4. Battery Performance
Testing Conditions: Ambient Temperature: 25±5℃; Huminity:45%~85%.
Normal charge: Charge battery under CC(0.2C)/CV(57.6V) mode until over charge protection or the
charge current reduce to 0.02C, and then rest for 0.5h.
5. BMS function
This battery pack have Battery Management System (BMS), which can monitor the system operation state,
provide over discharge, overcharge, over current, short circuit, over temperature, low temperature protection. And
the BMS support communication between battery packs, and connect to external equipment.
System alarm and protection parameter
After Normal charge,discharge @0.2C current to the end
Of discharge voltage. Repeat above process until
discharge capacity reduce to 80% of initial value.
0.5h, then discharge @0.2C current to 3.1V. Repeat
above process until discharge capacity reduce to 80% of
initial value.
Discharge
temperature
characteristic@
0.33C
Capacity @specified temperature
Capacity @ 25℃
After normal charge, store the battery @25±5℃for two
months., then discharge capacity @0.2C,the retention
capacity accord with criterion.
Over-charge warning for each cell
Over-charge protection for each cell
Over-charge release for each cell