Hiland SL20 Series User manual

electric lock
Old one New one
SLIDING GATE OPENER CONTROL BOARD SL20XX A5
4.1 Learning and erasing transmitters: Press the learning button S3 in the board, LED DL2 is on, enters into the learning process; Press the
same button twice, LED blinks for several times, then off. The learning process is successful. Press the learning button, continue pressing for
8s until LED turns off; Release learning button, LED will be on (about 1s) and then off; the erasing process is successful. (Ignore this step
if transmitter already matches the opener before delivery)
4.3 Opening/closing limit adjustment: Remote control the door ( or move the door manually ) , adjust the position of limit device to make sure
the door would touch the limit switch when open or close the door .LED LD6/DL5 in the controller will be off when limit device touches limit
switch(Limit switch is NC).
4.4 External infrared switch:Photocell connector connects the NC contact of photocell switch , DL4 LED turn on after the connection, And DL4
LED turn off when blocking out the transmit or receive signal of photocell artificially. Infrared sensor doesn't react when door openning and
the door will reverse to limit point if photocell signal disconnect when door closing. If no need of using photocell protection, make the
connector of photocell short circuit with terminated line(the connector is short circuit when leave factory).
I Safety Instruction
1.2 Please clear the memory before initial operation. (Ref.: Erasing ALL learned/memorized Transmitters)
1.3 Do not learn the remote control when motor is operating in order to avoid mis-operation.
1.1 For security, please read instructions carefully before initial operation; making sure that the power is off before connection.
1.3 The received signal may be interfered by other communication devices. (e.g. the wireless control system with the same frequency range)
1.4 It is used only for the manual remote control and wireless control equipment / system which must not endanger life or property during
running failure, or its security risks have been eliminated.
III Wire connection
IV Set up
·Tip of Remote control self-learning function: Use the transmitter that already has been
learned as old transmitter, press button 1 and button 2 at the same time and then press button 2
to let it enters into the learning process .In this way , new transmitter can be learned without
press the learning button on the control board. (SL2000 and SL2020 can learn 30pcs max,SL2003
and SL2023 can learn 300pcs max)
4.2 self-learning function: Learning new remotes by old remotes
Old one
1.5 It should be applied in dry indoor place or in the electric appliance place.
II Technical Index
2.1 Working voltage: 220VAC/110VAC,50Hz/60Hz
2.2 Temperature range: -20℃to 60℃
2.3 Loading capacity : 2HP 220VAC/1HP 110VAC
2.4 Built-in fuse: electric circuit(0.5A); Motor(10A),Please
exchange appropriate fuse accoding to loading capacity
2.5 Time of soft-start : 1S ; soft-stop: 3S/5S/7S are optional
2.6 Running time: Adjustable from 5s to 150s ----S4 is to set up
2.7 Frequency: 433.92MHz
2.8 Transmitter stored: 30PCS/200/300PCS
2.9 Output voltage: AC24V
2.10 Output with electric lock: AC220V/AC110V
2.11 Output with flash lamp: AC220V/AC110V
2.12 External switch (open,stop,close in a loop)
2.13 External limit ( DIP8 to select NO and NC)
2.14 External infrared (NC contact)
2.15 Resistance of opening and closing door is adjustable
2.16 Auto close time is adjustable: (5S,10S,30S are optional by using
DIP1,DIP2)
2.17 Deadman and Impulse remote system are optional by DIP5
2.18 Installation at left or right side is optional by DIP6.
2.29 Single / three button control is optional by DIP7
2.20 Size: 165*92*38
2.21 Weight: 453g

DIP1 DIP2
Auto close time DIP3 DIP4 Soft stop time DIP5 Latch and non-latch for remote control
OFF OFF No auto close OFF OFF
No soft stop
ON Deadman,Latch
OFF ON 5S OFF ON 3S OFF Non-latch
ON OFF 10S ON OFF 5S
ON ON 30S ON ON 7S
DIP6 DIP7 DIP8
ON ON ON External limit NC switch
OFF OFF OFF External limit NO switch
Model Frequency Code
SL2000 433.92Mhz Rolling
SL2003 433.92Mhz Rolling
SL2001 433.92Mhz Rolling
SL2020 433.92Mhz Rolling
SL2023 433.92Mhz Rolling
SL2021 433.92Mhz Rolling
The interpretation and ownership of this manual belong to Hiland company. Any change of the product can be without prior notice.
110VAC
300
Description:
Single button control , press-open-press-stop-
press-stop; Only the learned button is effective
in the transmitter, original button is not
effective any more when a new button has been
learned in the same transmitter (For example,
button 1 was learned firstly, button 2 or 3 has
been learned of the same transmitter afterwards
, then button 1 was not effective any more)
4.5 Motor running time adjustment: Motor running time is adjustable from 5s to 150s. Press S4 button to close the door when the door opens at
the openning limit position and the door stops when meets closing limit .It is the closing running time of motor. Press S4 button to open the
door when the door is closed at the closing limit position and the door stops when meets openning limit .It is the openning running time of
motor .(It is only needed to select one process between these two. DL3 keeps blinking during the process and will be off after motor stops at
the limit position. Running time adjustment is finished).
4.6 Resistance adjustment: Adjust potentiometer P.Open/P.Close to change the opening/closing resistance. Resistance increases when adjust it
C.W .Make a resistance to door after the adjustment in order to check if it is appropriate .
4.7 Soft stop speed adjustment: Adjust potentiometer PT3(SoftSpeed) to adjust the speed of soft stop. Speed goes down when adjust it CCW ( Soft
stop speed adjustment only work when time of soft stop is effective )
VI Notes
6.2. Open and stop resistance shall be examined regularly.
VII Model difference
6.1. Man-made resistance is needed after adjusting resistance,in order to make sure the resistance is appropriate or not.
200
Working voltage
220VAC
220VAC
110VAC
110VAC
Transmitter stored (pcs)
30
200
30
220VAC
300
5.2 Single button control process (DIP 7 at ON position)
4.8 DIP switch S5 logic function:
Right/left side installation
ON or OFF can change
the current operating
direction of motor
Single button control
Three button control
V Operation Instruction
5.1 Three button control process (DIP 7 at OFF position)
STOP
Press transmitter button 1
Press transmitter button 3
Open
limit
point
Press
transmitter
button 2
Close
limit
point
Close
resistance
Photocell
protection
Press
transmitter
button 2
Open
resistance
Max
running
time
Max
running
time
OPEN CLOSE
Close
limit
point
Close
resistance
Photocell
protection
Press
transmitter
button 1
Max
running
time
Press transmitter button 1
Open
limit
point
Press
transmitte
r button 1
Open
resistance
Max
running
time
OPEN
STOP
STOP
Press transmitter button 1
CLOSE
This manual suits for next models
6
Other Hiland Garage Door Opener manuals
Popular Garage Door Opener manuals by other brands

Linear
Linear LDCO 841 Homeowner's manual

Henderson
Henderson Magic 600 operating manual

V2
V2 Gold Series manual

Somati system
Somati system OGS User & installation manual

Chamberlain
Chamberlain FS2 Security+ owner's manual

Roger Technology
Roger Technology BM30/403 INSTRUCTIONS AND RECOMMENDATIONS FOR THE INSTALLER

Chamberlain
Chamberlain APT owner's manual

BFT
BFT Botticelli VENERE D Installation and user manual

Wisniowski
Wisniowski UNITHERM SSp Assembly and operating instructions

Chamberlain
Chamberlain LiftMaster 50-WSE-14 manual

DoorHan
DoorHan SLIDING-1300 Installation and operation manual

Craftsman
Craftsman 139.53985DM owner's manual