manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Hi-Link
  6. •
  7. USB Interface
  8. •
  9. Hi-Link HLK-RM04 Instructions for use

Hi-Link HLK-RM04 Instructions for use

深圳市海凌科电子有限公司 Shenzhen
Shenzhen
Shenzhen
Shenzhen Hi-Link
Hi-Link
Hi-Link
Hi-Link Electronic
Electronic
Electronic
Electronic Co.,Ltd
Co.,Ltd
Co.,Ltd
Co.,Ltd
Http : //www.hlktech.com Tel : 0755-83575155 Fax : 0755-83575189
Shenzhen
Shenzhen
Shenzhen
Shenzhen Hi-Link
Hi-Link
Hi-Link
Hi-Link Electronic
Electronic
Electronic
Electronic Co.,Ltd
Co.,Ltd
Co.,Ltd
Co.,Ltd
HLK-RM04
HLK-RM04
HLK-RM04
HLK-RM04 Application
Application
Application
Application manual
manual
manual
manual 1
1
1
1
Serial to Ehthernet
Shenzhen Hi-Link ElectronicTechnology co.,Ltd
Note:
Note:
Note:
Note:
To
To
To
To
ensure
ensure
ensure
ensure the
the
the
the normal
normal
normal
normal operation,
operation,
operation,
operation, please
please
please
please make
make
make
make sure
sure
sure
sure you
you
you
you have
have
have
have purchased
purchased
purchased
purchased the
the
the
the HLK-RM04
HLK-RM04
HLK-RM04
HLK-RM04
Development
Development
Development
Development Kit
Kit
Kit
Kit from
from
from
from us
us
us
us .
.
.
. as
as
as
as the
the
the
the following
following
following
following picture:
picture:
picture:
picture:
深圳市海凌科电子有限公司 Shenzhen
Shenzhen
Shenzhen
Shenzhen Hi-Link
Hi-Link
Hi-Link
Hi-Link Electronic
Electronic
Electronic
Electronic Co.,Ltd
Co.,Ltd
Co.,Ltd
Co.,Ltd
Http : //www.hlktech.com Tel : 0755-83575155 Fax : 0755-83575189
Shenzhen
Shenzhen
Shenzhen
Shenzhen Hi-Link
Hi-Link
Hi-Link
Hi-Link Electronic
Electronic
Electronic
Electronic Co.,Ltd
Co.,Ltd
Co.,Ltd
Co.,Ltd
HLK-RM04 module
HLK-RM04 test board
2.4G rod antenna
5V 1000mA power supply
mesh line (optional )
Please contact well as the following way in the picture:
深圳市海凌科电子有限公司 Shenzhen
Shenzhen
Shenzhen
Shenzhen Hi-Link
Hi-Link
Hi-Link
Hi-Link Electronic
Electronic
Electronic
Electronic Co.,Ltd
Co.,Ltd
Co.,Ltd
Co.,Ltd
Http : //www.hlktech.com Tel : 0755-83575155 Fax : 0755-83575189
Shenzhen
Shenzhen
Shenzhen
Shenzhen Hi-Link
Hi-Link
Hi-Link
Hi-Link Electronic
Electronic
Electronic
Electronic Co.,Ltd
Co.,Ltd
Co.,Ltd
Co.,Ltd
Please
Please
Please
Please note
note
note
note the
the
the
the direction
direction
direction
direction that
that
that
that HLK-RM04
HLK-RM04
HLK-RM04
HLK-RM04 plugged
plugged
plugged
plugged into
into
into
into the
the
the
the backplane!
backplane!
backplane!
backplane!
1 Brief Introduction
HLK-RM04 is a new low-cost embedded UART-ETH-WIFI module (serial port - Ethernet -
Wireless network) developed by Shenzhen Hi-Link ElectronicTechnology co., Ltd
This product is an embedded module based on the universal serial interface network standard,
built-in TCP / IP protocol stack, enabling the user serial port, Ethernet, wireless network (wifi)
interface between the conversions.
Through the HLK-RM04 module, the traditional serial devices do not need to change any
configuration; data can be transmitted through the Internet network. Provide a quick solution for
the user
’
s serial devices to transfer data via Ethernet.
深圳市海凌科电子有限公司 Shenzhen
Shenzhen
Shenzhen
Shenzhen Hi-Link
Hi-Link
Hi-Link
Hi-Link Electronic
Electronic
Electronic
Electronic Co.,Ltd
Co.,Ltd
Co.,Ltd
Co.,Ltd
Http : //www.hlktech.com Tel : 0755-83575155 Fax : 0755-83575189
Shenzhen
Shenzhen
Shenzhen
Shenzhen Hi-Link
Hi-Link
Hi-Link
Hi-Link Electronic
Electronic
Electronic
Electronic Co.,Ltd
Co.,Ltd
Co.,Ltd
Co.,Ltd
Ethernet
Ethernet
Ethernet
EthernetWIFI
WIFI
WIFI
WIFI
(
Client/AP
Client/AP
Client/AP
Client/AP
)
C hart 1. F-structure
Every part
’
s function of Test board:
2.
2.
2.
2. Serial
Serial
Serial
Serial to
to
to
to Ethernet
Ethernet
Ethernet
Ethernet configuration
configuration
configuration
configuration method
method
method
method :
Serial to Ethernet model
:
S erial Com
深圳市海凌科电子有限公司 Shenzhen
Shenzhen
Shenzhen
Shenzhen Hi-Link
Hi-Link
Hi-Link
Hi-Link Electronic
Electronic
Electronic
Electronic Co.,Ltd
Co.,Ltd
Co.,Ltd
Co.,Ltd
Http : //www.hlktech.com Tel : 0755-83575155 Fax : 0755-83575189
Shenzhen
Shenzhen
Shenzhen
Shenzhen Hi-Link
Hi-Link
Hi-Link
Hi-Link Electronic
Electronic
Electronic
Electronic Co.,Ltd
Co.,Ltd
Co.,Ltd
Co.,Ltd
Method
Method
Method
Method one
one
one
one :Configuration
Configuration
Configuration
Configuration through
through
through
through Serial
Serial
Serial
Serial port
port
port
port
1. First
ly,
please ensure that the module is in default mode . The method of r estor ing the factory
settings : power-on the module, wait 35 seconds. Then press one of the buttons on the test
board and hold on more than 6 seconds.
2. Power-on the module again , wait 35 second s until the light on the module blinking, and then
connect the DB9 serial port with the computer's serial port in a straight line. Or connect t he test
board directly with a USB to serial cable as the following picture:
3. Press the "Exit transparent transmission / Preset" button, open the configuration software,
select the serial number, click on the search button , If there appears message >: at (: Found
Device at COM8 (115200)! I n the respose area, it means the module is found.
深圳市海凌科电子有限公司 Shenzhen
Shenzhen
Shenzhen
Shenzhen Hi-Link
Hi-Link
Hi-Link
Hi-Link Electronic
Electronic
Electronic
Electronic Co.,Ltd
Co.,Ltd
Co.,Ltd
Co.,Ltd
Http : //www.hlktech.com Tel : 0755-83575155 Fax : 0755-83575189
Shenzhen
Shenzhen
Shenzhen
Shenzhen Hi-Link
Hi-Link
Hi-Link
Hi-Link Electronic
Electronic
Electronic
Electronic Co.,Ltd
Co.,Ltd
Co.,Ltd
Co.,Ltd
4
4
4
4Parameter configuration
Operating
Operating
Operating
Operating mode
mode
mode
mode : Ser2 Eth(serial to Ethernet)
Network
Network
Network
Network Protocol
Protocol
Protocol
Protocol : TCP server
Remote
Remote
Remote
Remote IP
IP
IP
IP : Remote IP is not working as a sever
Port
Port
Port
Port : The monitoring port of the starting TCP server
Serial
Serial
Serial
Serial Parameter
Parameter
Parameter
Parameter : Change the parameters according to your requirement .
Attention
Attention
Attention
Attention please
please
please
please
深圳市海凌科电子有限公司 Shenzhen
Shenzhen
Shenzhen
Shenzhen Hi-Link
Hi-Link
Hi-Link
Hi-Link Electronic
Electronic
Electronic
Electronic Co.,Ltd
Co.,Ltd
Co.,Ltd
Co.,Ltd
Http : //www.hlktech.com Tel : 0755-83575155 Fax : 0755-83575189
Shenzhen
Shenzhen
Shenzhen
Shenzhen Hi-Link
Hi-Link
Hi-Link
Hi-Link Electronic
Electronic
Electronic
Electronic Co.,Ltd
Co.,Ltd
Co.,Ltd
Co.,Ltd
DHCP:
DHCP:
DHCP:
DHCP: when the DHCP started, Modules need to obtain an IP from the router , so you should
log on the roter and find the IP of the module first in order to communicate. At this time, Cable
and PC Direct Connect is no way to communicate.
If
If
If
If you
you
you
you do
do
do
do not
not
not
not start
start
start
start DHCP,
DHCP,
DHCP,
DHCP, you
you
you
you need
need
need
need to
to
to
to know
know
know
know the
the
the
the IP
IP
IP
IP address
address
address
address specification
specification
specification
specification of
of
of
of your
your
your
your router
router
router
router
and
and
and
and fill
fill
fill
fill in
in
in
in IP
IP
IP
IP address
address
address
address youeself.
youeself.
youeself.
youeself.
For example: Our IP specification is 192.168.11.xxx.
;
255.255.255.0
;
192.168.11.1
Please set the IP parameters according to your own router. This time,t he module can connect to
the router through the network cable, can also connected with the computer ,If it directly
connected with the computer, the computer's IP should manually configured to 192.168.11.xxx;
255.255.255.0
Paremrter can cofigurate as the following picture:
深圳市海凌科电子有限公司 Shenzhen
Shenzhen
Shenzhen
Shenzhen Hi-Link
Hi-Link
Hi-Link
Hi-Link Electronic
Electronic
Electronic
Electronic Co.,Ltd
Co.,Ltd
Co.,Ltd
Co.,Ltd
Http : //www.hlktech.com Tel : 0755-83575155 Fax : 0755-83575189
Shenzhen
Shenzhen
Shenzhen
Shenzhen Hi-Link
Hi-Link
Hi-Link
Hi-Link Electronic
Electronic
Electronic
Electronic Co.,Ltd
Co.,Ltd
Co.,Ltd
Co.,Ltd
We
demonstrated here is not enabled DHCP, static IP configured.
After committing the configuration, the WIFI of the module will turn off and the LAN port will
be shut down
5
5
5
5 TCP
TCP
TCP
TCP to
to
to
to serial
serial
serial
serial data
data
data
data transfer
transfer
transfer
transfer
Submit your parameters, the module will restart, you can also re-power to the module, when
the module starts , connect the computer network port and the network port 1 of HLK-RM04
with the network cable. Please close other network card. C onfigurate Fixed IP to the computer
that connect to the the HLK-RM04 module as shown in the following picture:
Check if the ping 192.168.11.254 is ok: start ----run----cmd
深圳市海凌科电子有限公司 Shenzhen
Shenzhen
Shenzhen
Shenzhen Hi-Link
Hi-Link
Hi-Link
Hi-Link Electronic
Electronic
Electronic
Electronic Co.,Ltd
Co.,Ltd
Co.,Ltd
Co.,Ltd
Http : //www.hlktech.com Tel : 0755-83575155 Fax : 0755-83575189
Shenzhen
Shenzhen
Shenzhen
Shenzhen Hi-Link
Hi-Link
Hi-Link
Hi-Link Electronic
Electronic
Electronic
Electronic Co.,Ltd
Co.,Ltd
Co.,Ltd
Co.,Ltd
Open the serial debugging tools and network debugging tools, do send data test:
T he serial and Ethernet can send data to each other now .
深圳市海凌科电子有限公司 Shenzhen
Shenzhen
Shenzhen
Shenzhen Hi-Link
Hi-Link
Hi-Link
Hi-Link Electronic
Electronic
Electronic
Electronic Co.,Ltd
Co.,Ltd
Co.,Ltd
Co.,Ltd
Http : //www.hlktech.com Tel : 0755-83575155 Fax : 0755-83575189
Shenzhen
Shenzhen
Shenzhen
Shenzhen Hi-Link
Hi-Link
Hi-Link
Hi-Link Electronic
Electronic
Electronic
Electronic Co.,Ltd
Co.,Ltd
Co.,Ltd
Co.,Ltd
Method
Method
Method
Method two:
two:
two:
two: configuration
configuration
configuration
configuration through
through
through
through network
network
network
network port
port
port
port
1.
1.
1.
1. First restore the factory setting . Then start the module, connect the network port 2 of
HLK-RM04 test board and the computer's Network port with network cable . And then set
the computer
’
s IPas follows:
Check if ping 192.168.16.254 is all right: start----run----cmd
Note:
Note:
Note:
Note: not
not
not
not 192.168.11.254
192.168.11.254
192.168.11.254
192.168.11.254
深圳市海凌科电子有限公司 Shenzhen
Shenzhen
Shenzhen
Shenzhen Hi-Link
Hi-Link
Hi-Link
Hi-Link Electronic
Electronic
Electronic
Electronic Co.,Ltd
Co.,Ltd
Co.,Ltd
Co.,Ltd
Http : //www.hlktech.com Tel : 0755-83575155 Fax : 0755-83575189
Shenzhen
Shenzhen
Shenzhen
Shenzhen Hi-Link
Hi-Link
Hi-Link
Hi-Link Electronic
Electronic
Electronic
Electronic Co.,Ltd
Co.,Ltd
Co.,Ltd
Co.,Ltd
2.
2.
2.
2. Input 192.168.16.254/ser2net.asp in the browser, it will pop-up a dialog box, enter the user
name and password. Both of t he username and password are admin.
深圳市海凌科电子有限公司 Shenzhen
Shenzhen
Shenzhen
Shenzhen Hi-Link
Hi-Link
Hi-Link
Hi-Link Electronic
Electronic
Electronic
Electronic Co.,Ltd
Co.,Ltd
Co.,Ltd
Co.,Ltd
Http : //www.hlktech.com Tel : 0755-83575155 Fax : 0755-83575189
Shenzhen
Shenzhen
Shenzhen
Shenzhen Hi-Link
Hi-Link
Hi-Link
Hi-Link Electronic
Electronic
Electronic
Electronic Co.,Ltd
Co.,Ltd
Co.,Ltd
Co.,Ltd
As Static IP and DHCP , please reference to the method 1 . After configuration , click on the
button ‘ Apply
’
to wait for the module restart ing.
3.
3.
3.
3. Waiting for the module to restart, unplug the network cable of the HLK-RM04 network port
2 and plugged it into the Ethernet port 1. Next Steps please reference to fifth step in the
method one .

Other manuals for HLK-RM04

3

Popular USB Interface manuals by other brands

microHAM CW KEYER manual

microHAM

microHAM CW KEYER manual

Microflex MicroLink 101-0032 Installation Operation & Specifications Manual

Microflex

Microflex MicroLink 101-0032 Installation Operation & Specifications Manual

OHAUS Ranger 3000 Series instruction manual

OHAUS

OHAUS Ranger 3000 Series instruction manual

8 devices Korlan USB2CAN user guide

8 devices

8 devices Korlan USB2CAN user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.