7
Amplifier for servo motors
Operating Instructions
Connecting an Inhibit cable
This product provides an interface connection for an Inhibit input. A label is provided near
the connector.
To connect an Inhibit cable:
Verify that the power switch is in the off position
Connect the interface cable to it’s connector
Tighten the cable connector screws until they are snug
Pin Signal Description
1GND Signal ground
2Inhibit 1 GND to inhibit, open to enable
3Inhibit 2 GND to inhibit, open to enable
Connecting a limit switch input cable
Notice
A risk of property damage exists if Limit Enable inputs are not properly
connected. Limit Enable inputs are available on the Axis Motor connector
and the Limit Switch connector. To avoid the hazard use only one pair of
Limit Enable inputs per axis. Never use the Limit Enable inputs from both
connectors. If both are used, limit switch function is severely impaired.
This product provides an interface connection for limit switch inputs. A label is provided
near the connector.
To connect a limit switch cable:
Verify that the power switch is in the off position
Connect the interface cable to it’s connector
Tighten the cable connector screws until they are snug
Pin Signal Description
1X axis
Limit
/Pos Enab
GND to enable output current in one polarity, open or DC 5 V
to inhibit. Typically used with grounded, normally closed limit
switches.
2X axis
Limit
/Neg Enab
GND to enable output current in opposite polarity, open or DC 5 V
to inhibit. Typically used with grounded, normally closed limit
switches.
3Y axis
Limit
/Pos Enab
GND to enable output current in one polarity, open or DC 5 V
to inhibit. Typically used with grounded, normally closed limit
switches.
4Y axis
Limit
/Neg Enab
GND to enable output current in opposite polarity, open or DC 5 V
to inhibit. Typically used with grounded, normally closed limit
switches.
5Z axis
Limit
/Pos Enab
GND to enable output current in one polarity, open or DC 5 V
to inhibit. Typically used with grounded, normally closed limit
switches.
6Z axis
Limit
/Neg Enab
GND to enable output current in opposite polarity, open or DC 5 V
to inhibit. Typically used with grounded, normally closed limit
switches.
7DC 5 V 5 Volts, direct current
8DC 5 V 5 Volts, direct current
9GND Signal ground
10 GND Signal ground
C
Inhibit connector
1 2 3
J
Limit switch input connector
12345678910