8. A 1/8 N.P.T. plugged tapping, accessible for test gage connection, must be installed immediately upstream of the gas
supply connection to the appliance.
9. The furnace must NOT be operated without a leak limiting orifice installed in the unit pressure regulator vent, if
applicable.
10. The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of ½ PSIG.
11. The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during
any pressure testing of the gas supply piping system at test pressures equal to or less than ½ PSIG.
NOTE: CHECK ALL GAS CONNECTIONS FOR LEAKS. A SOAP SOLUTION SHOULD BE USED FOR THIS
PURPOSE. NEVER USE A TORCH OR FLAME OF ANY KIND.
TABLE IV
Unit BTU/Hr. Input
per Heater
Total BTU/Hr.
Input
Total BTU/Hr.*
Output
(IH) (ISH) (H) RHFA, RMUA, RHVA – 100 100,000 100,000 76,000 (80,000)
(IH) (ISH) (H) RHFA, RMUA, RHVA – 125 125,000 125,000 95,000 (100,000)
(IH) (ISH) (H) RHFA, RMUA, RHVA – 160 160,000 160,000 121,600 (128,000)
(IH) (ISH) (H) RHFA, RMUA, RHVA – 210 210,000 210,000 159,600 (168,000)
(IH) (ISH) (H) RHFA, RMUA, RHVA – 250 250,000 250,000 190,000 (200,000)
(IH) (ISH) (H) RHFA, RMUA, RHVA – 300 300,000 300,000 228,000 (240,000)
(IH) (ISH) (H) RHFA, RMUA, RHVA – 400 400,000 400,000 304,000 (320,000)
(IH) (ISH) (H) RHFA, RMUA, RHVA – 600 300,000 600,000 456,000 (480,000)
(IH) (ISH) (H) RHFA, RMUA, RHVA – 800 400,000 800,000 608,000 (640,000)
(IH) (ISH) (H) RHFB, RMUB, RHVB – 200 100,000 200,000 152,000 (160,000)
(IH) (ISH) (H) RHFB, RMUB, RHVB – 250 125,000 250,000 190,000 (200,000)
(IH) (ISH) (H) RHFB, RMUB, RHVB – 320 160,000 320,000 243,200 (296,000)
(IH) (ISH) (H) RHFB, RMUB, RHVB – 420 210,000 420,000 319,200 (336.000)
(IH) (ISH) (H) RHFB, RMUB, RHVB – 500 250,000 500,000 380,000 (400,000)
(IH) (ISH) (H) RHFB, RMUB, RHVB – 600 300,000 600,000 456,000 (480,000)
(IH) (ISH) (H) RHFB, RMUB, RHVB – 800 400,000 800,000 608,000 (640,000)
(IH) (ISH) (H) RHFB, RMUB, RHVB – 1000 250,000 1,000,000 760,000 (800,000)
(IH) (ISH) (H) RHFB, RMUB, RHVB – 1200 300,000 1,200,000 912,000 (960,000)
(IH) (ISH) (H) RHFB, RMUB, RHVB – 1600 400,000 1,600,000 1,216,000 (1,280,000)
Honeywell Modusnap Valve
Model Size: 400
Temperature Settings of Controls
(Modusnap Valve, TL and DC)
(TL) SET THIS CONTROL TO 110 DEGREES, THERE IS NO OTHER SETTING ADJUSTMENT.
(This control is to protect the modusnap valve bulb from exceeding 120 degrees.)
(DC) SET THIS CONTROL TO 2 TO 3 DEGREES ABOVE MODUSNAP VALVE SETTING.
(MODUSNAP VALVE) SET THIS CONTROL 2 TO 3 DEGREES ABOVE ROOM THERMOSTAT SET POINT.
(This is to allow for temperature loss through duct work and room loss.)
MODUSNAP VALVE SETTINGS
Dial # 1 2 3 4 5 6 7 8 9
Degrees 60 65 70 75 80 85 90 95 100
(ROOM THERMOSTAT) SET AT ANY TEMPERATURE OCCUPANT WANTS, JUST SO LONG AS THE MODUSNAP
VALVE IS SET PROPERLY.
* All IH, ISH and H series units are 80% efficient