Homech HM-AH001 User manual

MODEL: HM-AH001
ULTRASONIC COOL MIST HUMIDIFIER
User Manual
HM-AH001
NORTH AMERICA
Email:
suppor[email protected](US)
suppor[email protected](CA)
US Distributor: SUNVALLEYTEK INTERNATIONAL INC.
Address: 46724 Lakeview Blvd, Fremont, CA 94538
EUROPE
E-mail:
suppor[email protected](UK)
suppor[email protected](DE)
suppor[email protected](FR)
suppor[email protected](ES)
suppor[email protected](IT)
EU Importer: ZBT International Trading GmbH, Halstenbeker
Weg 98C, 25462 Rellingen, Deutschland
Shenzhen NearbyExpress Technology Development Co.,Ltd.
Address: 333 Bulong Road, Shenzhen, China, 518129
MANUFACTURER
www.homech.net
Extend your warranty to 18 months by registering
your prodcut on our website:www.homech.net/warranty

STATEMENT
SAFETY INSTRUCTIONS
BEFORE USING THE HUMIDIFIER
WHEN USING THE HUMIDIFIER
AFTER USING THE HUMIDIFIER
PACKAGE CONTENTS
SPECIFICATIONS
PRODUCT DIAGRAM
OPERATIONS AND FUNCTIONS
Add water
Power On / Off and Mist Adjustment
Low Water Protection: Auto Shut-off the Humidier
CLEANING AND MAINTENANCE
Caution
Daily Maintenance
Weekly Maintenance
Scale Removal Instructions
Disinfecting Instructions
Clean the Dustproof Sponge
End-Of-Season Care and Storage
TROUBLESHOOTING GUIDE
WARRANTY
HOMECH CUSTOMER CARE
CONTENTS
01
01
06
08
10
13/15
07
16
16
06
02/03
04
05
08
09
09
10
10
10
10/11
12
12
12

STATEMENT
Thank you for purchasing a Homech product that has been tested to meet our stringent
quality standards. This product is covered with Homech product and labor warranty for 12
months from the date of its original purchase.
Please email us with your order ID and problem or issue, we will respond within 24 hours.
Please read the User Manual thoroughly. Clean and maintain the product as instructed. If any
abnormalities occur, please refer to the Troubleshooting Guide rst.
This warranty is void if the defect is caused by accidental damage, misuse, abuse, neglect,
improper repair or alteration by unauthorized persons, or a failure to follow operating instruc-
tions provided with the product including adding essential oils directly into the tank and base.
This warranty does not apply to normal wear and tear or commercial use.
In no event shall liability exceed the purchase price paid by the purchaser of the product.
Under no circumstances shall there be liability for any loss – direct, indirect or incidental – or
consequential damage arising out of, or in connection with the use of the product.
SAFETY INSTRUCTIONS
The humidier was made with safe and environmental protection materials, it has been
certied and complied with the requirement of sale regions’ related regulations or laws.
IMPORTANT: Please read and save this SAFETY INSTRUCTIONS before using the device.
Basic precautions should always be followed to reduce the risk of re, electrical shock, and
injury to persons or damage to the product.
BEFORE USING THE HUMIDIFIER
1. Please extend the cord and check any signs of damage. Do not use the humidier if the cord
has been damaged.
2. DO NOT place this humidier in wet environments.
Please always keep the humidier out of reach of patients & children & pet.
1. Please always place the unit on a smooth, at, lint-free, non-metallic, waterproof and level
surface and keep it away from direct sunlight.
2. Always place the unit 2 feet (60 cm) above the oor, 12 inches (30 cm) away from the wall,
other appliances or wooden furniture.
02
1
30 CM
60 CM
2
30 CM
1
01
2

1. DO NOT place the unit on carpet, towel or wood surface, which will block the vent and may
damage the unit.
2. DO NOT place the humidier near naked ames and heat sources, such as stove tops,
ovens, radiators or computers.
WHEN USING THE HUMIDIFIER
1. DO NOT plug the unit with wet hands.
2. DO NOT direct the mist nozzle against the wall.
1. DO NOT use your hand or any other object to cover the nozzle while the unit is on to avoid
damaging the product or causing injury.
2. DO NOT clean the unit while it is connected to a power source or while it is on.
1. DO NOT move or tilt the humidier while it is in operation.
2. The most comfortable environmental humidity is between 40%-60%. Please adjust the mist as
needed.
Humidity
40% 60%
12
12
12
12
04
03

AFTER USING THE HUMIDIFIER
1. Always disconnect from a power source by pulling the plug when not in use.
2. Humidier requires regular cleaning. Please refer to, and follow the Cleaning and
Maintenance instructions.
1. DO NOT clean the humidier right after turning it off if the humidier has been diffusing warm
mist. Allow the humidier to completely cool down before cleaning.
2. DO NOT attempt to repair or adjust any electrical or mechanical functions on this humidier.
Doing so will void your warranty.
· 1 x Homech Humidier (Model: HM-AH001)
· 1 x Cleaning Brush
· 1 x Dustproof Sponge
· 1 x Thank You Card
· 1 x User Manual
HM-AH001
AC100-120V 50 / 60Hz
Min: 15W
Max: 25W
4.0L / 1.06Gal
Min: 60ml/h
Max: 300ml/h
12-50h
20-40m² / 215-430ft²
<27dB
258 x 164 x 338mm / 10.2 x 6.5 x 13.3in
1350g / 47.6oz
Model
Operating Voltage
Rated Power
Water Tank Capacity
Mist Output
Working Time on a Full Tank
Recommended Room Size
Noise
Dimensions
Net Weight
PACKAGE CONTENTS
SPECIFICATIONS
12
12
06
05

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
1. Nozzle
2. Handle
3. Water Tank
4. Water Level Window
5. Base
6. Power Cord
7. Control Knob
8. LED Indicator
9. Mufer
10. Tank Cap
11. Water Inlet
12. Air Outlet
13. Water Reservoir
14. Atomizer
15. Water Floater
16. Dustproof Sponge
17. Air Inlet
OPERATIONS AND FUNCTIONS
1
Add water
1. Turn the water tank upside down. Remove the tank cap and ll the tank with clean and
cool water only.
2. Attach the tank cap and place the tank back onto the base. Please make sure it ts
together securely so that water can go from the tank to the reservoir.
5
1 2 3 4
1. If tap water is too hard, it is recommended to use ltered or distilled water to avoid white
dust. DO NOT use hot water.
2. DO NOT add any essential oils or medicinal tablets into the water tank.
3. DO NOT add water into the base or through nozzle.
4. DO NOT move the humidier while the water tank is full of water to avoid leakage or base
overlling.
3
PRODUCT DIAGRAM
24
08
07

Power On / Off and Mist Adjustment
Plug the power cord into a wall socket. Now the humidier is ready for use.
1. Rotate the control knob clockwise to the ON position. The white LED indicator will light up
indicating the humidier has been turned on to a minimum mist level.
2. Keep rotating the control knob clockwise to increase the mist level.
3. Rotate the control knob counterclockwise to the OFF position to turn off the humidier. The
LED indicator will turn off. The fan will work for another 3 minutes to dry the mist tube.
The most comfortable environmental humidity is between 40%-60%. Please adjust the mist
as needed.
Low Water Protection: Auto Shut-off the Humidier
When there is not enough water inside the water reservoir, the humidier will stop misting and
the LED indicator will become red. It is designed for safety to prevent the humidier from
possibly overheating and damaging the atomizer.
CLEANING AND MAINTENANCE
Caution
1. DO NOT submerge the base in water.
2. Make sure water does not enter the base through the air outlet, air inlet,
or the control knob.
3. DO NOT wash any part of this humidier in dish washer which will
damage the humidier and void the warranty.
Daily Maintenance
Turn off the humidier, unplug it from the power source. Drain water from the tank, reservoir
and base.
Weekly Maintenance
1. To properly clean your humidier, we recommend you to remove scale and disinfect the
humidier separately.
2. DO NOT mix vinegar and bleach solutions together. Do not use more than 1 tsp. of
bleach per gallon of water to avoid damaging your humidier.
3. Please make sure the sealing ring on the tank cap is installed properly after cleaning to
avoid water leakage.
1 2
Scale Removal Instructions
10
09

15S
3
15-20
minutes
4
56
1. Turn off and unplug the humidier.
2. Remove the water tank from the base. Remove the tank cap. Make sure that the white
sealing ring does not come off. Drain water from the water tank and base. Remove any
accessories and set aside.
3. Fill the water tank half full. Add in 1 teaspoon of undiluted distilled white vinegar. Attach the
tank cap and shake for 15 seconds.
4. Place the tank onto the base. The vinegar solution will enter the water reservoir to loosen
mineral buildup (scale) on the atomizer, water oater and the bottom of the water tank. Set
still for 15-20 minutes.
5. Uncap the tank cap and drain the solution. Wipe the atomizer and oater with a soft cloth
to remove loosened mineral deposits.
6. Rinse both the water reservoir and water tank until the smell of vinegar (for scale removal)
or bleach solution (for disinfecting, see below) is gone.
Disinfecting Instructions
1. Follow steps 1-2 of the previous section on scale removal.
2. Fill the water tank half full. Add in ½ tsp of bleach. Place the tank cap back on. Swish the
solution around in tank. Place the tank on the base. The bleach solution will enter and
disinfect the water reservoir as well as the other components. Set still for 15-20 minutes.
3. Follow steps 4-6 of the previous section on scale removal to complete disinfecting the
humidier.
End-Of-Season Care and Storage
1. Follow the cleaning instructions when the humidier will not be used for at least one week,
or at the end of the season. Remove any accessories used with the humidier and allow the
humidier and accessories to dry completely before storing.
2. DO NOT store with water inside the base, water reservoir, or tank.
3. Pack the unit safely and store in a cool, dry location.
Clean the Dustproof Sponge
Clean the dustproof sponge (at the bottom of base) with water or detergent once a month.
Put it back in place after cleaning.
12
11

TROUBLESHOOTING GUIDE
1. If the information listed in the troubleshooting guide can’t solve your problem, please
email us for help.
2. Failure to keep this unit clean from mineral deposits may affect operation of this unit.
3. Customer failure to follow these instructions may void the warranty.
1
3
2
1. Spring
2. Sealing Ring
3. Water Floater
Problem Possible Cause Solution
Unit not plugged in
No power from power outlet
Did not turn on the unit
Ensure unit is properly
plugged in
Try another power outlet
Check the Control Knob is
turned to the ON position.
LED indicator is off
Ensure the Spring is
secured properly to the tank
bottom allowing water to pass
through to the base
1
Adjust the water oater to
a horizontal position and
make sure it can rise up with
water
3
Water oater stuck
3
No water in the water
reservoir
LED indicator stays red
Not enough water inside the
tank Rell and reinstall the water tank
The LED Indicator is white but
no mist or little mist is
produced
Mist level is set too low Adjust to maximum mist
Mineral buildup on the
atomize
Feel if any air comes out from
the nozzle. If yes, then clean
water scale on the atomizer
as instructed
The base might be overlled
Remove the tank, empty the
base and place the lled tank
on the empty base
Tank leakage
Tank may be damaged Check for possible cracks in
the tank, replace if necessary
Tank cap is not tightened
securely Tighten the tank cap
Spring stuck
Ensure the spring is
properly secured to the tank
bottom allowing water to
pass through to the base.
1
1
Sealing ring was not
installed on tank cap
Install the sealing ring on
the tank cap, please contact
us if it is missing
22
Mist level is set too high for
the room size
1. Check if the room is too
humid and adjust to lower
mist. 40%-60% works best
2. Open door and windows,
or change to a larger room
Air inlet is blocked
Humidier should be placed
on a hard at surface, 2 feet
above the oor, 12 inches
away from the wall. Point
nozzle away from wall or
window
Low indoor temperature
leads to liquefaction
Raise the room temperature
to 25°C / 77°F
Mist height is low, damping
surrounding desk or oor.
Condensation forms around
humidier or on windows
and walls
14
13

Mist level is set too low for
the room size
1. Adjust to maximum mist
2. Close door or windows to
reduce air ventilation, or
change to a smaller room
Poor humidication
Air inlet is blocked
Humidier should be placed
on a hard at surface, 2 feet
above the oor, 12 inches
away from the wall
Low indoor temperature
leads to liquefaction
Raise the room temperature
to 25°C / 77°F
Tap water may contain too
much minerals
Replace with ltered or
distilled water
White dust appears or the
black coating on the base
akes off
Clean the unit
1. Clean the humidier as
instructed
2. Leave the empty and
opened water tank in a
cool place for 12 hours
without the tank cap
attached
Strange Odor
Water is going down to the
water reservoir
This is normal while it is
working
Strange water noise
Unit works for too long
Power off and place in a
well-ventilated place for 10
minutes
Humidier is getting too hot
This product is covered with Homech product and labor warranty for 12 months from the
date of its original purchase. You will be given a warranty extension to 18 months if the
product is registered on our website (www.homech.net).
Any defective part will be, at the discretion of SUNVALLEYTEK INTERNATIONAL INC. , repaired
or replaced at no charge if the appliance has not been tampered with and has been used
according to these printed directions.
to launch a warranty claim. Specify model number and your Amazon order number. Our
Consumer Service Representative will respond within 1 business day, advise you how to
correct the problem yourself, or instruct you on how to return the defective unit back to us for
repair or replacement.
We can only provide after sales service for products that are sold by Homech or Homech
authorized retailers and distributors. If you have purchased your unit from a different place,
please contact your seller for return and warranty issues.
PLEASE CONTACT US BEFORE RETURNING THIS PRODUCT TO THE STORE.
EMAIL HOMECH CUSTOMER CARE FOR PROBLEMS AND QUESTIONS.
WE WILL RESPOND WITHIN 1 BUSINESS DAY.
WARRANTY
CONTACT / HOMECH CUSTOMER CARE
E-mail:
Website: www.homech.net 16
15

尺寸:150*200mm
装订成册
材质:封面128克铜版纸 内页80克书纸
Model:
HM-AH001
Table of contents
Other Homech Humidifier manuals