2.0
Installing
the
HLP
4200
Platform
The following sections provide the information neces-
sary to install the HLP 4200. Please read
all
the instruc-
tions before beginning installation.
2.1ReceivingandInspection
As you unpack your unit, inspect the shipping container
and equipmentfordamage. Save the shippingmaterialfor
future use.
If the container or
the
equipment is damaged, notify both
the freight carrier and Harmonic Lightwaves (800/730-
4099).
To
protectthe operatorfrom potentialinjury,and to
protectthe equipmentfromfurtherdamage,donotperform
any operational tests.
2.2 Mountingthe Unit in theRack
The HLP 4200 occupies three rack unit spaces in an
EIA
standard
19
inch rack. To mount the unitin the rack:
1.Mark the exact position
in
the rack where
you want
to
install the unit.
2.
Prepare the four mounting screws and #2
Phillips screwdriver.
3. Position the unit
in
the rack, align the holes
in the mounting brackets with thethreaded
holes
in
the rack upright, and secure the four
mounting screws through the chassis ears.
2.3PowerRequirements
The HLP 4200 accepts power supply modules that
generate 24 VDC for the internal bus.
For
standard
100-
240 VAC,
50/60
Hz input the CPS 4200 module is
used.
It is possible to power the HLP 4200 platform with the
CPS 4000 power supply. However,the CPS 4000 may
not provide sufficient current to drive the newest
modules available from Harmonic Lightwaves. Please
consult a Harmonicrepresentative before using
a
CPS
4000 supply in an
HLP
4200 platform.
The
unit
can have backup power by an external 24 VDC
source. This input is only protected by
a
fuse, and it is
the customer’s responsibility to keep this voltage below
+
28 V and havesurge and spike protection, otherwise
the plug-in units may be damaged.
2.3.1
Connecting an External
24
VDC Power
Source
Connect the external 24 VDC power source to the
barrier strip connector located on the rear of the HLP
4200
according to Figure 4. Switch the external supply
off prior to makingthe connection and observe the
correct polarity. Use number 14
AWG
wire. Refer to
Figure 4.
WARNING:
To avoid
personal
injury
and equipment
damage,
switch
off
power
from
the
DC
source
prior
to
installation.
Never
handle
“live”
wiring.
2.3.2
DC
FuseReplacement
The HLP 4200 uses one fuse at the 24 VDC input to
protect the external power supply. To replace the fuse,
turn offthe power source and use
a
flat blade screw-
driver to release the screws that fasten the fuse panel
assembly
to
the Platform. Remove fuse panel assembly
and replace with
a
fuse of the same type and rating;
specifically, 125V, 15
A,
5
x 20 mm, FAST.
2.4InstallingtheRS-485, RS 232 andAlarm
Cables
2.4.1 RS-232CableInstallation
The RS-232 serial port interfaces between the
NETWatch Element Management System computer and
the HLP4200 Platform. To install the RS-232 cable,
connect
a
9
pin cable from COM PORT
1
on the
NETWatch computer to the RS-232 serial port on the
Platformrear panel. Refer to Figure 4 for location.
The cable should be less than
50
feet long. It the
NETWatch computer is located more than
50
feet from
the transceiver, use
a
line extender.
2.4.2RS-485CableInstallation
The RS-485 ports on the Platform are used for connect-
ing tothe NETWatch Element Management System.
Connect the
W11
cable from the RS-485 OUT port on
the transceiver to theRS-485 IN port
of
any Harmonic
Lightwavesproduct that supports the RS-485 interface.
You can connect other units in
a
series by using the RS
-
485 IN and OUT ports located on
all
Harmonic
Lightwavesequipment. Refer
to
Figure 4.
6