Grosvenor GT8 User manual

Version 1.6 March 2022
Disclaimer
Copyright 2022, Grosvenor Technology Ltd. All rights reserved.
All brands, names, or trademarks appearing in this document are acknowledged as the
trademarks of their respective owners.
No part of this document may be reproduced in any form or by any means for any purpose without
the written permission of Grosvenor Technology.
Whilst we make every effort to ensure the accuracy of our publications, Grosvenor Technology
assumes no responsibility or liability for any errors or inaccuracies that my appear in this
document.
GT8 Terminal
User Guide

Page i
Preface
About the terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
Battery Life . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
Installation Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
WEEE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
About the GT8 terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
About this Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
Related Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
Europe, Middle East and Africa . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
North America . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
Hardware specification
Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Processor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Operating System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Input/Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Facial recognition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Temperature Screening module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
Contents

Page ii
Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
Internal Persistent Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
Host Connectivity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
Operating Temperature & Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
Plug and Play . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
Integration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
Sound . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
Camera . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
Physical Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
Sustainability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
Reader modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Comms modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7
Biometric module. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7
Installation
Fitting the terminal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
Cable routing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
Fitting GT8 to wall bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
Contents

Page iii
Face recognition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
Face recognition installation considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
Enrolment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
Supporting Information and FAQs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
Power options
AC 110-240V via adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
DC 12V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
Power over Ethernet PoE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
Battery backup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2
Installing optional modules
Front plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
Reader module options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2
Fitting internal fingerprint reader module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3
Fitting Swipe Reader Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4
Fitting the Wi-Fi module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6
GT8 IO Relay boards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-7
The EM-IO-RLY-B Relay board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-8
The EM-IO-ER-B Relay board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-12
Temperature screening . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-16
About the Temperature Screening module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-16
Temperature Screening module performance specifications . . . . . . . . . . . . . . . . . . . . . . . . . . 5-18
System start-up
Terminal setup navigation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1
Contents

Page iv
Terminal shut down
Software reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2
Recovery menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2
Terminal setup
Accessing the terminal setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-1
Configuring network settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-2
Configure wired networks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-3
Configuring readers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-4
Wiegan Bitmask . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-5
Parity mask . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-5
Testing card readers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-6
Testing the camera . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-6
Testing Biometric reader. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-7
Terminal health information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-8
Software deployment
Deployment from USB memory device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-1
Application setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-2
Care and maintenance
Maintenance instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-2
Contents

Chapter 1:
Preface

Page 1-2
Preface
Important Note:
Menus and options will vary depending on the hardware options supplied and software version
installed. Please refer to additional instructions supplied with your terminal for additional
information.

Page 1-3
Preface
About the terminal
The GT series of data collection terminals has been designed for various applications including
Time and Attendance in both the commercial and retail sectors, where low cost, flexibility and
ease of installation are essential factors.
The terminal incorporates a flexible, modular hardware design which supports different reader
technologies such as biometric, proximity, barcode and magnetic as well as enabling power
supplies and ancillary input/output modules to be easily added.
The GT series of terminals run an advanced Android operating system offering unsurpassed
functionality with flexibility giving a rich user experience for data collection solutions.
The ability to manage the software after deployment is incorporated as a fundamental function of
the system. Everything from a complete operating system flash image update to a change in
application program parameters can be downloaded over the Internet or uploaded via USB
memory stick.

Page 1-4
Preface
Certifications
The GT8 has been certified for use in the following markets:
Europe CE Certification
USA FCC, UL 62368-1
In addition, the terminal has been certified to comply with the requirements of the CB certification
authority which may meet compliance requirements in their member countries. For further
information regarding CB certification please see www.iecee.org/dyn/www/f?p=106:40:0, or
discuss with Grosvenor Technology’s professional services team.
If the GT8 is intended to be used in countries other than those listed above, please contact
Grosvenor Technology’s professional services team to discuss how we can assist with
certification.
Battery Life
The GT8 terminal is fitted with a Lithium-Ion battery which typically has a service life of between
two-three years. In order to ensure the continued reliable operation of the back-up battery function
we recommend regularly checking the condition of the battery and replacing it when it has reached
the end of its service life.
The GT8 is also fitted with a button cell type battery on the main PCB to maintain the real-time
clock (RTC) of the device when power is removed. This battery typically has a service life of
around 10 years. The battery should only be replaced by suitably qualified engineers and care
should be taken to avoid damage to the PCB caused by ESD (ElectroStatic Discharge).
Replacement batteries must be of the same type as the original, and the old battery should be
disposed of in accordance with local regulations.
Care should be taken when recycling the terminal to ensure that the batteries are removed and
recycled in accordance with local regulations/legislation.
Maintenance
The GT8 terminaldoes not require any regular maintenance during its service life.
It is however recommended that periodically, once every six months, the condition of the battery
should be checked to see if there are signs that it’s reaching the end of its life. Occasionally, the
battery may start to swell towards the end of its life, if this is noticed, the battery should be replaced
(Part Number: EM-BB-2HR-A).

Page 1-5
Preface
Cleaning
Cleaning of the outside of the terminal can be undertaken at intervals appropriate to the
environment that it is being used and the frequency of use. In all cases it is recommended that the
surface of the terminal is wiped with a lint free cloth that has been dampened with up to 70%
isopropyl alcohol. We do not recommend spraying liquids directly onto the surface of the terminal
as this could potentially cause damage to the electronics. Particular care should be taken when
cleaning the display and biometric devices to prevent damage.
Installation Safety
The GT8 terminal should be installed in accordance with the instructions documented in this User
Guide. The terminal should be installed in compliance with any Health and Safety legislation and
it is recommended that any electrical or network connections to the terminal are undertaken by a
suitably qualified engineer.
The GT8 terminal is designed to be installed indoors only with a normal ambient operating
temperature between 0-35 °C (32-95 °F).
Care should be taken when installing the terminal to ensure that it does not present any possible
hazards to people or property within its vicinity. The terminal should be installed at a height that
ensures compliance with any local disability legislation.
WEEE
In accordance with EN 50419, the terminal must be disposed at the end of its life by returning to
a designated recycling organisation for waste electrical and electronic equipment as defined
within the WEEE directive. The terminal must not be disposed of in normal domestic waste.
Batteries should be carefully removed from the terminal prior to disposal taking care to prevent
short-circuits, crushing or damage to the battery housing.

Page 1-6
Preface
About the GT8 terminal
GT8 is more than just a next generation time and attendance terminal - it’s designed to open up
a world of possibilities for wider integration with Human Resources Management Systems
(HRMS) and a myriad of potential new applications beyond workforce management.
About this Guide
This User Guide is intended for users who will be responsible for installing and configuring the
GT8 terminal.
This Guide was written with the following firmware, application and optional modules installed:
Firmware: v2.0.0
Application: GTEasyClock v2.0.0
RM-SP-SFSLIM-GT8A Fingerprint Reader
RM-HID-B Prox/card reader
CM-WIFI-M2-22 Wi-Fi module
Related Documents
You should also refer to the following documents, available from Grosvenor Technology:
GT API Reference Manual. This document is targeted at software developers writing
Android applications for the GT8 terminal.
Application User Guide. Relevant to your application.
Technical Support
Technical Support can be obtained from Grosvenor Technology from the following points of
contact:
Europe, Middle East and Africa
Phone: +44 (0)1202 627611
E-mail: [email protected]
Website: www.grosvenortechnology.com
North America
Phone: +1 800.989.5197
E-mail: [email protected]
Website: www.gtclocks.com

Chapter 2:
Hardware specification

Page 2-1
Hardware specification
Terminals
Front Panel Assembly - Black FP-GT8-BL
Front Panel Assembly - White FP-GT8-WH
Display
8 inch full colour capacitive multi-touch display with toughened glass for use in high traffic
environments
16:10 aspect ratio, 1280 x 800 pixel resolution
A separate glass inlay, below the display, provides the capability to customise the terminal
with backlit corporate branding
Processor
1.6GHz Quad Core
Operating System
Android 10.0
Input/Output
4 User Accessible + 2 Internal USB 2.0 ports
Facial recognition
A choice of optional input/output accessories are available, including:
Suprema SFM Slim
Expanded fingerprint database of 10,000+ using fast matching on terminal algorithm
Contactless smart card readers: Mifare, iClass SE, Feig and Multi-tech readers
Proximity card reader: supports a range of readers, including HID Prox 125kHz
Magnetic stripe card reader
Barcode reader or external scanner: multi-format, Visible and IR
I/O relay modules

Page 2-2
Hardware specification
Temperature Screening module
Modules
Temperature Screening module EM-TM-X
Temperature Module Mounting Kit - GT8 EM-TM-KIT-B
Expansion modules
IO Relay Module EM-IO-RLY-B
IO External Reader Relay Module EM-IO-ER-B
Memory
3GB
Internal Persistent Storage
16GB high performance flash storage
Host Connectivity
Ethernet: 10/100/1000MHz
Wi-Fi: Intel dual band, dual stream 802.11ac (optional)
Bluetooth (optional)
Power
12VDC ±5%
Power over Ethernet Plus (POE+) 802.3at
Internal lithium ion battery, up to 2 hours backup
Operating Temperature & Humidity
0°C - 35°C (32ºF to 95ºF)
5-90% Non-condensing

Page 2-3
Hardware specification
Plug and Play
Fast easy installation
Easy to fit reader modules and peripherals
VESA mount fixings
Integration
Supports native Android and HTML 5 Apps
Software Development Kit available
Sound
Integrated stereo speakers
Integrated microphone
Camera
5 Megapixel with front illumination; supports photo and video
Physical Security
Metal wall-mount bracket with optional security fixing
Optical tamper detection
Dimensions
216mm (H) x 206mm (W) x 78mm (D)
8.5 inches (H) x 8.1 inches (W) x 3.8 inches (D)
Weight: 1.5Kg (3.3Lbs)
Sustainability
7-year design life
Minimal footprint with industry-leading aesthetics

Page 2-4
Hardware specification
The GT8 terminal can be customised by fitting a range of optional modules
Reader modules
Barcode Reader Module Infra Red RM-BAR-B
Barcode Reader Module Visible RM-BARV-B
Feig Fixed Code Reader Module RM-FEIG-FC-B
Feig HiTag Reader Module RM-FEIG-HI-B
HID 125kHz Reader Module RM-HID-B
HID iClass SE Reader Module (incl. Mifare) RM-ICLSE-B
Extended Fingerprint Capacity Module RM-IDENT-10K
Lumidigm Reader Module RM-LUM-M320-GT8
Magnetic Reader Module RM-MAG-B
Suprema SFSlim Fingerprint Reader Module RM-SP-SFSLIM-GT8A
Camera
SF Slim Bio
Module with illumination
Swipe Reader Module
Mag, Barcode Visible
& IR
Customisable Inlay
Configurable back
lighting
Subject Illumination
Visible and IR lighting Touch Screen
Prox Reader Module
Or custom logo with illumination

Page 2-5
Hardware specification
125KHz Reader Module RM-HID-B
iClass SE Reader Module RM-ICLSE-B
Elatec MultiTech Reader Module RM-ELATEC-B
Feig HI Reader Module RM-FEIG-HI-B
Feig FC Reader Module RM-FEIG-FC-B
Barcode Visible Red Reader Module RM-BARV-B
Barcode Infra Red Reader Module RM-BAR-B
Magnetic Stripe Reader Module RM-MAG-B
RFIdeas MultiTech Reader Module RM-RFID-B

Page 2-6
Hardware specification
JP4 Socket. Supports WiFi extension modules
Reset button. Initiates hardware reset, terminal will reboot. Accessible via hole in back
cover (using straightened paper clip or similar)
RTC Backup. Real Time Clock Backup Battery maintains time during power
disconnection, 10 year life
Micro USB Connector. Debug/ADB port
Swipe Reader Module Connector. Reader modules include:
Mag Swipe
Barcode Swipe
RECOVERY button. To access the on-screen options menu for functions including
Factory Reset
Bio module location. SF Slim.
JP4 Socket
Accessory Mounting
Camera Module
Battery Connector
Reset Button
Ethernet Connector
USB Connector USB
Connector
Recovery button
BIO Module Location
RTC Backup Battery
Micro USB Connector
Swipe Reader
Module Connector
Battery
Location
Dotted line
Stereo Speakers
One each side
Power IN
Connector
(2.1mm)

Page 2-7
Hardware specification
Battery connector. For connection of the GTL Li-Ion Battery Pack
EM-BB-2HR-A
Provides up to 2 hour runtime
Battery backup may be used with all power options including PoE
Note: units are shipped with battery disconnected. Please connect battery before first use
(tuck wires into space at side of battery to avoid obscuring Power IN Connector
WARNING: only fit battery pack specified, failure to observe may result in fire hazard
Battery location. Dotted line.
Power IN Connector (2.1mm). 12V DC External PSU (centre positive) 12 V + 5% with
minimum 2A capacity (refer to Power Loading for current calculation)
Ethernet Connector. 10/100/1000baseT Full duplex, auto crossover, supports PoE+
USB Connector. USB2 x 4, for connecting external I/O devices
USB Connector. USB2 x 2, for connecting internal modules
Comms modules
WiFi Comms Module CM-WIFI-M2-22
Biometric module
Suprema SF Slim Reader Module RM-SP-SFSLIM-GT8A

Chapter 3:
Installation
Table of contents
Other Grosvenor Touch Terminal manuals