6 of 36
Service Manual UK
Indesit
Company
English
MODEL INTRODUCTION
All models are similar with regard to the furniture design, but there are variations for energy consumption
and exterior colour.
Model FF187E interior:
The interior of the fridge has glass shelves, chromed steel wine rack and two salad bins with a glass cover.
The door has a bottle shelf with retainer, dairy shelf with a lid and one commodity shelf.
The freezer section has four drawers of varying sizes, the lower two drawers have ice cube compartments
inserted in the top of the drawer fronts.
Model FF200E interior:
The interior of the fridge has glass shelves, chromed steel wine rack, fresh box (chiller compartment) and
one full width salad bin with a glass cover. The door has a deep bottle shelf with retainer, dairy shelf with a
lid and one commodity shelf. The freezer section has four drawers of varying sizes, the lower two drawers
have ice cube compartments inserted in the top of the drawer fronts.
The electronic thermostat and LED interface are all part of the power module mounted in the top facia of the
appliance; The fridge and freezer temperature settings are adjusted by operating the control knobs mounted
in the top facia. All functions are monitored and actioned by the power module mounted in the top facia of
the appliance. The fridge baffle is of a motorised type, mounted inthe multi-flow unit. The fridge temperature
is monitored by a sensor mounted in the return ducting behind the fridge multiflow unit.
The fridge and freezer temperatures are monitored by sensors located in the following locations:
1. Fridge Sensor ~ mounted in the return duct behind the fridge multiflow unit;
2. Freezer Air Sensor ~ mounted in the lower right side of the freezer cabinet liner;
3. Freezer Evaporator Sensor ~ inserted into the top right of the evaporator.
The sensors (thermistors) are not replaceable because they are for the most part foamed behind the liner
where they are not affected by moisture. The sensors are double insulated and in the unlikely event of
failure a section of the power module is programmed to respond and control the functions on a timed basis
from there on in.
The appliance is "no-frost" design (Full Frost-Free) so defrosting is automatic.
All models have rear wheels located in the compressor base plate with adjustable feet fitted at the front.
Doors are reversible, but do require a T20 Torx key to remove the plinth / kick strip.
The climate class is SN / ST signifying that it is designed to operate in ambient temperatures between
+10°C to +38°C. As with many refrigeration appliances, it is important that it is installed and operated within
the recommended ambient temperature range and that there is adequate ventilation.
ANTI-BACTERIA (Hygiene Control)
Some models have anti-bacteria protection (hygiene control) - built in protection for life of the product. Food
safety is becoming increasingly important to consumers with more and more cases of food poisoning.
The hygiene control is built into the plastic of the fridge interior during manufacture so it cannot wash or
wear out. It provides permanent protection against bacteria as it reduces on contact the spread of food
poisoning bacteria, which can cause contamination and odour.
It gives extra hygiene reassurance as it kills or inhibits the growth of any bacteria, which may come into
contact with the interior surfaces of the fridge.
The anti-bacteria protection is approved safe for use in food contact applications by the European Scientific
Committee for Food and has proven safe over many in personal care and household cleaning
products.products.