Heat & Glo LifeStyle Collection • Twilight-II • 2087-900 Rev. G • 12/054
B. Glass Specifications
Hearth& HomeTechnologiesappliancesmanufacturedwith
tempered glass may be installed in hazardous locations
such as bathtub enclosures as defined by the Consumer
Product Safety Commission (CPSC). The tempered glass
has been tested and certified to the requirements of ANSI
Z97.1andCPSC 16 CFR 1202 (SafetyGlazingCertification
Council SGCC# 1595 and1597.ArchitecturalTesting, Inc.
Reports02-31919.01 and 02-31917.01).
Thisstatement is in compliance withCPSC 16CFRSection
1201.5“Certificationandlabelingrequirements” whichrefers
to 15 U.S. Code (USC) 2063 stating “…Such certificate
shallaccompanythe product or shall otherwise be furnished
toanydistributororretailertowhomtheproduct isdelivered.”
Somelocal buildingcodesrequiretheuseoftemperedglass
with permanent marking in such locations. Glass meeting
thisrequirement is available from the factory.Please contact
yourdealer ordistributor toorder.
A. Appliance Certification
NOTE: This installation must conform with local codes. In the
absence of local codes you must comply with the National
Fuel Gas Code, ANSI Z223.1-latest edition in the U.S.A.
and the CAN/CGA B149 Installation Codes in Canada.
NOTINTENDED FOR USEASAPRIMARYHEATSOURCE.
This appliance is tested and approved as either supplemen-
tal room heat or a decorative appliance. It should not be fac-
tored as primary heat in residential heating calculations.
Listing and Code Approvals
F. HighAltitude Installations
U.L.Listedgasappliances are tested and approvedwithout
requiring changes for elevations from 0 to 2000 feet in the
U.S.A.and Canada.
When installing this appliance at an elevation above 2000
feet, it may be necessary to decrease the input rating by
changingthe existingburner orificeto asmaller size.Input
rate should be reduced by 4% for each 1000 feet above a
2000 foot elevation in the U.S.A., or 10% for elevations
between2000and4500feetinCanada. If the heating value
of the gas has been reduced, these rules do not apply. To
identify the proper orifice size, check with local gas utility.
If installing this appliance at an elevation above 4500 feet
(in Canada), check with local authorities.
E. BTU Specifications
1
MODEL: Twilight-II
LABORATORY: Underwriters Laboratories, Inc. (UL)
TYPE: Direct Vent Gas Appliance
STANDARD: ANSI Z21.50-2003•CSA2.22-M03•UL307B
Model
U.S. (0-2000 FT) or Canada (2000-4500 FT) Input BTUH Orifice Size
(DMS)
Twilight II (NG) US 38,000 32
CAN 34,200 33
Twilight II (LP) US 37,000 50
CAN 33,300 51
WARNING
Do NOT use this appliance if any part has been under
water. Immediately call a qualified service technician to
inspect the appliance and to replace any part of the control
system and any gas control which has been under water.
ThisproductislistedtoANSIstandardsfor“VentedGasAp-
pliances” and applicable sections of “Gas Burning Heating
Appliances for Manufactured Homes and Recreational Ve-
hicles”,and “GasFiredAppliancesforUseatHighAltitudes”.
D. Air Infiltration, Water Resistance and
Structural Tests
TheHearth & HomeTechnologiesTwilight-IIIndoor/Outdoor
Applianceunit was testedto the followingASTM standards
at the StorkTwin CityTesting laboratory.
TestResults
Model Air Infiltration
(ASTM E283) Water Resistance
(ASTM E331) Structural Load
(ASTM E330)
Twilight-II
Indoor/Outdoor 0.07CFM/ft2No leakage @
8psf & 25psf No Blowout
@ 75psf
C. Thermal Performance Data
Model Sound
Transmission
Class (STC) Thermal Resistance
(R Value) Thermal Conductivity
(K Value)
Twilight-II 27 0.08hr-sq ft-OF/BTU 12.5 BTU-in/hr-sq ft-OF
Í
Í
G. Non-Combustible Materials Specification
Materialwhich will notignite and burn arethose consisting
entirely of steel, iron, brick, tile, concrete, slate, glass or
plasters,or anycombination thereof.Materials thatare re-
ported as passing ASTM E 136, Standard Test Method
for Behavior of Materials in a Vertical Tube Furnace
at 750oC, shallbe considerednon-combustible materials.
H. Combustible Materials Specification
Materials made of or surfaced with wood, compressed pa-
per, plant fibers, plastics, or other material that can ignite
andburn,whetherflameproofedornot,orwhether plastered
orunplasteredshallbe considered combustible materials.
Airinfiltration testASTM:E283-(04).The sample was test-
edat 1.57psf (equivalent to a 25-mph windload).
Water resistance test ASTM:E331-00. The test specimen
wastestedattherequestedtestpressures of 8.0 & 25.0psf.
Structural test ASTM:E330-02. The unit was tested to a
designpressure of 50-psf, a test pressure of 75-psf.