PROPERTIES
WIRING DIAGRAM
Connect the module according to the diagram above, and then add the Z-Wave
module to CLU controller. To do this, follow these steps:
1. Press the “Link” button located on the CLU module (green LED blinks in 200 ms intervals).
2. Press the button located on the added Z-Wave module.
If the module was added correctly, it will be signalled by three blinks of green and red LEDs
on the CLU. After physically pairing the module with CLU, perform system conguration.
In order to do so, follow these steps:
1. Connect the CLU module using the ETHERNET port to the computer on which
the GRENTON OBJECT MANAGER conguration program is installed.
2. Open a new project or create a new one in GRENTON OBJECT MANAGER program.
3. Run the CLU DISCOVERY procedure.
4. Add found modules to the project.
MODULE INSTALLATION
•enables you to connect four 230 V inputs
•inputs are fully congurable
•small size – ts into a P60 box under the ancillary equipment
•each input can carry out up to seven independent functions
•each function can request up to four events simultaneously
•operates with 230 V supply
•communicates with other wireless modules using a mesh network
GRENTON DIGITAL IN Z-Wave
INP-038-Z-04
WIRELESS DIGITAL INPUT MODULE
FOR FLUSH-MOUNT ASSEMBLY
Wireless digital input module
for ush-mount assembly
allows you to connect any
input with the system.
CONFIGURATION PARAMETERS
CHARACTERISTICS
NAME DESCRIPTION
Value Returns input mode as 0 or 1
Inertion Minimum interval in milliseconds which has to pass between presses of
a button so that it is interpreted as a new pressing task
HoldDelay Time in milliseconds after which, when pressing
and holding a button, the OnHold event occurs
HoldInterval Cyclical interval in milliseconds after which, when pressing
and holding a button, the OnHold event occurs
METHODS
NAME DESCRIPTION
SetInertion Sets Inertion value
SetHoldDelay Sets HoldDelay value
SetHoldInterval Sets HoldInterval value
EVENTS
NAME DESCRIPTION
TECHNICAL SPECIFICATIONS
OnChange Occurs when a change in the input state takes place (regardless of the value)
OnSwitchOn Occurs when the high state is set at input
OnSwitchO Occurs when the low state is set at input
OnShortPress Occurs after pressing the button for 500 - 2000 ms
OnLongPress Occurs after pressing the button for two seconds
OnHold Occurs for the rst time after HoldDelay time passes
and then cyclically every HoldInterval Value
OnClick Occurs after pressing the button for less than 500 ms
AC supply 230 V
average current input 2 mA
max. current input 3 mA
Z-Wave frequency 868 MHz
weight 27 g
dimensions (H/W/D) 19/45/36 mm
max. connection wire section ≤ 1.5 mm2
operating temperature range O to +40°C
~230 V L
N
v. 1.1