Great Lakes GL24SRD User manual

19" EIA SRD Swing Rack
Installation Instructions
1-866-TRY-GLCC (879-4522)
FORM: #MS-5.02-15, REV 2
ETSI Associate Member
ISO 9001 : 2008 Registered
ISO 9000 : 2008
Thank you
for your
business!

PREFACE
This manual is provided to prevent service personnel from committing an act
that results in the risk of re, electric shock, or injury to persons. Only trained
service personnel should receive, unpack, and assemble the SRD Swing
Rack. In addition, only trained service personnel should install equipment in
enclosures.
SAFETY SYMBOLS USED IN THIS MANUAL
This manual provides general safety guidelines to be observed during
installation, operation, and maintenance of the SRD Swing Rack.
WARNING: Failure to follow directions in the warning could result in injury to
persons or loss of life.
CAUTION: Failure to follow directions in the caution could result in damage to
equipment or storage data.
SAFETY CONSIDERATIONS
WARNING: Improper handling and use of the SRD Swing Rack could result in
equipment damage, serious injury, or possible death.
Only UL® Listed ITE (Information Technology Equipment) units should be
installed inside the SRD Swing Rack.
Be sure to read and follow all individual manufacturer equipment manuals for
safety and installation instructions.
Proper spacing is required when installing electrical equipment to avoid
electrical shock.
INSTALLATION
Loading Equipment
WARNING: Only install equipment after the SRD Swing Rack has been properly
secured. Do not move the SRD Swing Rack assembly while loaded.
MAXIMUM LOAD CAPACITY: 100 pound capacity for every size of
SRD Swing Rack
2

When installing a Great Lakes Swing Rack or Wall Mount to materials such
as wood, cinder block, concrete, etc., please consider the load capacity within
the swing rack or wall mount structure, and be certain to check with local
authorities to determine the appropriate hardware requirements for these
conditions. Because wall compositions may vary at different installation
sites, Great Lakes cannot warrant the tness or suitability of any installation
instructions or installation hardware it may provide for swing rack or wall
mount enclosures. Great Lakes hereby DISCLAIMS ALL WARRANTIES,
EXPRESS AND IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE,
REGARDING THE SUFFICIENCY, FITNESS OR SUITABILITY OF ANY
INSTALLATION INSTRUCTIONS OR INSTALLATION HARDWARE GREAT
LAKES MAY PROVIDE FOR SWING RACKS AND WALL-MOUNTED
ENCLOSURES. Great Lakes recommends that an experienced maintenance
and/or technical person be consulted regarding the proper wall-mounting
hardware and procedures to be used for the anticipated load capacity of the
swing rack or wall mounted enclosure.
Product specications are subject to change without prior notice.
POWER
When using PDUs, each PDU should be connected to a committedbranch
circuit that is rated for the continuous load of all the equipment connected.
When not using a PDU, each piece of equipment should be connected to a
dedicated branch circuit.
PROTECTIVE EARTHING/GROUNDING
A main protective earthing stud is provided.
WARNING: To avoid injury to persons or loss of life, ground each SRD Swing
Rack individually to the dedicated branch circuit earthing ground
CONNECTING MAIN PROTECTIVE EARTHING STUD TO THE
DEDICATE D BRANCH CIRCUIT EARTHING GROUND CONDUCTOR
Connect the dedicated branch circuit earthing ground conductor to the main
protective earthing stud located on the support frame using a listed ring or
closed-loop terminal.
Your package should include the folowing items:
COMPONENT QTY.
BRACES (TOP & BOTTOM) 2
SWING RACK SIDE WITH SWING FRAME ATTACHED 1
SWING RACK SIDE 1
1/4 - 20 X 1/2" CARRIAGE BOLTS 8
1/4 - 20 HEX NUTS WITH SERRATED FLANGE 8
3/8" - 16 SHOULDER BOLTS 2
#10-32 X 1/2" LONG, BLACK SCREWS 50
TOOLS REQUIRED: 7/16" NUT DRIVER, PHILLIPS HEAD
SCREWDRIVER
OVERVIEW
SRD Swing Racks are designed to securely hold 19” rack mount
equipment, networking equipment, phone equipment, etc. in tight spaces
or closets
MOUNTING INSTRUCTIONS
Wood Studded Wall
Once the location on the wall has been determined, inspect the wall
surface. The wall must be at and square in the horizontal and vertical
plane to ensure the SRD Swing Rack closes correctly. If the wall is not
at and square, you might need to use shims.
Wood studded wall mounting instructions apply to a 2” x 4” wood stud
wall with ¾” plywood.
Mounting Hardware for Wood Studded Wall
GL24SRD Qty (4) 3/8 x 2” long Lag Bolts and 1” O.D. Flat Washer
GL36SRD Qty (8) 3/8 x 2” long Lag Bolts and 1” O.D. Flat Washer
GL48SRD Qty (8) 3/8 x 2” long Lag Bolts and 1” O.D. Flat Washer
Masonry Wall Surface
For a masonry wall surface, the installer must provide all the appropriate
hardware.
WARNING: Improper handling and use of the EN enclosure could result in
equipment damage, serious injury, or possible death.
3
6

STEP 1.
Attach the top and bottom brace to swing rack sides using the
1/4 - 20 x 1/2" carriage bolts and 1/4 - 20 hex nuts.
STEP 2.
Close swing frame and attach using the shoulder bolts.
STEP 3.
Mount the assembly to the wall with four lag screws (these are not pro-
vided; The installer is to determine correct hardware for the type of wall).
Mounting holes are designed for 3/8" hardwares, 16" on center.
ASSEMBLY INSTRUCTIONS
4
PART NO. H W D RMU
GL24SRD 24.12" 20.62" 24.00" 12
GL36SRD 36.37" 20.62" 24.00" 19
GL48SRD 49.62" 20.62" 24.00" 26
SPECIFICATIONS
Certications: UL Listed
Construction: Body: 12 gauage steels; Rails: 12 gauage steel
Finish: Black Powder Coat
Grounding: Studs located on mounting channel
Rail Type: #10-32 UNF Tapped
Total Maximum Load Capacity: 100 lbs. for all sizes
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
DWG NO: REV
SHEET: OF
DRAWN
CHECKED & APP.
TITLE
DRAWING NOT TO SCALE
PART NUMBER:
QTY PER UNIT: 1
MATERIAL TYPE:
MATERIAL GAUGE:
FINISH:
GREAT LAKES CASE & CABINET CO., INC.
P.O. BOX 551 EDINBORO, PA 16412
PHONE (814) 734-7303 FAX (814) 734-3907
E-MAIL glcc@greatcabinets.com
Use of this document is subject to
a confidentiality and nondisclosure
agreement with Great Lakes Case
& Cabinet Co., Inc. (GLCC) and may
not be reproduced, disclosed or
utilized in whole or in part without
prior written authorization from GLCC.
NOTICE:
TOLERANCE UNLESS OTHERWISE NOTED:
ANGULAR +/- 1
.XXXX +/- .010
.XXX +/- .015
.XX +/- .030
.X FOR REF. ONLY
UNLESS OTHERWISE SPECIFIED
ALL DIMENSIONS ARE IN INCHES
DIMENSIONAL LIMITS APPLY
AFTER APPLICATION OF FINISH
INTERPRET DRAWING PER ASME Y14.5M-1994
THIRD ANGLE
PROJECTION
DATE
DATE 1 1
0
MZ 1/11/2011
WSS 1/11/2011I013250
-
-
SEE NOTES
SWING RACKS - DEEP
FRONT VIEW
TOP VIEW
RIGHT SIDE VIEW
DETAIL A
TYP, WALL MOUNTING SLOTS
RACK PIVOTS FROM EITHER SIDE
A
24.0"
"H"- HEIGHT
20.8
24.0"
20.63
11.63
.625
.625
1.750(1RMU)
"RMU"TOTAL
18.313
PROVISIONS FOR OPTIONAL
CM-01 - CABLE CINCH STRAPS
PART NUMBER RMU TOTAL H - HEIGHT
24SRD3200 12 23.97
36SRD320019 36.22
48SRD3200 26 48.47
SPECIFICATIONS:
RACK SPACES : 19" EIA 310-E COMPLIANT - SEE CHART
WEIGHT CAPACITY: 100 LBS - EVENLY DISTRIBUTED.
FINISH: DURABLE TEXTURED BLACK POWDER COATING.
CERTIFICATIONS: UL 60950-1 STANDARD FOR I.T. & COMMUNICATIONS EQ.
CONSTRUCTION: #12 GA. C.R.S. MOUNTING CHANNELS & SUPPORT FRAME.
USABLE DEPTH: 22" FROM MOUNTING SURFACE
HARDWARE: PACKAGE OF QTY-50; #12-24 SCREWS INCLUDED.
16.00 STUD CENTERS
1.250
#12-24 UNC, TAPPED HOLES FOR
EQUIPMENT MOUNTING
3.0
3.5
.562
.250
Receiving, Unpacking, and Removing the SRD Swing Rack
Inspect and report damage before receiving. Unpack the SRD Swing
Rack by carefully removing the corrugated cartons and corners. Avoid
damaging the SRD Swing Rack when removing packaging.
WARNING: Only trained service personnel should be used to remove
the SRD Swing Rack from the carton. Also, be sure you have a sufcient
number of service personnel. Do not attempt to mount the SRD Swing
Rack by yourself.
5
Provisions for Optional
CM-01 - Cable Cinch
Straps
#10-32 UNF Tapped
Holes for Equipment
Mounting
form # MS-5.02-14
1/4-20 Hex Nuts w/Serrated
Flanges (QTY. 8)
1/4-20 x 1/2" Lg. Carriage
Bolts (QTY. 8)
Socket Head Shoulder Bolts
with 3/8"- 16 Thread (QTY. 4)
Swing Frame Ships
Partially Assembled
M6 x 12mm Copper Ground
Studs, (1) On Swing Frame
and (2) on Swing Rack Side
Socket Head Shoulder Bolts
with 3/8" - 16 Thread (QTY.4)
Nylon Shoulder Washer
Swing Rack Side
Top/Bottom Brace (QTY. 2)

STEP 1.
Attach the top and bottom brace to swing rack sides using the
1/4 - 20 x 1/2" carriage bolts and 1/4 - 20 hex nuts.
STEP 2.
Close swing frame and attach using the shoulder bolts.
STEP 3.
Mount the assembly to the wall with four lag screws (these are not pro-
vided; The installer is to determine correct hardware for the type of wall).
Mounting holes are designed for 3/8" hardwares, 16" on center.
ASSEMBLY INSTRUCTIONS
4
PART NO. H W D RMU
GL24SRD 24.12" 20.62" 24.00" 12
GL36SRD 36.37" 20.62" 24.00" 19
GL48SRD 49.62" 20.62" 24.00" 26
SPECIFICATIONS
Certications: UL Listed
Construction: Body: 12 gauage steels; Rails: 12 gauage steel
Finish: Black Powder Coat
Grounding: Studs located on mounting channel
Rail Type: #10-32 UNF Tapped
Total Maximum Load Capacity: 100 lbs. for all sizes
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
DWG NO: REV
SHEET: OF
DRAWN
CHECKED & APP.
TITLE
DRAWING NOT TO SCALE
PART NUMBER:
QTY PER UNIT: 1
MATERIAL TYPE:
MATERIAL GAUGE:
FINISH:
GREAT LAKES CASE & CABINET CO., INC.
P.O. BOX 551 EDINBORO, PA 16412
PHONE (814) 734-7303 FAX (814) 734-3907
E-MAIL glcc@greatcabinets.com
Use of this document is subject to
a confidentiality and nondisclosure
agreement with Great Lakes Case
& Cabinet Co., Inc. (GLCC) and may
not be reproduced, disclosed or
utilized in whole or in part without
prior written authorization from GLCC.
NOTICE:
TOLERANCE UNLESS OTHERWISE NOTED:
ANGULAR +/- 1
.XXXX +/- .010
.XXX +/- .015
.XX +/- .030
.X FOR REF. ONLY
UNLESS OTHERWISE SPECIFIED
ALL DIMENSIONS ARE IN INCHES
DIMENSIONAL LIMITS APPLY
AFTER APPLICATION OF FINISH
INTERPRET DRAWING PER ASME Y14.5M-1994
THIRD ANGLE
PROJECTION
DATE
DATE 1 1
0
MZ 1/11/2011
WSS 1/11/2011I013250
-
-
SEE NOTES
SWING RACKS - DEEP
FRONT VIEW
TOP VIEW
RIGHT SIDE VIEW
DETAIL A
TYP, WALL MOUNTING SLOTS
RACK PIVOTS FROM EITHER SIDE
A
24.0"
"H"- HEIGHT
20.8
24.0"
20.63
11.63
.625
.625
1.750(1RMU)
"RMU"TOTAL
18.313
PROVISIONS FOR OPTIONAL
CM-01 - CABLE CINCH STRAPS
PART NUMBER RMU TOTAL H - HEIGHT
24SRD3200 12 23.97
36SRD320019 36.22
48SRD3200 26 48.47
SPECIFICATIONS:
RACK SPACES : 19" EIA 310-E COMPLIANT - SEE CHART
WEIGHT CAPACITY: 100 LBS - EVENLY DISTRIBUTED.
FINISH: DURABLE TEXTURED BLACK POWDER COATING.
CERTIFICATIONS: UL 60950-1 STANDARD FOR I.T. & COMMUNICATIONS EQ.
CONSTRUCTION: #12 GA. C.R.S. MOUNTING CHANNELS & SUPPORT FRAME.
USABLE DEPTH: 22" FROM MOUNTING SURFACE
HARDWARE: PACKAGE OF QTY-50; #12-24 SCREWS INCLUDED.
16.00 STUD CENTERS
1.250
#12-24 UNC, TAPPED HOLES FOR
EQUIPMENT MOUNTING
3.0
3.5
.562
.250
Receiving, Unpacking, and Removing the SRD Swing Rack
Inspect and report damage before receiving. Unpack the SRD Swing
Rack by carefully removing the corrugated cartons and corners. Avoid
damaging the SRD Swing Rack when removing packaging.
WARNING: Only trained service personnel should be used to remove
the SRD Swing Rack from the carton. Also, be sure you have a sufcient
number of service personnel. Do not attempt to mount the SRD Swing
Rack by yourself.
5
Provisions for Optional
CM-01 - Cable Cinch
Straps
#10-32 UNF Tapped
Holes for Equipment
Mounting
form # MS-5.02-14
1/4-20 Hex Nuts w/Serrated
Flanges (QTY. 8)
1/4-20 x 1/2" Lg. Carriage
Bolts (QTY. 8)
Socket Head Shoulder Bolts
with 3/8"- 16 Thread (QTY. 4)
Swing Frame Ships
Partially Assembled
M6 x 12mm Copper Ground
Studs, (1) On Swing Frame
and (2) on Swing Rack Side
Socket Head Shoulder Bolts
with 3/8" - 16 Thread (QTY.4)
Nylon Shoulder Washer
Swing Rack Side
Top/Bottom Brace (QTY. 2)

When installing a Great Lakes Swing Rack or Wall Mount to materials such
as wood, cinder block, concrete, etc., please consider the load capacity within
the swing rack or wall mount structure, and be certain to check with local
authorities to determine the appropriate hardware requirements for these
conditions. Because wall compositions may vary at different installation
sites, Great Lakes cannot warrant the tness or suitability of any installation
instructions or installation hardware it may provide for swing rack or wall
mount enclosures. Great Lakes hereby DISCLAIMS ALL WARRANTIES,
EXPRESS AND IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE,
REGARDING THE SUFFICIENCY, FITNESS OR SUITABILITY OF ANY
INSTALLATION INSTRUCTIONS OR INSTALLATION HARDWARE GREAT
LAKES MAY PROVIDE FOR SWING RACKS AND WALL-MOUNTED
ENCLOSURES. Great Lakes recommends that an experienced maintenance
and/or technical person be consulted regarding the proper wall-mounting
hardware and procedures to be used for the anticipated load capacity of the
swing rack or wall mounted enclosure.
Product specications are subject to change without prior notice.
POWER
When using PDUs, each PDU should be connected to a committedbranch
circuit that is rated for the continuous load of all the equipment connected.
When not using a PDU, each piece of equipment should be connected to a
dedicated branch circuit.
PROTECTIVE EARTHING/GROUNDING
A main protective earthing stud is provided.
WARNING: To avoid injury to persons or loss of life, ground each SRD Swing
Rack individually to the dedicated branch circuit earthing ground
CONNECTING MAIN PROTECTIVE EARTHING STUD TO THE
DEDICATE D BRANCH CIRCUIT EARTHING GROUND CONDUCTOR
Connect the dedicated branch circuit earthing ground conductor to the main
protective earthing stud located on the support frame using a listed ring or
closed-loop terminal.
Your package should include the folowing items:
COMPONENT QTY.
BRACES (TOP & BOTTOM) 2
SWING RACK SIDE WITH SWING FRAME ATTACHED 1
SWING RACK SIDE 1
1/4 - 20 X 1/2" CARRIAGE BOLTS 8
1/4 - 20 HEX NUTS WITH SERRATED FLANGE 8
3/8" - 16 SHOULDER BOLTS 2
#10-32 X 1/2" LONG, BLACK SCREWS 50
TOOLS REQUIRED: 7/16" NUT DRIVER, PHILLIPS HEAD
SCREWDRIVER
OVERVIEW
SRD Swing Racks are designed to securely hold 19” rack mount
equipment, networking equipment, phone equipment, etc. in tight spaces
or closets
MOUNTING INSTRUCTIONS
Wood Studded Wall
Once the location on the wall has been determined, inspect the wall
surface. The wall must be at and square in the horizontal and vertical
plane to ensure the SRD Swing Rack closes correctly. If the wall is not
at and square, you might need to use shims.
Wood studded wall mounting instructions apply to a 2” x 4” wood stud
wall with ¾” plywood.
Mounting Hardware for Wood Studded Wall
GL24SRD Qty (4) 3/8 x 2” long Lag Bolts and 1” O.D. Flat Washer
GL36SRD Qty (8) 3/8 x 2” long Lag Bolts and 1” O.D. Flat Washer
GL48SRD Qty (8) 3/8 x 2” long Lag Bolts and 1” O.D. Flat Washer
Masonry Wall Surface
For a masonry wall surface, the installer must provide all the appropriate
hardware.
WARNING: Improper handling and use of the EN enclosure could result in
equipment damage, serious injury, or possible death.
3
6

PREFACE
This manual is provided to prevent service personnel from committing an act
that results in the risk of re, electric shock, or injury to persons. Only trained
service personnel should receive, unpack, and assemble the SRD Swing
Rack. In addition, only trained service personnel should install equipment in
enclosures.
SAFETY SYMBOLS USED IN THIS MANUAL
This manual provides general safety guidelines to be observed during
installation, operation, and maintenance of the SRD Swing Rack.
WARNING: Failure to follow directions in the warning could result in injury to
persons or loss of life.
CAUTION: Failure to follow directions in the caution could result in damage to
equipment or storage data.
SAFETY CONSIDERATIONS
WARNING: Improper handling and use of the SRD Swing Rack could result in
equipment damage, serious injury, or possible death.
Only UL® Listed ITE (Information Technology Equipment) units should be
installed inside the SRD Swing Rack.
Be sure to read and follow all individual manufacturer equipment manuals for
safety and installation instructions.
Proper spacing is required when installing electrical equipment to avoid
electrical shock.
INSTALLATION
Loading Equipment
WARNING: Only install equipment after the SRD Swing Rack has been properly
secured. Do not move the SRD Swing Rack assembly while loaded.
MAXIMUM LOAD CAPACITY: 100 pound capacity for every size of
SRD Swing Rack
2

19" EIA SRD Swing Rack
Installation Instructions
1-866-TRY-GLCC (879-4522)
FORM: #MS-5.02-15, REV 2
ETSI Associate Member
ISO 9001 : 2008 Registered
ISO 9000 : 2008
Thank you
for your
business!
This manual suits for next models
2
Table of contents
Other Great Lakes Rack & Stand manuals

Great Lakes
Great Lakes GL840EZ-3042 User manual

Great Lakes
Great Lakes UL60950-1 User manual

Great Lakes
Great Lakes CMR-45U16 User manual

Great Lakes
Great Lakes GLRR-1984 User manual

Great Lakes
Great Lakes SR Series User manual

Great Lakes
Great Lakes VCMX Series User manual

Great Lakes
Great Lakes SR Series User manual

Great Lakes
Great Lakes Enhanced Rack Series User manual

Great Lakes
Great Lakes WR Series User manual

Great Lakes
Great Lakes VRX Highlander User manual