL PANEL - 24WDX03
PERFORATED STEEL PANEL - MESH24WS
PLEXI PANEL - PLEX24WS
.63
.63
.50
RMU
3.50
DEPTH
MAX RAIL SPACING
USABLE DEPTH
TOP/BOTTOM VIEW
INTERNAL SIDE VIEW
2 fan unit mounting
shown for GL24WM,
GL36WM and
GL48WM; 2 fan unit
is rotated 90oon
GL2418WM
1", 2", and 3" rear
section nominal
concentric conduit
knockouts
WM SERIES WALL MOUNT
6.50
7.38
SECTION E-E
RIGHT SIDE VIEW
A
E
E
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
FRONT VIEW
(without Door)
FRONT VIEW
(with Door)
BOTTOM VIEW
ISO COLLAPSED
(without Door)
ISO VIEW OPENED
19.17
21.25
18.31 TO
HEIGHT
10.63
12.00
7.386.50
16.00 TO
2.55
1.50
MTGHOLES
PART No. HEIGHT DEPTH USABLE DEPTH MAX. RAIL SPACING RMU WEIGHT CAPACITY MTG HOLES
GL2418WM 24.00" 18.00" 16.0" 11.06" 12 150 LBS 19.00"
GL24WM 24.00" 24.50" 22.0" 17.62" 12 150 LBS 19.00"
GL36WM 36.00" 24.50" 22.0" 17.62" 19 250 LBS 31.00"
GL48WM 48.00" 24.50" 22.0" 17.62" 25 300 LBS 21.50" (3 LOCATIONS)
INDEPENDENT LOCKING FRONT
AND REAR DOOR SECTION
MOUNTING HOLES FOR
3/8" HARDWARE
SPECIFICATIONS: WM WALL MOUNT
RACK SPACES: 19" EIA 310-E COMPLIANT - SEE CHART FOR RMU
COLOR: DURABLE BLACK TEXTURED POWDER COAT.
FEATURES: 2 PAIR OF FULLY ADJUSTABLE #12-24 THREADED MOUNTING RAILS, #12 GA.
1, 2, AND 3" CODUIT AND HORSESHOE KNOCKOUTS ON TOP AND BOTTOM OF REAR SECTION.
SOLID STEEL OR PLEXIGLASS DOORS.
FULL PIANO HINGE PROVIDES ADDED STRENGTH FOR REAR SECTION.
DUST KIT AVAILABLE.
CENTER SWING-OUT SECTION PROVIDES FRONT/REAR ACCESS TO CABLES.
REVERSIBLE CABINET FOR LEFT OR RIGHT HAND SWING-OUT.
WEIGHT TESTED TO 1/2" OF DEFLECTION.
OPTIONAL FRONT DOOR INSERTS
SOLID STEEL PANEL - 24WDX03
PERFORATED STEEL PANEL - MESH24WS
PLEXI PANEL - PLEX24WS
.63
.63
.50
RMU
3.50
DEPTH
MAX RAIL SPACING
USABLE DEPTH
REAR VIEW
Mounting holes for
3/8" hardware
1", 2", and 3" rear
section nominal
concentric conduit
knockouts
3.50
Mounting Holes
19", 31" and
21.50 (3)"
2.55
1.50
16.00 C to C
SECTION E-E
RIGHT SIDE VIEW
A
E
E
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
FRONT VIEW
(without Door)
FRONT VIEW
(with Door)
BOTTOM VIEW
ISO COLLAPSED
(without Door)
ISO VIEW OPENED
19.17
21.25
18.31 TO
HEIGHT
10.63
12.00
7.386.50
16.00 TO
2.55
1.50
MTGHOLES
PART No. HEIGHT DEPTH USABLE DEPTH MAX. RAIL SPACING RMU WEIGHT CAPACITY MTG HOLES
GL2418WM 24.00" 18.00" 16.0" 11.06" 12 150 LBS 19.00"
GL24WM 24.00" 24.50" 22.0" 17.62" 12 150 LBS 19.00"
GL36WM 36.00" 24.50" 22.0" 17.62" 19 250 LBS 31.00"
GL48WM 48.00" 24.50" 22.0" 17.62" 25 300 LBS 21.50" (3 LOCATIONS)
INDEPENDENT LOCKING FRONT
AND REAR DOOR SECTION
MOUNTING HOLES FOR
3/8" HARDWARE
SPECIFICATIONS: WM WALL MOUNT
RACK SPACES: 19" EIA 310-E COMPLIANT - SEE CHART FOR RMU
COLOR: DURABLE BLACK TEXTURED POWDER COAT.
FEATURES: 2 PAIR OF FULLY ADJUSTABLE #12-24 THREADED MOUNTING RAILS, #12 GA.
1, 2, AND 3" CODUIT AND HORSESHOE KNOCKOUTS ON TOP AND BOTTOM OF REAR SECTION.
SOLID STEEL OR PLEXIGLASS DOORS.
FULL PIANO HINGE PROVIDES ADDED STRENGTH FOR REAR SECTION.
DUST KIT AVAILABLE.
CENTER SWING-OUT SECTION PROVIDES FRONT/REAR ACCESS TO CABLES.
REVERSIBLE CABINET FOR LEFT OR RIGHT HAND SWING-OUT.
WEIGHT TESTED TO 1/2" OF DEFLECTION.
OPTIONAL FRONT DOOR INSERTS
SOLID STEEL PANEL - 24WDX03
PERFORATED STEEL PANEL - MESH24WS
PLEXI PANEL - PLEX24WS
.63
.63
.50
RMU
3.50
DEPTH
MAX RAIL SPACING
USABLE DEPTH
1.75
(1 RMU)
repeating
#12-24 Tapped EIA mounting holes
Usable depth 22.00
18" max. rail spacing
EQUIPMENT MOUNTING
RAIL DETAIL
GL2418WM usable depth -16.00";
max. rail spacing, 11.00"

14
WD SERIES WALL MOUNT
1. Mounting holes are designed for 3/8" hardware, 16.00" on center.
2. (Optional) For the ease of installation, mount only rear section to the wall rst.
Remove the hinge pins to detach the center swing section (see Detail A ). After
mounting rear section to the wall, reassemble center swing section and secure
it with hinge pins.
3. WD handles can be found in the hardware bag.
Rear section
Side ventilation
Front door with
keyed lock
Center swing section
19" EIA mounting rails;
2 pairs, tapped #12-24
24.00
RMU
HEIGHT
18.31 C-to-C
1", 2",3" and 4"
nominal
concentric
conduit
knockouts
1/2 -13 threaded holes
TYP (5) places
5.0
6.0
6.0
TOP/BOTTOM VIEW
FRONT VIEW WITHOUT DOOR
1", 2",3" and 4"
nominal
concentric
conduit
knockouts
(7217WS)
Provision
for
optional
2 fan
assembly
(7217WS)
Provision for optional
2 fan assembly
Draw Latch
Draw Latch
Mounting holes

15
WD SERIES WALL MOUNT
Mounting holes for
1/4" hardware
A
2.50 16.00
Mounting
holes 14",
26" and 19"
1", 2",3" and 4" nominal
concentric conduit knockouts
12.00
32.13
25.90 max. rail spacing 6
28.00 usable depth
1.75 (1 RMU)
repeating
.50
.63
.63
DETAIL A
Rear section
Rear section
support plate
Hinge pin
Nylon shoulder
washer
Lock pin
bracket
Lock pin
screw
Center swing section
REAR VIEW #12-24 Tapped EIA
mounting holes
INTERNAL SIDE VIEW
EQUIPMENT MOUNTING RAIL
DETAIL

16
15WM SERIES WALL MOUNT
1. Unscrew specialty torx screw using the supplied torx screw bit. Fig 1 (A)
2. Remove back panel from wall mount. Fig 1
3. Mount back panel to wall using 3/8" hardware, 16.00" on center.
4. Once back panel is mounted, hang main body on mounted back panel. Fig 1 (B)
5. Secure main body using torx screw (keep bit in safe place for future use).
Note: Push down tabs (Detail A ) to get one RMU mounting on the back panel.
A
A
B
15.38
17.66
18.31 TO
16.00 TO
12.25
7RMU
16.93
22.25
.625
.500
.625
1.750
PATTERN
REPEATS
12.00
TO
A
A
B
15.38
17.66
18.31 TO
16.00 TO
12.25
7RMU
16.93
22.25
.625
.500
.625
1.750
PATTERN
REPEATS
12.00
TO
A
A
B
15.38
17.66
18.31 TO
16.00 TO
12.25
7RMU
16.93
22.25
.625
.500
.625
1.750
PATTERN
REPEATS
12.00
TO
FRONT VIEW WITHOUT DOOR
FRONT VIEW WITH DOOR
18.31 C-to-C
16.00 C-to-C
12.00 C-to-C
“Spare” 1 RMU Mounting tabs
(shown extended)
Torx drive
security screws
Keyed lock
for front door
Door shown with
optional plexiglas
12.25
7 RMU
15.38
22.25
19" EIA mounting
rails; 1 pair, tapped
#10-32

17
15WM SERIES WALL MOUNT
A
A
B
15.38
17.66
18.31 TO
16.00 TO
12.25
7RMU
16.93
22.25
.625
.500
.625
1.750
PATTERN
REPEATS
12.00
TO
TOP/BOTTOM VIEW
SIDE VIEW
A
A
B
15.38
17.66
18.31 TO
16.00 TO
12.25
7RMU
16.93
22.25
.625
.500
.625
1.750
PATTERN
REPEATS
12.00
TO
5/8" Knockout
1" and 1 1/2" Conduit knockouts
1/2" and 3/4" Conduit knockouts
INTERNAL SIDE VIEW
A
A
B
15.38
17.66
18.31 TO
16.00 TO
12.25
7RMU
16.93
22.25
.625
.500
.625
1.750
PATTERN
REPEATS
12.00
TO
Usable depth from plexiglas to
back plate
Adjustable
equipment rails
A
A
B
15.38
17.66
18.31 TO
16.00 TO
12.25
7RMU
16.93
22.25
.625
.500
.625
1.750
PATTERN
REPEATS
12.00
TO
#10-32 Tapped EIA
mounting holes
1.750
Pattern
repeats
16.93
17.66
.500
.625
.625
EQUIPMENT MOUNTING
RAIL DETAIL
Provision for optional 1 fan
assembly (7217-04)

18
SECTION A-A
(FRONT PANEL NOT SHOWN)
SECTION B-B
DETAIL D
MESH PATTERN DETAIL
A A
B
B
C
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
6.05
5.75
12.0012.00
2.05
8.00
8.00
8.00
8.00
14.00
12.00
SPECIFICATIONS: WE WALL MOUNT
RACK SPACES: 19" EIA 310-E COMPLIANT - 10 RMU
COLOR: DURABLE BLACK TEXTURED POWDER COAT.
FEATURES: 2 PAIR OF FULLY ADJUSTABLE CAGE NUT (M6) MOUNTING RAILS, #12 GA.
1, 2, AND 3" CODUIT KNOCKOUTS ON TOP, BOTTOM, AND OF REAR CENTER SECTION.
SIDE MOUNTING PROVIDES FRONT/REAR ACCESS TO CABLES.
MESH FRONT AND REAR DOOR
MOUNTING HOLES
FOR 3/8" HARDWARE
TOP VIEW ISO VIEW OPENED
ISO VIEW COLLAPSED
REAR VIEW
19.45
3.00
6.05
12.0012.00
EXHAUST FAN KNOCKOUT
2x 75 CFM - 110 VAC
TYP. TOP & BOTTOM
1", 2" AND 3" NOMINAL CONCENTRIC
CONDUIT KNOCKOUT, TYP. 3 TOP &
BOTTOM, TYP. 3 REAR
3.5",
2.4",
1.4"
29.00 MAX RAIL SPACING
34.00 USABLE DEPTH
24.00
17.50 (10 RMU)
20.51
18.31TO
.
.
4.25
.16
.19 .09
.16
60°
SECTION A-A
(FRONT PANEL NOT SHOWN)
SECTION B-B
DETAIL D
MESH PATTERN DETAIL
A A
B
B
C
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
6.05
5.75
12.0012.00
2.05
8.00
8.00
8.00
8.00
14.00
12.00
SPECIFICATIONS: WE WALL MOUNT
RACK SPACES: 19" EIA 310-E COMPLIANT - 10 RMU
COLOR: DURABLE BLACK TEXTURED POWDER COAT.
FEATURES: 2 PAIR OF FULLY ADJUSTABLE CAGE NUT (M6) MOUNTING RAILS, #12 GA.
1, 2, AND 3" CODUIT KNOCKOUTS ON TOP, BOTTOM, AND OF REAR CENTER SECTION.
SIDE MOUNTING PROVIDES FRONT/REAR ACCESS TO CABLES.
MESH FRONT AND REAR DOOR
MOUNTING HOLES
FOR 3/8" HARDWARE
TOP VIEW ISO VIEW OPENED
ISO VIEW COLLAPSED
REAR VIEW
19.45
3.00
6.05
12.0012.00
EXHAUST FAN KNOCKOUT
2x 75 CFM - 110 VAC
TYP. TOP & BOTTOM
1", 2" AND 3" NOMINAL CONCENTRIC
CONDUIT KNOCKOUT, TYP. 3 TOP &
BOTTOM, TYP. 3 REAR
3.5", 2.4", 1.4"
29.00 MAX RAIL SPACING
34.00 USABLE DEPTH
24.00
17.50 (10 RMU)
20.51
18.31
TO
.
.
4.25
.16
.19 .09 .16
60°
WE SERIES WALL MOUNT
1. Mounting holes are designed for 3/8" hardware, 16.00" on center.
2. Wall Mount must be mounted to three wall studs to achieve maximum
weight capacity.
SIDE VIEW WITHOUT DOORFRONT VIEW
SECTION A-A
(FRONT PANEL NOT SHOWN)
SECTION B-B
DETAIL D
MESH PATTERN DETAIL
A A
B
B
C
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
6.05
5.75
12.0012.00
2.05
8.00
8.00
8.00
8.00
14.00
12.00
SPECIFICATIONS: WE WALL MOUNT
RACK SPACES: 19" EIA 310-E COMPLIANT - 10 RMU
COLOR: DURABLE BLACK TEXTURED POWDER COAT.
FEATURES: 2 PAIR OF FULLY ADJUSTABLE CAGE NUT (M6) MOUNTING RAILS, #12 GA.
1, 2, AND 3" CODUIT KNOCKOUTS ON TOP, BOTTOM, AND OF REAR CENTER SECTION.
SIDE MOUNTING PROVIDES FRONT/REAR ACCESS TO CABLES.
MESH FRONT AND REAR DOOR
MOUNTING HOLES
FOR 3/8" HARDWARE
TOP VIEW
ISO VIEW OPENED
ISO VIEW COLLAPSED
REAR VIEW
19.45
3.00
6.05
12.0012.00
EXHAUST FAN KNOCKOUT
2x 75 CFM - 110 VAC
TYP. TOP & BOTTOM
1", 2" AND 3" NOMINAL CONCENTRIC
CONDUIT KNOCKOUT, TYP. 3 TOP &
BOTTOM, TYP. 3 REAR
3.5", 2.4", 1.4"
29.00 MAX RAIL SPACING
34.00 USABLE DEPTH
24.00
17.50 (10 RMU)
20.51
18.31
TO
.
.
4.25
.16
.19 .09 .16
60°
1", 2" and 3" nominal
concentric conduit
knockouts
20.51
17.50 (10 RMU)
24.00
18.31 C-to-C
Provision for optional 2 fan
assembly (7217WS)
Removable front panel
with key lock
Front and rear door
with keyed lock

19
SECTION A-A
(FRONT PANEL NOT SHOWN)
SECTION B-B
DETAIL D
MESH PATTERN DETAIL
A
A
B
B
C
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
6.05
5.75
12.0012.00
2.05
8.00
8.00
8.00
8.00
14.00
12.00
SPECIFICATIONS: WE WALL MOUNT
RACK SPACES: 19" EIA 310-E COMPLIANT - 10 RMU
COLOR: DURABLE BLACK TEXTURED POWDER COAT.
FEATURES: 2 PAIR OF FULLY ADJUSTABLE CAGE NUT (M6) MOUNTING RAILS, #12 GA.
1, 2, AND 3" CODUIT KNOCKOUTS ON TOP, BOTTOM, AND OF REAR CENTER SECTION.
SIDE MOUNTING PROVIDES FRONT/REAR ACCESS TO CABLES.
MESH FRONT AND REAR DOOR
MOUNTING HOLES
FOR 3/8" HARDWARE
TOP VIEW ISO VIEW OPENED
ISO VIEW COLLAPSED
REAR VIEW
19.45
3.00
6.05
12.0012.00
EXHAUST FAN KNOCKOUT
2x 75 CFM - 110 VAC
TYP. TOP & BOTTOM
1", 2" AND 3" NOMINAL CONCENTRIC
CONDUIT KNOCKOUT, TYP. 3 TOP &
BOTTOM, TYP. 3 REAR
3.5", 2.4", 1.4"
29.00 MAX RAIL SPACING
34.00 USABLE DEPTH
24.00
17.50 (10 RMU)
20.51
18.31TO
.
.
4.25
.16
.19 .09 .16
60°
TOP/BOTTOM VIEW
REAR VIEW
SECTION A-A
(FRONT PANEL NOT SHOWN)
SECTION B-B
DETAIL D
MESH PATTERN DETAIL
A A
B
B
C
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
6.05
5.75
12.0012.00
2.05
8.00
8.00
8.00
8.00
14.00
12.00
SPECIFICATIONS: WE WALL MOUNT
RACK SPACES: 19" EIA 310-E COMPLIANT - 10 RMU
COLOR: DURABLE BLACK TEXTURED POWDER COAT.
FEATURES: 2 PAIR OF FULLY ADJUSTABLE CAGE NUT (M6) MOUNTING RAILS, #12 GA.
1, 2, AND 3" CODUIT KNOCKOUTS ON TOP, BOTTOM, AND OF REAR CENTER SECTION.
SIDE MOUNTING PROVIDES FRONT/REAR ACCESS TO CABLES.
MESH FRONT AND REAR DOOR
MOUNTING HOLES
FOR 3/8" HARDWARE
TOP VIEW ISO VIEW OPENED
ISO VIEW COLLAPSED
REAR VIEW
19.45
3.00
6.05
12.0012.00
EXHAUST FAN KNOCKOUT
2x 75 CFM - 110 VAC
TYP. TOP & BOTTOM
1", 2" AND 3" NOMINAL CONCENTRIC
CONDUIT KNOCKOUT, TYP. 3 TOP &
BOTTOM, TYP. 3 REAR
3.5",
2.4",
1.4"
29.00 MAX RAIL SPACING
34.00 USABLE DEPTH
24.00
17.50 (10 RMU)
20.51
18.31
TO
.
.
4.25
.16
.19 .09
.16
60°
SECTION A-A
(FRONT PANEL NOT SHOWN)
SECTION B-B
DETAIL D
MESH PATTERN DETAIL
A A
B
B
C
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
6.05
5.75
12.0012.00
2.05
8.00
8.00
8.00
8.00
14.00
12.00
SPECIFICATIONS: WE WALL MOUNT
RACK SPACES: 19" EIA 310-E COMPLIANT - 10 RMU
COLOR: DURABLE BLACK TEXTURED POWDER COAT.
FEATURES: 2 PAIR OF FULLY ADJUSTABLE CAGE NUT (M6) MOUNTING RAILS, #12 GA.
1, 2, AND 3" CODUIT KNOCKOUTS ON TOP, BOTTOM, AND OF REAR CENTER SECTION.
SIDE MOUNTING PROVIDES FRONT/REAR ACCESS TO CABLES.
MESH FRONT AND REAR DOOR
MOUNTING HOLES
FOR 3/8" HARDWARE
TOP VIEW ISO VIEW OPENED
ISO VIEW COLLAPSED
REAR VIEW
19.45
3.00
6.05
12.0012.00
EXHAUST FAN KNOCKOUT
2x 75 CFM - 110 VAC
TYP. TOP & BOTTOM
1", 2" AND 3" NOMINAL CONCENTRIC
CONDUIT KNOCKOUT, TYP. 3 TOP &
BOTTOM, TYP. 3 REAR
3.5",
2.4",
1.4"
29.00 MAX RAIL SPACING
34.00 USABLE DEPTH
24.00
17.50 (10 RMU)
20.51
18.31
TO
.
.
4.25
.16
.19 .09
.16
60°
SECTION A-A
(FRONT PANEL NOT SHOWN)
SECTION B-B
DETAIL D
MESH PATTERN DETAIL
A A
B
B
C
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
6.05
5.75
12.0012.00
2.05
8.00
8.00
8.00
8.00
14.00
12.00
SPECIFICATIONS: WE WALL MOUNT
RACK SPACES: 19" EIA 310-E COMPLIANT - 10 RMU
COLOR: DURABLE BLACK TEXTURED POWDER COAT.
FEATURES: 2 PAIR OF FULLY ADJUSTABLE CAGE NUT (M6) MOUNTING RAILS, #12 GA.
1, 2, AND 3" CODUIT KNOCKOUTS ON TOP, BOTTOM, AND OF REAR CENTER SECTION.
SIDE MOUNTING PROVIDES FRONT/REAR ACCESS TO CABLES.
MESH FRONT AND REAR DOOR
MOUNTING HOLES
FOR 3/8" HARDWARE
TOP VIEW ISO VIEW OPENED
ISO VIEW COLLAPSED
REAR VIEW
19.45
3.00
6.05
12.0012.00
EXHAUST FAN KNOCKOUT
2x 75 CFM - 110 VAC
TYP. TOP & BOTTOM
1", 2" AND 3" NOMINAL CONCENTRIC
CONDUIT KNOCKOUT, TYP. 3 TOP &
BOTTOM, TYP. 3 REAR
3.5", 2.4", 1.4"
29.00 MAX RAIL SPACING
34.00 USABLE DEPTH
24.00
17.50 (10 RMU)
20.51
18.31
TO
.
.
4.25
.16
.19 .09 .16
60°
INTERNAL VIEW FRONT PANEL REMOVED
WE SERIES WALL MOUNT
Mounting
holes for
3/8" hardware
1.75
Pattern
repeats
3/8" Square holes
mounting with
cage nut (M6)
12.00 12.00 6.05 3.00
19.45
4.25 12.00 12.00 6.05
12.00
14.00
5.75
8.00 8.00 8.00 8.00 2.05
34.00 Usable depth
29.00 max. rail spacing
.50 .63 .63
EQUIPMENT
MOUNTING
RAIL DETAIL
1", 2" and 3"
nominal
concentric
conduit
knockouts

20
WLP SERIES WALL MOUNT
UL60950-1
UL2416
A
B
25.00 INSIDE OPENING
12.00
10.00
17.88 INSIDE
18.31
TO
3.00TYP
(HEIGHT-2")INSIDEOPENING
16.00
16.00 TYP
24.00
1" Nominal
Conduit
Knockouts
1" Nominal
Conduit
Knockouts
2" Nominal
Conduit
Knockouts
BOTTOM VIEW
Optional
Fan
Assembly
Provisions
(7217-04)
FRONT VIEW
WITHOUT DOOR
24WLP: 1 Opening
36WLP: 2 Opening
48WLP: 3 Opening
WLPSB Stagger
Bracket Set provided
with each Wall Mount
WLPTOB
Tilt Out
Bracket Set
provided
with each
Wall Mount
TOP VIEW
SIDE VIEW
CC
Mounting
holes
designed
for 3/8"
hardware
1", 2", 3" and 4" Nominal
Concentric Conduit Knockouts
Ø 4.54 TYP
Ø 3.54 TYP
Ø 2.42 TYP
Ø 1.36 TYP
FRONT VIEW
27.00
HEIGHT
10.02
PART NO. HEIGHT WIDTH DEPTH
24WLP 24.0" 27.0" 10.0"
36WLP 36.0" 27.0" 10.0"
48WLP 48.0" 27.0" 10.0"
27.00
HEIGHT
10.02
PART NO. HEIGHT WIDTH DEPTH
24WLP 24.0" 27.0" 10.0"
36WLP 36.0" 27.0" 10.0"
48WLP 48.0" 27.0" 10.0"
Ø 1.36 TYP
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
Other manuals for WMCM Series
1
This manual suits for next models
22
Table of contents
Other Great Lakes Rack & Stand manuals

Great Lakes
Great Lakes VRX User manual

Great Lakes
Great Lakes Enhanced Rack Series User manual

Great Lakes
Great Lakes GLRR-1984 User manual

Great Lakes
Great Lakes CMR-45U16 User manual

Great Lakes
Great Lakes GL840EZ-3042 User manual

Great Lakes
Great Lakes VCMX Series User manual

Great Lakes
Great Lakes WMCM Series User manual

Great Lakes
Great Lakes SR Series User manual

Great Lakes
Great Lakes SR Series User manual

Great Lakes
Great Lakes GL24SRD User manual