g
g
g
g
g
g
g
g
g
ha ~ma BñVo_mb Ho$ ~mX J¡g dmëd
H$mo "Am°\$' H$a Xo. (aoIm{MÌ 11).
3. ~Z©a M`Z ~m°Z
_m¡g_/nmZr Ho$ ~hmd H$s pñW{V`m|
Ho$ AZwgma 1,2 `m 3 ~Z©am| Ho$ BñVo_mb,
H$aZo Ho$ {bE ~Z©a M`Z Zm°~ H$mo Bg pñW{V
_| Kw_mE§. Vm{H$ g~go Cn`wº$ Vmn_mZ H$m
nmZr {_b gHo$ Am¡a COm© Ho$ bmJV IM© _| ^r
~MV hmo gHo$.
gwajm hoVw gmdYm{Z`m§
J¡g [agmd go ~Mmd
h_oem gm~wZ nmZr go g_ñV J¡g nmBn H$ZoŠeÝg H$s Om§M
H$a b| {H$ H$ht go J¡g H$m [agmd Vmo Zht hmo ahm h¡. AJa
H$ht go J¡g [ag ahr hmo Vmo VwaÝV J¡g H$s gßbmB© ~§X H$a X|
VWm {I‹S>{H$`m| H$mo Imob X|. E¡gr pñW{V _| Bp½ZeZ,
{~OZr Ho$ pñdM H$mo Am°Z/Am°\$ {~ëHw$b Z H$a|, Š`m|{H$
Bggo {dñ\$moQ> hmoZo `m AmJ bJZo H$m IVam n¡Xm hmo gH$Vm
h¡. (aoIm {MÌ 12)
àË`oH$ ~ma BñVo_mb H$aZo Ho$ ~mX âbo_ H$mo ~wP OmZo H$s
Om§M H$aZm `mX aI|. O~ dm°Q> hrQ>a H$m BñVo_mb Z H$a aho
hm|, J¡g dmëd H$mo ~§X H$a X|.
(aoIm {MÌ 11)
J¡g Q>çy~ H$s {Z`{_V ê$n go Om§M
H$aVo ah|, Š`m|{H$ bå~o g _ `
VH$ BñVo_mb Ho$ ~mX `h nwamZr n‹S> gH$Vr
h¡ VWm Bg_| Xama| n¡Xm hmo gH$Vr h¢. AJa
Xama| n¡Xm hmo J`r hm| Vmo Bgo ~Xb X|.
gm_mÝ` àMmbZ pñW{V`m| _| EH$ gmb Ho$ ~mX Q>çy~ H$mo ~Xb
XoZm Mm{hE.
EbnrOr BñVo_mbH$Vm©Amo Ho$ {bE. AJa hrQ>a H$s âbo_ _|
ñWm{`Ëd Zht h¡ Vmo BgH$m H$aU J¡g Ho$ {gqbS>a Ho$
AmBQ>boQ> go Ow‹S>o àoea ao½`wboQ>a H$m Xmof`wº$ hmoZm hmo
gH$Vm h¡. Eogr Xem _|, hrQ>a H$m BñVo_mb VwaÝV ~§X H$a X|
VWm A{YH¥$V J¡g g{d©g Q>opŠZ{e`Z go gånH©$ H$a|.
nrEZOr BñVo_mbH$Vm©Am| Ho$ {bE. AJa hrQ>a H$s âbo_ _|
ñWm{`Ëd Zht h¡ Vmo BgH$m H$maU J¡g X~md _| AñWm{`Ëd
H$m hmoZm hmo gH$Vm h¡. Eogr Xem _|, hrQ>a H$m BñVo_mb
VwaÝV ~§X H$a X| VWm J¡g gßbmB© EOoÝgr go gånH©$ H$ao.
Ap½Z XwK©Q>Zm go ~Mmd
gmoZo go nhbo h_oem _oZ J¡g gßbmB© H$mo ~§X H$a Xo.
âby {ZH$bZo `m hdm àdoe H$aZo Ho$ _mJ© Ho$
Amg nmg ÁdbZerb MrO| O¡go {H$ Vm¡{b`m
H$n‹S>o Am{X Z aI|. (aoIm{MÌ 13)
g
g
g
g
g
g
g
g
Turn off the gas valve after each
use. (FIG.11)
3. Burner selector knob
Depending on seasons / water
flow conditions, turn the bu rner
selector knob to position 1 or 2 or
both burners to be used, so
as to get the most comfortable
water temperature and also save
energy cost.
Cautions for safety
Gas leak prevention
Always check all the gas pipe connections, with soap
solutions to check whether it has gas leak. In case of
gas leak, shut off the gas supply and open the
windows immediately. Under such condition, ignition,
switching on/off the electric power supply are strictly
prohibited to avoid explosion and fire (FIG.12)
Check whether the flame is extinguished after each
use. Always turn off the gas valve when not in use
(FIG.11)
Check the gas tube regularly, as it
may age and crack after long
period of use. Replace it if
cracked. Under normal operations,
the gas tube should be replaced
yearly.
For LPG users, if the flame of the
heater is not stable, it may be caused by a defective
pressure regulator connected to the outlet of the
gas cylinder. In that case, stop using the heater
immediately and contact authorized gas service
technician.
For PNG users, if the flame of the heater is not stable,
it may be caused by the instability of the gas
pressure. Stop using the heater immediately and
contact the gas supply agency.
Fire accident prevention
Always shut off the main gas supply
valve before retiring to bed.
g
g
g
g
g
g
g
Do not place inflammables like towel
or cloth near the flue outlet or the air
inlet. (FIG.13)
Do not pile inflammables, explosives
or volatile materials near the heater.
(FIG.14)
For LPG users, do not place the
cylinder tilted or inverted or on its side.
Prevention of excessive Carbon
Monoxide concentration
As in all gas appliances like your cooking stove, the
burning of gas consumes large amount of air and
produces some amount of poisonous carbon
monoxide. Carbon Monoxide concentrations above
a certain level is injurious to life, therefore, the heater
must be fixed in a ventilated location. Keep exhaust
fans running, if provided or else, windows and. the
ventilation ducts always open. .
PNG users. When the gas pressure is insufficient,
the carbon deposit in the burner may increase and
affect the efficient use of the heater. In such case,
flame would turn from blue to yellow, Stop using the
heater and contact the gas agency or the service
center.The heater must be installed vertically.
Prevent injuries to the Eyes
Keep eyes away from the flame indicator window at
a minimum safety distance of 300 mm during
ignition. If the first attempt of ignition fails, wait 10-
20 seconds before the next attempt.
Prevent "no-water" Burning in the Heater
After each use, make sure that the flame is
extinguished when there is no water flow,. If the flame
still exists, switch off the gas valve immediately and
contact the service center, otherwise the heat
exchanger may be damaged due overheating.
Freezing Prevention
When temperatures are near 0° C, it is
recommended that all residual water, in the water
heater is drained out after use, by removing the drain
valve and allowing the water to flow out. Re-Install
the drain valve before using the water heater again.
Freezing of water inside, will permanently damage
the heat exchanger.
Reduce scaling
g
g
g
g
g
g
g
g
g
g
hrQ>a Ho$ ZOXrH$ ÁdbZerb, {dñ\$moQ>H$
`m AmJ nH$‹S>Zodmbr MrO| O_m Z H$ao.
(aoIm{MÌ 14)
EbnrOr BñVo_mbH$Vm©Am| Ho$ {bE,
{gqbS>a H$mo Q>o‹T>m, CëQ>m `m {bQ>mH$a Z aI|.
AË`{YH$ H$m~©Z _moZmo Am°ŠgmBS> O_m hmoZo
go ~Mmd
g_ñV J¡g CnH$aUm|, O¡go {H$ ImZm
nH$mZo H$m ñQ>mod, _| J¡g Ho$ ObZo Ho$ {bE H$m\$s
hdm H$s Amdí`H$Vm hmoVr h¡ Am¡a BgHo$
\$bñdê$n H$m~©Z _moZmoAm°ŠgmBS> Zm_H$ Oharbr J¡g
Hw$N> _mÌm _| n¡Xm hmoVr h¡. H$m~©Z _moZmoAm°ŠgmBS> H$s EH$
A§e go A{YH$ gKZVm OrdZ Ho$ {bE IVaZmH$ h¡ Bg{bE
hrQ>a H$mo Eogr OJh na {~R>mZm Mm{hE, Ohm§ hdm H$s
AmdmOmhr hmo. AJa E½Om°ñQ> n§I| hmo Vmo BZH$mo Mmby
aI|. AÝ`Wm {I‹S>{H$`m| VWm dopÝQ>boeZ S>ŠQ²>g H$mo
h_oem Iwbm aI|.
nrEZOr BñVo_mbH$Vm©Am| Ho$ {bE. J¡g H$m X~md n`m©ßV
Z hmoZo na ~Z©a na O_m hmoZo dmbo H$m~©Z Ho$ H$Mao H$s _mÌ
~‹T> gH$Vr h¡ {Oggo hrQ>a H$s H$m`©j_Vm à^m{dV hmoVr h¡,
Eogr pñW{V _| Ádmbm H$m a§J Zrbo go nrbm hmo OmEJm. Eogm
hmoZo na hrQ>a H$m BñVo_mb ~§X H$a X| VWm J¡g H§$nZr H$m
g{d©g goÝQ>a go gånH©$ H$a|.
hrQ>a H$mo I‹S>r pñW{V (Bîdm©Ya) _| {~R>m`m OmZm Mm{hE.
Am§Im| H$mo OI_r hmoZo go ~MmZm
Bp½ZeZ Ho$ Xm¡amZ AnZr Am§Imo H$mo h§_oem Ádmbm g§Ho$VH$
{I‹S>H$s go H$_ go H$_ 300 {__r H$s gwa{jV Xyar na aI|.
AJa nhbr H$mo{ee _| Bp½ZeZ Zht hmoVm h¡ Vmo 10-20
goHo$ÊS> ê$H$ H$a Xmo~mam H$mo{ee H$ao.
hrQ>a H$mo "{~Zm-nmZr' ObZo go ~MmZm
gw{ZpíMV H$a| {H$ àË`oH$ ~ma BñVo_mb Ho$ ~mX O~ nmZr
H$m ~hmd Z hmo, âbo_ H$mo ~wPm {X`m OmVm h¡. AJa Ádmbm
A^r ^r _m¡OyX hmo Vmo J¡g dmëd H$mo VwaÝV ~§X H$a| VWm
g{d©g goÝQ>a go gånH©$ H$a|. AÝ`Wm Á`mXm J_© hmo OmZo go
hrQ> EŠgM|Oa j{VJ«ñV hmo gH$Vm h¡.
\«$sqOJ go ~Mmd
O~ Vmn_mZ 0 {S>J«r Ho$ H$ar~ hmo, Vmo gwPmd {X`m OmVm h¡
{H$ dm°Q>a hrQ>a Ho$ BñVo_mb Ho$ ~mX S´>oZ dm°ëd H$mo hQ>m H$a
~Mm hþAm, nyam nmZr {ZH$mb X|. dm°Q>a hQ>a H$mo Xmo~mam
BñVo_mb H$aZo go nhobo {\$a go S´>oZ dm°ëd H$mo bJm Xo.
AÝXa nmZr O_Zo na hrQ>a EŠgM|Oa h_oem Ho$ {bE
j{VJ«ñV hmo OmEJm.
nn‹S>r n‹S>Zm H$_ H$aZm
BñVo_mb H$aZo VWm J¡g ñQ>mod H$mo Am°\$ H$aZo Ho$ ~mX J¡g
dm°Q>a hrQ>a go J_© nmZr V~ ~mha {ZH$mbVo ah| O~ VH$
{H$ R>§S>m nmZr Z AmZo bJo. BgHo$ ~mX nmZr Ho$ dmëd H$mo ~§X
H$a X|.
12 13
Fig.11(aoIm{MÌ 11)
TURN OFF THE GAS VALVE AFTER USE
Fig.12(aoIm{MÌ 12)
POWER SWITCH
DON’T TOUCH
OPEN THE WINDOW WHEN YOU SMELL GAS
DO NOT HANG
THINGS
OVERHEAD
Fig.13(aoIm{MÌ 13)
Fig.14(aoIm{MÌ 14)
ACID ALKALI
FLAMMABLE
LIQUID