V509990 R1 1 IP 16
1000 CP Printed in Japan
ANALOG INPUT UNIT
ANALOG INPUT BOX
-ML8
ANALOG INPUT UNIT
-AD8
ANALOG INPUT UNIT
-ML4AD4
Owner’s Manual
E

2
FCC INFORMATION (U.S.A.)
1. IMPORTANT NOTICE: DO NOT MODIFY THIS UNIT! This product, when installed as indicated in the instructions contained in this manual, meets FCC
requirements. Modifications not expressly approved by Yamaha may void your authority, granted by the FCC, to use the product.
2. IMPORTANT: When connecting this product to accessories and/or another product use only high quality shielded cables. Cable/s supplied with this product MUST
be used. Follow all installation instructions. Failure to follow instructions could void your FCC authorization to use this product in the USA.
3. NOTE: This product has been tested and found to comply with the requirements listed in FCC Regulations, Part 15 for Class “B” digital devices. Compliance with
these requirements provides a reasonable level of assurance that your use of this product in a residential environment will not result in harmful interference with
other electronic devices. This equipment generates/uses radio frequencies and, if not installed and used according to the instructions found in the users manual, may
cause interference harmful to the operation of other electronic devices. Compliance with FCC regulations does not guarantee that interference will not occur in all
installations. If this product is found to be the source of interference, which can be determined by turning the unit “OFF” and “ON”, please try to eliminate the
problem by using one of the following measures: Relocate either this product or the device that is being affected by the interference. Utilize power outlets that are on
different branch (circuit breaker or fuse) circuits or install AC line filter/s. In the case of radio or TV interference, relocate/reorient the antenna. If the antenna lead-in
is 300 ohm ribbon lead, change the lead-in to coaxial type cable. If these corrective measures do not produce satisfactory results, please contact the local retailer
authorized to distribute this type of product. If you can not locate the appropriate retailer, please contact Yamaha Corporation of America, Electronic Service
Division, 6600 Orangethorpe Ave, Buena Park, CA 90620
The above statements apply ONLY to those products distributed by Yamaha Corporation of America or its subsidiaries.
WARNING: THIS APPARATUS MUST BE EARTHED
IMPORTANT
THE WIRES IN THIS MAINS LEAD ARE COLOURED IN
ACCORDANCE WITH THE FOLLOWING CODE:
GREEN-AND-YELLOW : EARTH
BLUE : NEUTRAL
BROWN : LIVE
As the colours of the wires in the mains lead of this apparatus may
not correspond with the coloured markings identifying the terminals in
your plug, proceed as follows:
The wire which is coloured GREEN and YELLOW must be
connected to the terminal in the plug which is marked by the letter E
or by the safety earth symbol or coloured GREEN and YELLOW.
The wire which is coloured BLUE must be connected to the terminal
which is marked with the letter N or coloured BLACK.
The wire which is coloured BROWN must be connected to the
terminal which is marked with the letter L or coloured RED.
* This applies only to products distributed by YAMAHA KEMBLE
MUSIC (U.K.) LTD.

3
■
Precautions
• Do not place a container with liquid or small metal
objects on top of this unit. Liquid or metal objects
inside this unit are a fire and electrical shock hazard.
• Do not allow water to enter this unit or allow the unit
to become wet. Fire or electrical shock may result.
• Connect this unit’s power cord only to an AC outlet of
the type stated in this Owner’s Manual or as marked
on the unit. Failure to do so is a fire and electrical
shock hazard.
• Do not scratch, bend, twist, pull, or heat the power
cord. A damaged power cord is a fire and electrical
shock hazard.
• Do not place heavy objects, including this unit, on top
of the power cord. A damaged power cord is a fire and
electrical shock hazard. In particular, be careful not to
place heavy objects on a power cord covered by a car-
pet.
• If you notice any abnormality, such as smoke, odor, or
noise, or if a foreign object or liquid gets inside the
unit, turn it off immediately. Remove the power cord
from the AC outlet. Consult your dealer for repair.
Using the unit in this condition is a fire and electrical
shock hazard.
• Should this unit/AC adapter/power supply be
dropped or the cabinet be damaged, turn the power
switch off, remove the power plug from the AC outlet,
and contact your dealer. If you continue using the unit
without heeding this instruction, fire or electrical
shock may result.
• If the power cord is damaged (i.e., cut or a bare wire is
exposed), ask your dealer for a replacement. Using the
unit with a damaged power cord is a fire and electrical
shock hazard.
• Do not remove the unit’s cover. You could receive an
electrical shock. If you think internal inspection,
maintenance, or repair is necessary, contact your
dealer.
• Do not modify the unit. Doing so is a fire and electri-
cal shock hazard.
• When rack-mounting the unit, allow enough free
space around the unit for normal ventilation. This
should be: 10 cm at the sides, 15 cm behind, and 30
cm above.
• For normal ventilation during use, remove the rear of
the rack or open a ventilation hole.
• If the airflow is not adequate, the unit will heat up
inside and may cause a fire.
• This unit has ventilation holes at the top, bottom, and
rear to prevent the internal temperature rising too
high. Do not block them. Blocked ventilation holes
are a fire hazard.
• Hold the power cord plug when disconnecting it from
an AC outlet. Never pull the cord. A damaged power
cord is a potential fire and electrical shock hazard.
• Do not touch the power plug with wet hands. Doing
so is a potential electrical shock hazard.
• The digital circuits of this unit may induce a slight
noise into nearby radios and TVs. If noise occurs,
relocate the affected equipment.
• XLR-type connectors are wired as follows: pin 1:
ground, pin 2: hot (+), and pin 3: cold (–).
Rack Mounting Caution
If the unit is rack mounted and transported regularly,
for example, when on a tour, we recommend that the
rear of the unit be supported by fitting a pair metal
brackets, one each side. The following drawing pro-
vides the information necessary to make such brack-
ets.
Note that only one bracket is shown here and the
bracket for the other side must be bent in the opposite
direction.
86.5
20.5
3.1
4- ø6.5
2-R2
R2
2-R2
R5
t = 1.6
(82.1)
76.2
44.45
31.75
5.9
0
36.5
14.5
7.5
8
0
12
134
200
0

4
Cards installable on the AI8 analog input box:
•
LMY2-ML
: MIC/LINE input card
•
LMY4-AD
: AD card
Up to eight cards can be installed.
Analog input unit models:
•
AI-8-ML8
: AI8 analog input box that has eight
LMY2-ML cards installed
•
AI8-AD8
: AI8 analog input box that has eight
LMY4-AD cards installed
•
AI8-ML4AD4
:AI8 analog input box that has four
LMY2-ML cards and four LMY4-AD
cards installed
■
Front panel
■
Rear panel
Thank you for choosing the AI8 analog input box, or the AI8-ML8/AI8-AD8/AI8-ML4AD4 analog input
unit, specifically designed for the Yamaha PM1D digital audio mixing system.
The AI8 inputs signals to the DSP unit DSP1D/DSP1D-EX engine (controlled via the CS1D control sur-
face). Up to ten AI8s can be connected to each DSP1D/DSP1D-EX.
Be sure to ask an authorizedYamaha service engineer to install the card and set up the unit.
Never perform installation and setup by yourself.
UNIT NO.
PHANTOM MASTER
ON
OFF +48V
POWER
ON/ OFF
12345678
ANALOGINPUT BOX
1
2
3
INPUT UNIT ID
PHANTOM MASTER
ON
OFF +48V
POWER
ON/ OFF
ANALOG INPUT BOX
The illustration shows the AI8
analog input box.
*
75Ω
IN
CB A
OUTPUT
ON
OFF
OUT
A
B
C
CONTROL
PORT
WORD
CLOCK
75Ω
IN
CB A
OUTPUT
ON
OFF
OUT
A
B
C
CONTROL
PORT
WORD
CLOCK
5
4
6
7

5
A
INPUT UNIT ID indicator
This indicator displays the ID number of the INPUT
connector of the DSP unit DSP1D/DSP1D-EX con-
nected to the AI8. If an error occurs in the connection
to the DSP1D, or if the unit does not lock to the word-
clock signal, one of the following error indications
appears.
Error message
E1
: The AI8 is connected to the OUTPUT connector
of the DSP1D/DSP1D-EX. Connect the AI8 to the
INPUT connector.
E3
: A cable is disconnected from the OUTPUT A, B,
or C connector on the rear panel, or the connec-
tion is made incorrectly. If the connection is
proper, replace the cable.
UL
: The unit does not lock to the wordclock signal.
UC
: The control signal is not being received correctly.
“
.
x
.
”:(two dots and the ID number of the OUTPUT
connector on the DSP1D/DSP1D-EX)
Illuminating or flashing dots mean that the AI8 is
connected in Mirror mode from the DSP1D/
DSP1D-EX.
If “
.
x
.
”lights up continuously during Mirror
mode operation, the CONTROL PORT switch
(
4
) setting matches the setting controlled from
the CS1D and the system is operating normally.
If the control signal from the CS1D has changed
the setting during Mirror mode operation and it
does not match the CONTROL INPUT PORT
switch (
4
) setting any more, this indicator
changes in the following order.
“”means that the control signal from the
CS1D has changed the setting to “A.”
“”means that the control signal from the
CS1D has changed the setting to “B.”
During this time period, you can connect or dis-
connect the cable from the unselected output
connector.
If you set the CONTROL PORT switch so that it
matches the setting made via the control signal
from the CS1D, “
.
x
.
”lights up continuously.
B
PHANTOM MASTER switch, indicator
This switch is used to turn the phantom power on and
off to all the headphone amplifiers of the input con-
nectors (for which the phantom power is switched on)
on the AI8 that has the LMY2-ML analog input card
equipped with the headphone amplifier. When you
turn on the switch, the indicator on the left of the
switch lights up.
C
POWER ON/OFF
Use this switch to turn the power to the AI8 on and
off. When the power is turned on, the INPUT UNIT
ID indicator lights up.
D
CONTROL PORT switch
This switch enables you to select a port used to con-
trol the AI8 via the DSP unit DSP1D/DSP1D-EX.
Select from OUTPUT A, B, and C to receive the con-
trol signal for switching between channels A and B on
the LMY2-ML analog input card, or turning the
phantom power on and off.
During Mirror mode operation, the control signal
sent from the CS1D has priority, and the CONTROL
PORT switch is disabled. In this case, the INPUT
UNIT ID indicator shows the status. For more infor-
mation, refer to
1
INPUT UNIT ID indicator.
E
OUTPUT connectors A, B, C
These connectors are used to output multi-channel
digital audio signals. The same signal is routed to all
three connectors. Be sure to use the included genuine
Yamaha half-pitch 68-pin cable for connection.
Optional genuine Yamaha cables in a variety of
lengths are also available.
F
WORD CLOCK IN jack, ON/OFF switch
The WORD CLOCK IN jack is used to provide the
word clock to the AI8 from a connected external
device or a clock generator. Use a BNC cable with an
impedance of 75
Ω
for connection.
The WORD CLOCK ON/OFF switch is used to termi-
nate the word clock connection. Basically, if the AI8 is
the last device of the word clock chain, or if nothing is
connected to the WORD CLOCK IN/OUT jacks, set
this switch to ON.
G
WORD CLOCK OUT jack
The WORD CLOCK OUT jack is used to provide
word clock from the AI8 to the connected external
device, such as a clock generator, digital MTR, and
DAT recorder. Use a BNC cable with an impedance of
75
Ω
for connection.
“. .”
“.x.” “. .”
“ ”( or“”)

6
■
Specifications
Digital I/Os
Slots
Sampling frequency (external sync) 39.69 kHz –50.88 kHz
Power supply USA and Canada : 120 V, 60 Hz
Others : 230 V, 50 Hz
Power consumption 120 W
Dimensions (W
×
H
×
D) 480 mm
×
141.5
mm
×
466.8 mm
Weight 15.4 kg
Operating temperature 10 –35˚C
Power cable length 2.1 m
Cooling fan speed always fixed
Accessories Connection cable (68-pin, D-sub, half-pitch) x 1, Length: 3m
I/O connectors Level Type
OUTPUT A, B, C RS-422 D-sub, half-pitch, 68-pin connector (female)
WORD CLOCK IN TTL/75
Ω
(ON/OFF) BNC Connector
WORD CLOCK OUT TTL/75
Ω
BNC Connector
Card Input
LMY2-ML Channel 1A or 1B, 2A or 2B
LMY4-AD Channel 1 –4

7
■
Dimensions
•Specifications and appearance are subject to change without notice for improvement.
•For European Model
Purchaser/User information specified in EN55103-1 and EN55103-2.
Inrush Current: 22A
Conformed Environment: E1, E2, E3 and E4.
455
466.8
480
430
132(3U)
UNIT NO.
PHANTOM MASTER
ON
OFF +48V
POWER
ON/ OFF
123456 7 8
141.5
ANALOG INPUT BOX
9.5
unit: mm

YAMAHA CORPORATION
Pro Audio & Digital Musical Instrument Division
P.O. Box 3, Hamamatsu, 430-8651, Japan

ANALOG INPUT UNIT
ANALOG INPUT BOX
-ML8
ANALOG INPUT UNIT
-AD8
ANALOG INPUT UNIT
-ML4AD4
取扱説明書
J

2
!
安全上のご注意 ―安全にお使いいただくため―
安全にお使いいただくため、ご使用の前にこの「安全上のご注意」をよくお読みください。
またお読みになったあと、いつでも見られるところに必ず保存してください。
絵表示 この取扱説明書および製品への表示では、製品を安全に
正しくお使いいただき、あなたや他の人々への危害や財産への
損害を未然に防止するために、いろいろな絵表示をしています。
内容をよく理解してから本文をお読みください。
絵表示の例
:注意(危険・警告を含む)を促す事項
:決しておこなってはいけない禁止事項
プラグをコンセン
ト
から抜け
:必ずおこなっていただく強制事項
設置されるとき
●この機器はAC100V専用です。それ以外の電源
(AC200V、船舶の直流電源など)では使用しな
いでください。火災・感電の原因となります。
●この機器に水が入ったり、機器がぬれたりし
ないようご注意ください。火災・感電の原因
となります。雨天・降雪時や海岸・水辺での
使用はとくにご注意ください。
●電源コードの上に重い物をのせないでくださ
い。コードに傷が付くと、火災・感電の原因
となります。とくに、敷物などで覆われた
コードに気付かずに重い物を載せたり、コー
ドが本機の下敷きになることのないよう、十
分にご注意ください。
ご使用になるとき
●この機器の上に水などの入った容器や小さな
金属物を置かないでください。こぼれたり、
中に入ったりすると、火災・感電の原因にな
ります。
●電源コードを傷つけたり、加工したり、無理
に曲げたり、ねじったり、引っ張ったり、加
熱したりしないでください。コードが破損し
て、火災・感電の原因になります。
●この機器の裏ぶたやカバーは絶対に外さない
でください。感電の原因になります。
内部の点検・整備・修理が必要と思われると
きは、販売店にご依頼ください。
●この機器を改造しないでください。火災・感
電の原因となります。
●雷が鳴りだしたら、早めに機器本体の電源ス
イッチを切り、電源プラグをコンセントから
抜いてください。
●落雷のおそれがあるとき、電源プラグが接続
されたままならば、電源プラグには触れない
でください。感電の原因となります。
使用中に異常が発生したとき
●断線・芯線の露出など、電源コードが傷んだ
ら、販売店に交換をご依頼ください。そのま
まで使用すると、火災・感電の原因となりま
す。
●万一、この機器を落としたり、キャビネット
を破損した場合は、電源スイッチを切り電源
プラグをコンセントから抜いて販売店にご連
絡ください。そのまま使用すると、火災・感
電の原因となります。
●煙が出る、変なにおいや音がするなどの異常
がみとめられたときや、内部に水などの異物
が入った場合は、すぐに電源スイッチを切
り、電源プラグをコンセントから抜いてくだ
さい。そのあと、販売店にご連絡ください。
異常状態のままで使用すると、火災・感電の
原因となります。
この欄に記載されている事項を無視して、誤った取扱いをすると、人が死亡または重傷を負う
可能性があります。
警告
分解禁止
プラグをコンセン
ト
から抜け
プラグをコンセン
ト
から抜け
接触禁止
プラグをコンセン
ト
から抜け

3
●オーディオラックなどに入れるときは、放熱
をよくするために、壁や他の機器との間に隙
間をとってください。隙間の大きさは、側面
では10cm、背面では15cm、天面では30cm以
上必要です。
さらにラックの背面を開放するか、もしくはラッ
クの背面に相当の通風孔を開けてください。
放熱が不十分だと内部に熱がこもり、火災の
原因となることがあります。
設置されるとき
●電源プラグを抜くときは、電源コードを引っ
張らず、必ずプラグを持ってください。コー
ドを引っ張ると、電源コードが傷ついて、火
災・感電の原因となることがあります。
●濡れた手で電源プラグを抜き差ししないでく
ださい。感電の原因となることがあります。
●この機器の通風孔をふさがないでください。
内部の温度上昇を防ぐため、この機器のケー
スの後、上、底部には通風孔があけてありま
す。通風孔がふさがると内部に熱がこもり、
火災の原因となることがあります。
とくに次のような使い方は避けてください。
・ 機器をあお向けや横倒し、逆さまにする。
・ 本箱や押し入れなど、専用ラック以外の風
通しの悪い狭いところに押し込める。
・ テーブルクロスを掛けたり、じゅうたんや
布団の上に置いて使用する。
この欄に記載されている事項を無視して、誤った取扱いをすると、人が傷害を負ったり、物的
損害が発生したりする可能性があります。
注意
!
使用上のご注意 ―正しくお使いいただくため―
コネクターの極性について
◆ XLRタイプコネクターのピン配列は次のとおりです。
1:シールド(GND)、2:ホット(+)、3:コールド(−)
これは、IEC60268規格に基づいています。
他の電気機器への影響について
◆ この機器のデジタル回路から発生するわずかな雑音が、近
くのラジオやテレビに入る可能性があります。そのような
ときは、両者を少し離してください。
ラックマウント時のご注意
ツアーなどでラックマウントしたまま頻繁に運搬される場
合には図のような金具を製作して本機のリア部を支えてく
ださい。
尚、本図は片側の金具の形状を示したものですので本図と
対称形状のものを同時に製作ください。
86.5
20.5
3.1
4- ø6.5
2-R2
R2
2-R2
R5
t = 1.6
(82.1)
76.2
44.45
31.75
5.9
0
36.5
14.5
7.5
8
0
12
134
200
0
孔

4
この度はヤマハデジタルオーディオミキシングシステムPM1D専用アナログインプットボックスA I 8、アナログ
インプットユニットAI8-ML8/AI8-AD8/AI8-ML4AD4をお買い上げいただきありがとうございます。
AI8はコントロールサーフェスCS1Dでコントロールするエンジン、DSPユニットDSP1D/DSP1D-EXに信号を入力し
ます。DSP1D/DSP1D-EX、1台につき最大10台のAI8が接続可能です。カードの装着、ユニットの設置などは
ヤマハサービスエンジニアにご依頼ください。決してお客様ご自身で行なわないでください。
アナログインプットボックスA I 8 に装 着 可 能 なカード:
・LMY2-ML―マイク/ラインインプットカード
・LMY4-AD―ADカード
最大8枚のカードをマウントできます。
アナログインプットユニットモデ ル:
・AI8-ML8― LMY2-ML8枚がアナログインプットボックスAI8に装着
されたユニット
・AI8-AD8― LMY4-AD8枚がアナログインプットボックスAI8に装着
されたユニット
・AI8-ML4AD4― LMY2-ML4枚+LMY4-AD4枚がアナログ
インプットボックスAI8に装着されたユニット
■フロントパネル
INPUT UNIT ID
PHANTOM MASTER
ON
OFF
+48V
POWER
ON/ OFF
12345678
ANALOGINPUT BOX
1
2
3
INPUT UNIT ID
PHANTOM MASTER
ON
OFF
+48V
POWER
ON/ OFF
ANALOG INPUT BOX
※イラストはアナログインプット
ボックスAI8です。
■リアパネル
75Ω
IN
CB A
OUTPUT
ON
OFF
OUT
A
B
C
CONTROL
PORT
WORD
CLOCK
75Ω
IN
CB A
OUTPUT
ON
OFF
OUT
A
B
C
CONTROL
PORT
WORD
CLOCK
5
4
6
7

5
1INPUT UNIT ID インジケーター
AI8に接続されているDSPユニットDSP1D/DSP1D-
EXのINPUT端子番号を表示します。
DSP1Dとの接続にエラーがあるときやワードクロック
がロックしていないなどの場合はエラー表示で知ら
せます。
エラー表示
E1:AI8がDSP1D/DSP1D-EXのOUTPUT端子に接
続されています。INPUT端子に接続してくださ
い。
E3:リアパネルのOUTPUTA、B、C端子に接続され
ているケーブルがはずれている、あるいは接続
先が間違っています。接続が正しい場合は、
ケーブルを交換してみてください。
UL:ワードクロックがロックしていない。
UC:コントロール信号が正しく受信されていない。
.x.(ドット点灯、x=DSP1D/DSP1D-EXのINPUT端
子番号)
インジケーター内のドットの点灯はAI8がDSP1D/
DSP1D-EXからミラーモード接続されていること
を表わします。
ミラーモード動作時インジケーターが.x.の表
示のまま点灯しているときは、CONTROL
PORTスイッチ(4)の設定とCS1Dからコント
ロールされる設定が一致していて、システムが
正常に動作していることを示します。
ミラーモード動作でCS1Dからのコントロール 信
号によって強制的に設定が変更されたために
CONTROLINPUTPORTスイッチ(4)の設定
と異なっている場合、インジケーターは
“. .”
“.x.” “. .”
“”(
または
“”)
と繰り返し、表示されます。
の表示はCS1Dからのコントロール信号
によって設定がAに強制的に切り替わっている
ことを表わします。
また はCS1Dからのコントロール信号に
よって設定がBに強制的に切り替わっているこ
とを表わします。
この間、選択されていない一方の出力端子は
ケーブルの抜き差しが可能です。
また、CONTROLPORTスイッチの設定をCS1D
からのコントロール信号による強制設定に合わ
せるとインジケーターの表示は.x.が点灯し
たままとなります。
2PHANTOM MASTER スイッチ、インジケーター
ヘッドアンプ付きのアナログ入力カードLMY2-MLが
搭載されたAI8で、ファンタム電 源が オンに 設 定され
ている入力端子のヘッドアンプのファンタム電源をま
とめてオン/オフするマスタースイッチです。スイッチ
をオンにすると、スイッチ左のインジケーターが点灯し
ます。
3POWER ON/OFF
AI8の電源スイッチです。電源がオンのときにINPUT
UNITIDインジケーターが点灯します。
4CONTROL PORT スイッチ
DSPユニットDSP1D/DSP1D-EXからAI8をコントロール
するときに使用する端子をOUTPUTA〜C端子のい
ずれか1 つから選択します。アナログ入力カード
LMY2-MLのチャンネルA/B切り換えやファンタム電源
オン/オフなどをコントロールする信号はこの
CONTROLPORTスイッチで選択したOUTPUTA〜
C端子のいずれか1つの端子より受信します。
ミラーモード動作時はCS1Dからのコントロール信号に
よる設定が優先され、CONTROLPORTスイッチは働
きません。その場合、INPUTUNITIDインジケーター
にその状態が表示されます。詳しくは①INPUTUNIT
IDインジケーターをお読みください。
5OUTPUT A、B、C 端子
マルチチャンネルのデジタルオーディオ信号を出力
するための端子です。A、B、Cの各端子には同じ信
号が出力されます。接続には、同梱のヤマハ純正
ハーフピッチ68ピンケーブルのみをご使用ください。
各種長さのヤマハ純正ケーブルがオプションとして
用意されています。
6WORD CLOCK IN 端子、ON/OFF スイッチ
WORDCLOCKIN端子は、クロックジェネレーターや
外部機器からAI8にワードクロックを供給するための
端子です。接続には、インピーダンス75ΩのBNCケー
ブルをご使用ください。
WORDCLOCKON/OFFスイッチは、ワードクロック
接続の終端処理を行うためのスイッチです。原則とし
て、AI8がワードクロック接続の終端となる場合、およ
びWORDCLOCKIN/OUT端子に何も接続しない
場合はONに設定します。
7WORD CLOCK OUT 端子
AI8からデジタルMTR、DATレコーダーなどの外部
機器にワードクロックを供給する端子です。接続に
は、インピーダンス75ΩのBNCケーブルをご使用くだ
さい。

6
■仕様
サンプリング周波数(外部同期) 39.69kHz〜50.88kHz
電源 100V,50/60Hz
消費電力 AI8: 20W
AI8-ML8: 95W
AI8-AD8: 75W
AI8-ML4AD4: 80W
外形寸法(W×H×D) 480mm×141.5mm×466.8mm
重量 15.4kg
動作環境 10〜35℃
電源コード長 2.1m
冷 却ファンスピード 常時固定
同梱付属品 接続ケーブル(68pinD-subHalfPitch)×1本、長さ:3 m
デジタル入出力仕様
入出力端子 レベル コネクター
OUTPUTA,B,C RS-422 D-subハーフピッチ68ピンコネクター(メス)
WORDCLOCKIN TTL/75Ω(ON/OFF) BNCコネクター
WORDCLOCKOUT TTL/75ΩBNCコネクター
スロット
カード Input
LMY2-ML チャンネル1Aor1B,2Aor2B
LMY4-AD チャンネル1〜4

7
■寸法図
455
466.8
480
430
132(3U)
UNIT NO.
PHANTOM MASTER
ON
OFF
+48V
POWER
ON/ OFF
123456 7 8
141.5
ANALOG INPUT BOX
9.5
単位:mm
・ 仕様および外観は改良のため予告なく変更することがあります。
・高調波ガイドライン適合品

PA・DMI事業部PE営業部☎053-460-2455
〒430-8650浜松市中沢町10-1
●お客様ご相談窓口:PA製品に対するお問合せ窓口
ヤマハ・プロオーディオ・インフォメーションセンター
Tel:03-5791-7678 Fax:03-5488-5085(電話受付=祝祭日を除く月〜金/11:00〜19:00)
E-mail:[email protected]
●営業窓口
PA・DMI事業部PE営業部 ☎011-512-6106 〒064-8543 札幌市中央区南十条西1-1-50 ヤマハセンター内
☎022-222-6214 〒980-0804 仙台市青葉区大町2-2-10 住友生命青葉通りビル
☎03-5488-5480 〒108-8568 東京都港区高輪2丁目17-11
☎052-232-5744 〒460-8588 名古屋市中区錦1-18-28
☎06-6647-8359 〒556-0011 大阪市浪速区難波中1-13-17 なんば辻本ニッセイビル
☎092-412-5556 〒812-8508 福岡市博多区博多駅前2-11-4
☎053-460-2455 〒430-8650 浜松市中沢町10-1
●ヤマハ電気音響製品サービス拠点:修理受付および修理品お預かり窓口
北海道
サービスステーション
☎011-512-6108 〒064-8543 札幌市中央区南十条西1-1-50 ヤマハセンター内
仙 台
サービスステーション
☎022-236-0249 〒984-0015 仙台市若林区卸町5-7 仙台卸商共同配送センター3F
首都圏サービスセンター ☎044-434-3100 〒211-0025 川崎市中原区木月1184
浜 松
サービスステーション
☎053-465-6711 〒435-0016 浜松市和田町200 ヤマハ(株)和田工場6号館2階
名古屋サービスセンター ☎052-652-2230 〒454-0058 名古屋市中川区玉川町2-1-2 ヤマハ(株)名古屋流通センター3F
大 阪サービスセンター ☎06-6877-5262 〒565-0803 吹田市新芦屋下1-16 ヤマハ(株)千里丘センター内
四 国
サービスステーション
☎087-822-3045 〒760-0029 高松市丸亀町8-7 (株)ヤマハミュージック神戸 高松店内
広 島
サービスステーション
☎082-874-3787 〒731-0113 広島市安佐南区西原6-14-14
九 州
サービスステーション
☎092-472-2134 〒812-8508 福岡市博多区博多駅前2-11-4
本 社/CSセンター ☎053-465-1158 〒435-0016 浜松市和田町200 ヤマハ(株)和田工場6号館2階
※ 所在地・電話番号などは変更されることがあります。
※ 2001年1月現在
■保証書
この商品には保証書がついています。販売店でお渡ししてい
ますから、ご住所・お名前・お買上げ年月日・販売店名など所定
事項の記入および記載内容をおたしかめのうえ、大切に保管し
てください。
保証書は当社がお客様に保証期間内の無償サービスをお約
束するもので、この商品の保証期間はお買上げ日より1年です。
保証期間内の転居や、ご贈答用に購入された場合などで、記
載事項の変更が必要なときは、事前・事後を問わずお買上げ販
売店かお客様ご相談窓口、またはヤマハ電気音響製品サービス
拠点へご連絡ください。継続してサービスできるように手配いた
します。
■損害に対する責任
この商品(搭載プログラムを含む)の使用または使用不能に
より、お客様に生じた損害(事業利益の損失、事業の中断、事業
情報の損失、その他の特別損失や逸失利益)については、当社は
一切その責任を負わないものとします。また、如何なる場合でも、
当社が負担する損害賠償額は、お客様がお支払になったこの商
品の代価相当額をもって、その上限とします。
サービスについて
■調整・故障の修理
「故障かな?」と思われる症状のときは、この説明書をもう一度
よくお読みになり、電源・接続・操作などをおたしかめください。そ
れでもなお改善されないときには、お買上げ販売店へご連絡く
ださい。調整・修理いたします。
調整・修理にさいしては保証書をご用意ください。保証規定に
より、調整・修理サービスをいたします。また、故障した製品をお
持ちいただくか、サービスにお伺いするのかも保証書に書かれ
ています。
修理サービスは保証期間が過ぎた後も引き続きおこなわれ、
そのための補修用性能部品が用意されています。性能部品とは
製品の機能を維持するために不可欠な部品のことをいい、PA製
品ではその最低保有期間は製造打切後8年です。この期間は通
商産業省の指導によるものです。
■お客様ご相談窓口
ヤマハPA製品にかんするご質問・ご相談は下記のお客様ご
相談窓口へ、アフターサービスについてのお問合わせはヤマハ
電気音響製品サービス拠点へおよせください。
PA北海道営業所
P A 仙台営業所
P A 東京事業所
PA名古屋営業所
P A 大阪事業所
P A 九州営業所
本社国内営業一課
Other manuals for AI8
1
This manual suits for next models
5
Table of contents
Other Yamaha I/O System manuals
Popular I/O System manuals by other brands

ICP DAS USA
ICP DAS USA IR-712-MTCP quick start

Velleman
Velleman VMB6IN manual

Siemens
Siemens FDCI181-2 product manual

Rockwell Automation
Rockwell Automation Allen-Bradley B Series installation instructions

Siemens
Siemens Simatic ET 200S 2/4AI RTD ST manual

National Instruments
National Instruments NI USB-6008 user guide

HORNER
HORNER SmartBlock HE579DIQ880 Specification & installation guide

Puls
Puls MiniLine-2 ML60.241 manual

bolid
bolid S2000-AR2 Operation manual

AMR
AMR LS-3030 Installation and setup instructions

Panasonic
Panasonic FZ-VCN40 Series operating instructions

Extron electronics
Extron electronics ISS 506 Series installation guide